




免费预览已结束,剩余44页可下载查看
下载本文档
版权说明:本文档由用户提供并上传,收益归属内容提供方,若内容存在侵权,请进行举报或认领
文档简介
摘要本设计是成都*饭店综合楼中央空调设计,该饭店为十三层建筑,并设有地下室,总建筑面积12351m2,总层高43m。空调设计中,一、二层的大空间(商场、大堂、大堂吧等)采用全空气一次回风的空气处理方案,从节能的角度考虑,采用露点送风。空气处理机组设在每层的空调机房内,新回风经集中处理后送入各空调房间。气流组织采用上送上回的气流组织形式,送风口选用方形散流器,回风口采用单层百叶回风口。其余空调房间(办公室、客房、包间)因面积较小,采用风机盘管加新风系统,将室外新风处理到低于室内空气焓值的状态,承担室内全部湿负荷和部分冷负荷。新风由设置在走廊内的吊顶新风机组处理后送入各房间,送风采用双层百叶送风口。风机盘管送风选用侧送式,安装形式为卧式暗装。空调用制冷机房设在地下室,选用两台螺杆式冷水机组。夏天使用冷水机组提供的7/12的冷水,冬天由换热器将来自集中锅炉房的95/70的锅炉供水转换为60/50的热水后,送入各房间。水管路采用两管制。冷却塔置于屋顶,每台冷水机组各配一台。关键字:空调设计,全空气系统,风机盘管系统,冷水机组abstractthis design is the chengdu *hotel synthesis building central air conditioning design, this hotel is 13 constructs, and is equipped with the basement, total floor space 13000m2.total building store height 43m. in air conditioning design, 1f and 2f big spaces (market, great hall, great hall and so on) use the entire air time to return to the wind the air processing plan, from energy conservation angle consideration, uses the dew point blast. the air processing unit is located in each level in the air conditioning engine room, new、returns to the wind to send in various air conditioned room after centralism processing, the air current organization form used on delivers the other day, delivers the gusty area to select square shape drifting. returns to the gusty area to use the monolayer drifting to return to the gusty area, other air conditioned rooms (example office, guest room, package) because the area is smaller, uses the air blower plate tube to add the new atmosphere system, outside the new atmosphere will process to is lower than in the room the air enthalpy value condition, undertakes in the room completely the wet load and the partial cold loads, the new atmosphere by establishes the suspended ceiling new atmosphere unit processes after the corridor sends in various rooms, the blast uses double-decked drifting delivers the gusty area, the air blower plate tube blast selects the side to deliver the type, installs the form for the horizontal-type dark attire. the air conditioning refrigeration engine room is located in the basement, selects two screw rods types cold water unit, summer uses 7/12 cold water which the cold water unit provides, winter the heat interchanger future since will concentrate the boiler room 95/70 water transformation is 60/50 hot water, sends in various rooms, the water pipeline uses two. the cooling tower sets to the roof, each cold water unit respectively matches.key word: air conditioning design, entire air system, air blower plate tube system, cold water unit.第一章 绪论第一节 空气调节的含义建筑是人们生活与工作的场所。现代人类大约有五分之四的时间是在建筑中度过。人们已逐渐认识到,建筑环境对人类的寿命、工作效率、产品质量起着极为重要的作用。人类从穴居到居住现代建筑的漫长发展道路上,始终不懈地改善室内环境,以满足人类自身生活、工作对环境的要求,和满足生产、科学实验对环境的要求。人们对现代建筑的要求,不只有挡风遮雨的功能,而且还应是一个温湿度宜人、空气清新、光照柔和、宁静舒适的环境。生产与科学实验对环境提出了更苛刻的条件,如计算室或标准量具生产环境要求温度恒定(称恒温),纺织车间要求湿度恒定(称恒湿),有些合成纤维的生产要求恒温恒湿,半导体器件、磁头、磁鼓生产要求对环境中的灰尘有严格的控制,等等。这些人类自身对环境的要求和生产、科学实验对环境的要求导致了建筑环境控制技术的产生与罚展,并且已形成了一门独立的学科。建筑环境学中指出,建筑环境由热湿环境、室内空气品质、室内光环境和声环境所组成。空气调节是控制建筑热湿环境和室内空气品质的技术,同时也包含对系统本身所产生噪声的控制。 空气调节(air conditioning)实现某一房间或空间内的温度、湿度、洁净度和空气流动速度等进行调节与控制,并提供足够量的新鲜空气。空气调节简称空调。空调可以实现对建筑热湿环境、空气品质全面进行控制,或是说它包含了采暖功能和通风的部分功能。实际应用中并不是任何场合都需要用空调对所用的环境参数进行调节与控制,例如,寒冷地区,有些建筑只需要采暖;又如有些生产场所,只需要用通风对污染物进行控制,而对温湿度并无严格的要求。尤其是利用自然通风来消除室内余热余湿,可以大大减少能量消耗和设备费用,应尽量优先采用。第二节 空调技术的发展概况早在秦、汉年间,我国就有了以天然冰作冷源对房间进行冷却的“空调房间”,据艺文志记载:“大秦国有五宫殿,以水晶为柱拱,称水晶宫,内实以冰,遇夏开放。”尽管我们古老文明也创造了采暖通风空调的应用技术,但现代意义上的采暖通风空调技术的起源在西方。1904年在纽约建成斯托克斯交易所空调系统(制冷量450冷冻,即1406kw),同一时间在德国一剧院建成类似的空调系统。1911年美国开利(karrier,w.h.)博士发表了湿空气的热力参数计算公式,而后形成了现在广为应用的湿空气焓湿图,使得空调的计算更为合理。到1940年全美国制冷机总安装功率5106kw中有16%用于空调。而今天在发达国家中,“空调”一词已被一般人所了解,家用空调器在家庭中应用已相当普及,1996年日本销售家用空调器811.6万台。美国家用空调器销量一直保持在250160万台/年。现代的采暖通风空调技术在我国是近几十年发展起来的。在1949年前,只有在大城市的高级建筑物中才空调技术的应用,设备都是来自舶来品。上海大光明影院是最早用集中式空调系统的建筑物,建于1931年,采用离心式冷水机组。新中国成立后,空调技术才得到迅速发展。在20世纪50年代,迎来了工业建筑第一次高潮,前苏联援建了156项工程,同时带进了前苏联的空调技术和设备,这时工艺性空调也得到了发展,例如在大工厂中建有恒温恒湿的计量室,纺织工厂设有以湿度控制为主的空调系统。但当时基本上没有空调产品和专门为空调用的制冷设备。20世纪6070年代,我国经济建设走“独立自主,自力更生”的发展道路,从而形成了空调技术发展的时代特点。从仿制前苏联产品转向自主开发。这段时间舒适性空调也有了一些应用,主要应用在高级宾馆、会堂、体育馆、剧场等公共建筑中。也开发了一些空调产品,如jw型组合式空调机、恒温恒湿式空调机、除湿机、专为空调用的活塞式冷水机组等。1975年颁布了工业企业采暖通风和空气调节设计规范(tj1975),从而结束了空调工程设计无章可循的历史。这一规范也体现了我国专业工作者的一部分研究成果。20世纪8090年代是空调技术发展最快的时期。这时期是我国经济转轨时期,而空调也从原来主要服务对象工业转向民用。从南到北的星级宾馆都装有空调,最差的也装有分体式或窗式空调器。商场、娱乐场所、餐饮店、体育馆、高档办公楼中设空调已经很普遍了,而空调器也普遍进入了家庭。中国空调的市场潜力很大,预示着行业的发展前景远大。展望21世纪空调行业的发展,必将是走向一个稳步的可持续发展的道路。第三节 中央空调的发展趋势随着我国经济的持续增长,国民收入逐步提高,人们生活水平日益提高,家庭居住条件日益改善,人们对家居环境的舒适性要求越来越高,对家用中央空调的需求越来越大,空调成为人们家居生活不可缺少的重要组成部分。但由于我国是一个幅员辽阔、地理、气候条件分布不匀的国家,家居中央空调的使用情况多种多样,分布差异较大。华东沿海一带人们生活水平普遍较高,空调已不仅仅是用来降温,而是越来越多的用户都认为必须改善空气质量,提高空气质量,上述三种空调已不仅仅是单一使用,而是有机地结合在一起,增加新风热交换器。其次,经济发展水平地区差异较大,在不同的地区人们对家庭空调的需求不一样。即使在同一地区,由于人们的收水平不同,住宅形式也多种多样,而且生活习惯也不尽相同,因此对家用空调的需求也是多层次的。从环境和能源角度考虑,目前我国的环境污染问题较为突出,许多大中型城市出现“热岛”效应、空气污染等现象,首先,我国家用空调的发展必须注重节能性,提高空调的能效比值,其次,减少对环境的影响,降低空调机的噪声和对周围环境空气质量的污染。再次,对各种形式的家用中央空调进行研究和开发,在研究和设计进程中,充分考虑我国的具体国情,生产和开发各种适合中国国情的家用中央空调系统。第二章 概述第一节 工程概况该饭店为十三层建筑,并有地下室,总建筑面积为12351m2。一层为大堂、商场、大堂吧、办公室,层高4.5m;二层为中餐厅、包间、中餐操作间大堂上空等,层高4.5m;三层为客房、男、女更衣室、游泳池、网球场等,层高4.5m;四十三层为标准客房,层高3.3m。地下室为制冷、空调机房、水泵房、配电室等,层高4.2m;局部顶层为水箱间和电梯机房,层高3.3m。总层高为43m。第二节 设计依据一、建设单位设计书及甲方提供资料中与本专业设计有关内容;二、建筑专业提供的建筑图纸,包括一至十三层建筑平面图,地下室平面图,建筑物立面图、剖面图等;三、有关规范(一)采暖通风与空气调节设计规范(gb50019-2003);(二)民用建筑设计防火规范(gbj16-87)(2001年);(三)民用建筑热工设计规范(gb50176-93);(四)采暖通风与空气调节术语标准(gb50155-92);(五)旅游诱馆建筑热工与空气调节节能设计标准(gb50189-93);(六)通风与空调工程施工质量验收规范(gb50243-2002);(七)全国民用建筑工程设计技术措施(暖通空调.动力-2003)。第三节 设计概况一、风系统: 一层的101(大堂)、102(商场)、103(办公室)、104(大堂吧)采用全空气一次回风系统,其他房间(105114)采用风机盘管加独立新风系统,新风由设置在走廊上空的吊顶新风机组提供;二层的201(走廊)、202204(包间)、205(厨房操作间)、206(中餐厅)、214(包间)采用全空气一次回风系统,其他房间(207213)采用风机盘管加独立新风系统,新风由设置在走廊上空的吊顶新风机组提供;三十三层各房间采用风机盘管加独立新风系统,新风由设置在走廊上空的吊顶新风机组提供。二、水系统:为双管同程式,夏季空调用水供回水温度7/12:冬季为 60/50。三、风机盘管:风机盘管配带温控器.季节转换开关及三速开关,并在供水支管上设电动三通阀, 可根据温度调节电动三通调节阀及风机转数。第四节 原始资料一、室外空气设计参数及工艺资料(一)室外空气设计参数查采暖通风与空气调节设计规范jb50019-2003。表1 成都地区室外气象参数纬度海拔m大气压力kpa室外平均风速m/s室外计算干球温度冬季室外计算相对湿度 %夏季室外计算湿球温度3040505.9冬季夏季冬季夏季冬季夏季8026.796.3294.770.91.1136.1(二)室内空气设计参数及工艺资料如下表所示 表2 室内空气设计参数房间名称干球温度()相对湿度(%)新风量(m3/h.人)人员密度(人m2)照明功率(w/m2)夏季冬季夏季冬季商 场2528202255654055182014050中餐厅2426202255654050250.540操作间25271820300.2100贵宾室2426202255654050400.230多功能厅2426202255654050400.22530游泳池2527222460705060300.230客 房24262024556540505023室15会议室2527202255703050300.53040办公室2527202455654050300.220大堂、中厅大堂吧2527172055653050中厅、堂吧10,大堂00.120二、动力资料1、水源:城市自来水。2、电源:220/380v50hz民用动力电。3、热源:由集中锅炉房供给95/70的热水。4、冷源:根据负荷计算设计制冷站,冷水供回水温度为712。三、围护结构资料(一)屋面:加气混凝土保温屋面 ,ii型,k0.83w/m2k;(二)外墙:砖泡沫混凝土 + 木丝板白灰粉刷 ,ii型墙,k0.9 w/m2k;(三)外窗:采用塑钢窗,中空玻璃,k3.9 w/m2k;(四)门:根据用途不同查有关资料确定传热系数值;(五)内墙:采用200厚kp1型空心砖,k0.58w/m2k,两侧各抹20厚水泥砂浆;(六)楼板:120厚钢筋混凝土楼板,40厚水泥珍珠岩砂浆垫层,k2.0w/m2k;(七)楼梯间:为不使用空调区域,内抹30厚保温砂浆。第三章 负荷计算第一节 夏季空调冷负荷计算 目前,在我国暖通空调工程中,常采用冷负荷系数法和谐波反应法计算空调冷负荷,它们都是便于在工程上进行手算的一种简化计算方法。本设计夏季冷负荷计算采用冷负荷系数法,各项冷负荷的组成及其计算方法如下(以101房间为例):一、外墙和屋面瞬时传热引起的冷负荷在日射和室外气温综合作用下,外墙和屋面瞬变传热引起的逐时冷负荷可按下式计算: 式(3.1)式中: -外墙和屋面瞬时传热引起的逐时冷负荷,w; -外墙和屋面的面积,m2; -外墙和屋面的传热系数,w/(m2/); -外墙和屋面的冷负荷计算温度的逐时值,见暖通空调附录2-4、2-5;-地点修正系数,见暖通空调附录2-6;-外表面放热系数修正值,见暖通空调表2-8;-吸收系数修正值,见暖通空调表2-9;-室内计算温度,。表3 101房间东外墙(窗)瞬时传热冷负荷时间tc()tdtrtkaqc()8:0026.9-125.926-0.13.9(5.72+13.8)9-8.42.1=209.16-81.57249:0027.926.90.9734.151610:00292821631.44811:0029.928.92.92365.612:0030.829.83.83099.75113:0031.530.54.53670.75814:0031.930.94.93997.04815:0032.231.25.24241.76516:0032.231.25.24241.76517:00323154078.6218:0031.630.64.63752.3319:0030.829.83.83099.75120:0029.928.92.92365.621:0029.128.12.11713.0222:0028.427.41.41142.01423:0027.826.80.8652.57920:0027.226.20.2163.1448二、外玻璃窗瞬变传热引起的冷负荷在室内外温差作用下,通过外玻璃窗瞬变传热引起的冷负荷可按下式进行计算: 式(3.2)式中: -外玻璃窗瞬时传热引起的冷负荷,w; -外玻璃窗传热系数,w/(m2/); -窗口面积,m2; -玻璃窗的冷负荷计算温度的逐时值,见暖通空调附录2-10; -地点修正系数,见暖通空调附录2-11;-室内计算温度,。表4 101房间南外墙冷负荷时间tc()tdkktc()trtkaqc()8:0034.6-31.040.9731.87808265.878080.95.44.5+12.39=135714.18679:0034.231.474565.47456665.15910:0033.931.171925.17192628.388311:0033.530.76844.7684579.360612:0033.230.465764.46576542.589813:0032.930.163124.16312505.819114:0032.830.062244.06224493.562215:0032.930.163124.16312505.819116:0033.130.364884.36488530.332917:0033.430.667524.66752567.103718:0033.931.171925.17192628.388319:0034.431.676325.67632689.672920:0034.932.180726.18072750.957521:0035.332.584246.58424799.985222:0035.732.987766.98776849.012823:003633.29047.2904885.78360:0036.133.391287.39128898.0405表5 101房间北外墙冷负荷时间tc()tdkktc()trtkatqc()8:0032.3-11.040.9731.67632265.676320.95.49=48.60.374.48479:0032.129.356083.3560844.038510:0031.829.053443.0534440.067211:0031.628.851682.8516837.419712:0031.428.649922.6499234.772313:0031.328.549042.5490433.448514:0031.228.448162.4481632.124815:0031.228.448162.4481632.124816:0031.328.549042.5490433.448517:0031.428.649922.6499234.772318:0031.628.851682.8516837.419719:0031.829.053443.0534440.067220:0032.129.356083.3560844.038521:0032.429.658723.6587248.009722:0032.629.860483.8604850.657223:0032.930.163124.1631254.62850:0033.130.364884.3648857.276三、透过玻璃窗的日射得热引起的冷负荷透过玻璃窗进入室内的日射得热分为两部分,即透过玻璃窗直接进入室内的太阳辐射热和窗玻璃吸收太阳辐射后传入室内的热量。 透过玻璃窗进入室内的日射得热形成的逐时冷负荷可按下式计算: 式(3.3)式中: -透过玻璃窗的日射得热引起的冷负荷,w; -有效面积系数,见暖通空调附录2-15; -窗口面积,m2; -窗玻璃的遮阳系数,见暖通空调附录2-13;-窗内遮阳设施的遮阳系数,见暖通空调附录2-14;-最大日射的热因数,w/ m2,见暖通空调附录2-12;-窗玻璃的冷负荷系数,见暖通空调附录2-162-19。表6 101房间东外墙(窗)透入日射得热引起的冷负荷时间clqdj,maxcc,sawqc()8:000.825380.860.50.430.75209.16=156.8729758.059:000.7928669.3410:000.5921411.2811:000.3813790.3212:000.248709.67313:000.248709.67314:000.238346.7715:000.217620.96416:000.186532.25517:000.155443.54618:000.113991.93419:000.082903.22420:000.072540.32121:000.072540.32122:000.062177.41823:000.062177.4180:000.062177.418四、人体散热形成的冷负荷 人体散热与性别、年龄、衣着、劳动强度及周围环境条件(温度.湿度等)等多种因素有关。人体散热的潜热量和对流热直接形成瞬时冷负荷,而辐射散发的热量将会形成滞后冷负荷。因此,应采用相应的冷负荷系数进行计算。在本设计中,为了计算的方便,计算以成年男子散热量为计算基础。而对于不同功能的建筑物中有各类人员(成年男子.女子.儿童等)不同的组成进行修正,为此,引入群集系数。人体显热散热引起的冷负荷计算式为: 式(3.4)式中: -人体显热散热形成的冷负荷,w;-不同室温和劳动性质成年男子显热散热量,w,见暖通空调表2-13;-室内全部人数;-群集系数,见暖通空调表2-12;-人体显热散热冷负荷系数,见暖通空调附录2-23。 人体潜热散热引起的冷负荷计算式为: 式(3.5)式中: -人体潜热散热形成的冷负荷,w;-不同室温和劳动性质成年男子显热散热量,w,见暖通空调表2-13;-室内全部人数;-群集系数。表7 101房间人员散热引起的冷负荷(8-24h)时间clqqsnqc()qlqc合计8:000.16610.117.725.244.60.93404.8253733027.8943432.79:000.621568.6983027.8944596.610:000.71771.1113027.894479911:000.751897.6193027.8944925.512:000.791998.8253027.8945026.713:000.822074.733027.8945102.614:000.852150.6343027.8945178.515:000.872201.2373027.8945229.116:000.882226.5393027.8945254.417:000.92277.1423027.894530518:000.912302.4443027.8945330.319:000.922327.7453027.8945355.620:000.932353.0473027.8945380.921:000.942378.3493027.8945406.222:000.952403.653027.8945431.523:000.952403.653027.8945431.50:000.962428.9523027.8945456.8五、设备散热形成的冷负荷 式(3.6)式中: -设备显热散热形成的冷负荷,w,见暖通空调表2-20、2-21;-设备实际显热散热量,w;-设备显热散热冷负荷系数(本设计设备散热按稳态计算)。六、照明散热形成的冷负荷 式(3.7)式中: -照明散热形成的冷负荷,w;-镇流器消耗功率系数,当明装荧光灯的镇流器装在空调房间内时,取=1.2;当暗装荧光灯镇流器装设在顶棚内时,可取=1.0;-灯罩隔热系数,当荧光灯罩上部穿有小孔(下部为玻璃板),可利用自然通风散热于顶棚内时,取=0.50.6;而荧光灯罩无通风孔者=0.60.8;-照明工具所需功率;-照明散热冷负荷系数,见暖通空调附录2-22。表8 101房间照明散热引起的冷负荷时间clqn1n2nqc()8:000.291.21.020446.04=8920.83104.43849:000.262783.289610:000.232462.140811:000.22140.99212:000.192033.942413:000.171819.843214:000.151605.74415:000.141498.694416:000.121284.595217:000.111177.545618:000.373960.835219:000.677172.323220:000.717600.521621:000.747921.670422:000.768135.769623:000.798456.91840:000.818671.0176七、内围护结构冷负荷 本设计中内围护结构形成的冷负荷按稳态传热计算 式(3.8)式中: -内围护结构冷负荷,w; -内围护结构的传热系数,w/(m2/); -内围护结构的面积,m2; -夏季空调室外计算日平均温度,; -附加温升,查暖通空调教材取1;-室内计算温度,。表9 101房间(大堂)冷负荷汇总表东外墙瞬时负荷南外墙日射负荷南外墙冷负荷北外墙冷负荷人员散热冷负荷照明散热冷负荷合计-81.572429758.05076714.1867274.4846713432.719283104.438437002734.151628669.34158665.1590444.03848184596.591962783.2896374931631.44821411.28042628.3882840.06723974799.00462462.1408309722365.599613790.3162579.360637.4197454925.51252140.992238393099.75128709.673392542.5898434.77225025026.718822033.9424194473670.7588709.673392505.8190833.44850295102.623561819.8432198423997.04768346.770334493.5621632.12475555178.52831605.744196544241.76487620.964218505.8190832.12475555229.131461498.6944191284241.76486532.255044530.3329233.44850295254.433041284.5952178774078.625443.54587567.1036834.77225025305.03621177.5456166073752.33043991.933638628.3882837.4197455330.337783960.8352177013099.75122903.224464689.6728840.06723975355.639367172.3232192612365.59962540.321406750.9574844.03848185380.940947600.5216186821713.02042540.321406799.9851648.00972385406.242527921.6704184291142.01362177.418348849.0128450.65721865431.54418135.769617786652.57922177.418348885.783654.62846065431.54418456.918417659163.14482177.418348898.0405257.27595545456.845688671.017617424各房间冷负荷汇总表见附录1。第二节 冬季热负荷计算 建筑物冬季热负荷由围护结构耗热量和门窗缝隙渗入冷空气耗热量两部分组成,因空调建筑室内为正压,故本设计不考虑冷风渗透耗热量。围护结构耗热量又由围护结构基本耗热量和围护结构附加耗热量组成。 一、围护结构基本耗热量 式(3.9)式中: -围护结构基本耗热量,w; -围护结构的表面积,m2;-室内计算温度,;-冬季室外空气计算温度,;-围护结构温差修正系数。二、围护结构附加耗热量(一)朝向修正率 北、东北、西北朝向: 0; 冬、西朝向: -5%;东南、西南朝向: -10%15%;南向: -15%25%。(二)高度附加 当房间净高超过4m时,每增加1m,附加率为2%,但最大附加率不超过15%。高度附加率应加在基本耗热量和其他耗热量的总和上。(三)本设计未考虑风力附加和外门开启附加。(四)通过地面的温差传热通过地面的温差传热近似计算法。即把地面划分为四个地带,各地带有其确定的传热系数,按下式计算房间的地面温差传热量: 式(3.10)式中: -各计算地带面积,; -各计算地带的传热系数; 第一地带 ., 第二地带 ., 第三地带 ., 第四地带 .,计算地带划分的方法是:平行于建筑物的所有外墙,自外墙内表面起,向建筑内划分缩进2m划一个与外墙轮廓相同的区域,作为第一地带。如此向内划,每2m宽为一个地带。当距外墙内表面6m以后,皆属第四地带。应注意角隅房间的外墙角第一地带的面积增加4m 以补偿角传热的增强。各房间热负荷计算表见附录2。第三节 夏季、冬季湿负荷计算 湿负荷是指空调房间的湿源(人体散湿、敞开水表面散湿和地面积水等)向室内的散湿量,也就是维持室内含湿量恒定需从房间出去的湿量。 式(3.11)式中: -人体散湿量,kg/s;-室内全部人数;-群集系数;-成年男子的小时散湿量,g/h。 各房间湿负荷计算见附表3。第四章 空气处理方案的选择第一节 空调系统的分类 空调系统一般可按负担室内热湿负荷所用的介质分为全空气系统、全水系统、空气-水系统和冷剂系统。按空气处理设备的集中程度可分为集中式空调系统、半集中式空调系统和分散式空调系统。按被处理空气的来源又可分为封闭式系统、直流式系统和混合式系统。表10 几种空调系统特点比较系统特点封 闭 式系 统它所处理的空气全部来自空调房间本身,没有室外空气补充。这种系统冷、热耗量最省,但卫生效果差。这种系统应用于战时的地下庇护所等战备工程以及很少有人进出的仓库。全 新 风系 统它所处理的空气全部来自室外,室外空气经处理后送入室内,然后全部排出。这种系统空气品质好,但耗能,运行费用高。使用于不允许回风的场合,如放射性试验室以及散发大量有害物的车间等。一 次 回 风 系 统综合了封闭式系统和全新风系统的利和弊,采用一部分回风。这种系统既能满足卫生要求,又经济合理,故应用最广。一、一次回风系统此系统将空调机设置在专门的空调机房内,而用送风道向各空调房间供冷或供热。其特点是:(一)回风仅在热湿处理设备前混合一次;(二)可利用最大送风温差送风,当送风温差受限制时,利用再热满足送风温度;(三)因空调机设置在机房内,运转,维修较容易,能进行完全的空气过滤,产生振动,噪声传播的问题较少;(四)因送风量大,换气充分,再加上过滤完全,房间内的空气品质较好,特别是若设置回风机或排风机时,则可在过度季节利用新风进行供冷;(五)必须有大型的空调机房;(六)当房间空间较大而分区数少时,设备费较其他方式便宜。二、风机盘管加新风系统 该系统是将风机盘管设置在空调房间内,直接处理室内空气,新风机组设置在专门机房或吊顶,用风道向各空调房间内送入处理后的新风,其特点是:(一)优点:1、噪音较小,对于旅馆的客房,夜间低档运行的风机盘管机组,室内环境一般在3040db(a);2、具有个别控制的优越性。风机盘管机组的风机速度可分为高、中、低三档;水路系统采用冷热水自动控制温度调节器等,可灵活的调节各房间的温度;是内无人时机组可停止,运行经济、节能;3、系统分区进行调节控制容易。冷热符合按房间朝向、使用目的、使用时间等把系统分割为若干区域系统,进行分区控制;4、风机盘管机组体型小,布置和安装方便,属于系统的末端机组类型;5、占建筑空间少;6、对于将来建筑物的扩建,而相应增设风机盘管机组,实现比较容易。(二)缺点:1、因机组设在室内,有时与建筑布局产生矛盾,需要建筑上的协调与配合;2、因机组分散设置,台数较多时,维修管理工作量较大。随着机组质量提高,这一缺点将逐步减少;3、风机盘管机组方式本身解决新风量是困难的。在过渡季和冬季利用室外空气降温的时间较短;4、由于机组风机的静压小,在机组中不可能使用高性能的空气过滤器,空气洁净度不高;5、此外,由于风机盘管机组有旋转部分(风机、电动机),对加工质量要求较高。宫给机组的水系统管道保温要严格保证施工质量,防止系统运转时产生凝结水。(三)风机盘管与新风系统的容量匹配: 空调系统中的设备容量通常根据夏季冷负荷确定,以冬季负荷值进行校核。因冬季热水的供回水温差远远大于夏季的冷水供回水温差,故根据夏季冷负荷确定的设备,其容量一般能满足冬季要求。 本设计采用新风承担室内负荷的处理方式。此方式中,室内的部分冷负荷由风机盘管承担,新风冷湿负荷与室内的湿负荷及部分冷负荷由新风承担。该方案的优点是:风机盘管在干工况下运行,减少了系统对空气的污染。另外,据次选择的风机盘管噪声相应的小,当室内无人时,风机盘管随之停止运行,而新风系统的运行是不间断的,如此的方案使得室内无人时,室内的空气参数不会偏离设计值太远。三、新风量确定的一般原则 目前,我国空调设计中的新风确定原则仍用现行规范,设计手册中规定(或推荐)的原则。主要有以下三个依据:(一)卫生要求:在人长期停留的空调房间内,新鲜空气的多少对健康有直接影响。人体总要不断的吸进氧气,呼出二氧化碳一般按规
温馨提示
- 1. 本站所有资源如无特殊说明,都需要本地电脑安装OFFICE2007和PDF阅读器。图纸软件为CAD,CAXA,PROE,UG,SolidWorks等.压缩文件请下载最新的WinRAR软件解压。
- 2. 本站的文档不包含任何第三方提供的附件图纸等,如果需要附件,请联系上传者。文件的所有权益归上传用户所有。
- 3. 本站RAR压缩包中若带图纸,网页内容里面会有图纸预览,若没有图纸预览就没有图纸。
- 4. 未经权益所有人同意不得将文件中的内容挪作商业或盈利用途。
- 5. 人人文库网仅提供信息存储空间,仅对用户上传内容的表现方式做保护处理,对用户上传分享的文档内容本身不做任何修改或编辑,并不能对任何下载内容负责。
- 6. 下载文件中如有侵权或不适当内容,请与我们联系,我们立即纠正。
- 7. 本站不保证下载资源的准确性、安全性和完整性, 同时也不承担用户因使用这些下载资源对自己和他人造成任何形式的伤害或损失。
最新文档
- 2025的PVC管购销合同
- 纺织行业数字化转型试题及答案
- 2025湖南长沙市望城经开区招商投资有限公司招聘9人笔试参考题库附带答案详解
- 2025江西省江铜集团招573人笔试参考题库附带答案详解
- 2025年河南通航机场管理有限公司社会招聘23人笔试参考题库附带答案详解
- 2025山东东营中外运物流有限公司招聘5人笔试参考题库附带答案详解
- 纺织工程师考试常见问题解答试题及答案
- 轴承基础知识试题及答案
- 高程模型考试试题及答案
- 《人工智能原理》课件演示
- 新生儿医源性皮肤损伤的预防与护理课件
- 西安外国语大学
- 信息隐藏技术全套教学课件
- HEYTEA喜茶品牌产品介绍PPT模板
- 常见颅脑急症的CT、MRI诊断
- 各种传染病诊断标准
- 油气集输管线管道工程试运投产保驾方案
- 2023年云南省昆明市中考作文真题解析及欣赏:坚持的力量
- 出国举办经济贸易展览会审批管理办法
- 2016哈弗h6运动版维修手册与电路图1406线束01机舱
- 2023年江苏泰州市第四人民医院招考聘用高层次人才11人模拟备考试卷(共1000题含答案解析)
评论
0/150
提交评论