




已阅读5页,还剩15页未读, 继续免费阅读
版权说明:本文档由用户提供并上传,收益归属内容提供方,若内容存在侵权,请进行举报或认领
文档简介
G49G50G3G38G50G51G60G44G49G42G3G58G44G55G43G50G56G55G3G37G54G44G3G51G40G53G48G44G54G54G44G50G49G3G40G59G38G40G51G55G3G36G54G3G51G40G53G48G44G55G55G40G39G3G37G60G3G38G50G51G60G53G44G42G43G55G3G47G36G58GASCYLINDERSTHEEUROPEANSTANDARDEN1447022006HASTHESTATUSOFABRITISHSTANDARDICS13220407104010FIRESAFETYSTORAGECABINETSPART2SAFETYCABINETSFORPRESSURISEDBRITISHSTANDARDBSEN1447022006BSEN1447022006THISBRITISHSTANDARDWASPUBLISHEDUNDERTHEAUTHORITYOFTHESTANDARDSPOLICYANDSTRATEGYCOMMITTEEON31JANUARY2007BSI2007ISBN9780580499845AMENDMENTSISSUEDSINCEPUBLICATIONAMDNODATECOMMENTSCONTRACTUSERSARERESPONSIBLEFORITSCORRECTAPPLICATIONCOMPLIANCEWITHABRITISHSTANDARDCANNOTCONFERIMMUNITYFROMLEGALOBLIGATIONSNATIONALFOREWORDTHISBRITISHSTANDARDWASPUBLISHEDBYBSIITISTHEUKIMPLEMENTATIONOFEN1447022006THEUKPARTICIPATIONINITSPREPARATIONWASENTRUSTEDTOTECHNICALCOMMITTEELBI/18,LABORATORYFURNITUREANDFITTINGSALISTOFORGANIZATIONSREPRESENTEDONLBI/18CANBEOBTAINEDONREQUESTTOITSSECRETARYTHISPUBLICATIONDOESNOTPURPORTTOINCLUDEALLTHENECESSARYPROVISIONSOFAEUROPEANSTANDARDNORMEEUROPENNEEUROPISCHENORMEN144702AUGUST2006ICS13220407104010ENGLISHVERSIONFIRESAFETYSTORAGECABINETSPART2SAFETYCABINETSFORPRESSURISEDGASCYLINDERSARMOIRESDESTOCKAGEDESCURITINCENDIEPARTIE2ARMOIRESDESTOCKAGEDESCURITPOURBOUTEILLESDEGAZCOMPRIMFEUERWIDERSTANDSFHIGELAGERSCHRNKETEIL2SICHERHEITSSCHRNKEFRDRUCKGASFLASCHENTHISEUROPEANSTANDARDWASAPPROVEDBYCENON21JULY2006CENMEMBERSAREBOUNDTOCOMPLYWITHTHECEN/CENELECINTERNALREGULATIONSWHICHSTIPULATETHECONDITIONSFORGIVINGTHISEUROPEANSTANDARDTHESTATUSOFANATIONALSTANDARDWITHOUTANYALTERATIONUPTODATELISTSANDBIBLIOGRAPHICALREFERENCESCONCERNINGSUCHNATIONALSTANDARDSMAYBEOBTAINEDONAPPLICATIONTOTHECENTRALSECRETARIATORTOANYCENMEMBERTHISEUROPEANSTANDARDEXISTSINTHREEOFFICIALVERSIONSENGLISH,FRENCH,GERMANAVERSIONINANYOTHERLANGUAGEMADEBYTRANSLATIONUNDERTHERESPONSIBILITYOFACENMEMBERINTOITSOWNLANGUAGEANDNOTIFIEDTOTHECENTRALSECRETARIATHASTHESAMESTATUSASTHEOFFICIALVERSIONSCENMEMBERSARETHENATIONALSTANDARDSBODIESOFAUSTRIA,BELGIUM,CYPRUS,CZECHREPUBLIC,DENMARK,ESTONIA,FINLAND,FRANCE,GERMANY,GREECE,HUNGARY,ICELAND,IRELAND,ITALY,LATVIA,LITHUANIA,LUXEMBOURG,MALTA,NETHERLANDS,NORWAY,POLAND,PORTUGAL,ROMANIA,SLOVAKIA,SLOVENIA,SPAIN,SWEDEN,SWITZERLANDANDUNITEDKINGDOMEUROPEANCOMMITTEEFORSTANDARDIZATIONCOMITEUROPENDENORMALISATIONEUROPISCHESKOMITEEFRNORMUNGMANAGEMENTCENTRERUEDESTASSART,36B1050BRUSSELS2006CENALLRIGHTSOFEXPLOITATIONINANYFORMANDBYANYMEANSRESERVEDWORLDWIDEFORCENNATIONALMEMBERSREFNOEN1447022006EEN1447022006E2CONTENTSPAGEFOREWORD3INTRODUCTION41SCOPE52NORMATIVEREFERENCES53TERMSANDDEFINITIONS54CLASSIFICATION65CONSTRUCTION651FIREPROTECTION652VENTILATION653GASCYLINDERRESTRAINING754INSERTIONANDREMOVALOFPRESSURISEDGASCYLINDERS755INSTALLATIONOFGASPIPELINESFORGASCYLINDERSINUSE756INSTALLATIONOFELECTRICCABLESWHEREAPPROPRIATE76FIRERESISTANCE77INFORMATIONTOBESUPPLIED78MANUFACTURERSMARKINGANDLABELLING8ANNEXANORMATIVETYPEGTESTINGTODETERMINEFIRERESISTANCE9A1PRINCIPLE9A2TESTINGAPPARATUSANDTESTMETHODS9A21FURNACE9A22MEASURINGEQUIPMENT9A23WEIGHINGSYSTEM9A3TESTMODELS9A31QUANTITYANDDESCRIPTIONOFTESTMODELS9A32PRELIMINARYEXAMINATIONOFTHETESTMODEL10A4PREPARATIONOFFIRETEST10A41SAFETYCABINET10A42INSTALLATIONOFTESTMODEL10A43TEMPERATUREMEASURINGDEVICEPLACEMENT11A44TEMPERATUREMEASURINGDEVICEPLACEMENTINTHEFIREROOM11A5FIRETESTINGPROCEDURE11A6TESTREPORT11ANNEXBINFORMATIVEAPPROVALREGARDINGCONSTRUCTIONALTERATIONS15BIBLIOGRAPHY16WWWBZFXWCOMEN1447022006E3FOREWORDTHISDOCUMENTEN1447022006HASBEENPREPAREDBYTECHNICALCOMMITTEECEN/TC332“LABORATORYEQUIPMENT”,THESECRETARIATOFWHICHISHELDBYDINTHISEUROPEANSTANDARDSHALLBEGIVENTHESTATUSOFANATIONALSTANDARD,EITHERBYPUBLICATIONOFANIDENTICALTEXTORBYENDORSEMENT,ATTHELATESTBYFEBRUARY2007,ANDCONFLICTINGNATIONALSTANDARDSSHALLBEWITHDRAWNATTHELATESTBYFEBRUARY2007EN14470,FIRESAFETYSTORAGECABINETS,CONSISTSOFTHEFOLLOWINGPARTSPART1SAFETYSTORAGECABINETSFORFLAMMABLELIQUIDSPART2SAFETYCABINETSFORPRESSURISEDGASCYLINDERSACCORDINGTOTHECEN/CENELECINTERNALREGULATIONS,THENATIONALSTANDARDSORGANIZATIONSOFTHEFOLLOWINGCOUNTRIESAREBOUNDTOIMPLEMENTTHISEUROPEANSTANDARDAUSTRIA,BELGIUM,CYPRUS,CZECHREPUBLIC,DENMARK,ESTONIA,FINLAND,FRANCE,GERMANY,GREECE,HUNGARY,ICELAND,IRELAND,ITALY,LATVIA,LITHUANIA,LUXEMBOURG,MALTA,NETHERLANDS,NORWAY,POLAND,PORTUGAL,ROMANIA,SLOVAKIA,SLOVENIA,SPAIN,SWEDEN,SWITZERLANDANDUNITEDKINGDOMWWWBZFXWCOMEN1447022006E4INTRODUCTIONTHISEUROPEANSTANDARDDESCRIBESTHEDESIGNANDTESTCRITERIAFORSAFETYCABINETSUSEDBYLABORATORIESTOSTOREPRESSURISEDGASCYLINDERSATNORMALROOMTEMPERATURETHECABINETISDESIGNEDANDCONSTRUCTEDTOENSURETHATINTHEEVENTOFFIRE,THECONTENTSOFTHECABINETDONOTCONTRIBUTEANYADDITIONALRISKSORSPREADTHEFIREFORATLEAST15MINUTESTHECABINETISALSODESIGNEDANDCONSTRUCTEDTOVENTILATEMINORGASLEAKAGEWITHINTHECABINETTESTINGTHECABINETUNDERFIRECONDITIONSISANORMATIVEPARTOFTHISSTANDARDANDTHEPROCEDURESANDINTERPRETATIONOFTHETESTSAREDESCRIBEDINDETAILTHEFIRERATINGALLOWSTIMEFORPERSONNELTOLEAVEANDFIREFIGHTERSTOENTERTHEAREABEFORETHEPRESSURISEDGASCYLINDERSBECOMEUNSTABLEWWWBZFXWCOMEN1447022006E51SCOPETHISEUROPEANSTANDARDISAPRODUCTSPECIFICATION,GIVINGPERFORMANCEREQUIREMENTSFORFIRESAFETYCABINETSUSEDFORSTORINGPRESSURISEDGASCYLINDERSITISAPPLICABLETOCABINETSWITHATOTALINTERNALVOLUMESUITABLETOSTOREPRESSURISEDGASCYLINDERSWITHATOTALVOLUMENOTEXCEEDING220L,INCLUDINGCYLINDERSOFPURGINGGASESNOTE1THISMEANSTHATUPTOFOURGASCYLINDERSOF50LORUPTOTHREEGASCYLINDERSOF70LCANBESTOREDINASINGLECABINETNOTE2ITISINTENDEDTHATTHEPRESSURISEDGASCYLINDERSCANBEINUSEWHILEINTHECABINETNOTE3ATTENTIONISDRAWNTONATIONALREGULATIONSWHICHCANAPPLYWITHREGARDTOTHESTORAGEANDUSEOFPRESSURISEDGASCYLINDERSNOTE4THESAFETYCABINETCANBEFREESTANDING,RESTRAINEDTOAWALLORMOUNTEDONWHEELSORCASTORSTHISSTANDARDISNOTAPPLICABLETOBRICKENCLOSURES,WALKINSTORAGEROOMSORCABINETSWHICHDONOTTAKETHEIRWEIGHTONTHEIRBASEREQUIREMENTSAREGIVENINRESPECTTOTHECONSTRUCTIONOFTHECABINETANDITSCAPACITYTORESISTFIRECONDITIONSONTHEOUTSIDEATYPETESTISINCLUDED,WHICHISBASEDONTHEALREADYEXISTINGFIRERESISTANCEHEATINGCURVETESTSGIVENINEN144701THETESTSDESCRIBEDINTHISEUROPEANSTANDARDARETYPETESTSFORTHESTORAGEOFFLAMMABLELIQUIDSEN144701ISAPPLICABLETHECRITERIAFORFAILUREAREDIFFERENTSEEANNEXA2NORMATIVEREFERENCESTHEFOLLOWINGREFERENCEDDOCUMENTSAREINDISPENSABLEFORTHEAPPLICATIONOFTHISEUROPEANSTANDARDFORDATEDREFERENCES,ONLYTHEEDITIONCITEDAPPLIESFORUNDATEDREFERENCES,THELATESTEDITIONOFTHEREFERENCEDDOCUMENTINCLUDINGANYAMENDMENTSAPPLIESEN136311999,FIRERESISTANCETESTSPART1GENERALREQUIREMENTSENISO139432000,FIRESAFETYVOCABULARYISO139432000ISO3864ALLPARTS,GRAPHICALSYMBOLSSAFETYCOLOURSANDSAFETYSIGNS3TERMSANDDEFINITIONSFORTHEPURPOSESOFTHISDOCUMENT,THETERMSANDDEFINITIONSGIVENINENISO139432000ANDTHEFOLLOWINGAPPLY31TYPESPECIMENOFADESIGNMANUFACTUREDWITHTHECHARACTERISTICSINTENDEDFORSERIALPRODUCTION32TYPETESTINGCONFORMITYTESTINGONTHEBASISOFONEORMORESPECIMENSOFPRODUCTREPRESENTATIVEOFTHEPRODUCTIONWWWBZFXWCOMEN1447022006E64CLASSIFICATIONAGASCYLINDERCABINETSHALLBECLASSIFIEDASONEOFTHETYPESLISTEDINTABLE1TABLE1FIRESAFETYCABINETFORPRESSURISEDGASCYLINDERTYPECLASSIFICATIONTYPETIMETAKENFORTATORISEBY50KMINTESTACCORDINGTOEN136311999VENTILATIONCONNECTIONFACILITYREQUIREDG1515YESYESG3030YESYESG6060YESYESG9090YESYESATISTHETEMPERATURETAKENONTHESURFACEOFTHEGASCYLINDERVALVESPANNERFLAT5CONSTRUCTION51FIREPROTECTIONTHECABINETSHALLBEDESIGNEDANDCONSTRUCTEDTOENSURETHAT,INTHEEVENTOFAFIRE,THECONTENTSOFTHECABINETDONOTCONTRIBUTEANYADDITIONALRISKSORSPREADTHEFIREFORATLEAST15MINUTES52VENTILATION521CABINETSSHALLBEEQUIPPEDWITHOPENINGSFORINLETANDEXHAUSTAIR,WHICHALLOWSFORCONNECTIONOFANEXHAUSTAIRSYSTEMTOTHECABINETINAVENTILATEDCABINETINWHICHVENTILATIONISTAKINGPLACE,WITHTHEDOORSCLOSED,LATCHEDANDLOCKED,THEFOLLOWINGEXTRACTIONRATESSHALLAPPLYWHENUSINGFLAMMABLEANDFIRESUPPORTINGGAS,ATLEAST10AIRCHANGESOFTHECABINETSVOLUMEPERHOURWHENUSINGTOXICGAS,ATLEAST120AIRCHANGESOFTHECABINETSVOLUMEPERHOURUNDERTHEABOVECONDITIONSTHEPRESSUREDROPSHALLNOTEXCEED150PATHEVENTILATIONSYSTEMSHALLMAINTAINALOWERPRESSUREINTHECABINETTHANINTHESURROUNDINGATMOSPHEREVENTILATIONSHALLTAKEPLACEONTHETOPANDBOTTOMOFTHECABINETDESIGNOFTHEAIRCIRCULATIONSYSTEMWITHINTHECABINETSHALLENSUREADEQUATEPURGINGFROMMINORLEAKAGETHISSHALLBETESTEDBYVISUALINSPECTIONANDBYMEASURINGTHEAIRFLOWANDPRESSUREDROPWHILETHECABINETISEMPTYNOTETHEINLETPRESSUREDROPANDTHENUMBEROFAIRCHANGESHAVEBEENCHOSENTOPROVIDEPURGINGEFFICIENCY522INTHEEVENTOFAFIRE,THEINLETANDEXHAUSTVENTSSHALLCLOSEAUTOMATICALLYTHEVENTSCLOSINGSYSTEMSHALLBETESTEDASPARTOFTHEFIRERESISTANCETESTINANNEXAWWWBZFXWCOMEN1447022006E753GASCYLINDERRESTRAININGWITHINTHECABINETASUITABLESYSTEMSHALLBEINSTALLEDTOPREVENTGASCYLINDERSFROMFALLINGOVERTHESYSTEMSHALLBESUITABLEFORTHEQUANTITYANDDIMENSIONSOFCYLINDERS,WHICHCANBEUSEDINACCORDANCEWITHTHEUSERSINSTRUCTIONMANUAL54INSERTIONANDREMOVALOFPRESSURISEDGASCYLINDERSTHECABINETSHALLBECONSTRUCTEDSOTHATCYLINDERSCANBEINSERTEDANDREMOVEDASSAFELYASPOSSIBLEWITHMINIMUMMANUALEFFORTFOREXAMPLE,WHENCABINETBASESAREABOVEFLOORLEVELARAMPAND/ORMECHANICALLIFTINGEQUIPMENTCANBEEMPLOYED,HOWEVER,THESESHALLNOTBEMADEOFALUMINIUM55INSTALLATIONOFGASPIPELINESFORGASCYLINDERSINUSETHENUMBEROFPIPEPENETRATIONSTHROUGHTHEWALLORROOFOFTHECABINETSHALLBERESTRICTEDTOTHEMINIMUMNECESSARYANDAMAXIMUMOF3FOREACHCYLINDERUNUSEDHOLES/PENETRATIONSSHALLBESEALEDINACCORDANCEWITHTHEUSERSINSTRUCTIONMANUALTHETHREEHOLESSHOULDHAVEAMAXIMUMDIAMETEROF10MMEACHNOTEINORDERTOMAINTAINTHEFIRERESISTANCEASTESTEDANDSPECIFIEDINACCORDANCEWITHANNEXASEEA41,ITISRECOMMENDEDTHATTHEPIPESAREMADEFROMSTAINLESSSTEELORFROMAMATERIALOFSIMILARTHERMALCONDUCTIVITY56INSTALLATIONOFELECTRICCABLESWHEREAPPROPRIATETHENUMBEROFPENETRATIONSTHROUGHTHEWALLORROOFOFTHECABINETSHALLBERESTRICTEDTOTHEMINIMUMNECESSARYANDAMAXIMUMOF2FOREACHCYLINDERUNUSEDHOLES/PENETRATIONSSHALLBESEALEDINACCORDANCEWITHTHEUSERSINSTRUCTIONMANUALTHETWOHOLESSHOULDBEAMAXIMUMDIAMETEROF20MMEACH6FIRERESISTANCETHEFIRERESISTANCEOFTHECABINETFORSTORINGPRESSURISEDGASCYLINDERSSHALLBEDETERMINEDBYATYPETESTTHISTYPETESTISPERFORMEDBYHEATINGTHECABINETINAFURNACEACCORDINGTOTHETIMETEMPERATURECURVEDESCRIBEDINCLAUSE511OFEN136311999ANDMEASURINGTHETEMPERATUREINCREASEONTHESURFACEOFANEMPTYGASCYLINDERWITHINTHECABINETTHETEMPERATUREINCREASEONTHESURFACEOFTHECYLINDERVALVESPANNERFLATSEEFIGUREA1SHALLNOTEXCEED50KTESTDETAILSAREGIVENINANNEXA7INFORMATIONTOBESUPPLIEDTHECABINETMANUFACTURERSHALLSUPPLYWITHTHECABINETAUSERINFORMATIONMANUAL,WHICHINCLUDESATLEASTTHEFOLLOWINGAINSTRUCTIONSFORCORRECTCABINETINSTALLATIONBMAXIMUMCOMBINEDVOLUMETRICCAPACITYOFTHEGASCYLINDERSSTOREDWITHINTHECABINETCSAFETYPROCEDUREINSTRUCTIONSINTHEEVENTOFFIRE,PARTICULARLYTHEMINIMUMTIME,WHENAFTERAFIRE,THEDOORSCANBESAFELYOPENEDDINSTRUCTIONSCONCERNINGTHEEFFECTOFGASPIPESPASSINGTHROUGHPENETRATIONOFTHEWALLSANDROOFOFTHECABINET,PARTICULARLYTHEPOTENTIALOFREDUCEDFIRERESISTANCEEINSTRUCTIONSTOCORRECTLYSEALTHEUNUSEDGASPIPEFEEDSTHROUGHTHECABINETPENETRATIONTOTHECABINETSWALLSANDROOFFWARNINGTHATSTORINGCORROSIVEGASESWILLADVERSELYAFFECTTHEEFFECTIVENESSOFTHEINLETANDEXHAUSTCLOSINGMECHANISMSWWWBZFXWCOMEN1447022006E8GINSTRUCTIONSTOCHECKTHATINSTALLATIONOFTHEVENTILATIONSYSTEM,IFCARRIEDOUT,ISCORRECTLYREALISEDFOREXAMPLEBYUSINGASMOKETUBEHRECOMMENDATIONTOUNDERTAKEREGULARINSPECTIONANDMAINTENANCEISUPPLIERSDECLARATIONOFCONFORMITYORTHECERTIFICATESOFCONFORMITYOFATESTHOUSE8MANUFACTURERSMARKINGANDLABELLINGTHEFOLLOWINGWHICHSHOULDBEALEGIBLESIZE,SHALLBEFIXEDINAVISIBLEPOSITIONANDONTHEFRONTOFTHECABINETAFIRERESISTANCECLASS,SPECIFIEDINMINUTES,EGTYPEG15,G30,G60ORG90BINSTRUCTIONTHATTHEDOORSSHALLBEKEPTCLOSEDCSAFETYSIGNINACCORDANCEWITHISO3864ASWARNINGOFPRESSURISEDGASCYLINDERSDNAMEAND/ORTRADEMARKOFTHEMANUFACTUREREMODELNUMBER,YEAROFCONSTRUCTIONAND,IFAPPROPRIATE,SERIALNUMBERFMARKINGOFTHEINLETANDEXHAUSTCONNECTIONSTODIFFERENTIATEBETWEENTHEMGADVICETOREADTHEUSERINSTRUCTIONMANUALWWWBZFXWCOMEN1447022006E9ANNEXANORMATIVETYPEGTESTINGTODETERMINEFIRERESISTANCEA1PRINCIPLETHESAFETYCABINETISEXPOSEDTOFLAMESINASUITABLEFURNACESOTHATASTANDARDTIMETEMPERATURECURVEISGENERATEDASSPECIFIEDINCLAUSE511OFEN136311999THETEMPERATUREINCREASE,ANDTHETIMETAKENUNTILTHETEMPERATUREINCREASEREACHES50KASMEASUREDONTHESURFACEOFTHEVALVESPANNERFLATONTHEEMPTYGASCYLINDERVALVE,SHALLBERECORDEDNOTETHEFIRERESISTANCEOFCABINETSSTORINGPRESSURISEDGASCYLINDERSEN144702ISNOTCOMPARABLEWITHTHEFIRERESISTANCEOFCABINETSTOSTOREFLAMMABLELIQUIDSEN144701DUETOTHEDIFFERENTMETHODSOFMEASURINGTHETEMPERATURESINVOLVEDINDETERMININGTHE“TIMETAKENFORTTORISE”SEETABLE1A2TESTINGAPPARATUSANDTESTMETHODSA21FURNACETHEFURNACESHALLBEARRANGEDSOTHATTHEDOORS,WALLS,ROOFANDFLOOROFTHETESTEDCABINETRECEIVEEQUALHEATCONDITIONSBUTWITHOUTFLAMESDIRECTLYTOUCHINGTHECABINETBODYA22MEASURINGEQUIPMENTMEASURINGEQUIPMENTFORMONITORINGTHEAMBIENTTEMPERATURE,FURNACETEMPERATURE,TEMPERATUREOFTHEWALLOFTHECABINETANDTHETEMPERATUREONTHESURFACEOFTHEGASCYLINDERSHALLBEINACCORDANCEWITHTHEREQUIREMENTSOFEN136311999THEMEANSOFHEATINGSHALLBEINACCORDANCEWITHTHEREQUIREMENTSOFEN136311999A23WEIGHINGSYSTEMAWEIGHINGSYSTEMSHALLBEUSEDWITHAMAXIMUMPERMITTEDLOADOF500GANDAMAXIMUMPOSSIBLEREADINGERROROF1PLUSASECONDSYSTEMFORWEIGHINGTHECABINET,ALSOWITHAMAXIMUMPOSSIBLEREADINGERROROF1A3TESTMODELSA31QUANTITYANDDESCRIPTIONOFTESTMODELSFORTESTINGTHEFIRERESISTANCE,TWOCABINETSOFTHESAMEMODELSHALLBEPROVIDEDONECABINETSHALLBEUSEDTOCONDUCTTHEFIRETESTANDTHEOTHERTODETERMINETHEHUMIDITYOFTHEINSULATIONMATERIALANDTOVERIFYTHEDESIGNANDSPECIFICATIONSOFTHECABINETDETAILEDCONSTRUCTIONDRAWINGSWITHSPECIFICATIONSSHALLBEPROVIDED,WHICHSHALLINCLUDETHEFOLLOWINGAINNERANDOUTERDIMENSIONSBSPECIFICATIONOFALLMATERIALSUSEDINTHECABINETCONSTRUCTIONCSHEETSTEELTHICKNESSDINSULATINGMATERIALTHICKNESSEGAPDIMENSIONSAROUNDANDBETWEENTHEDOORSANDDOORSEALSWWWBZFXWCOMEN1447022006E10FINLETANDEXHAUSTAIRCLOSINGMECHANISMGWELDEDANDOTHERFIXINGSANDTHEIRDESIGNANDSTANDARDOFWORKMANSHIPHMANUFACTURERSINFORMATIONONTHEMATERIALSORCOMPONENTSTHATHAVEABEARINGONTHEFIREPERFORMANCEOFTHECABINETA32PRELIMINARYEXAMINATIONOFTHETESTMODELBEFOREACTUALFIRETESTING,THETESTMODELSHALLBECHECKEDFORCONFORMITYWITHDRAWINGSPECIFICATIONSANYDIFFERENCESFOUNDSHALLBEADDEDTOTHEDRAWINGSANDSPECIFICATIONSTHEWEIGHTOFEACHTESTMODELSHALLBEDETERMINEDPHOTOGRAPHICDOCUMENTATIONSHALLBEPERFORMEDBOTHBEFOREANDAFTERTESTINGWITHVIEWSOFTHEOPENANDCLOSEDCABINET,ASWELLASDETAILEDVIEWSOFTHEDOORS,CONDITIONSOFSEALS,ETCBEFOREFIRETESTINGBEGINS,IFPRESENT,APPROXIMATELY250GINEACHSAMPLE,FROMTHREEDIFFERENTAREASEGDOORANDWALLOFONEOFTHECABINETS,SHALLBETAKENTHETHREESAMPLESSHALLBEWEIGHEDANDTHENDRIEDFOR24HOURSAT401C,ATARELATIVEHUMIDITYOF50,AFTERWHICHTHEMOISTURECONTENTISCALCULATEDNONEOFTHETHREESAMPLESSHALLWEIGHLESSTHAN95OFTHEORIGINALWEIGHTA4PREPARATIONOFFIRETESTA41SAFETYCABINETINORDERTOLIMITTHESPACEBETWEENTHETOPOFTHECYLINDERSANDTHEINNERCEILINGOFTHECABINET,ITISRECOMMENDEDATTYPETESTINGTHATLARGECABINETSBETESTEDWITHLARGERCYLINDERSANDSMALLCABINETSWITHSMALLERCYLINDERSANEMPTY50LITREGASCYLINDERSHALLBEPLACEDNOFURTHERTHAN175MMFROMTHEINNERCEILINGOFTHECABINETTOTHEHIGHESTPOINTOFTHEGASCYLINDERVALVEMECHANISMASTAINLESSSTEELPIPEWITHA10MMOUTERDIAMETERANDA1MMWALLTHICKNESSSHALLBECONNECTEDTOTHEGASCYLINDERSOUTLETTHISPIPESHALLPENETRATETHETOPOFTHECABINETANDSHALLNOTEXCEED500MMINLENGTHINADDITION,ANELECTRICCABLEWITH3CONDUCTINGWIRESCROSSSECTION3X1,5MM2SHALLBEPOSITIONEDTHROUGHTHETOPOFTHECABINETHANGINGAPPROXIMATELY500MMINTOTHEINTERIOROFTHECABINETITSLENGTHOUTSIDETHECABINETSHALLBEAPPROXIMATELY100MMA42INSTALLATIONOFTESTMODELALLCABINETSARETOBETESTEDASFREESTANDINGSINGLECABINETSIFTHECABINETISUSEDONWHEELSORCASTORS,ITSHALLBETESTEDASSUCHTHEMODELSHALLBEPOSITIONEDWITHITSBACKWALLATAMINIMUMOF100MMFROMTHEFIREROOMWALLTHETESTSHALLBEPERFORMEDAWITHOPENINLETANDEXHAUSTOPENINGSSEECLAUSE521,BUTWITHOUTBEINGCONNECTEDTOANEXHAUSTAIRSYSTEMBWITHTHEDOORSCLOSEDANDLATCHEDCWITHANEMPTYGASCYLINDERINSIDETHECABINETWITHITSVALVEOPENANDASTAINLESSSTEELPIPECONNECTEDASSTATEDINCLAUSEA41THECYLINDERSHALLBEPLACEDINTHEMIDDLEOFTHECABINETINCASEOFDOUBLEDOORCABINETSAND100MMFROMTHEUNHINGEDSIDEOFASINGLEDOORCABINETINBOTHCASESTHECYLINDERSHALLBERESTRAINEDTOTHEBACKWALLWWWBZFXWCOMEN1447022006E11A43TEMPERATUREMEASURINGDEVICEPLACEMENTONANEMPTYGASCYLINDER,THEFOLLOWINGSURFACETEMPERATUREMEASURINGDEVICESSHALLBEFIXEDINPAIRSONEFACINGTOWARDSTHEDOORANDTHEOTHERFACINGTOWARDSTHENEARESTSIDEWALLINTHEFOLLOWINGPOSITIONSAONTHESPANNERFLAT,BETWEENVALVEANDCYLINDERBODYSEEFIGUREA1BONTHEMIDDLEOFTHESHOULDERRADIUSCHALFWAYUPTHECYLINDERDSURFACETEMPERATUREMEASURINGDEVICESFIXEDTOTHECEILING,FLOOR,WALLSANDDOORS,EACHINTHEMIDDLEOFTHESURFACEASSHOWNINFIGUREA1THETEMPERATUREMEASUREDATASHALLBEUSEDFORCLASSIFYINGTHECABINETSEETABLE1THERESULTSBTODSHALLBEUSEDASINFORMATIONFORTHETYPETESTREPORTBUTNOTASPARTOFCLASSIFYINGTHECABINETA44TEMPERATUREMEASURINGDEVICEPLACEMENTINTHEFIREROOMATLEASTFOURTEMPERATUREMEASURINGLOCATIONSAREREQUIREDASSHOWNINFIGUREA2ANDA3,EACH100MMAWAYFROMTHEWALL,CEILINGANDDOORSURFACESOFTHECABINETTHEYSHALLBELOCATEDCENTRALLYWITHRESPECTTOEACHSURFACETHEMEASUREMENTLOCATIONSSHALLBEATLEAST400MMDEEPINTOTHEFIREROOMA5FIRETESTINGPROCEDURETHECABINETFRONTWALL,SIDEWALLS,CEILINGANDFLOORSHALLBEHEATEDWITHFLAMES,ACCORDINGTOTHESTANDARDTEMPERATURETIMECURVEGIVENINEN136311999DURINGTHETIMEOFTEMPERATUREINCREASE,THETEMPERATURESOFALLTEMPERATUREMEASURINGDEVICESSHALLBERECORDEDCONTINUOUSLYA6TESTREPORTTHETESTREPORTSHALLINCLUDEATLEASTTHEFOLLOWINGAREFERENCETOTHISSTANDARDIEEN144702BNAMEOFTHETESTINGLABORATORY,TESTREPORTNUMBER,PLACEANDDATEOFTYPETESTINGCNAMEOFTHEMANUFACTURERDMANUFACTURERSPRODUCTANDIDENTIFICATIONCODEEWEIGHTOFBOTHTESTMODELSFDESCRIPTIONANDDRAWINGSOFTHETESTMODEL,INCLUDINGALLPERTINENTDIMENSIONS,BUILDINGMATERIALS,SEALS,SHUTTERS,ETCGRESULTSOFHUMIDITYTESTINGOFINSULATIONSEECLAUSEA32HDETAILSREGARDINGTHEPOSITIONINGOFTEMPERATUREMEASURINGDEVICESANDPROCEDURESIWHICHFUELWASUSEDINTHETESTJOBSERVATIONSDURINGTESTKCOMMENTABOUTTHESTURDINESSDURINGTHEHEATINGPROCESS,INSOFARASINFORMATIONISAVAILABLELINDICATIONOFTHEFIRERESISTANCECAPABILITYDURINGTHEFLAMINGPROCESS,INSOFARASINFORMATIONISAVAILABLEMPHOTOGRAPHSTAKENBEFOREANDAFTERTHETESTWWWBZFXWCOMEN1447022006E12KEY1POSITIONSFORTEMPERATUREMEASURINGDEVICESONTHEEMPTYGASCYLINDERANDTHEVALVESPANNERFLAT2POSITIONSFORTEMPERATUREMEASURINGDEVICESINTHESAFETYCABINETFIGUREA1TEMPERATUREMEASURINGDEVICESONTHEGASCYLINDERANDINTHECABINETPLANANDFRONTELEVATIONSHOWNWWWBZFXWCOMEN1447022006E13KEY1AIRTEMPERATUREMEASURINGDEVICE2SURFACETEMPERATUREMEASURINGDEVICEFIGUREA2TEM
温馨提示
- 1. 本站所有资源如无特殊说明,都需要本地电脑安装OFFICE2007和PDF阅读器。图纸软件为CAD,CAXA,PROE,UG,SolidWorks等.压缩文件请下载最新的WinRAR软件解压。
- 2. 本站的文档不包含任何第三方提供的附件图纸等,如果需要附件,请联系上传者。文件的所有权益归上传用户所有。
- 3. 本站RAR压缩包中若带图纸,网页内容里面会有图纸预览,若没有图纸预览就没有图纸。
- 4. 未经权益所有人同意不得将文件中的内容挪作商业或盈利用途。
- 5. 人人文库网仅提供信息存储空间,仅对用户上传内容的表现方式做保护处理,对用户上传分享的文档内容本身不做任何修改或编辑,并不能对任何下载内容负责。
- 6. 下载文件中如有侵权或不适当内容,请与我们联系,我们立即纠正。
- 7. 本站不保证下载资源的准确性、安全性和完整性, 同时也不承担用户因使用这些下载资源对自己和他人造成任何形式的伤害或损失。
最新文档
- 经济学基础理论与现实应用分析试题
- 记忆里的那个英雄人物作文7篇
- 农业自然灾害防控合作协议
- 专利申请及技术转让出资证明书(8篇)
- 产品购销协议合同书
- 环境科学污水处理案例分析试题
- 2025美甲师高级考试试卷:美甲行业创新发展策略与市场分析
- 数学分析基础应用题库
- 2025年工艺品及其他制造产品项目立项申请报告
- 2025年征信国际合作案例分析试题集
- 育婴员考试题型及答案
- 科室建立血糖管理制度
- 四川成都东方广益投资有限公司下属企业招聘笔试题库2025
- 物业小饭桌管理制度
- 2025年湖南省普通高中学业水平考试合格性考试模拟试题(长郡版高一生物)(原卷版)
- 2025春国家开放大学《思想道德与法治》终考大作业答案
- 2025年广东省广州市白云区中考语文二模试卷
- 【英语(新高考Ⅰ卷)】2025年普通高等学校招生全国统一考试
- 2025企业并购合同协议模板
- 2025年天津市河西区中考二模数学试题(含部分答案)
- 医院培训课件:《药品不良反应报告和监测工作简介》
评论
0/150
提交评论