Froet Industries, LLCApril 2011PO Box 7871741 Industrial DriveSterling, Illinois 61081Phone815-626-7922Fax815-626-0702WE-Product Guide SpecificationSpecifier Notes: This product guide specification is written according to the Construction Specifications Institute (CSI) 3-Part Format, including MasterFormat, SectionFormat, and PageFormat, as described in The Project Resource ManualCSI Manual of Practice, Fifth Edition.This section must be carefully reviewed and edited by the Architect or Engineer to meet the requirements of the project and local building code. Coordinate this section with other specification sections and the Drawings. Delete all “Specifier Notes” after editing this section.Section numbers and titles are from MasterFormat 2010 Update.SECTION 22 05 19ROOF DRAINAGE SYSTEM FLOW SENSORSSpecifier Notes: This section covers Froet Industries, LLC “6000 Series” and “7000 Series” roof drainage system flow sensors. Consult Froet Industries, LLC for assistance in editing this section for the specific application.PART 1 GENERAL1.1 SECTION INCLUDESSpecifier Notes: Specify one of the following four sentences.A. Roof drainage system flow sensors.B. Rainwater harvesting system flow sensors.C. Roof water level monitor.D. Backwater preventer relief valve monitor.1.2 RELATED REQUIREMENTSSpecifier Notes: Edit the following list of related sections as necessary. Limit the list to sections with specific information that the reader might expect to find in this section, but is specified elsewhere.A. Section 22 14 13 Facility Storm Drainage Piping.B. Section 22 14 26.13 Roof Drains.Specifier Notes: Include the following related section if flow sensors are connected to a building management system. Provide section number and title.C. Section _ _: Building management system.1.3 SUBMITTALSSpecifier Notes: Edit submittal requirements as necessary. Delete submittals not required.A. Comply with Section 01 33 00 Submittal Procedures.B. Product Data: Submit manufacturers product data, including installation instructions.C. Shop Drawings: Submit manufacturers shop drawings, including plans, elevations, sections, and details, indicating dimensions, tolerances, materials, components, hardware, electrical wiring diagrams, options, and accessories.D. Manufacturers Certification: Submit manufacturers certification that materials comply with specified requirements and are suitable for intended application.E. Operation and Maintenance Data:1. Submit manufacturers operation and maintenance manual; including the following:a. Operation.b. Maintenance, if battery back-up installed.c. Electrical wiring diagrams.2. Provide detailed information required for Owner to properly operate and maintain equipment.F. Warranty Documentation: Submit manufacturers standard warranty.1.4 DELIVERY, STORAGE, AND HANDLINGA. Delivery and Acceptance Requirements: Deliver materials to site in manufacturers original, unopened containers and packaging, with labels clearly identifying product name and manufacturer.B. Storage and Handling Requirements:1. Store and handle materials in accordance with manufacturers instructions.2. Keep materials in manufacturers original, unopened containers and packaging until installation.3. Store materials in clean, dry area indoors.4. Protect materials during storage, handling, and installation to prevent damage.PART 2 PRODUCTS2.1 MANUFACTURERA. Froet Industries, LLC, PO Box 787, 1741 Industrial Drive, Sterling, Illinois 61081. Phone 815-626-7922. Fax 815-626-0702. . .2.2 ROOF DRAINAGE SYSTEM FLOW SENSORSSpecifier Notes: Specify Froet “6000 Series” or “7000 Series” flow sensors.A. Flow Sensors: Froet “6000 Series” flow sensors.Specifier Notes: Specify one of the following two Froet “6000 Series” flow sensor models. “Five Unit Sensor” model includes building management system connections.1. Model: “Single Unit Sensor Economy” “Five Unit Sensor” with building management system connections.2. Description:a. Provides notification of overflow situation on flat building roof due to blockage of primary roof drainage system or inability of primary system to adequately handle water load on roof.b. Use with properly designed and maintained roof drainage system, where overflow system flows water only in rare occasions due to blockage or excessive rainfall.c. Monitors 1 overflow roof drain per sensor.d. Provides alerts for both low and high flow conditions.e. Registered flow level remains present until manually cleared.3. Pipe Line Size: 2 inches thru 12 inches.4. Pipe Material: PVC, steel, or cast iron.5. Sensor Pickup:a. Material: Stainless steel.b. Supplied in 6-inch-long section of PVC or cast iron pipe.c. Installed by no-hub gaskets or gluing PVC section into horizontal run of overflow drainage line.6. Pickup Signal: 12 volts.7. Supply Power: 120 VAC transformer reduced to 12 VDC, UL Listed.Specifier Notes: Include the following sentence when specifying “Five Unit Sensor” model.8. Output:a. Dry contact switch for building management system.b. Signal: Closed.B. Flow Sensors: Froet “7000 Series” flow sensors.Specifier Notes: Specify one of the following two current and voltage output control modules.1. Current and Voltage Output Control Module: Single channel 5 channel.2. Description:Specifier Notes: Edit the following description of the flow sensors for the specific application. Delete sentences not required.a. Provides notification to building management system of overflow situation on flat building roof due to blockage of primary roof drainage system or inability of primary system to adequately handle water load on roof.b. Use with properly designed and maintained roof drainage system, where overflow system flows water only in rare occasions due to blockage or excessive rainfall.c. Monitors 1 overflow roof drain per sensor channel.d. Provides alerts for both low and high flow conditions.e. Provides monitoring of roof water level thru use of wall-mount weathertight junction box.f. Provides monitoring of relief valves of backwater preventers and sends signal to valve actuator to stop water flow.g. Registered flow level remains present until manually cleared.Specifier Notes: Include the following sentence if the flow sensor is used in a rainwater harvesting system. Delete if not required.3. Rainwater Harvesting System: Use to sense water in rainwater harvesting system and control a valve to flush debris in first 10 minutes of rain and fill storage tank.a. 10-Minute Delay Module: Delays signal for rainwater harvesting.4. Pipe Line Size: 2 inches thru 12 inches.5. Pipe Material: PVC, steel, cast iron, or copper.6. Sensor Pickup:a. Material: Stainless steel.b. Supplied in 6-inch-long section of PVC, steel, cast iron, or copper pipe.c. Installed by no-hub gaskets or gluing PVC section into horizontal run of overflow drainage line.7. Signal sent out to pickup and back to control unit via low-voltage 12 V signal.8. Outputs: Current or voltage outputs to provide for connection to building management system or to control valve actuators.9. Sensor Inputs:a. Common: Connection required for minimum or maximum inputs.b. Minimum: Connection as needed for application.c. Maximum: Connection as needed for application.10. Unit Outputs:a. Current Loop Output (“CUR”):1) Level detection OFF.2) Neither low “MIN” nor high “MAX” level condition detected.3) Output: 3 mA, plus or minus 0.3 mA.b. Current Loop Output (“CUR”):1) Level detection ON.2) Low “MIN” or high “MAX” level condition detected.3) Output: 20 mA, plus or minus 2 mA.c. Current Loop Fault Condition Detected:1) Open circuit in loop.2) Output: 0 mA.d. Voltage Level Output (“VLT”):1) Level detection OFF.2) Neither low “MIN” nor high “MAX” level condition detected.3) Output: 0 V, referenced to common ground.e. Voltage Level Output (“VLT”):1) Level detection ON.2) Neither low “MIN” nor high “MAX” level condition detected.3) Output: 10 V, plus or minus 1 V.11. Alarms:a. Low Level “MIN”: Yellow LED turns ON.b. High Level “MAX”:1) Red LED turns ON.2) 2.5 kHz (nominal) audible alert turns ON.12. Controls Front Panel:a. Reset (Alarm) Switch: Resets alarms to OFF state if alarm conditions no longer exist.b. Alarm Silence Switch: Silences audible alarm when high level alarm conditions exist.13. Control Internal:Specifier Notes: 3-hour timer reset board is optional. Delete if not required.This is used with rainwater harvesting to reset system to flush at next rain event. It is a global reset, so if the 5 unit was used for rainwater harvesting and overflow monitoring, a building management system would be needed to record overflow event. It can also be used in overflow monitoring, if the building management system is recording event and they want it to auto reset.a. 3-Hour Timer Reset Board: Automatically resets High Alarms after 3 hours, plus or minus 10 percent.14. Control External:a. External Reset-Terminal Block Receptacle: Install external switch or dry-contact relay closure for external means of resetting alarms.Specifier Notes: Internal battery back-up is optional. Delete if not required.15. Internal Battery Back-up:a. 12 volts, 0.8 amp-hrs.b. Operating Temperature Range: Minus 4 to 122 degrees F (minus 20 to 50 degrees C).c. Recommended Life: 3 to 5 years.d. UL recognized.e. Provides continued functionality if AC power is out, up to approximately 24 hours for single-channel alarm set.16. Power Indicators Front Panel:a. AC On: When lit, indicates AC power source (use power supply supplied or equivalent 12 VDC, 500 mA supply) is supplying power to unit.b. DC On:1) LED (AC): Lit when AC power source is supplying power to unit.2) LED (DC): Lit when internal battery back-up is connected and charged.17. Power Input:a. 120 VAC, 60 Hz linear power supply with 12 VDC, 500 mA output.b. UL listed.PART 3 EXECUTION3.1 EXAMINATIONA. Examine piping to receive flow sensors.B. Notify Architect of conditions that would adversely affect installation or subsequent use.C. Do not begin installation until unacceptable conditi
温馨提示
- 1. 本站所有资源如无特殊说明,都需要本地电脑安装OFFICE2007和PDF阅读器。图纸软件为CAD,CAXA,PROE,UG,SolidWorks等.压缩文件请下载最新的WinRAR软件解压。
- 2. 本站的文档不包含任何第三方提供的附件图纸等,如果需要附件,请联系上传者。文件的所有权益归上传用户所有。
- 3. 本站RAR压缩包中若带图纸,网页内容里面会有图纸预览,若没有图纸预览就没有图纸。
- 4. 未经权益所有人同意不得将文件中的内容挪作商业或盈利用途。
- 5. 人人文库网仅提供信息存储空间,仅对用户上传内容的表现方式做保护处理,对用户上传分享的文档内容本身不做任何修改或编辑,并不能对任何下载内容负责。
- 6. 下载文件中如有侵权或不适当内容,请与我们联系,我们立即纠正。
- 7. 本站不保证下载资源的准确性、安全性和完整性, 同时也不承担用户因使用这些下载资源对自己和他人造成任何形式的伤害或损失。
最新文档
- GB/T 15473-2025核电厂安全级静止式蓄电池充电器、逆变器和不间断电源系统的鉴定
- 森林灭火知识培训方案课件
- 森林消防装备维护保养课件
- 4.3.2发生在肺内的气体交换 解码呼吸的“动力之源”肺与外界的气体交换课件(内嵌视频)人教版(2024)七年级生物下册
- 桥梁知识培训资料课件
- 2025年高校化学实验岗位招聘考试备考策略与热点解析
- 2025年注册验船师资格考试(B级练习题)能力提高训练题及答案一
- 2025年茶艺师初级笔试核心考点复习
- 2025年财务管理岗位招聘面试宝典预测题解析与实战案例
- 2025年公务员行政职业能力测试全真模拟卷
- 园区光纤施工方案
- 技师、高级技师职业资格鉴定申请表
- 人格障碍教学课件-人格障碍
- 高中开学军训期间主题班会课件《高一新生入学目标与纪律管理主题班会》
- 小学六年级美术《木版画》课件
- 检验指导书SIP样板
- 广西壮族自治区瑶药材质量标准第一卷
- GB 35574-2017热电联产单位产品能源消耗限额
- 催化重整装置大赛题库(技师、高级技师)
- 意外伤害急救常识及绷带包扎法课件
- 硫酸法钛白生产工艺操作规程
评论
0/150
提交评论