




已阅读5页,还剩5页未读, 继续免费阅读
版权说明:本文档由用户提供并上传,收益归属内容提供方,若内容存在侵权,请进行举报或认领
文档简介
附录二:英文原文electric power distributionan electric power distribution system is the final stage in the delivery of electric power; it carries electricity from the transmission system to individual consumers. distribution substations connect to the transmission system and lower the transmission voltage to medium voltage ranging between 2kv and 35kv with the use of transformers. primary distribution lines carry this medium voltage power to distribution transformers located near the customers premises. distribution transformers again lower the voltage to the utilization voltage of household appliances and typically feed several customers through secondary distribution lines at this voltage. commercial and residential customers are connected to the secondary distribution lines through service drops. customers demanding a much larger amount of power may be connected directly to the primary distribution level or the sub transmission level.historyfurther information: history of electric power transmissionelectric power distribution only became necessary in the 1880s when electricity started being generated at power stations. before that electricity was usually generated where it was used. the first power distribution systems installed in european and us cites were used to supply lighting: arc lighting running on very high voltage (usually higher than 3000 volt) alternating current (ac) or direct current (dc), and incandescent lighting running on low voltage (100 volt) direct current. both were supplanting gas lighting systems, with arc lighting taking over large area/street lighting, and incandescent lighting replacing gas for business and residential lighting.due to the high voltages used in arc lighting, a single generating station could supply a long string of lights, up to 7-mile (11 km) long circuits, since the capacity of a wire is proportional to the square of the current traveling on it, each doubling of the voltage would allow the same size cable to transmit the same amount of power four times the distance. direct current indoor incandescent lighting systems (for example the first edison pearl street station installed in 1882), had difficulty supplying customers more than a mile away due to the low 110 volt system being used throughout the system, from the generators to the final use. the edison dc system needed thick copper conductor cables, and the generating plants needed to be within about 1.5 miles (2.4 km) of the farthest customer to avoid excessively large and expensive conductors.introduction of the ac transformertrying to deliver electricity long distance at high voltage and then reducing it to a fractional voltage for indoor lighting became a recognized engineering roadblock to electric power distribution with many, not very satisfactory, solutions tested by lighting companies. the mid-1880s saw a breakthrough with the development of functional ac transformers that allowed the voltage to be stepped up to much higher transmission voltages and then dropped down to a lower end user voltage. with much cheaper transmission costs and the greater economies of scale of having large generating plants supply whole cities and regions, the use of ac spread rapidly.in the us the competition between direct current and alternating current took a personal turn in the late 1880s in the form of a war of currents when thomas edison started attacking george westinghouse and his development of the first us ac transformer systems, pointing out all the deaths caused by high voltage ac systems over the years and claiming any ac system was inherently dangerous. edisons propaganda campaign was short lived with his company switching over to ac in 1892.ac became the dominant form of transmission of power with innovations in europe and the us in electric motor designs and the development of engineered universal systems allowing the large number of legacy systems to be connected to large ac grids.in the first half of the 20th century, the electric power industry was vertically integrated, meaning they one company did generation, transmission, distribution, and metering and billing. starting in the 1970s and 1980s nations began the process of deregulation and privatisation, leading to electricity markets. the distribution system would remain regulated, but generation, retail, and sometimes transmission systems were transformed into competitive marketsgeneration and transmissionelectric power begins at a generating station, where the potential difference can be as high as 13,800 volts. ac is usually used. users of large amounts of dc power such as some railway electrification systems, telephone exchanges and industrial processes such as aluminium smelting usually either operate their own or have adjacent dedicated generating equipment, or use rectifiers to derive dc from the public ac supply. however, high-voltage dc can be advantageous for isolating alternating-current systems or controlling the quantity of electricity transmitted. for example, hydro-quebec has a direct-current line which goes from the james bay region to boston.from the generating station it goes to the generating stations switch yard where a step-up transformer increases the voltage to a level suitable for transmission, from 44,000 to 765,000 volts. once in the transmission system, electricity from each generating station is combined with electricity produced elsewhere. electricity is consumed as soon as it is produced. it is transmitted at a very high speed, close to the speed of light.distribution overviewthe transition from transmission to distribution happens in a power substation, which has the following functions:circuit breakers and switches enable the substation to be disconnected from the transmission grid or for distribution lines to be disconnected.transformers step down transmission voltages, 35kv or more, down to primary distribution voltages. these are medium voltage circuits, usually 600-35,000 v.from the transformer, power goes to the busbar that can split the distribution power off in multiple directions. the bus distributes power to distribution lines, which fan out to customers.urban distribution is mainly underground, sometimes in common utility ducts. rural distribution is mostly above ground with utility poles, and suburban distribution is a mix. closer to the customer, a distribution transformer steps the primary distribution power down to a low-voltage secondary circuit, usually 120 or 240v, depending on the region. the power comes to the customer via a service drop and an electricity meter. the final circuit in an urban system may be less than 50 feet, but may be over 300 feet for a rural customer.primary distributionprimary distribution voltages are 22kv or 11kv. only large consumers are fed directly from distribution voltages; most utility customers are connected to a transformer, which reduces the distribution voltage to the low voltage used by lighting and interior wiring systems.voltage varies according to its role in the supply and distribution system. according to international standards, there are initially two voltage groups: low voltage (lv): up to and including 1,000 v ac (or 1,500 v dc) and high voltage (hv): above 1kv ac (or 1.5kv dc).network configurationsdistribution networks are divided into two types, radial or network. a radial system is arranged like a tree where each customer has one source of supply. a network system has multiple sources of supply operating in parallel. spot networks are used for concentrated loads. radial systems are commonly used in rural or suburban areas.radial systems usually include emergency connections where the system can be reconfigured in case of problems, such as a fault or required replacement. this can be done by opening and closing switches. it may be acceptable to close a loop for a short time.long feeders experience voltage drop (power factor distortion) requiring capacitors to be installed.reconfiguration, by exchanging the functional links between the elements of the system, represents one of the most important measures which can improve the operational performance of a distribution system. the problem of optimization through the reconfiguration of a power distribution system, in terms of its definition, is a historical single objective problem with constraints. since 1975, when merlin and back introduced the idea of distribution system reconfiguration for active power loss reduction, until nowadays, a lot of researchers have proposed diverse methods and algorithms to solve the reconfiguration problem as a single objective problem. some authors have proposed pareto optimality based approaches (including active power losses and reliability indices as objectives). for this purpose, different artificial intelligence based methods have been used: microgenetic, branch exchange, particle swarm optimization and non-dominated sorting genetic algorithm.rural servicesrural electrification systems tend to use higher distribution voltages because of the longer distances covered by distribution lines (see rural electrification administration). 7.2, 12.47, 25, and 34.5kv distribution is common in the united states; 11kv and 33kv are common in the uk, australia and new zealand; 11kv and 22 kv are common in south africa. other voltages are occasionally used. distribution in rural areas may be only single-phase if it is not economical to install three-phase power for relatively few and small customers.rural services normally try to minimize the number of poles and wires. single-wire earth return (swer) is the least expensive, with one wire. it uses higher voltages (than urban distribution), which in turn permits use of galvanized steel wire. the strong steel wire allows for less expensive wide pole spacing. in rural areas a pole-mount transformer may serve only one customer.higher voltage split-phase or three phase service, at a higher infrastructure and a higher cost, provide increased equipment efficiency and lower energy cost for large agricultural facilities, petroleum pumping facilities, or water plants.in new zealand, australia, saskatchewan, canada, and south africa, single wire earth return systems (swer) are used to electrify remote rural areas.secondary distributionelectricity is delivered at a frequency of either 50 or 60 hz, depending on the region. it is delivered to domestic customers as single-phase electric power. seen in an oscilloscope, the domestic power supply in north america would look like a sine wave, oscillating between -170 volts and 170 volts, giving an effective voltage of 120 volts. three-phase power is more efficient in terms of power delivered per cable used, and is more suited to running large electric motors. some large european appliances may be powered by three-phase power, such as electric stoves and clothes dryers.a ground connection is normally provided for the customers system as well as for the equipment owned by the utility. the purpose of connecting the customers system to ground is to limit the voltage that may develop if high voltage conductors fall down onto lower-voltage conductors which are usually mounted lower to the ground, or if a failure occurs within a distribution transformer. earthing systems can be tt, tn-s, tn-c-s or tn-c.regional variations220-240 volt systemsmost of the world uses 50 hz single-phase 220 or 230 v residential and light industrial service. in this system, the primary distribution network supplies a few substations per area, and the 230 v power from each substation is directly distributed. a live (hot) wire and neutral are connected to the building from one phase of three phase service. single-phase distribution is used where motor loads are light. in europe, electricity is normally distributed for industry and domestic use by the three-phase, four wire system. this gives a three-phase voltage of 400 volts wye service and a single-phase voltage of 230 volts. for industrial customers, 3-phase 690 / 400 volt is also available. large industrial customers have their own transformers with an input from 10kv to 220kv. in the uk a typical urban or suburban low-voltage substation would normally be rated between 315kva and 1mva and supply a whole neighborhood.110-120 volt systemsmost of the americas use 60 hz ac, the 120/240 volt split phase system domestically and three phase for larger installations. compared to european systems, north american ones have more step-down transformers near customers. this is because the higher domestic voltage used in europe (230 v vs 120 v) may be carried over a greater distance with acceptable power loss.in the electricity sector in japan, the standard frequencies for ac are 50 and 60 hz. in japan parts of the country use 50 hz, while other parts use 60 hz. this is a relic of the 1800s. some local providers in tokyo imported 50 hz german equipment, while the local power providers in osaka brought in 60 hz generators from the united states. the grids grew until eventually the entire country was wired. today the frequency is 50 hz in eastern japan (including tokyo, yokohama, tohoku, and hokkaido) and 60 hertz in western japan (including nagoya, osaka, kyoto, hiroshima, shikoku, and kyushu).most household appliances are made to work on either frequency. the problem of incompatibility came into the public eye when the 2011 thoku earthquake and tsunami knocked out about a third of the easts capacity, and power in the west couldnt be fully shared with the east, since the country does not have a common frequency.there are four converter stations that move power across japans ac frequency border. shin shinano is a back-to-back hvdc facility in japan which forms one of four frequency changer stations that link japans western and eastern power grids. the other three are at higashi-shimizu, minami-fukumitsu and sakuma dam. together they can move up to 1.2 gw of power east or west.原文出处:/wiki/electric_power_distributionthree-phase electric powerthree-phase electric power is a common method of alternating-current electric power generation, transmission, and distribution.it is a type of polyphase system and is the most common method used by electrical grids worldwide to transfer power. it is also used to power large motors and other heavy loads. a three-phase system is usually more economical than an equivalent single-phase at the same line to ground voltage because it uses less conductor material to transmit electrical power. the three-phase system was independently invented by galileo ferraris, mikhail dolivo-dobrovolsky, jonas wenstrm and nikola tesla in the late 1880s.principlein a symmetric three-phase power supply system, three conductors each carry an alternating current of the same frequency and voltage amplitude relative to a common reference but with a phase difference of one third the period. the common reference is usually connected to ground and often to a current-carrying conductor called the neutral. due to the phase difference, the voltage on any conductor reaches its peak at one third of a cycle after one of the other conductors and one third of a cycle before the remaining conductor. this phase delay gives constant power transfer to a balanced linear load. it also makes it possible to produce a rotating magnetic field in an electric motor and generate other phase arrangements using transformers (for instance, a two phase system using a scott-t transformer).the symmetric threephase systems described here are simply referred to as threephase systems because, although it is possible to design and implement asymmetric threephase power systems (i.e., with unequal voltages or phase shifts), they are not used in practice because they lack the most important advantages of symmetric systems.in a threephase system feeding a balanced and linear load, the sum of the instantaneous currents of the three conductors is zero. in other words, the current in each conductor is equal in magnitude to, but with the opposite sign of, the sum of the currents in the other two. the return path for the current in any phase conductor is the other two phase conductors.compared to a single-phase ac power supply that uses two conductors (phase and neutral), a three-phase supply with no neutral, the same phase-to-ground voltage and current capacity per phase can transmit three times as much power using just 1.5 times as many wires (i.e., three instead of two). thus, the ratio of capacity to conductor material is doubled. the same (but not the other properties of three-phase power) can also be attained with a center-grounded single-phase system.three-phase systems may also utilize a fourth wire, particularly in low-voltage distribution. this is the neutral wire. the neutral allows three separate single-phase supplies to be provided at a constant voltage and is commonly used for supplying groups of domestic properties which are each single-phase loads. the connections are arranged so that, as far as possi
温馨提示
- 1. 本站所有资源如无特殊说明,都需要本地电脑安装OFFICE2007和PDF阅读器。图纸软件为CAD,CAXA,PROE,UG,SolidWorks等.压缩文件请下载最新的WinRAR软件解压。
- 2. 本站的文档不包含任何第三方提供的附件图纸等,如果需要附件,请联系上传者。文件的所有权益归上传用户所有。
- 3. 本站RAR压缩包中若带图纸,网页内容里面会有图纸预览,若没有图纸预览就没有图纸。
- 4. 未经权益所有人同意不得将文件中的内容挪作商业或盈利用途。
- 5. 人人文库网仅提供信息存储空间,仅对用户上传内容的表现方式做保护处理,对用户上传分享的文档内容本身不做任何修改或编辑,并不能对任何下载内容负责。
- 6. 下载文件中如有侵权或不适当内容,请与我们联系,我们立即纠正。
- 7. 本站不保证下载资源的准确性、安全性和完整性, 同时也不承担用户因使用这些下载资源对自己和他人造成任何形式的伤害或损失。
最新文档
- 哈尔滨市中储粮2025秋招面试半结构化模拟题30问及答案
- 中国移动宝鸡市2025秋招技术岗专业追问清单及参考回答
- 国家能源烟台市2025秋招面试专业追问及参考能源与动力工程岗位
- 昌都市中储粮2025秋招面试专业追问题库财务资产岗
- 中国移动宜昌市2025秋招计算机类专业追问清单及参考回答
- 宁德市中储粮2025秋招写作案例分析万能模板直接套用
- 银川市中储粮2025秋招面试专业追问题库质检化验岗
- 中国广电济宁市2025秋招计算机类专业追问清单及参考回答
- 乌海市中石油2025秋招笔试模拟题含答案法律与合规岗
- 朔州市中石油2025秋招笔试综合知识专练题库及答案
- 2024版2025秋贵州黔教版综合实践活动五年级上册全册教案教学设计
- 转作风重实干课件
- 甲状腺课件类型
- 单招备考科学方案
- 2025年秋新人教版数学三年级上册全册教学课件
- 医美咨询培训课件
- NoSQL数据库应用与实践 课件 第1-6章 认识NoSQL - 增删改查
- DB37-T4868-2025 既有公路隧道结构健康监测技术规范
- 供应链金融视角下涉农中小企业信用风险评估研究
- 宁夏差旅费管理办法文件
- DB51∕T 3231-2024 公路隧道岩爆防控技术规程
评论
0/150
提交评论