已阅读5页,还剩3页未读, 继续免费阅读
版权说明:本文档由用户提供并上传,收益归属内容提供方,若内容存在侵权,请进行举报或认领
文档简介
1附录A外文翻译原文DESIGNANDEFFICIENYASPECTSOFROTARYDRYERSbyGregPalmer,B.E.Ph.D.andTonyHowes*,B.E.Ph.D.PalmerTechnologiesPtyLtd,Brisbane,Australia*DepartmentofChemicalEngineering,UniversityofQueensland,St.Lucia4072Australia.IntroductionThedryingofproductslikesand,aggregates,fertilizersandfoodproductsisanimportantstepinindustrialprocesses.Withanincreasingfocusonreducinggreenhousegasemissionsandenergydemandthedesignofdryingunitshasbecomecritical.Inthepastrotarydryershavebeeninsomecasesthermallyveryinefficientprimarilyduetopoordesign.Fluidbeddryersontheotherhandarethermallyveryefficientduetotheintermentcontactofthegasstreamwithindividualparticlesandabetterunderstandingofthedesignprinciples.Thus,thescienceoffluidbeddryerdesignmeanstheseunitsarerelativelyeasytodesigneventhoughthermalenergydemandbetweeneachtypeofunitisapproximatelythesame.Theproblemisthatthesamelevelofengineeringknowledgehasnotbeenavailableforrotarydryersandasconsequencethesedryingunitsaregenerallyoverdesignedandthermallyinefficient.Thispaperdiscussesthedifferencebetweenarotarydryerandafluidbeddryerusedtodryslag1.Itisimportanttounderstandthedifferencebetweenthetwopiecesofequipmentandthedesignaspectsrequiredintherotarydryers.Oneofthedifficultieswiththedesignofrotarydryersisdeterminingtheamountofmaterialfallingthroughthegasstreamatanymomentintime.WorkcarriedoutbyWang,CameronandLister(1990)。Duetothecomplexityincalculatingthepercentageholdupinthegasstreamandthepercentageholdupintheliftervariouslifterdesignshavebeentriedovertheyearsonatrailanderrorbasis,manywithpoorresults.Becauseofcomplexityofestimatingsomeparametersmostrotarydryersareoverdesignedandasaconsequencethefinalproductcanbeoverdriedandheatedwastingthermalenergyandhigherthannecessaryequipmentcosts.WorkcarriedoutbyPalmerTechnologiesandTheUniversityofQueenslandhasbeenaimedatunderstandtheaspectsofdryinginarotarydryer.Thisworkenabledcomputermodelstobedevelopedandvalidatedagainstnumerousindustrialdryersinthesandandcementindustries.Theresultsfromdryingslagusingafluidbeddryerandarotarydryerarefirstcomparedfollowedbythedesigncriteriaforrotarydryersarediscussedinthispaper.DryinginGeneral1aby-productfromthesteelindustry2Thethreetypesofcontinuousdryersusedthroughoutindustryare,flashdryers,fluidbeddryersandrotarydryers.Withflashdryerstheheattransferfromthegastothesuspendedsolidsishigh,anddryingisrapid,withadryingtimeintheorderof3to4seconds.Fluidbeddryersalsohaveashortdryingtimethoughtheresidencetimeismorevariableandparticlesizedependent.Afluidbeddryerwillhaveanaverageresidencetimeofapproximately30to60seconds.Thethirdtypeofdryer,rotarydryers,hasalowheattransferrateincomparison.Theresidencetimeinarotaryunitvariesfromabout5to25minutesdependingontheproducttobedried.Figure1isatypicalvelocityversuspressuredropcurveassociatedwithfluidbedunits.Toachievefluidizationofapackedbedtheairvolumedragforcemustbeequaltothenetweightofsolidsinthebed.Figure1showstheincreaseinpressurewithgasvelocityandthepointatwhichfluidizationoccurs.Fluidbeddryerstakeadvantageofthesolidgascontactandthefactthatsolidparticlesarediscreteinthegasstream.Thedownsidewithfluidbedunitsisthehighelectricalenergyrequiredtomaintainthepressuredropacrossthebed.Mostdryerscanoperatewithagastemperaturewellabovetheboilingpointofwaterbutsomeproductsarelimitedforqualityreasons,egbreadcrumbs.Inthiscasedryersoperatingatlowgastemperatures,iebelowtheboilingpointofthefluidtobeevaporated,aremasstransferdominated.Whentheunitsareoperatedabovethefluidsboilingpointthenheattransferdominatesthedrying.Theeffectofgasvelocity,assumingnegligibleradiationandconduction,onthedryingrate(constantdryingrate,Nc)isproportionaltothegasmassvelocity,G,tothepowerof0.8(ie,G0.8).Theeffectofgastemperatureisdirectlyproportionaltotheenergytransferanddryingrate(Nc),thusincreasingthegastemperaturewillincreasethedryingrate.Theeffectofgashumidityonthedryingrateisinverselyproportional,thusasthegashumidityincreasesthedryingratedecreases(forconstantgastemperature).Figure1Variationofbedpressuredropversusfluidizingvelocity3Inthedryingofamaterialslikeslagsandaggregates,whichcanbehighlyporous,theremovalofmoistureisheattransferdominatedandthetransportoffreemoisturetothesurfaceiscontrolledbycapillarity.Aslongasthetransportofwatertothesurfaceoftheparticlekeepsthesurfacewetthedryingrateremainsconstant.Asdryingcontinuesthewaterlayerrecedesintotheparticleandthedryingratestartstofall.Apointisreachedwheretheinterfacialtensioninthecapillarybreaksandtheporefillswithair.Thisstateiscalledthependularstate.Atthispointthedryingratedecreasesrapidlyandthevaporizationrateisindependentofthefluidizingairvelocity.Thissorptioneffectisparticularlyimportantistheenergyrequirementtodrytheproductcanbesignificantlyhigherthantheheatofvapourization.Inthispapertwounitshavebeenevaluatedarotarydryerandafluidbeddryerbothdryingslag.EnergyBalanceoveraFluidBedDryerAsalreadymentionedafluidbeddryeroperatesontheprincipaloftheupwarddragforceonthepackedbedequalingtheweightofmaterialinthebed.Atthispointthebedwillstarttobecomefluidandintimatecontactisachievedbetweenthebedandthehotgas.Tomeasuretheefficiencyofthefluidbeddryeralltheinputstreamsaremeasuredandamassenergybalancewascalculated.InthiscasetheenergymassbalancewascarriedonaDorrOliverfluidbeddryer.Theunithasafluidbedcombustionzoneandthehotgasfromcoalcombustionpassesthroughthewetslagbed.Coalisusedbecauseofitverylowthermalenergycosts.TheenergybalancefiguresareshowninTable1.Thefiguresshowtheunithasaspecificenergyconsumptionofapproximately600MJ/twhichisconsideredquitegoodforslagwhichcanhaveamoisturecontentashighas16%.Alsotheenergybalanceshowsapproximately65%ofthethermalinputenergygoesinevaporationofthewaterandthespecificairrequirementsare0.33kgair/kgwetfeed.Table1MassenergybalancefluidbeddryerHeatInputHeatOutputMJ/h%MJ/h%Fluidizingair7173.219Exitgas(wet)3,68916.614Fuel19,81088.952Slag(dry)3,30614.887Convair35.170.158Rad&Conv.4401.982Overbedair135.350.608water(evap)14,76966.517Slag(wet)15737.063TOTAL22,270100.00TOTAL22,204100Reference00Cand1atm.TheelectricalenergyontheotherhandisapproximatelyXXkWh/t.EnergyBalanceoveraRotaryDryerTomeasuretheefficiencyoftherotaryalltheinputstreamsweremeasuredandamassenergybalancewascalculated.InthiscasetheenergymassbalancewascarriedonanArmstrongHollandrotarydryer.Measurementsonbothunitsweremeasuredusingavaneanemometerorapitottube.4AmassenergybalanceresultsonthedryerarepresentedinTableI.Theenergybalancegivesabreakdownofenergyontheoutputstreams.Ascanbeseenapproximately71percentoftheenergygoesintoevaporatingthewater.Thespecificairrequirementforthistypeofunitisapproximately0.22kgair/kgwetfeed.Table2MassenergybalanceonrotarydryerHeatInputHeatOutputMJ/h%MJ/h%Secondaryair1360.865Exitgas2,18013.918Fuel14,87494.439Product(dry)1,97312.596Falseair0.020.000Rad&Conv.3001.915Primaryair62.700.398water(evap)11,21271.571Feed(wet)6774.297TOTAL15,750100TOTAL15,666100Theelectricalenergywasmeasuredatapproximately0.13kWh/t.Thusitcanbeseenthatadvantagesexistswithrotarydryersiftheabetterunderstandingofthecriticalparametersassociatedwiththedesignofrotaryunitscanbeaachi
温馨提示
- 1. 本站所有资源如无特殊说明,都需要本地电脑安装OFFICE2007和PDF阅读器。图纸软件为CAD,CAXA,PROE,UG,SolidWorks等.压缩文件请下载最新的WinRAR软件解压。
- 2. 本站的文档不包含任何第三方提供的附件图纸等,如果需要附件,请联系上传者。文件的所有权益归上传用户所有。
- 3. 本站RAR压缩包中若带图纸,网页内容里面会有图纸预览,若没有图纸预览就没有图纸。
- 4. 未经权益所有人同意不得将文件中的内容挪作商业或盈利用途。
- 5. 人人文库网仅提供信息存储空间,仅对用户上传内容的表现方式做保护处理,对用户上传分享的文档内容本身不做任何修改或编辑,并不能对任何下载内容负责。
- 6. 下载文件中如有侵权或不适当内容,请与我们联系,我们立即纠正。
- 7. 本站不保证下载资源的准确性、安全性和完整性, 同时也不承担用户因使用这些下载资源对自己和他人造成任何形式的伤害或损失。
最新文档
- 2024届甘肃省定西市临洮县高三下学期开学假期学习质量检测数学试题(解析版)
- 网络信息安全计划
- 清华大学《431金融学综合》专业硕士历年考研真题汇编(含部分答案)合集
- 2024-2030中国电力信息化通信领域系统集成业务市场现状研究分析与发展前景预测报告
- 关于人员任命的通知(模板)
- 常见急性中毒患者的救护-有机磷中毒患者的急救(急救护理课件)
- 冲刺模拟卷03-【中职专用】备战2024年普通高职单考单招语文冲刺模拟卷(浙江适用)解析版
- 吉林省长春市七年级下学期英语期中试卷(含答案)2
- 2024年江苏省宿迁地区小升初语文高频考点模拟卷含答案
- 离婚协议的财产清算和分割
- 2024年长江生态环保集团有限公司招聘笔试参考题库含答案解析
- 雷达料位培训资料ppt课件
- 生理科学创新性实验家兔急性苯巴比妥中毒及其解救
- 合并报表抵消案例及分录
- 中药知识文库:安徽中草药
- 最新监理取费标准__670号文;
- 人教部编版八年级语文上册生字练习题
- 焊条用量比例(管道钢结构)
- 《生物柴油技术》PPT课件
- YSPA系列风冷螺杆式热泵机组
- 国家标准、行业标准及相关标准目录:摩托车标准
评论
0/150
提交评论