免费预览已结束,剩余1页可下载查看
下载本文档
版权说明:本文档由用户提供并上传,收益归属内容提供方,若内容存在侵权,请进行举报或认领
文档简介
天拓电子科技 /16 Channel Bluetooth relay manual Product Features:1 Operating voltage: DC 12V2 Operating Current: Standby current (all relays closed) 14MA, 1 relay open 41MA, 2 relays open 69MA, 3 relays open 96MA, 4 relays open 123MA,5 relays open 150MA,6 relays open 177MA,7 relays open 203MA,8 relays open 229MA.16 relays open 480mA3: send commands via Android Bluetooth APP control relay turned on and off (we provide Bluetooth APP, you can also use your own APP to control relays, sending commands to control)4 Momentary Self-locking Interlock open close 5 Commands5 You can modify the Bluetooth name and PIN(Access Password) through AT commands, For details, see file Bluetooth parameter modification6 size 175*65*19mm7 Weight : 222gGlossary:NO : Relay normally open contactCOM : Relay common contactNC : Relay normally closed contactMomentary : Mobile terminal input A0 (B0 / C0 / D0 is the same), the relay is open,and after delay of 1 second the relay is Close.Self-locking : Mobile terminal input A1, the relay is Open, input A1, the relay is Close, and so onInterlock : Mobile terminal input A2, relay 1 is Open, the other relay is Close; input B2, relay 2 is Open, the other relay is Close, and so on.Open : NO connection COM, NC disconnect COMClose : NO disconnect COM, NC connection COMCommandS (Format: character, case-insensitive)CommandSFeaturesDescriptionA0CH1 MomentaryMobile terminal input A0, the relay is open,and after delay of 1 second the relay is Close.A1CH1 Self-locking Mobile terminal input A1, the relay is Open, input A1, the relay is Close, and so onA2CH1 Interlock Mobile terminal input A2, relay 1 is Open, the other relay is Close; Input B2/C2/D2 relay 1 is CloseA3CH1 Open NO1 connection COM1, NC1 disconnect COM1A4CH1 Close NO1 disconnect COM1, NC1 connection COM1B0CH2 MomentaryMobile terminal input B0, the relay is open,and after delay of 1 second the relay is Close.B1CH2 Self-locking Mobile terminal input B1, the relay is Open, input B1, the relay is Close, and so onB2CH2 Interlock Mobile terminal input B2, relay 2 is Open, the other relay is Close; Input A2/C2/D2 relay 2 is CloseB3CH2 Open NO2 connection COM2, NC2 disconnect COM2B4CH2 Close NO2 disconnect COM2, NC2 connection COM2C0CH3 MomentaryMobile terminal input C0, the relay is open,and after delay of 1 second the relay is Close.C1CH3 Self-locking Mobile terminal input C1, the relay is Open, input C1, the relay is Close, and so onC2CH3 Interlock Mobile terminal input C2, relay 3 is Open, the other relay is Close; Input A2/B2/D2 relay 3 is CloseC3CH3 Open NO3 connection COM3, NC3 disconnect COM3C4CH3 Close NO3 disconnect COM3, NC3 connection COM3D0CH4 MomentaryMobile terminal input D0, the relay is open,and after delay of 1 second the relay is Close.D1CH4 Self-locking Mobile terminal input D1, the relay is Open, input D1, the relay is Close, and so onD2CH4 Interlock Mobile terminal input D2, relay 4 is Open, the other relay is Close; Input A2/B2/C2 relay 4 is CloseD3CH4 Open NO4 connection COM4, NC4 disconnect COM4D4CH4 Close NO4 disconnect COM4, NC4 connection COM4E0CH5 MomentaryMobile terminal input E0, the relay is open,and after delay of 1 second the relay is Close.E1CH5 Self-locking Mobile terminal input E1, the relay is Open, input E1, the relay is Close, and so onE2CH5 Interlock Mobile terminal input E2, relay 5 is Open, the other relay is Close; Input A2/B2/C2/D2/F2/H2/I2 relay 5 is CloseE3CH5 Open NO5 connection COM5, NC5 disconnect COM5E4CH5 Close NO5 disconnect COM5, NC5 connection COM5F0CH6 MomentaryMobile terminal input F0, the relay is open,and after delay of 1 second the relay is Close.F1CH6 Self-locking Mobile terminal input F1, the relay is Open, input F1, the relay is Close, and so onF2CH6 Interlock Mobile terminal input F2, relay 6 is Open, the other relay is Close; Input A2/B2/C2/D2/E2/H2/I2 relay 6 is CloseF3CH6 Open NO6 connection COM6, NC6 disconnect COM6F4CH6 Close NO6 disconnect COM6, NC6 connection COM6G0CH7 MomentaryMobile terminal input H0, the relay is open,and after delay of 1 second the relay is Close.G1CH7 Self-locking Mobile terminal input H1, the relay is Open, input H1, the relay is Close, and so onG2CH7 Interlock Mobile terminal input H2, relay 7 is Open, the other relay is Close; Input A2/B2/C2/D2/E2/F2/I2 relay 7 is CloseG3CH7 Open NO7 connection COM7, NC7 disconnect COM7G4CH7 Close NO7 disconnect COM7, NC7 connection COM7H0CH8 MomentaryMobile terminal input I0, the relay is open,and after delay of 1 second the relay is Close.H1CH8 Self-locking Mobile terminal input I1, the relay is Open, input I1, the relay is Close, and so onH2CH8 Interlock Mobile terminal input I2, relay 8 is Open, the other relay is Close; Input A2/B2/C2/D2/E2/F2/H2 relay 8 is CloseH3CH8 Open NO8 connection COM8, NC8 disconnect COM8H4CH8 Close NO8 disconnect COM8, NC8 connection COM8CH9-CH16 Command is I1/J1/K1/L1/M1/N1/O1/P1Bluetooth APP operations:Access Password:1234Bluetooth Baud rate: 9600BPSVideo:see 4CH Bluetooth Relay V3 DemoTypical applications:1 DC 12V con
温馨提示
- 1. 本站所有资源如无特殊说明,都需要本地电脑安装OFFICE2007和PDF阅读器。图纸软件为CAD,CAXA,PROE,UG,SolidWorks等.压缩文件请下载最新的WinRAR软件解压。
- 2. 本站的文档不包含任何第三方提供的附件图纸等,如果需要附件,请联系上传者。文件的所有权益归上传用户所有。
- 3. 本站RAR压缩包中若带图纸,网页内容里面会有图纸预览,若没有图纸预览就没有图纸。
- 4. 未经权益所有人同意不得将文件中的内容挪作商业或盈利用途。
- 5. 人人文库网仅提供信息存储空间,仅对用户上传内容的表现方式做保护处理,对用户上传分享的文档内容本身不做任何修改或编辑,并不能对任何下载内容负责。
- 6. 下载文件中如有侵权或不适当内容,请与我们联系,我们立即纠正。
- 7. 本站不保证下载资源的准确性、安全性和完整性, 同时也不承担用户因使用这些下载资源对自己和他人造成任何形式的伤害或损失。
最新文档
- 粗纱工操作技能能力考核试卷含答案
- 学习师德师风心得体会(信息技术教师版)
- 加气混凝土配料浇注工操作规程测试考核试卷含答案
- 平路机司机岗前基础效率考核试卷含答案
- 化工结晶工诚信品质测试考核试卷含答案
- 《GBT 2609-2015 显微镜 物镜》专题研究报告
- 铅笔制造工安全宣教测试考核试卷含答案
- 《GBT 35497-2017 胶鞋 胶鞋用材料阻燃性能试验方法》专题研究报告
- 拖拉机锻造加工生产线操作调整工岗前规章考核试卷含答案
- 数控等离子切割机操作工安全理论水平考核试卷含答案
- RhD阴性孕产妇的合理输血讲课分享
- 2024年02月深圳市坪山区融媒体中心2024年公开招考12名工作人员笔试近年2018-2023典型考题及考点剖析附答案带详解
- 疼痛学临床诊疗指南
- 高中英语选择性必修一《Unit 1 People of achievement》单元教学设计
- 动物给药技术(动物临床诊疗课件)
- 波西杰克逊系列
- 采伐操作规程培训课件
- 《工业通风与除尘》课程标准
- 光泽县城乡供水一体化工程环境影响报告表
- 职业倦怠量表MBI-HSS
- 国网超市化招标评标自动计算表(区间复合平均价法)
评论
0/150
提交评论