




已阅读5页,还剩17页未读, 继续免费阅读
版权说明:本文档由用户提供并上传,收益归属内容提供方,若内容存在侵权,请进行举报或认领
文档简介
installation and operation manual安装和操作手册505 digital governor数字调速器 for steam turbines蒸汽汽轮机with single 单一or split-range部分范围 actuators调节器volume 1manual 85017v1b第五章505运行操作run mode architecture运行模式体系结构the 505 is designed愿意 to be interfaced界面上 with through通过 a user-friendly用户界面友好的,用户容易掌握使用的service panel, 维修面板discrete and analog离散模拟 input/outputs or modbus communications.通讯 basic program基本程序architecture体系结构 is illustrated in figure 以插图说明见5-1. when the control is powered up 加电and afterthe brief下达 cpu self test自检测 has been completed完成, the control displays a ready status就绪状态(controlling parameter调节参数/push run or program). the 505s normal operating正常工作architecture is divided分成 into two sections到两部分零件: the run mode and the program mode.the program mode is used to configure the 505 for the specific application专用应用程序 andset all operating parameters工作参数 (see chapter 4). the run mode is simply仅仅 the normal正常turbine operation mode工作操作方式 and is used to view operating parameters and run theturbine. a service mode预检(服务)模式 is also同样 available可用 to make制做 additional另外附加的 on-line adjustments调整机构while the unit装置 is running. see volume 2 for information on the service mode.505愿意从界面上通过用户的友好界面进行服务与维修。其基本程序体系结构为离散模拟输入/输出与modbus通讯(插图说明见5-1)。当控制电源加电与cpu下达自检测完成后,控制面板显示ready status就绪状态(controlling parameter调节参数/push run or program)。505正常工作体系结构分为两部分,即:the run mode and the program mode(设置全部的工作参数见第四章)。运行模式仅为正常工作操作方式与用户去浏览工作参数和启动汽轮机。预检(服务)模式同样可用需制做另外附加的调整机构,当装置运行时可以在服务模式上看见容积信息。表5-1基本程序体系结构an overview of run mode keys and screens is shown in figure 5-2. this diagramshows all of the potential screens that could appear. however, only the screensthat are related to the 505s programmed functionality will appear. figure 5-2also shows the keys that are active for each screen. the hot keys (speed, aux,etc.) are always active if the function is programmed. the adjust up/down,enter, yes/no keys, however, are only active with certain screens. figure 5-2can be referred to, when determining what keys are active and what screens willappear on the display.运行模式控制键与屏显见表5-2综述,这个图表显示全部的下级屏显并显示出来。无论如何,屏幕仅显示与505程序功能有关的显示。表5-2也显示在屏幕上各功能键的功能。这些热键(speed, aux,etc.)总是在组态程序功能后处于激活状态。那些adj(adjust调整键)up/down、enter、 yes/no 键、不论何时仅在确定屏显时处于激活状态。表5-2能够查阅,当决定什么键是激活的和屏幕将要显示什么时。表5-2 运行模式综述tripcontrolling parameterremotemessagesmessagesmessagesmessages8messages7messages4extemal trip input shutdowndisabledenter shutdown buttoncontrolled shutdowninhibitedoverspeedmax actuatorenabledall speed probes failedvalve limiteractiveactuator #1 faultremote auxiliaryin conrtolactuator #2 faultauxillary controlaux input failedconfiguration errorcascade controlextemal trip 2start perm not met messagesextemal trip 3ready to start message6extemal trip 4manual start disabledextemal trip 5auto startinhibitedcomm link #1 tyipsemi auto start enabledcomm link #2 tyipidie/rated startin controlkw input failedauto start sequenceactive/not spd ctrltie breaker openedfrequency/speedactive w/rmt setptgenerator breaker opensynchronizingin ctrl w/rmt setptpower up trip load share/speedshutdown completeremote cascade/speedunits optionscascade/speed(for aux/casc)idie/rated messagesremote/speedpsimessage1speed/on-linekpastoppedspeed/off-linemwspeed/off-linekwmvg to idieaux messagesdegfat idie spd(if using aux enable)degcin crit bandmessage5t/hmvg to rateddisabledk#/hrat rated spdinhibited#/hrrtd inhibitedenabledkg/cm2idle inhibitedactive/not in ctrlbaractive w/rmt setptatmauto start messagesin conrtol(none)message 2remote conrtoldisabledhaltedaux messagesmvg low idie(if using aux as a limiter)at low idiemessage5mvg hi idieinhibitedin crit bandenabledat high idieenabled w/rmt setptmvg to ratedactive w/rmt setptcompletedactive/not lmtingcontrol w/rmt setptcontrol messagesin controlmessage3disabledinhibitedenabledin controlremote controlkeypad and displaythe 505 is a field configurable steam turbine control and operator control panel(ocp) integrated into one package. the 505s service panel consists of a 30-keykeypad and led display located on the front of the control. the led display hastwo, 24 character lines that can be used to display operating parameters andtrouble-shoot parameters in plain english. the service panel is used to configurethe 505, make on-line program adjustments, and operate the turbine/system.no additional panels are required to operate the turbine, every turbine controlfunction can be from the 505s front panel. however, the turbine can also beoperated remotely. every front panel control operation can be performedremotely through contacts or modbus communications. for safety purposes,however, the 505s overspeed test function cannot be performed through amodbus link.键区与显示505汽轮机控制配置范围与操作员控制面板(简称ocp)整合在一个安装包内。505维护操作面板同由30个键组成,键民led显示固定在前面板上,国led有两行显示,可显示24个字符供用户显示工作参数与用浅显的英语进行故障参数检修。这个面板是用配置505,做在线程序调整,与运行汽轮机系统。不需要另外附加面板支控制汽轮机,每次汽轮机控制功能可从505控制面板操作。无论何时汽轮机也能遥控操作。每次从控制面板操作都能完成任务。遥控通过接点或modbus通讯。出于安全的目的,无论何时,都不能把超速试验通过连接modbus来完成任务。run mode front panel keysfor a detailed description of each 505 key functionality see chapter 1.of the thirty front panel keys, not all are active at all times in the run mode.however, from the 505s service panel, the keys that are active will be apparentsince there is immediate display feedback when an active key is pressed. whena respective “hot” key (aux, casc, kw, etc.) function is not programmed, afunction not programmed message will be appear if the key is pressed.the following are generalizations when determining what keys will function:运行模式下的前面板键从详细的描述至每一个505键的功能见第一章的30个键的控制面板,在运行模式下它们不是总在激活状态下,而是在一定的时间内才可用。无论何时从505操作面板,那些可用的键总是有显示的,以后那儿有即时反馈显示,当键入活动中的按键时,当各自的热键(aux, casc, kw, etc.)功能没有组态时,如果按下此键时,将显示function not programmed信息,以下是通用的当决定什么时候将要键入什么功能时。starting proceduresrefer to the turbine manufacturers operating procedures for completeinformation on turbine start up, and chapter 3 of this manual for a step by stepprocedure, depending on the start mode selected. the following is a typical startupprocedure:起动过程在汽轮机启动前查阅汽轮机厂家的操作程序完善信息。比较第三章的手册一步一步的配置程序,依靠启动模式下的选择,下面是典型的启动程序(生产过程)。speed key screensfigure 5-4 shows the possible screens that may appear if the speed key ispressed. only the screens related to the speed controls programmedfunctionality will be displayed. in addition, the order of the screens may changedepending on the status of the control. screens 4, 5 and 6 will always appear. ifidle/rated is programmed, screen 1 will appear. if the auto start sequence ifprogrammed, screens 2 and 3 will appear. once the auto start sequence iscomplete, these screens no longer appear.转速键显示表5-4表示可能需要的显示,如按下speed键。仅显示与转速控制有关的程序功能补充,那些显示可能会变化,用控制面板开机。4、5、6、总是有显示的。如在空转/额定程序下,1将显示。如在按自动顺序启动程序下2、3、将显示。一次自动运行完成后,这些显示将不在显示。1# -selects rated选择额定 -selects idle选择空转2# yesselects continue auto sequence选择继续自动运行 noselects halt auto sequence选择停止、中断、暂停自动运行3#-increases speed setpt加速设定;-decreases speed setpt减速设定4# entet-direct entry of speed setpt直接确定转速设定 -increases speed setpt加速设定 -decreases speed setpt减速设定5#6#-increases gain settings增加增益设定 -decreases gain settings减少增益设定screen 1 shown only if idie/rated conrtol is configured and speed is less than the rated setpt(setpoint) .once above rated speed screen 1 appears after screen 4.screens 2&3 are shown only if auto start sequence is configured and speed has not reached the rate setpt.sereens 5&6 shown only if dynamics adjustments are usedthe asterisk (*) denotes a tunable parameter .to adjust this parameter the”symbol must be on the display line containing the asterisk the symbol is moved with the select key屏显1仅显示空转/额定的配置和低转速的额定设置。初次在屏显1上设定适当的转速后见屏显4.屏显2$3仅显示自动开机的配置和至额定转速的设置。屏显56仅显示用户动态可调。这(*)表示可调参数去用adj调节,这符号必须是在线显示状态下,然后移动选择键进行选择。idle/rated startfor details on the idle/rated startup, refer to chapter 3. when a run commandis issued, the 505 automatically displays the speed screen and shows theidle/rated status. the speed setpoint is instantly set to the actual turbinesspeed. to increase the speed to the programmed rated setpt setting, selectthe rated command. a rated command can be issued by pressing the frontpanel yes key from the idle/rtd screen (screen 1), closing the idle/ratedcontact (if programmed) or selecting a go to rated command from modbuscommunications.空载/额定启动空载/额定启动的详细资料,查阅第三章。当发出运行命令时,505自动显示速度和显示空载/额定状态。转速设置点就立即去设置汽轮机的转速。通过程序“rated setpt(额定转速设置点)”设置加速,选择额定转速命令。从idle/rtd屏显(screen 1)下,额定转速命令的发出可通过按下控制面板yes键,closing the idle/ratedcontact (if programmed) or selecting a go to rated command from modbuscommunications.(未用)when the speed setpoint is ramping to the rated setpoint setting it can bestopped at any point that is not within a critical speed avoidance band by issuinga speed setpt raise or lower command. this can be done by pressing theadjust up or down from the front panel speed screen (screens 1,2,3 or 4),closing a speed raise/lower contact input or selecting speed raise or lowerfrom a modbus communications link.当转速设置点是按坡度(曲线)时去额定转速设置点设置它时,它能暂停在任一点但不能在临界转速之内避免波动转速设置点升高或降低命令。通过按下控制面板选择speed屏显(屏显123或4),closing a speed raise升高/lower降低 contact input输入接点 or selecting speed raise or lower from a modbus communications link.the speed setpoint will again ramp to the rated speed setting if the ratedcommand is re-issued. to re-issue the rated command press the front panelyes key from the idl/rtd screen (screen 1), toggle the idle/rated contact openand closed again (if programmed) or select go to rated from a modbuscommunications link.这转速设置点将按坡度去设置额定转速如果额定命令是复位发出。这复位发出额定命令从idl/rtd屏显(屏显1)按下控制面板yes键,触发idl/rtd触点打开与关闭(if programmed) or select go to rated from a modbus communications link.the speed setpoint will ramp to the idle speed setting upon startup. however,the idle speed setting can be re-selected, when conditions allow, (see chapter3) by pressing the front panel no key from the idl/rtd screen (screen 1), openingthe idle/rated contact (if programmed), or selecting go to idle from a modbuscommunications link.这转速设置点将按坡度在启动上去设置空载转速,无论空载转速设置能否重选,当条件允许时,(看第三章)从idl/rtd屏显(屏显1)按下控制面板no键openingthe idle/rated contact (if programmed), or selecting go to idle from a modbuscommunications link.another feature of idle/rated function is the ramp to rated option which allowsthe speed setpoint to only move to the rated speed setting; idle is notselectable. this feature is configurable in the service mode only. when thisfeature is used with the idle/rated contact input, closing the contact results导致 in thespeed setpoint ramping to the rated speed setting and opening the contactstops the speed setpoint ramprather than selecting idle. to continue rampingto the rated speed setting, re-close the contact, press the front panel yes keyfrom the idl/rtd screen (screen 1) or select go to rated from modbuscommunications.另外idle/rated function的特点是曲线控制额定选项哪个允许转速设置点去仅传送额定转速设置,空载不能先择。这特点是仅在服务模式配置的。当这特点是用户在idle/rated接点输入时,闭合触点导致在转速设置点按曲线去额定转速设置与断开触点停止转速设定点曲线宁愿选择空载。继续曲线去额定转速设置,再次接通接点,从idl/rtd屏显(屏显1)按下控制面板yes键或select go to rated from modbus communicationstable 5-2 lists the idle/rated status messages that may appear on the front panel display and the meanings of each.桌面5-2列表是idle/rated状态信息,可能在面板上显示每一个信息含义。table 5-2. idle/rated messagesmessage 1 meaningstopped idle/rated ramp has been stopped空载/额定曲线已经停止mvg to idle speed setpt is moving to idle转速设定点是空载活动(移动)at idle spd speed setpt is at the idle setpt转速设定点是空载设置点in crit band speed setpt is moving through the critical avoidance band转速设定点是通过临界转速频率带mvg to rated speed setpt is moving to the rated setptat rated spd speed setpt is at the rated setptrtd inhibited selection of rated is not allowed不容许选择额定idle inhibited selection of idle is not allowed不容许选择空载the following indications are available through the modbus links: ramping toidle, at idle, turbine in critical speed band, ramping to rated, and at rated. inaddition to these indications, the idle speed setpoint and rated speed setpointanalog values are also available.下列各项表示可以通过在线modbus:曲线去空载、空载、汽轮机过临界转速频率、曲线去额定、额定。适当地添加这些指示,空载转速设定点与额定转速设定点模拟值也同样有效。auto start sequencewhen a run command is issued, the 505 automatically displays the speedscreen (unless used with the semiautomatic start mode) and shows the status ofthe auto start sequence (screen 2). the speed setpoint is instantly set to theturbines actual speed and the sequence will continue from this point. thissequence is automatic, however the sequence can be halted. halting the autostart sequence can be performed by pressing the front panel no key from thesequence status screen (screen 2), opening the halt/continue contact (ifprogrammed), selecting halt from a modbus communications link, or selectingspeed setpt raise or lower. to provide feedback, a relay can be programmedto indicate the auto start sequence is halted.自动启动顺序当运行命令发出时,505自动显示速度屏(除在半自动启动模式以外)和显示自动启动顺序的状态(屏显2)。转速设置点就开始汽轮机的实际转速与顺序将连续地从这点开始。这是自动启动顺序,无论何时程序都可暂停。暂停自动启动后可在程序状态屏(屏显2)按下控制键no键,暂停/继续开度(如组态),选择从modbus总线暂停,或选择转速设置点升高或降低。按规定反馈,编程后的继电器显示auto start sequence is halted.自动开机暂停。the sequence can be restarted again by pressing the front panel yes key fromthe sequence status screen (screen 2), closing the halt/continue contact, orselecting continue from a modbus communications link. table 5-3 lists the autostart status messages that may appear on the display and the meanings of each.从程序状态屏(屏显2)按下yes控制键可以重新开始程序,closing the halt/continue contact, or selecting continue from a modbus communications link。桌面5-3列表是自动开机状态显示的信息及每个含义。table 5-3. auto start messagesmessage 2 meaning含义disabled auto start sequence is disabled禁止自动开机顺序halted sequence has been halted程序暂停、中断mvg low idle speed setpt is moving to low idle转速设置点是空载低速移动(活动)at low idle speed setpt is holding at the low idle setpt转速设置点是维持空载低速设置点mvg hi idle speed setpt is moving to high idle转速设置点是空载高速移动(活动)in crit band speed setpt is moving through the critical avoidance band转速设置点是通过临界转速频率带at high idle speed setpt is holding at the high idle setpt转速设置点是维持空载高速设置点mvg to rated speed setpt is moving to rated setpt转速设置点是额定转速移动(活动)completed auto start sequence is completed自动开机顺序程序完成the following auto start sequence indications are available through the modbuslinks: setpt moving to min, setpt at low idle, ramping to high idle, setpt at highidle, turbine in critical speed band, ramping to rated, and at rated. in additionto these indications, the low idle speed setpoint, low idle delay time, timeremaining at low idle, low idle to high idle rate, high idle speed setpoint,high idle delay time, time remaining at high idle, high idle to rated rate,rated speed setpoint, run time (hours), and hours since trip analog valuesare also available providing comprehensive sequence information.下列各项表示自动开机是可以通过modbus在线的:设置点活动的分钟、设置点在空载低速、曲线空载高速、设置点在高速空载、汽轮机过临界转速频率、曲线额定、与额定。另外这些表示,低速空载转速设置点、低速空载延迟时间、低速空载剩余时间、低速至高速空载速率、高速空载转速设置点、高速空载延迟时间、高速空载剩余时间、高速空载至额定速率、额定转速设置点、运行时间(小时)、与自从模拟量报警值的时间同样有效只要综合程序信息。direct setpoint entrythe speed setpoint can be directly set to a specific value, that is not within acritical speed avoidance band, using the enter key from the speed setptscreen (screen 4). the messages that appear on the display are shown in figure5-5. there are limits on the range of the speed setpoint that can be entered. thespeed setpoint must be below the maximum governor setting and above the idlesetting. also, if the unit is driving a generator and the unit is on-line, the speedsetpoint cannot be set below the minimum load setting (tunable in the servicemode).直接进入设置点转速设定点能直接设置比值,就是不能进入临界转速频率,用户从转速设置点屏(屏显4)按enter键。这些信息将显示在屏幕上见表5-5。这能进入限制速度设置点范围。转速设置点必须在调速器最大设置以下与空载以上。同样,如果单位装置传动发电机与装置在线,转速设置点不能设置最低负载设置(在运行模式可调)the speed setpoint can also be directly entered from either of the modbus links,however, the allowed range is between the minimum and maximum governorspeed settings. the allowed setpoint range is limited between the minimum loadand the maximum governor settings if the unit is driving a generator and the unitis on-line. both the speed setpoint and the modbus entered speed setpoint areavailable over the communication link to provide feedback for directly enteredmodbus values.转速设置点也能直接进入从任一的或modbus在线的。无论何时,是在最大与最小调速器转速设置范围容许之间。容许设置点量程界限范围是在最低负荷与最大调速器设置之间如果单独传动发电机与在线装置。两者转速设置点与modbus进入转速设置点结果一样通信连接装置按规定反馈后直接进入modbus值figure 5-5. direct setpoint entryenternew setpoint values=*use number keys to set new setpt and press enter.使用数字键去设置新的设置点后按enterthe new setpoint value must be within the allowed setpoint range or the display will issue an error message.新的设置点值必须在容许设置点范围之内或显示错误信息。value *.* accepted公认的-press enter to continue继续the setpoint will move to the new entered value at the “entered rate.” the entered rate is defaulted to the slow rate setting but can be adjusted in the service mode if desired.selecting the adjust up or adjust down arrows will stop the setpoint at its present position.设置点将运行新的键入值在“键入速率。” 键入速率是默认的慢速设置但能在服务
温馨提示
- 1. 本站所有资源如无特殊说明,都需要本地电脑安装OFFICE2007和PDF阅读器。图纸软件为CAD,CAXA,PROE,UG,SolidWorks等.压缩文件请下载最新的WinRAR软件解压。
- 2. 本站的文档不包含任何第三方提供的附件图纸等,如果需要附件,请联系上传者。文件的所有权益归上传用户所有。
- 3. 本站RAR压缩包中若带图纸,网页内容里面会有图纸预览,若没有图纸预览就没有图纸。
- 4. 未经权益所有人同意不得将文件中的内容挪作商业或盈利用途。
- 5. 人人文库网仅提供信息存储空间,仅对用户上传内容的表现方式做保护处理,对用户上传分享的文档内容本身不做任何修改或编辑,并不能对任何下载内容负责。
- 6. 下载文件中如有侵权或不适当内容,请与我们联系,我们立即纠正。
- 7. 本站不保证下载资源的准确性、安全性和完整性, 同时也不承担用户因使用这些下载资源对自己和他人造成任何形式的伤害或损失。
最新文档
- 机器人安装自动化-洞察及研究
- 6.3.1角说课稿人教版数学七年级上册
- 2022-2023大同市平城区高三一模历史试题解析及答案
- 2022-2023学年东莞市高三化学上学期第二次月考试卷答案及解析
- 物联网感知设备集成-洞察及研究
- 移动远程会诊质量控制研究-洞察及研究
- 生物技术在文物保护中的应用-洞察及研究
- 人工智能算法在农药残留检测中的辅助作用-洞察及研究
- 2025银行统计试题及答案
- 2025士兵体能考试题库及答案
- 2025年职业病诊断医师资格考试复习卷及答案
- 端子拉力测试标准
- 粮食购销结算管理制度
- T/CCAS 010-2019水泥窑协同处置飞灰预处理产品水洗氯化物
- DB37-T1317-2025超细干粉灭火系统技术规范
- 麻醉器械耗材管理制度
- 2025-2030中国AI芯片行业研发创新与未来发展预测分析研究报告
- T-CPI 11037-2024 石油天然气钻采设备水力振荡器技术与应用规范
- 中级审计理论与实务知识导图
- 中介招聘合同范例
- 《流量计培训》课件
评论
0/150
提交评论