管路系统标识规则Rules of Piping Labeling System一、 订定管路标示密度、标示颜色及标签大小,是为了使人员容易辨别,以降低风险。管路标示适用于Michelin Phase 1车间,厂务机房,仓库,废水处理厂,中央供给系统等管路系统。(如:Water, Exhaust, Drain, Gas, Chemical, Vacuum, Special gas等)。The number, colors and size of piping Labels, which people can easy find the system, and reduce risk. The piping labeling system is suitable for the piping systems, which in Shops, Facility Rooms, Storage Rooms, Waste water Treatment Plant, Central Utility Building(CUB), etc.二、 标签分类1、 标签颜色:用于表示管内物质特性颜色。(Label Color: Indicates the substance inside the piping)2、 文字:说明内容物质的名称。(Text: Indicates the name of the substance)3、 箭头记号:用于表示管内物质流动方向。(Arrow Symbol: Indicates the flow direction inside piping)4、 底色意义 (Meaning of the label color):(1) 红色 危险色,表示内容物有毒性,很强或易燃,高温与消防。(Red Dangerous, means Substance is very poisonous, easy to burn, high temperature and fire fighting.)(2) 橙色/黄色 警告色,表示内容物有毒性,腐蚀性或混水、废水等对人有害者。(Orange/Yellow Warning, means Substance is poisonous, corrosive, warm water, waste water etc.)(3) 蓝色/绿色散- 安全色,表示内容物质危险性较小或没有危险(Blue/Green Safe, means Substance is almost not dangerous or safe.)三、 识别标示张贴规定 (Labeling Location Rules):(保温管道的管径及保温外外径计算,无保温管道以外径计算) 风管底部贴标签时按风管底部的宽度计算,上下风管重叠无法张贴时需要贴在侧面容易识别处)(1) 水平直管部分 (Horizontal Straight Piping):管路内径100mm(含)以下:以主要走道上方为基准位张贴一张,再向两侧延伸每隔6m张贴一张。(Piping is or Smaller than DN100: Paste one label on each pipe on main corridor first, then paste the labels in every 6 meters.)管路内径100mm(不含)以上:以主要走道上方为基准位张贴一张,再向两侧延伸每隔10m张贴一张。(Piping is Bigger than DN100: Paste one label on each pipe on main corridor, then paste the labels in every 10 meters.)(2) 垂直直管 (Vertical Straight Piping):所有管道(风管及水管):由地板算起150公分处为基准位张贴一张(标签上缘对齐150公分),再上下延伸每隔6m张贴一张。(每层楼板都按此计算)(Piping is or Smaller than DN100: Paste one label on each pipe 150mm above the floor (from the floor to the top of label is 150cm), then paste the labels in every 6 meters.)(3) 三通及弯头转弯处:三通处及转弯处管道便签作为新起点重新开始标识。(4) 上列管路于阀件,弯头及穿墙两侧部分皆需张贴;管路连接机台时,需于机台接管处再贴一张。(Both sides of the valves, elbows and the penetrations must be labeled; and paste one label more where the pipe connect to equipment.)(5) 若为整排管路应注意标示张贴之整齐性。 水平管路各管系标签中心相互对齐。 垂直管路上缘对齐。( Should always keep the regulation of the labels. For the horizontal piping system, the centers of all labels must be in one line; for the vertical piping system, the tops of all labels must be in one line.)(6) 张贴视角 (attitude) 须符合人因工程,且标示文字不可上下颠倒,使人员于操作或紧急应变时能够迅速目击及辨认。(All the labels must be easy to see, and do not make the texts upside down, in order to see it very easy and clear in short time in emergency.)(7) 管路标示,请依据本规则办理,若有新增标示名称,应先与米其林讨论决定其样式。(Please do all the piping labeling system according to this rule; if there is any new system, please contact the relative department of Michelin)四、 卷标图标尺寸 (Attachment 2: Label Size) :Outside diameter ofLabel Size (mm)Lable samplePipe / Duct (mm)Rectangular Long X WideNo. 250480 X 100#1见附件图纸:Michelin-Mechanical-Label-01五、 颜色之指定 及文字描述不保温管道涂刷面漆颜色、保温及不保温管道涂刷管道标识符的要求按下表执行。The coated color of finishing paint for un-insulated piping, coated piping mark for insulated and un-insulated piping shall accord with the table below.5.1管道系统:序号No.管道名称Piping name面漆或色环颜色Color of finishing paint or colored ring标识 Mark 1压缩空气管道Compressed air piping淡蓝色Light blueJFM316压缩空气(CA)Compressed air(CA)2工艺冷却水管道Process cooling water piping墨绿色环Black green ringJFM509工艺冷却水供水(PCW)Process cooling water supply工艺冷却水回水(PCWR)Process cooling water return3塔冷却水管道Tower cooling water piping墨绿色Black greenJFM509塔冷却水供水(TCW)Tower cooling water supply塔冷却水回水(TCWR)Tower cooling water return4消防水管道Fire water piping自动喷淋给水Sprinkling water piping红色RedJFM107消防用水(FW)Fire water喷淋水(SPK)Sprinkling water5气体灭火送气管红色red JFM107灭火气体(FG)6自来水管道City water piping工业水管Industry water piping墨绿色环Black green ringJFM509自来水(CW)City water 工业水(IW)Industry water7冷冻水管道Chilled water piping墨绿色环Black green ringJFM509冷冻水供水(CCHW)Chilled water supply冷冻水回水(CCHWR)Chilled water return8工艺热水管道Process hot water piping红色环red ringJFM107工艺热水供水(PHW)Process hot water supply工艺热水回水(PHWR)Process hot water return9液压水管道Hydraulic pressure water piping墨绿色Black green液压水供水(HPW)Hydraulic pressure water supply液压水回水(HPWR)Hydraulic pressure water return10卫生热水Sanitary hot water piping桔红环Red ringJFM109卫生热水供(SHW)Sanitary hot water supply卫生热水回(SHWR)Sanitary hot water return11软化水管Softened water piping纯水管Pured water piping墨绿色环JFM509软化水(SW) Softened water纯水供(OW) Pured water纯水回(OWR) Pured water return12蒸汽管道Steam piping红色环Red ringJFM107生产蒸汽管(S XXb)Steam piping for production采暖蒸汽管(S XXb)Steam piping for heating13蒸气凝结水管道Steam condensate piping红色环red ringJFM107蒸气凝结水(S)Steam condensate14真空管道 Vacuum piping淡蓝色Light blueJFM314真空(V)Vacuum15锅炉给水管Boiler feed water piping锅炉连续排污管 Continuous boiler blowdown piping锅炉定期排污管 Peroidical boiler blowdown piping除氧水管 De-oxidation water piping墨绿色环JFM509锅炉给水(BFW)oiler feed water锅炉连续排污(CBD)Continuous boiler blowdown锅炉定期排污(PBD) Peroidical boiler blowdown 除氧水(DOW)De-oxidation water16煤气管Coal gas piping淡黄Light yellowJFM213煤气(CG)Coal gas17汽油管Gasoline piping工艺油管Process oil piping黄色YellowJFM213溶剂油(G)solvent1#工艺油供(PO1) N1 process oil supply1#工艺油回(POR1)N1 process oil return2#工艺油供(PO2)N2 process oil supply2#工艺油回(POR2)N2 pr

温馨提示

  • 1. 本站所有资源如无特殊说明,都需要本地电脑安装OFFICE2007和PDF阅读器。图纸软件为CAD,CAXA,PROE,UG,SolidWorks等.压缩文件请下载最新的WinRAR软件解压。
  • 2. 本站的文档不包含任何第三方提供的附件图纸等,如果需要附件,请联系上传者。文件的所有权益归上传用户所有。
  • 3. 本站RAR压缩包中若带图纸,网页内容里面会有图纸预览,若没有图纸预览就没有图纸。
  • 4. 未经权益所有人同意不得将文件中的内容挪作商业或盈利用途。
  • 5. 人人文库网仅提供信息存储空间,仅对用户上传内容的表现方式做保护处理,对用户上传分享的文档内容本身不做任何修改或编辑,并不能对任何下载内容负责。
  • 6. 下载文件中如有侵权或不适当内容,请与我们联系,我们立即纠正。
  • 7. 本站不保证下载资源的准确性、安全性和完整性, 同时也不承担用户因使用这些下载资源对自己和他人造成任何形式的伤害或损失。

评论

0/150

提交评论