




文档简介
BSENISO99062012BSISTANDARDSPUBLICATIONROTODYNAMICPUMPSHYDRAULICPERFORMANCEACCEPTANCETESTSGRADES1,2AND3ISO99062012NOCOPYINGWITHOUTBSIPERMISSIONEXCEPTASPERMITTEDBYCOPYRIGHTLAWRAISINGSTANDARDSWORLDWIDEBSENISO99062012BRITISHSTANDARDNATIONALFOREWORDTHISBRITISHSTANDARDISTHEUKIMPLEMENTATIONOFENISO99062012ITSUPERSEDESBSENISO99062000WHICHISWITHDRAWNTHEUKPARTICIPATIONINITSPREPARATIONWASENTRUSTEDTOTECHNICALCOMMITTEEMCE/6,PUMPSANDPUMPTESTINGALISTOFORGANIZATIONSREPRESENTEDONTHISCOMMITTEECANBEOBTAINEDONREQUESTTOITSSECRETARYTHISPUBLICATIONDOESNOTPURPORTTOINCLUDEALLTHENECESSARYPROVISIONSOFACONTRACTUSERSARERESPONSIBLEFORITSCORRECTAPPLICATIONTHEBRITISHSTANDARDSINSTITUTION2012PUBLISHEDBYBSISTANDARDSLIMITED2012ISBN9780580588327ICS23080COMPLIANCEWITHABRITISHSTANDARDCANNOTCONFERIMMUNITYFROMLEGALOBLIGATIONSTHISBRITISHSTANDARDWASPUBLISHEDUNDERTHEAUTHORITYOFTHESTANDARDSPOLICYANDSTRATEGYCOMMITTEEON31MAY2012AMENDMENTSISSUEDSINCEPUBLICATIONDATETEXTAFFECTEDEUROPEANSTANDARDNORMEEUROPENNEENISO9906EUROPISCHENORMMAY2012ICS23080SUPERSEDESENISO99061999ENGLISHVERSIONROTODYNAMICPUMPSHYDRAULICPERFORMANCEACCEPTANCETESTSGRADES1,2AND3ISO99062012POMPESROTODYNAMIQUESESSAISDEFONCTIONNEMENTKREISELPUMPENHYDRAULISCHEABNAHMEPRFUNGKLASSENHYDRAULIQUEPOURLARCEPTIONNIVEAUX1,2ET3ISO1,2UND3ISO9906201299062012THISEUROPEANSTANDARDWASAPPROVEDBYCENON16MARCH2012CENMEMBERSAREBOUNDTOCOMPLYWITHTHECEN/CENELECINTERNALREGULATIONSWHICHSTIPULATETHECONDITIONSFORGIVINGTHISEUROPEANSTANDARDTHESTATUSOFANATIONALSTANDARDWITHOUTANYALTERATIONUPTODATELISTSANDBIBLIOGRAPHICALREFERENCESCONCERNINGSUCHNATIONALSTANDARDSMAYBEOBTAINEDONAPPLICATIONTOTHECENCENELECMANAGEMENTCENTREORTOANYCENMEMBERTHISEUROPEANSTANDARDEXISTSINTHREEOFFICIALVERSIONSENGLISH,FRENCH,GERMANAVERSIONINANYOTHERLANGUAGEMADEBYTRANSLATIONUNDERTHERESPONSIBILITYOFACENMEMBERINTOITSOWNLANGUAGEANDNOTIFIEDTOTHECENCENELECMANAGEMENTCENTREHASTHESAMESTATUSASTHEOFFICIALVERSIONSCENMEMBERSARETHENATIONALSTANDARDSBODIESOFAUSTRIA,BELGIUM,BULGARIA,CROATIA,CYPRUS,CZECHREPUBLIC,DENMARK,ESTONIA,FINLAND,FRANCE,GERMANY,GREECE,HUNGARY,ICELAND,IRELAND,ITALY,LATVIA,LITHUANIA,LUXEMBOURG,MALTA,NETHERLANDS,NORWAY,POLAND,PORTUGAL,ROMANIA,SLOVAKIA,SLOVENIA,SPAIN,SWEDEN,SWITZERLAND,TURKEYANDUNITEDKINGDOMEUROPEANCOMMITTEEFORSTANDARDIZATIONCOMITEUROPENDENORMALISATIONEUROPISCHESKOMITEEFRNORMUNGMANAGEMENTCENTREAVENUEMARNIX17,B1000BRUSSELS2012CENALLRIGHTSOFEXPLOITATIONINANYFORMANDBYANYMEANSRESERVEDREFNOENISO99062012EWORLDWIDEFORCENNATIONALMEMBERSBSENISO99062012ENISO99062012EFOREWORDTHISDOCUMENTENISO99062012HASBEENPREPAREDBYTECHNICALCOMMITTEEISO/TC115“PUMPS“INCOLLABORATIONWITHTECHNICALCOMMITTEECEN/TC197“PUMPS”THESECRETARIATOFWHICHISHELDBYAFNORTHISEUROPEANSTANDARDSHALLBEGIVENTHESTATUSOFANATIONALSTANDARD,EITHERBYPUBLICATIONOFANIDENTICALTEXTORBYENDORSEMENT,ATTHELATESTBYNOVEMBER2012,ANDCONFLICTINGNATIONALSTANDARDSSHALLBEWITHDRAWNATTHELATESTBYNOVEMBER2012ATTENTIONISDRAWNTOTHEPOSSIBILITYTHATSOMEOFTHEELEMENTSOFTHISDOCUMENTMAYBETHESUBJECTOFPATENTRIGHTSCENAND/ORCENELECSHALLNOTBEHELDRESPONSIBLEFORIDENTIFYINGANYORALLSUCHPATENTRIGHTSTHISDOCUMENTSUPERSEDESENISO99061999ACCORDINGTOTHECEN/CENELECINTERNALREGULATIONS,THENATIONALSTANDARDSORGANIZATIONSOFTHEFOLLOWINGCOUNTRIESAREBOUNDTOIMPLEMENTTHISEUROPEANSTANDARDAUSTRIA,BELGIUM,BULGARIA,CROATIA,CYPRUS,CZECHREPUBLIC,DENMARK,ESTONIA,FINLAND,FRANCE,GERMANY,GREECE,HUNGARY,ICELAND,IRELAND,ITALY,LATVIA,LITHUANIA,LUXEMBOURG,MALTA,NETHERLANDS,NORWAY,POLAND,PORTUGAL,ROMANIA,SLOVAKIA,SLOVENIA,SPAIN,SWEDEN,SWITZERLAND,TURKEYANDTHEUNITEDKINGDOMENDORSEMENTNOTICETHETEXTOFISO99062012HASBEENAPPROVEDBYCENASAENISO99062012WITHOUTANYMODIFICATIONCONTENTSBSENISO99062012ISO99062012EPAGEFOREWORDIVINTRODUCTIONV1SCOPE12NORMATIVEREFERENCES13TERMS,DEFINITIONS,SYMBOLSANDSUBSCRIPTS131TERMSANDDEFINITIONS132TERMSRELATINGTOQUANTITIES333SYMBOLSANDSUBSCRIPTS94PUMPMEASUREMENTSANDACCEPTANCECRITERIA1041GENERAL1042GUARANTEES1143MEASUREMENTUNCERTAINTY1144PERFORMANCETESTACCEPTANCEGRADESANDTOLERANCES1545DEFAULTTESTACCEPTANCEGRADESFORPUMPAPPLICATION215TESTPROCEDURES2251GENERAL2252DATEOFTESTING2253TESTPROGRAMME2254TESTINGEQUIPMENT2255RECORDSANDREPORT2256TESTARRANGEMENTS2357TESTCONDITIONS2358NPSHTESTS236ANALYSIS2661TRANSLATIONOFTHETESTRESULTSTOTHEGUARANTEECONDITIONS2662OBTAININGSPECIFIEDCHARACTERISTICS27ANNEXANORMATIVETESTARRANGEMENTS28ANNEXBINFORMATIVENPSHTESTARRANGEMENTS37ANNEXCINFORMATIVECALIBRATIONINTERVALS40ANNEXDINFORMATIVEMEASUREMENTEQUIPMENT41ANNEXEINFORMATIVETESTSPERFORMEDONTHEENTIREEQUIPMENTSETSTRINGTEST46ANNEXFINFORMATIVEREPORTINGOFTESTRESULTS48ANNEXGINFORMATIVESPECIALTESTMETHODS52ANNEXHINFORMATIVEWITNESSEDPUMPTEST53ANNEXIINFORMATIVECONVERSIONTOSIUNITS54ANNEXJINFORMATIVEMEASUREMENTUNCERTAINTYFORNPSHTEST56BIBLIOGRAPHY57ISO2012ALLRIGHTSRESERVEDIIIBSENISO99062012ISO99062012EFOREWORDISOTHEINTERNATIONALORGANIZATIONFORSTANDARDIZATIONISAWORLDWIDEFEDERATIONOFNATIONALSTANDARDSBODIESISOMEMBERBODIESTHEWORKOFPREPARINGINTERNATIONALSTANDARDSISNORMALLYCARRIEDOUTTHROUGHISOTECHNICALCOMMITTEESEACHMEMBERBODYINTERESTEDINASUBJECTFORWHICHATECHNICALCOMMITTEEHASBEENESTABLISHEDHASTHERIGHTTOBEREPRESENTEDONTHATCOMMITTEEINTERNATIONALORGANIZATIONS,GOVERNMENTALANDNONGOVERNMENTAL,INLIAISONWITHISO,ALSOTAKEPARTINTHEWORKISOCOLLABORATESCLOSELYWITHTHEINTERNATIONALELECTROTECHNICALCOMMISSIONIECONALLMATTERSOFELECTROTECHNICALSTANDARDIZATIONINTERNATIONALSTANDARDSAREDRAFTEDINACCORDANCEWITHTHERULESGIVENINTHEISO/IECDIRECTIVES,PART2THEMAINTASKOFTECHNICALCOMMITTEESISTOPREPAREINTERNATIONALSTANDARDSDRAFTINTERNATIONALSTANDARDSADOPTEDBYTHETECHNICALCOMMITTEESARECIRCULATEDTOTHEMEMBERBODIESFORVOTINGPUBLICATIONASANINTERNATIONALSTANDARDREQUIRESAPPROVALBYATLEAST75OFTHEMEMBERBODIESCASTINGAVOTEATTENTIONISDRAWNTOTHEPOSSIBILITYTHATSOMEOFTHEELEMENTSOFTHISDOCUMENTMAYBETHESUBJECTOFPATENTRIGHTSISOSHALLNOTBEHELDRESPONSIBLEFORIDENTIFYINGANYORALLSUCHPATENTRIGHTSISO9906WASPREPAREDBYTECHNICALCOMMITTEEISO/TC115,PUMPS,SUBCOMMITTEESC2,METHODSOFMEASUREMENTANDTESTINGTHISSECONDEDITIONCANCELSANDREPLACESTHEFIRSTEDITIONISO99061999,WHICHHASBEENTECHNICALLYREVISEDIVISO2012ALLRIGHTSRESERVEDBSENISO99062012ISO99062012EINTRODUCTIONTHETESTSINTHISINTERNATIONALSTANDARDAREINTENDEDTOASCERTAINTHEPERFORMANCEOFTHEPUMPANDTOCOMPARETHISWITHTHEMANUFACTURERSGUARANTEETHENOMINATEDGUARANTEEFORANYQUANTITYISDEEMEDTOHAVEBEENMETIF,WHERETESTEDACCORDINGTOTHISINTERNATIONALSTANDARD,THEMEASUREDPERFORMANCEFALLSWITHINTHETOLERANCESPECIFIEDFORTHEPARTICULARQUANTITYSEE44ISO2012ALLRIGHTSRESERVEDVBSENISO99062012BSENISO99062012INTERNATIONALSTANDARDISO99062012EROTODYNAMICPUMPSHYDRAULICPERFORMANCEACCEPTANCETESTSGRADES1,2AND31SCOPETHISINTERNATIONALSTANDARDSPECIFIESHYDRAULICPERFORMANCETESTSFORCUSTOMERSACCEPTANCEOFROTODYNAMICPUMPSCENTRIFUGAL,MIXEDFLOWANDAXIALPUMPS,HEREINAFTER“PUMPS”THISINTERNATIONALSTANDARDISINTENDEDTOBEUSEDFORPUMPACCEPTANCETESTINGATPUMPTESTFACILITIES,SUCHASMANUFACTURERSPUMPTESTFACILITIESORLABORATORIESITCANBEAPPLIEDTOPUMPSOFANYSIZEANDTOANYPUMPEDLIQUIDSWHICHBEHAVEASCLEAN,COLDWATERTHISINTERNATIONALSTANDARDSPECIFIESTHREELEVELSOFACCEPTANCEGRADES1B,1EAND1UWITHTIGHTERTOLERANCEGRADES2BAND2UWITHBROADERTOLERANCEGRADE3BWITHEVENBROADERTOLERANCETHISINTERNATIONALSTANDARDAPPLIESEITHERTOAPUMPITSELFWITHOUTANYFITTINGSORTOACOMBINATIONOFAPUMPASSOCIATEDWITHALLORPARTOFITSUPSTREAMAND/ORDOWNSTREAMFITTINGS2NORMATIVEREFERENCESTHEFOLLOWINGREFERENCEDDOCUMENTSAREINDISPENSABLEFORTHEAPPLICATIONOFTHISDOCUMENTFORDATEDREFERENCES,ONLYTHEEDITIONCITEDAPPLIESFORUNDATEDREFERENCES,THELATESTEDITIONOFTHEREFERENCEDDOCUMENTINCLUDINGANYAMENDMENTSAPPLIESISO177691,LIQUIDPUMPSANDINSTALLATIONGENERALTERMS,DEFINITIONS,QUANTITIES,LETTERSYMBOLSANDUNITSPART1LIQUIDPUMPSISO177692,LIQUIDPUMPSANDINSTALLATIONGENERALTERMS,DEFINITIONS,QUANTITIES,LETTERSYMBOLSANDUNITSPART2PUMPINGSYSTEM3TERMS,DEFINITIONS,SYMBOLSANDSUBSCRIPTS31TERMSANDDEFINITIONSFORTHEPURPOSESOFTHISDOCUMENT,THETERMS,DEFINITIONS,QUANTITIESANDSYMBOLSGIVENINISO177691AND177692ANDTHEFOLLOWINGAPPLYNOTE1TABLE1GIVESANALPHABETICALLISTOFTHESYMBOLSUSEDANDTABLE2GIVESALISTOFSUBSCRIPTSSEE33NOTE2ALLFORMULAEAREGIVENINCOHERENTSIUNITSFORCONVERSIONOFOTHERUNITSTOSIUNITS,SEEANNEXI311GENERALTERMSNOTEALLOFTHETYPESOFTESTIN311APPLYTOGUARANTEEPOINTTOFULFILTHECUSTOMERSSPECIFICATIONS3111GUARANTEEPOINTFLOW/HEADQ/HPOINT,WHICHATESTEDPUMPSHALLMEET,WITHINTHETOLERANCESOFTHEAGREEDACCEPTANCECLASSISO2012ALLRIGHTSRESERVED1BSENISO99062012ISO99062012E3112FACTORYPERFORMANCETESTPUMPTESTPERFORMEDTOVERIFYTHEINITIALPERFORMANCEOFNEWPUMPSASWELLASCHECKINGFORREPEATABILITYOFPRODUCTIONUNITS,ACCURACYOFIMPELLERTRIMCALCULATIONS,PERFORMANCEWITHSPECIALMATERIALS,ETCNOTEATYPICALPERFORMANCETESTCONSISTSOFTHEMEASUREMENTOFFLOW,HEADANDPOWERINPUTTOTHEPUMPORPUMPTESTMOTORADDITIONALMEASUREMENTS,SUCHASNPSH,MAYBEINCLUDEDASAGREEDUPONAFACTORYTESTISUNDERSTOODTOMEANTESTINGATADEDICATEDTESTFACILITY,OFTENATAPUMPMANUFACTURERSPLANTORATANINDEPENDENTPUMPTESTFACILITY3113NONWITNESSEDPUMPTEST31131FACTORYTESTTESTPERFORMEDWITHOUTTHEPRESENCEOFAPURCHASERSREPRESENTATIVE,INWHICHTHEPUMPMANUFACTURERISRESPONSIBLEFORTHEDATACOLLECTIONANDJUDGEMENTOFPUMPACCEPTANCENOTETHEADVANTAGEOFTHISTESTISCOSTSAVINGSANDACCELERATEDPUMPDELIVERYTOTHEPUMPUSERINMANYCASES,IFTHEPURCHASERISFAMILIARWITHTHEPERFORMANCEOFTHEPUMPEGIDENTICALPUMPMODELORDER,AFACTORYNONWITNESSEDTESTMAYBEACCEPTABLE31132SIGNEDFACTORYTESTTESTPERFORMEDWITHOUTTHEPRESENCEOFAPURCHASERSREPRESENTATIVE,INWHICHTHEPUMPMANUFACTURERISRESPONSIBLEFORCOMPLIANCEWITHTHEPARAMETERSOFTHEAGREEDACCEPTANCECLASSNOTETHEPUMPMANUFACTURERCONDUCTSTHETEST,PASSESJUDGEMENTOFPUMPACCEPTANCEANDPRODUCESASIGNEDPUMPTESTDOCUMENTTHEADVANTAGEOFTHISTESTISTHESAMEASSEENONTHENONWITNESSEDTESTCOMPAREDTOAWITNESSEDTEST,THISTESTISSUBSTANTIALLYLESSEXPENSIVEANDOFTENLEADSTOACCELERATEDPUMPDELIVERYTOTHEENDUSER3114WITNESSEDPUMPTESTNOTETHEWITNESSINGOFAPUMPTESTBYAREPRESENTATIVEOFTHEPUMPPURCHASERCANSERVEMANYUSEFULFUNCTIONSTHEREAREVARIOUSWAYSOFWITNESSINGATEST31141WITNESSINGBYTHEPURCHASERSREPRESENTATIVETESTINGPHYSICALLYATTENDEDBYAREPRESENTATIVEOFTHEPURCHASER,WHOSIGNSOFFONTHERAWTESTDATATOCERTIFYTHATTHETESTISPERFORMEDSATISFACTORILYNOTEITISPOSSIBLEFORFINALACCEPTANCEOFTHEPUMPPERFORMANCETOBEDETERMINEDBYTHEWITNESSTHEBENEFITOFWITNESSTESTINGDEPENDSLARGELYONTHEEFFECTIVENESSANDEXPERTISEOFTHEWITNESSAWITNESSCANNOTONLYENSURETHETESTISCONDUCTEDPROPERLY,BUTALSOOBSERVESOPERATIONOFTHEPUMPDURINGTESTINGPRIORTOPUMPSHIPMENTTOTHEJOBSITEADISADVANTAGEOFWITNESSTESTINGCANBEEXTENDEDDELIVERYTIMESANDEXCESSIVECOSTWITHJUSTINTIMEMANUFACTURINGMETHODS,THESCHEDULINGOFWITNESSTESTINGREQUIRESFLEXIBILITYONTHEPARTOFTHEWITNESSANDCANLEADTOADDITIONALCOSTSIFTHESCHEDULEOFTHEWITNESSCAUSESDELAYSINMANUFACTURING31142REMOTEWITNESSINGBYTHEPURCHASERSREPRESENTATIVEPUMPPERFORMANCETESTINGWITNESSEDFROMADISTANCEBYTHEPURCHASERORHIS/HERREPRESENTATIVENOTEWITHAREMOTECAMERASYSTEM,THEPURCHASERCANMONITORTHEENTIRETESTINGREMOTELYINREALTIMETHERAWDATA,ASRECORDEDBYTHEDATAACQUISITIONSYSTEM,CANBEVIEWEDANDANALYSEDDURINGTHETEST,ANDTHERESULTSCANBEDISCUSSEDANDSUBMITTEDFORAPPROVALTHEADVANTAGESOFTHISTYPEOFTESTINGARESAVINGSINTRAVELCOSTSANDACCELERATEDPUMPDELIVERY2ISO2012ALLRIGHTSRESERVEDBSENISO99062012ISO99062012E32TERMSRELATINGTOQUANTITIES321ANGULARVELOCITYNUMBEROFRADIANSOFSHAFTROTATIONNOTE1ITISGIVENBY2N1NOTE2ITISEXPRESSEDINTIME,EGS1,WHERENISGIVENIN60MIN1322SPEEDOFROTATIONNUMBEROFROTATIONSPERSECOND323MASSFLOWRATERATEOFFLOWDISCHARGEDINTOTHEPIPEFROMTHEOUTLETCONNECTIONOFTHEPUMPNOTE1THEMASSFLOWRATEISGIVENINKILOGRAMSPERSECONDNOTE2THEFOLLOWINGLOSSESORLIMITINGEFFECTSAREINHERENTTOTHEPUMPADISCHARGENECESSARYFORHYDRAULICBALANCINGOFAXIALTHRUSTBCOOLINGOFTHEPUMPBEARINGSNOTE3LEAKAGEFROMTHEFITTINGS,INTERNALLEAKAGE,ETC,ARENOTTOBERECKONEDINTHERATEOFFLOWONTHECONTRARY,ALLDERIVEDFLOWSFOROTHERPURPOSES,SUCHASACOOLINGOFTHEMOTORBEARINGS,ANDBCOOLINGOFAGEARBOXBEARINGS,OILCOOLERARETOBERECKONEDINTHERATEOFFLOWNOTE4WHETHERANDHOWTHESEFLOWSSHOULDBETAKENINTOACCOUNTDEPENDSONTHELOCATIONOFTHEIRDERIVATIONANDOFTHESECTIONOFFLOWMEASUREMENTRESPECTIVELY324VOLUMERATEOFFLOWRATEOFFLOWATTHEOUTLETOFTHEPUMP,GIVENBYQQ2NOTEINTHISINTERNATIONALSTANDARD,THISSYMBOLMAYALSODESIGNATETHEVOLUMERATEOFFLOWINANYGIVENSECTIONITISTHEQUOTIENTOFTHEMASSRATEOFFLOWINTHISSECTIONBYTHEDENSITYTHESECTIONMAYBEDESIGNATEDBYSUBSCRIPTS325MEANVELOCITYMEANVALUEOFTHEAXIALSPEEDOFFLOW,GIVENBYUQA3NOTEATTENTIONISDRAWNTOTHEFACTTHATINTHISCASE,QMAYVARYFORDIFFERENTREASONSACROSSTHECIRCUIT326LOCALVELOCITYSPEEDOFFLOWATANYGIVENPOINTISO2012ALLRIGHTSRESERVED3BSENISO99062012ISO99062012E327HEADENERGYOFMASSOFLIQUID,DIVIDEDBYACCELERATIONDUETOGRAVITY,G,GIVENBYHY4GSEE3216328REFERENCEPLANEANYHORIZONTALPLANEUSEDASADATUMFORHEIGHTMEASUREMENTNOTEFORPRACTICALREASONS,ITISPREFERABLENOTTOSPECIFYANIMAGINARYREFERENCEPLANE329HEIGHTABOVEREFERENCEPLANEHEIGHTOFTHECONSIDEREDPOINTABOVETHEREFERENCEPLANESEEFIGUREA1NOTEITSVALUEISPOSITIVE,IFTHECONSIDEREDPOINTISABOVETHEREFERENCEPLANENEGATIVE,IFTHECONSIDEREDPOINTISBELOWTHEREFERENCEPLANE3210GAUGEPRESSUREPRESSURERELATIVETOATMOSPHERICPRESSURENOTE1ITSVALUEISPOSITIVE,IFTHISPRESSUREISGREATERTHANTHEATMOSPHERICPRESSURENEGATIVE,IFTHISPRESSUREISLESSTHANTHEATMOSPHERICPRESSURENOTE2ALLPRESSURESINTHISINTERNATIONALSTANDARDAREGAUGEPRESSURESREADFROMAMANOMETERORSIMILARPRESSURESENSINGINSTRUMENT,EXCEPTATMOSPHERICPRESSUREANDTHEVAPOURPRESSUREOFTHELIQUID,WHICHAREEXPRESSEDASABSOLUTEPRESSURES3211VELOCITYHEADKINETICENERGYOFTHELIQUIDINMOVEMENT,DIVIDEDBYG,GIVENBYU252G3212TOTALHEADOVERALLENERGYINANYSECTIONNOTE1THETOTALHEADISGIVENBYHXZXPXUX26G2GWHEREZISTHEHEIGHTOFTHECENTREOFTHECROSSSECTIONABOVETHEREFERENCEPLANEPISTHEGAUGEPRESSURERELATEDTOTHECENTREOFTHECROSSSECTIONNOTE2THEABSOLUTETOTALHEADINANYSECTIONISGIVENBY4ISO2012ALLRIGHTSRESERVEDBSENISO99062012ISO99062012EHXABSZXPXPAMBUX2GG2G3213INLETTOTALHEADOVERALLENERGYATTHEINLETSECTIONOFTHEPUMPNOTEINLETTOTALHEADISGIVENBYPU2H1Z111G2G3214OUTLETTOTALHEADOVERALLENERGYATTHEOUTLETSECTIONOFTHEPUMPNOTEOUTLETTOTALHEADISGIVENBYH2Z2P2U22G2G3215PUMPTOTALHEADALGEBRAICDIFFERENCEBETWEENTHEOUTLETTOTALHEAD,H2,ANDTHEINLETTOTALHEAD,H1789NOTE1IFCOMPRESSIBILITYISNEGLIGIBLE,HH2H1IFTHECOMPRESSIBILITYOFTHEPUMPEDLIQUIDISSIGNIFICANT,THEDENSITY,SHOULDBEREPLACEDBYTHEMEANVALUEM122ANDTHEPUMPTOTALHEADSHOULDBECALCULATEDBYFORMULA12P2PU2U2HZ2Z1121MG2GNOTE2THECORRECTMATHEMATICALSYMBOLISH123216SPECIFICENERGYENERGYOFLIQUID,GIVENBYYGH1011123217LOSSOFHEADATINLETDIFFERENCEBETWEENTHETOTALHEADOFTHELIQUIDATTHEMEASURINGPOINTANDTHETOTALHEADOFTHELIQUIDINTHEINLETSECTIONOFTHEPUMP3218LOSSOFHEADATOUTLETDIFFERENCEBETWEENTHETOTALHEADOFTHELIQUIDINTHEOUTLETSECTIONOFTHEPUMPANDTHETOTALHEADOFTHELIQUIDATTHEMEASURINGPOINT3219PIPEFRICTIONLOSSCOEFFICIENTCOEFFICIENTFORTHEHEADLOSSBYFRICTIONINTHEPIPEISO2012ALLRIGHTSRESERVED5BSENISO99062012ISO99062012E3220NETPOSITIVESUCTIONHEADNPSHABSOLUTEINLETTOTALHEADABOVETHEHEADEQUIVALENTTOTHEVAPOURPRESSURERELATIVETOTHENPSHDATUMPLANENOTE1NPSHISGIVENBYNPSHH1ZDPAMBPV131GNOTE2THISNPSHRELATESTOTHENPSHDATUMPLANE,WHEREASINLETTOTALHEADRELATESTOTHEREFERENCEPLANENOTE3ADEROGATIONHASBEENGIVENTOALLOWTHEUSEOFTHEABBREVIATEDTERMNPSHUPRIGHTANDNOTBOLDASASYMBOLINMATHEMATICALFORMULAEASACONSEQUENCEOFITSWELLESTABLISHED,HISTORICALUSEINTHISMANNER32201NPSHDATUMPLANEHORIZONTALPLANETHROUGHTHECENTREOFTHECIRCLEDESCRIBEDBYTHEEXTERNALPOINTSOFTHEENTRANCEEDGESOFTHEIMPELLERBLADES32202NPSHDATUMPLANEPLANETHROUGHTHEHIGHERCENTRESEEFIGURE1NOTEITISTHERESPONSIBILITYOFTHEMANUFACTURERTOINDICATETHEPOSITIONOFTHISPLANEWITHRESPECTTOPRECISEREFERENCEPOINTSONTHEPUMPKEY1NPSHDATUMPLANEFIGURE1NPSHDATUMPLANE3221AVAILABLENPSHNPSHANPSHAVAILABLEASDETERMINEDBYTHECONDITIONSOFTHEINSTALLATIONFORASPECIFIEDRATEOFFLOWNOTEADEROGATIONHASBEENGIVENTOALLOWTHEUSEOFTHEABBREVIATEDTERMNPSHAUPRIGHTANDNOTBOLDASASYMBOLINMATHEMATICALFORMULAEASACONSEQUENCEOFITSWELLESTABLISHED,HISTORICALUSEINTHISMANNER3222REQUIREDNPSHNPSHRMINIMUMNPSHGIVENBYTHEMANUFACTURERFORAPUMPACHIEVINGASPECIFIEDPERFORMANCEATTHESPECIFIEDRATEOFFLOW,SPEEDANDPUMPEDLIQUIDOCCURRENCEOFVISIBLECAVITATION,INCREASEOFNOISEANDVIBRATIONDUETOCAVITATION,BEGINNINGOFHEADOREFFICIENCYDROP,HEADOREFFICIENCYDROPOFAGIVENAMOUNT,LIMITATIONOFCAVITATIONEROSIONNOTEADEROGATIONHASBEENGIVENTOALLOWTHEUSEOFTHEABBREVIATEDTERMNPSHRUPRIGHTANDNOTBOLDASASYMBOLINMATHEMATICALFORMULAEASACONSEQUENCEOFITSWELLESTABLISHED,HISTORICALUSEINTHISMANNER6ISO2012ALLRIGHTSRESERVEDBSENISO99062012ISO99062012E3223NPSH3NPSHREQUIREDFORADROPOF3OFTHETOTALHEADOFTHEFIRSTSTAGEOFTHEPUMPASSTANDARDBASISFORUSEINPERFORMANCECURVESNOTEADEROGATIONHASBEENGIVENTOALLOWTHEUSEOFTHEABBREVIATEDTERMNPSHUPRIGHTANDNOTBOLDASASYMBOLINMATHEMATICALFORMULAEASACONSEQUENCEOFITSWELLESTABLISHED,HISTORICALUSEINTHISMANNER3224TYPENUMBERDIMENSIONLESSQUANTITYCALCULATEDATTHEPOINTOFBESTEFFICIENCYNOTE1ITISGIVENBYK2NQ1/2Q1/214GH3/4Y3/4WHEREQISTHEVOLUMERATEOFFLOWPEREYEHISTHEHEADOFTHEFIRSTSTAGENISGIVENINS1NOTE2THETYPENUMBERISTOBETAKENATMAXIMUMDIAMETEROFTHEFIRSTSTAGEIMPELLER3225PUMPPOWERINPUTP2POWERTRANSMITTEDTOTHEPUMPBYITSDRIVER3226PUMPPOWEROUTPUTHYDRAULICPOWERATTHEPUMPDISCHARGENOTEPUMPPOWEROUTPUTISGIVENBYPHQGHQY153227DRIVERPOWERINPUTPGRPOWERABSORBEDBYTHEPUMPDRIVER3228MAXIMUMSHAFTPOWERP2,MAXMAXIMUMPUMPSHAFTPOWER,ASSETBYTHEMANUFACTURER,WHICHISADEQUATETODRIVETHEPUMPOVERTHESPECIFIEDOPERATINGCONDITIONS3229PUMPEFFICIENCYPUMPPOWEROUTPUTDIVIDEDBYTHEPUMPPOWERINPUTNOTEPUMPEFFICIENCYISGIVENBYPH16P2ISO2012ALLRIGHTSRESERVED7BSENISO99062012ISO99062012E3230OVERALLEFFICIENCYPUMPPOWEROUTPUTDIVIDEDBYTHEDRIVERPOWERINPUTNOTEOVERALLEFFICIENCYISGIVENBYGRPH17PGR8ISO2012ALLRIGHTSRESERVEDBSENISO99062012ISO99062012E33SYMBOLSANDSUBSCRIPTSTABLE1ALPHABETICALLISTOFBASICLETTERSUSEDASSYMBOLSSYMBOLQUANTITYUNITAAREAM2DDIAMETERMEOVERALLUNCERTAINTY,RELATIVEVALUEFFREQUENCYS1,HZGACCELERATIONDUETOGRAVITYAM/S2HPUMPTOTALHEADMHJLOSSESINTERMSOFHEADOFLIQUIDMKEQUIVALENTUNIFORMROUGHNESSMKTYPENUMBERPURENUMBERLLENGTHMMTORQUENMNSPEEDOFROTATIONS1,MIN1NPSHNETPOSITIVESUCTIONHEADMPPRESSUREPAPPOWERWQMASSFLOWRATEBKG/SQVOLUMERATEOFFLOWCM3/SREREYNOLDSNUMBERPURENUMBERTOLERANCEFACTOR,RELATIVEVALUETSTUDENTSDISTRIBUTIONPURENUMBERUMEANVELOCITYM/SVLOCALVELOCITYM/SVVOLUMEM3YSPECIFICENERGYJ/KGZHEIGHTABOVEREFERENCEPLANEMZDDIFFERENCEBETWEENNPSHDATUMPLANEANDREFERENCEPLANESEE3220MEFFICIENCYPURENUMBERTEMPERATURECPIPEFRICTIONLOSSCOEFFICIENTPURENUMBERKINEMATICVISCOSITYM2/SDENSITYKG/M3ANGULARVELOCITYRAD/SAINPRINCIPLE,THELOCALVALUEOFGSHOULDBEUSEDNEVERTHELESS,FORGRADES2
温馨提示
- 1. 本站所有资源如无特殊说明,都需要本地电脑安装OFFICE2007和PDF阅读器。图纸软件为CAD,CAXA,PROE,UG,SolidWorks等.压缩文件请下载最新的WinRAR软件解压。
- 2. 本站的文档不包含任何第三方提供的附件图纸等,如果需要附件,请联系上传者。文件的所有权益归上传用户所有。
- 3. 本站RAR压缩包中若带图纸,网页内容里面会有图纸预览,若没有图纸预览就没有图纸。
- 4. 未经权益所有人同意不得将文件中的内容挪作商业或盈利用途。
- 5. 人人文库网仅提供信息存储空间,仅对用户上传内容的表现方式做保护处理,对用户上传分享的文档内容本身不做任何修改或编辑,并不能对任何下载内容负责。
- 6. 下载文件中如有侵权或不适当内容,请与我们联系,我们立即纠正。
- 7. 本站不保证下载资源的准确性、安全性和完整性, 同时也不承担用户因使用这些下载资源对自己和他人造成任何形式的伤害或损失。
最新文档
- 计算机软件应用课件考核试卷
- 橡胶在建筑领域的使用考核试卷
- 锌锰电池失效分析与预防措施考核试卷
- 零售门店顾客引流策略考核试卷
- 传感器在智能交通信号系统中的应用考核试卷
- 毕业设计动员大会
- 呼吸机结构与原理
- HDAC6-IN-53-生命科学试剂-MCE
- 暴雨橙色预警防御指南(27P)
- 2025年下半年钢铁行业成本压力缓解行业格局改善
- 2025年 内蒙古能源集团所属单位招聘考试笔试试题(含答案)
- 期末试卷(试题)(含答案)-2024-2025学年一年级下册数学北师大版
- 2025年江西省高考物理真题
- 2024年地理中考模拟考试地理(贵州贵阳卷)(A4考试版)
- 上海浦东新区公办学校储备教师教辅招聘笔试真题2022
- DB37T 4027-2020 食用农产品可追溯供应商通用规范 果蔬
- 企业资产损失所得税税前扣除鉴证业务操作的指南
- 高等数学(下册)资料期末复习试题与答案
- 监理人员廉洁自律制度管理办法
- 四冲程内燃机 机械原理课程设计说明书
- BS EN 10222-5-2000用于压力目的的钢锻件—第5部分:马口铁钢奥氏体钢和奥氏体-铁素体不锈钢
评论
0/150
提交评论