Netapp存储映射到AIX操作系统操作手册Netapp存储属于中高端的存储系统,它的FAS6220系统属于常见的带有FC和NAS功能的综合性存储,今天记录并讲解如何在AIX系统安装并操作NetAPP的多路径软件和lun磁盘的识别,查看;步骤如下;1,解压软件包 tar.zZcat ntap_aix_host_utilities_5.1.tar.Z |tar -xvf -2, 安装: installp +参数 +路径 +fileset 先安装MPIO,然后安装 santools_kittsm2:/tmp/ntap_aix_host_utilities_5.1/MPIO#installp -aXYd /tmp/ntap_aix_host_utilities_5.1/MPIO NetApp.MPIO_Host_Utilities_Kit+-+ Pre-installation Verification.+-+Verifying selections.doneVerifying requisites.doneResults.SUCCESSES- Filesets listed in this section passed pre-installation verification and will be installed. Selected Filesets - NetApp.MPIO_Host_Utilities_Kit.config 5.1.0.0 # NetApp MPIO PCM Host Utilities Kit Path Config Tool NetApp.MPIO_Host_Utilities_Kit.fcp 5.1.0.0 # NetApp MPIO PCM Host Utiliti. NetApp.MPIO_Host_Utilities_Kit.iscsi 5.1.0.0 # NetApp MPIO PCM Host Utilities Kit iSCSI Disk ODM Stanzas NetApp.MPIO_Host_Utilities_Kit.pcmodm 5.1.0.0 # NetApp MPIO PCM Host Utilities Kit PCM Friend ODM Stanzas +-+ BUILDDATE Verification .+-+Verifying build dates.doneFILESET STATISTICS - 4 Selected to be installed, of which: 4 Passed pre-installation verification - 4 Total to be installed0503-409 installp: bosboot verification starting.installp: bosboot verification completed.+-+ Installing Software.+-+installp: APPLYING software for: NetApp.MPIO_Host_Utilities_Kit.pcmodm 5.1.0.0 NetApp.MPIO_Host_Utilities_Kit.iscsi 5.1.0.0 NetApp.MPIO_Host_Utilities_Kit.fcp 5.1.0.0 NetApp.MPIO_Host_Utilities_Kit.config 5.1.0.0. . . . . . . . . . . . Copyright (c) 2003-2010 NetApp, Inc. . . . . . . . . sysck: 3001-036 WARNING: File /opt/NetApp/MPIO_Host_Utilities_Kit/NOTICE.PDF is also owned by fileset NetApp.MPIO_Host_Utilities_Kit.iscsi.sysck: 3001-036 WARNING: File /opt/NetApp/MPIO_Host_Utilities_Kit/NOTICE.TXT is also owned by fileset NetApp.MPIO_Host_Utilities_Kit.iscsi.Finished processing all filesets. (Total time: 6 secs).0503-409 installp: bosboot verification starting.installp: bosboot verification completed.0503-408 installp: bosboot process starting.bosboot: Boot image is 42972 512 byte blocks.0503-292 This update will not fully take effect until after a system reboot. * * * A T T E N T I O N * * * System boot image has been updated. You should reboot the system as soon as possible to properly integrate the changes and to avoid disruption of current functionality.installp: bosboot process completed.+-+ Summaries:+-+Installation Summary-Name Level Part Event Result-NetApp.MPIO_Host_Utilities_ 5.1.0.0 USR APPLY SUCCESS NetApp.MPIO_Host_Utilities_ 5.1.0.0 USR APPLY SUCCESS NetApp.MPIO_Host_Utilities_ 5.1.0.0 USR APPLY SUCCESS NetApp.MPIO_Host_Utilities_ 5.1.0.0 USR APPLY SUCCESS tsm2:/tmp/ntap_aix_host_utilities_5.1/MPIO#lslpp -l |grep -i netapp NetApp.MPIO_Host_Utilities_Kit.config 5.1.0.0 COMMITTED NetApp MPIO PCM Host Utilities NetApp.MPIO_Host_Utilities_Kit.fcp 5.1.0.0 COMMITTED NetApp MPIO PCM Host Utilities NetApp.MPIO_Host_Utilities_Kit.iscsi 5.1.0.0 COMMITTED NetApp MPIO PCM Host Utilities NetApp.MPIO_Host_Utilities_Kit.pcmodm 5.1.0.0 COMMITTED NetApp MPIO PCM Host Utilitiestsm2:/tmp/ntap_aix_host_utilities_5.1/MPIO#cd .tsm2:/tmp/ntap_aix_host_utilities_5.1#pwd/tmp/ntap_aix_host_utilities_5.1tsm2:/tmp/ntap_aix_host_utilities_5.1#lsMPIO SAN SAN_Tool_Kittsm2:/tmp/ntap_aix_host_utilities_5.1#cd *ittsm2:/tmp/ntap_aix_host_utilities_5.1/SAN_Tool_Kit#pwd/tmp/ntap_aix_host_utilities_5.1/SAN_Tool_Kittsm2:/tmp/ntap_aix_host_utilities_5.1/SAN_Tool_Kit#installp -aXYd /tmp/ntap_aix_host_utilities_5.1/MPIO NetApp.MPIO_Host_Utilities_Kittsm2:/tmp/ntap_aix_host_utilities_5.1/SAN_Tool_Kit#installp -aXYd /tmp/ntap_aix_host_utilities_5.1/SAN_Tool_Kit tsm2:/tmp/ntap_aix_host_utilities_5.1/SAN_Tool_Kit#lsNetApp.SAN_toolkittsm2:/tmp/ntap_aix_host_utilities_5.1/SAN_Tool_Kit#installp -aXYd /tmp/ntap_aix_host_utilities_5.1/SAN_Tool_Kit NetApp.SAN_toolkit+-+ Pre-installation Verification.+-+Verifying selections.doneVerifying requisites.doneResults.SUCCESSES- Filesets listed in this section passed pre-installation verification and will be installed. Selected Filesets - NetApp.SAN_toolkit.sanlun 5.1.0.0 # NetApp SAN Toolkit sanlun +-+ BUILDDATE Verification .+-+Verifying build dates.doneFILESET STATISTICS - 1 Selected to be installed, of which: 1 Passed pre-installation verification - 1 Total to be installed+-+ Installing Software.+-+installp: APPLYING software for: NetApp.SAN_toolkit.sanlun 5.1.0.0. . . . . . . . . . . . Copyright (c) 2003-2010 NetApp, Inc. . . . . . . . . Finished processing all filesets. (Total time: 1 secs).+-+ Summaries:+-+Installation Summary-Name Level Part Event Result-NetApp.SAN_toolkit.sanlun 5.1.0.0 USR APPLY SUCCESS tsm2:/tmp/ntap_aix_host_utilities_5.1/SAN_Tool_Kit#tsm2:/tmp/ntap_aix_host_utilities_5.1/SAN_Tool_Kit#tsm2:/tmp/ntap_aix_host_utilities_5.1/SAN_Tool_Kit#tsm2:/tmp/ntap_aix_host_utilities_5.1/SAN_Tool_Kit#tsm2:/tmp/ntap_aix_host_utilities_5.1/SAN_Tool_Kit#tsm2:/tmp/ntap_aix_host_utilities_5.1/SAN_Tool_Kit#which sanlun/usr/bin/sanluntsm2:/tmp/ntap_aix_host_utilities_5.1/SAN_Tool_Kit#cd /opt/NetApptsm2:/opt/NetApp#lsMPIO_Host_Utilities_Kit santoolstsm2:/opt/NetApp#cd santoolstsm2:/opt/NetApp/santools#lsNOTICE.PDF NOTICE.TXT bin mantsm2:/opt/NetApp/santools#cd bintsm2:/opt/NetApp/santools/bin#lssan_version sanluntsm2:/opt/NetApp/santools/bin#sanlun lun show no controller LUNs availabletsm2:/opt/NetApp/santools/bin#tsm2:/opt/NetApp/santools/bin#tsm2:/opt/NetApp/santools/bin#cfgmgr -v #存储那边配置好,映射好后,AIX开始扫描cfgmgr is running in phase 2tsm2:/opt/NetApp/santools/bin#tsm2:/opt/NetApp/santools/bin#tsm2:/opt/NetApp/santools/bin#lspvhdisk0 00c59412a7d7466a rootvg activehdisk1 00c3afa442c5c5f6 rootvg activehdisk2 none None hdisk3 none None hdisk4 none None hdisk5 none None hdisk6 none None hdisk7 none None hdisk8 none None hdisk9 none None hdisk10 none None hdisk11 none None tsm2:/opt/NetApp/santools/bin#用sanlun 命令查看其实还需要设置磁盘属性,要看netapp的官方文档设置deep ,queue_depth等;tsm2:/opt/NetApp/santools/bin#sanlun lun showcontroller: lun-pathname device filename adapter protocol lun size lun state FAS6220-2A: /vol/lun1_aix_tsm_vol/aix_tsm_06 hdisk10 fcs0 FCP 500.1g (536952700928) GOOD FAS6220-2A: /vol/lun1_aix_tsm_vol/aix_tsm_07 hdisk11 fcs0 FCP 500.1g (536952700928) GOOD FAS6220-2A: /vol/lun1_aix_tsm_vol/aix_tsm_00 hdisk4 fcs0 FCP 500.1g (536952700928) GOOD FAS6220-2A: /vol/lun1_aix_tsm_vol/aix_tsm_01 hdisk5 fcs0 FCP 500.1g (536952700928) GOOD FAS6220-2A: /vol/lun1_aix_tsm_vol/aix_tsm_02 hdisk6 fcs0 FCP 500.1g (536952700928) GOOD FAS6220-2A: /vol/lun1_aix_tsm_vol/aix_tsm_03 hdisk7 fcs0 FCP 500.1g (536952700928) GOOD FAS6220-2A: /vol/lun1_aix_tsm_vol/aix_tsm_04 hdisk8 fcs0 FCP 500.1g (536952700928) GOOD FAS6220-2A: /vol/lun1_aix_tsm_vol/aix_tsm_05 hdisk9 fcs0 FCP 500.1g (536952700928) GOOD tsm2:/opt/NetApp/santools/bin#lsdev -Cc diskhdisk0 Available 01-08-00 SAS Disk Drivehdisk1 Available 01-08-00 SAS Disk Drivehdisk2 Available 01-08-00 SAS Disk Drivehdisk3 Available 01-08-00 SAS Disk Drivehdisk4 Available 05-00-02 MPIO NetApp FCP Default PCM Diskhdisk5 Available 05-00-02 MPIO NetApp FCP Default PCM Diskhdisk6 Available 05-00-02 MPIO NetApp FCP Default PCM Diskhdisk7 Available 05-00-02 MPIO NetApp FCP Default PCM Diskhdisk8 Available 05-00-02 MPIO NetApp FCP Default PCM Diskhdisk9 Available 05-00-02 MPIO NetApp FCP Default PCM Diskhdisk10 Available 05-00-02 MPIO NetApp FCP Default PCM Diskhdisk11 Available 05-00-02 MPIO NetApp FCP Default PCM Disktsm2:/opt/NetApp/santools/bin#sanlun lun show -p # -p 参数查看多路径状态ONTAP_PATH: FAS6220-2A:/vol/lun1_aix_tsm_vol/aix_tsm_05LUN: 5LUN Size: 500.1g (536952700928) Host Device: hdisk9LUN State: GOODController_CF_State: Cluster EnabledController Partner: FAS6220-2BMultipath Provider: AIX NativeMultipathing Algorithm: round_robin- - - - - -MPIO Controller AIX Controller AIX MPIO path path MPIO host target HBA path status type path HBA port priority - - - - - -Enabled primary path0 fcs0 0a 1Enabled secondary path1 fcs0 0a 1Enabled primary path2 fcs0 1c 1Enabled secondary path3 fcs0 1a 1Enabled primary path4 fcs2 0b 1Enabled secondary path5 fcs2 0b 1Enabled primary path6 fcs2 1a 1Enabled secondary path7 fcs2 1c 1ONTAP_PATH: FAS6220-2A:/vol/lun1_aix_tsm_vol/aix_tsm_04LUN: 4LUN Size: 500.1g (536952700928) Host Device: hdisk8LUN State: GOODController_CF_State: Cluster EnabledController Partner: FAS6220-2BMultipath Provider: AIX NativeMultipathing Algorithm: round_robin- - - - - -MPIO Controller AIX Controller AIX MPIO path path MPIO host target HBA path status type path HBA port priority - - - - - -Enabled primary path0 fcs0 0a 1Enabled secondary path1 fcs0 0a 1Enabled primary path2 fcs0 1c 1Enabled secondary path3 fcs0 1a 1Enabled primary path4 fcs2 0b 1Enabled secondary path5 fcs2 0b 1Enabled primary path6 fcs2 1a 1Enabled secondary path7 fcs2 1c 1ONTAP_PATH: FAS6220-2A:/vol/lun1_aix_tsm_vol/aix_tsm_03LUN: 3LUN Size: 500.1g (536952700928) Host Device: hdisk7LUN State: GOODController_CF_State: Cluster EnabledController Partner: FAS6220-2BMultipath Provider: AIX NativeMultipathing Algorithm: round_robin- - - - - -MPIO Controller AIX Controller AIX MPIO path path MPIO host target HBA path status type path HBA port priority - - - - - -Enabled primary path0 fcs0 0a 1Enabled secondary path1 fcs0 0a 1Enabled primary path2 fcs0 1c 1Enabled secondary path3 fcs0 1a 1Enabled primary path4 fcs2 0b 1Enabled secondary path5 fcs2 0b 1Enabled primary path6 fcs2 1a 1Enabled secondary path7 fcs2 1c 1ONTAP_PATH: FAS6220-2A:/vol/lun1_aix_tsm_vol/aix_tsm_02LUN: 2LUN Size: 500.1g (536952700928) Host Device: hdisk6LUN State: GOODController_CF_State: Cluster EnabledController Partner: FAS6220-2BMultipath Provider: AIX NativeMultipathing Algorithm: round_robin- - - - - -MPIO Controller AIX Controller AIX MPIO path path MPIO host target HBA path status type path HBA port priority - - - - - -Enabled primary path0 fcs0 0a 1Enabled secondary path1 fcs0 0a 1Enabled primary path2 fcs0 1c 1Enabled secondary path3 fcs0 1a 1Enabled primary path4 fcs2 0b 1Enabled secondary path5 fcs2 0b 1Enabled primary path6 fcs2 1a 1Enabled secondary path7 fcs2 1c 1ONTAP_PATH: FAS6220-2A:/vol/lun1_aix_tsm_vol/aix_tsm_01LUN: 1LUN Size: 500.1g (536952700928) Host Device: hdisk5LUN State: GOODController_CF_State: Cluster EnabledController Partner: FAS6220-2BMultipath Provider: AIX NativeMultipathing Algorithm: round_robin- - - - - -MPIO Controller AIX Controller AIX MPIO path path MPIO host target HBA path status type path HBA port priority - - - - - -Enabled primary path0 fcs0 0a 1Enabled secondary path1 fcs0 0a 1Enabled primary path2 fcs0 1c 1Enabled secondary path3 fcs0 1a 1Enabled primary path4 fcs2 0b 1Enabled secondary path5 fcs2 0b 1Enabled primary path6 fcs2 1a 1Enabled secondary path7 fcs2 1c 1ONTAP_PATH: FAS6220-2A:/vol/lun1_aix_tsm_vol/aix_tsm_00LUN: 0LUN Size: 500.1g (536952700928) Host Device: hdisk4LUN State: GOODController_CF_State: Cluster EnabledController Partner: FAS6220-2BMultipath Provider: AIX NativeMultipathing Algorithm: round_robin- - - - - -MPIO Controller AIX Controller AIX MPIO path path MPIO host target HBA path status type path HBA port priority - - - - - -Enabled primary path0 fcs0 0a 1Enabled secondary path1 fcs0 0a 1Enabled primary path2 fcs0 1c 1Enabled secondary path3 fcs0 1a 1Enabled primary path4 fcs2 0b 1Enabled secondary path5 fcs2 0b 1Enabled primary path6 fcs2 1a 1Enabled secondary path7 fcs2 1c 1ONTAP_PATH: FAS6220-2A:/vol/lun1_aix_tsm_vol/aix_tsm_07LUN: 7LUN Size: 500.1g (536952
温馨提示
- 1. 本站所有资源如无特殊说明,都需要本地电脑安装OFFICE2007和PDF阅读器。图纸软件为CAD,CAXA,PROE,UG,SolidWorks等.压缩文件请下载最新的WinRAR软件解压。
- 2. 本站的文档不包含任何第三方提供的附件图纸等,如果需要附件,请联系上传者。文件的所有权益归上传用户所有。
- 3. 本站RAR压缩包中若带图纸,网页内容里面会有图纸预览,若没有图纸预览就没有图纸。
- 4. 未经权益所有人同意不得将文件中的内容挪作商业或盈利用途。
- 5. 人人文库网仅提供信息存储空间,仅对用户上传内容的表现方式做保护处理,对用户上传分享的文档内容本身不做任何修改或编辑,并不能对任何下载内容负责。
- 6. 下载文件中如有侵权或不适当内容,请与我们联系,我们立即纠正。
- 7. 本站不保证下载资源的准确性、安全性和完整性, 同时也不承担用户因使用这些下载资源对自己和他人造成任何形式的伤害或损失。
最新文档
- 宣城市中医院肝癌合并肝硬化患者手术决策与风险评估考核
- 宿迁市人民医院特殊体位摄影考核
- 泰州市中医院椎间盘射频消融术考核
- 济南市人民医院内镜下黏膜切除术操作医师分级考核标准
- 抚州市中医院慢性病用药管理考核
- 济南市人民医院复杂动脉瘤介入考核
- 济南市中医院术中神经监测考核
- 盐城市中医院老年医学科安全管理制度考核
- 嘉兴市人民医院居民健康档案的质量控制考核
- 泰州市人民医院儿童早期矫治考核
- 住院患者安全风险评估与防范
- 3.2函数与方程不等式之间的关系第1课时-高一上学期数学人教B版
- 青岛版二年级数学上册第六单元“用2-6的乘法口诀求商”教学设计
- 学校、托幼机构传染病防控卫生监督及法律法规-培训课件
- 化工单元操作工作业指导书
- 学校班长培训课件
- lng应急预案安全培训课件
- 2024年安全学院危险性较高企业安全管理人员业务能力培训测试考试真题
- 2024年注册安全工程师考试真题及答案(完整版)
- 公路养护机械管理方案(3篇)
- 消息写作课程讲解
评论
0/150
提交评论