Automobile Industry Standard of the Peoples Republic of ChinaTechnical Specifications for Hydraulic Brake Wheel Cylinder of CarsQC/T.77-93 substitute JB 540-641. Subject content and scope of application This standard specifies product categories, technical requirements, test procedures, inspection rules as well as labeling, packaging, transportation and storage for automotive hydraulic drum brake wheel cylinder assemblies. This standard applies to the automotive hydraulic drum brake wheel cylinder assemblies using non-petroleum base brake fluid (hereinafter referred to as “wheel cylinder”, see Fig. 1 and Fig. 2). 2. Reference standards JB 2759General Technical Specifications for Packaging of Electromechanical Products GB 2828In-batch Check Counting Sampling Process and Sample Table GB 10830Specifications of Using Motor Vehicle Brake Fluid GB 7524Hydraulic Brake Rubber Cups for Automobiles GB 1801Tolerance and Fitting, Dimensions up to 500 mm Holes, Shaft Tolerance Range and Fitting GB 1030Surface Roughness-Parameters and Their Values3 Product categories3.1 The products are divided into three categories by working conditions (see Table 1). Table 1 Categories of Wheel Cylinders by Working ConditionsCategoryWorking conditionsClass 1Use under general conditions (-4070)Class 2Use under high temperature conditions (-40120)Class 3Use under special conditions (-40150)3.2 They are divided into four pressure ratings by maximum working hydraulic pressures: 10Mpa, 15Mpa, 20Mpa and 25Mpa. 3.3 According to the wheel cylinder bore D0 specified in B2 of Table B of Appendix B in GB 7524, they can also be divided into 21 dimension series. 4 Technical Requirenments4.1 The wheel cylinder should be manufactured per the pattern and documents approved according to an established procedure and conform to the requirements of this standard.Table 2 Dimensional Tolerances of Cylinder Block BoresDiameter of wheel cylinder bore D029mmH9Diameter of wheel cylinder bore D029mmH84.2 Major parts4.2.1 The dimensional tolerance of the cylinder block bore should conform to the specifications in GB 1801 and be selected per Table 2 except special cases. The roughness of the cylinder block inner surface should conform to the specifications in GB 103l (Ra0.4). 4.2.2 The piston cup should meet the specifications in GB 7524. 4.3 Requirements to overall performance4.5.1 Performance under normal temperature4.5.1.1 Sliding resistance Test in accordance with the specifications in Article 7.1.2.1. The air pressure when the piston starts its fifth move should not exceed 0.1Mpa. The piston should reciprocate smoothly without leakage. When the bleeder screw is unscrewed, gas should be bled. 4.5.1.2 Low pressure sealing performance After the test in accordance with the specifications in Article 7.1.2.2.2, the hydraulic pressure drop should not exceed 7Kpa. Fig. 1 One-Way Wheel Cylinder Assembly 1 Cylinder block; 2 Piston; 3 Cup; 4 Dust boot; 5 Regulating wheel; 6 Adjusting screw; 7 Locking spring of regulating wheel; 8 Screw; 9 Spring washer; 10 Bleeder screw; 11 Bleeder screw cap; 12 Choke plug Fig. 2 Two-Way Wheel Cylinder Assembly 1 Cylinder block; 2 Piston; 3 Cup; 4 Dust boot; 5 Bleeder screw; 6 Bleeder screw cap; 7 Choke plug4.3.1.3 High pressure sealing performance After the test in accordance with the specifications in Article 7.1.2.3, the hydraulic pressure drop should not exceed 0.3Kpa. 4.5.1.4 Pressure withstanding capability After the test in accordance with the specifications in Article 7.1.2.4, there should be no leakage and abnormal situations. 4.5.2 Performance under low temperature4.5.2.1 Test in accordance with the specifications in Article 7.2.2 during which there should be no leakage and abnormal situations. 4.3.2.2 Check for sealing performance in accordance with the specifications in Article 7.2.3 and the result should meet the requirements in Articles 4.3.1.2 and 4.3.1.3. 4.3.3 Durability under high temperature4.3.3.1 Test in accordance with the specifications in Article 7.3.2 during which there should be no leakage and the piston should move smartly without any abnormal situations. 4.5.5.2 Check for sealing performance in accordance with the specifications in Article 7.3.3 and the result should meet the requirements in Articles 4.3.1.2 and 4.3.1.3. 4.3.4 Corrosion resistance during storage4.3.4.1 See Article 7.4.2 for the specifications on the test procedure. After a 12-cycle test, take out the sample assembly and then push the wheel cylinder piston to reach its maximum stroke repeatedly to see if it can move smartly. 4.3.4.2 Disassemble the wheel cylinder and then observe its inwall under bright light beam after cleaning. There should be no visible corrosion and serious partial wear, but local discoloration that will not affect surface roughness is permitted. 4.3.5 Resistance to flooding After the test in accordance with the specifications in Article 7.5, there should be no water immersion at inside of the dust boot.5 Test apparatuses The test apparatuses are shown in Fig. 3, Fig. 4 and Fig. 5. 5.1 Stroke device The stroke device can be mechanical, pneumatic or hydraulic type and it could push the master cylinder both in one go and periodically. When it pushes the master cylinder in one go, 130% working hydraulic pressure can be built up in the hydraulic system and the piston can be kept at different stroke positions. When it pushes the master cylinder periodically, the frequency will be 2.7810-1Hz (1000100 times/h). 5.2 Wheel cylinder fixture As shown in Fig. 4, the wheel cylinder fixture applies to installation of both one-way and two-way wheel cylinders. The shape of the in-piston end of the push rod should be the same as that of corresponding part in the brake assembly so as to ensure a proper fit between them. The included angle between the push rod and the wheel cylinder axis should not be greater than 4. The wheel cylinder fixture should ensure that the stroke of the wheel cylinder piston is 4.80.5mm. A hydraulic pressure should be built up in the wheel cylinder and should change per the curve in Fig. 6. 5.3 Test apparatus for resistance to flooding The test apparatus for resistance to flooding is shown in Fig. 5.6. Test requirements6.1 The test sample should meet the technical specifications of the maker. Three or more pieces of samples are required for each test. Unless specially specified otherwise, the assembly can be disassembled only after finish of the test. 6.2 The brake fluid used for the test should be non-petroleum base type and should meet the requirements in GB 10830. The specific brand can be determined by the supplier and the purchaser through negotiation. 6.3 During the high or low temperature performance test, remove the dust boot and then perform the test items in the sequence specified. Each wheel cylinder must go through the whole test process. 6.4 All tests except the sliding resistance test and the in-storage corrosion resistance test should be conducted with the wheel cylinder fixed on the wheel cylinder fixture. 7 Test Process7.1 Normal temperature performance test7.1.1 Test conditionsa. The precision of the pressure gauge should not be below 0.4 grade; b. The ambient temperature is within 1032. 7.1.2 Test procedures7.1.2.1 Sliding resistance test Block the drain hole (or air bleed hole) on the wheel cylinder and introduce an air pressure (0.1Mpa) through the inlet hole. Then, observe acting mobility of piston and see if gas will be bled when the bleeder screw is unscrewed. 7.1.2.2 Low pressure sealing performance test Connect the inlet hole on the wheel cylinder with the drain hole on the master cylinder, fill the brake fluid, bleed the entrained air in the system completely, push the master cylinder piston to build up a hydraulic pressure of 140 7kPa in the hydraulic system, and keep position of the push rod unchanged. Then, record the hydraulic pressure drop in 30s after the pressure becomes stable. 7.1.2.5 High pressure sealing performance test Push the master cylinder piston to build up the maximum working hydraulic pressure in the hydraulic system, keep position of the push rod unchanged after the pressure becomes stable, and then record the hydraulic pressure drop in 30s. 7.1.2.4 Pressure withstanding capability test Push the master cylinder piston slowly to build up 130% maximum working hydraulic pressure in the hydraulic system in 155s and keep position of the push rod unchanged. Then, record the hydraulic pressure drop in 5s after the pressure becomes stable. 7.2 Low temperature performance test See Fig. 3 for the test apparatus.Counter:Thermostat ContainerRecording unitPressure sensorSwitch valveWheel cylinder fixture Stroke device:MechanicalPneumatic or hydraulic frequency2.7810-1Hz(1000100 times)Stroke devicePower unitFluid storage chamberPush rodMaster cylinderSwitch valvePressure gaugeFig. 3 Test Apparatuses for High and Low Temperature Performance TestsWheel cylinderFig. 4 Wheel Cylinder Fixture Wheel cylinderWheelcylinder fixtureWater tankCounterStroke device:Push rodMaster cylinderSwitch valveFluid storage chamberFig. 5 Flooding Resistance TestPiston stroke (mm)Hydraulic pressureFig. 6 Relation Curves between Piston Stroke and Hydraulic Pressure7.2.1 Test conditions a. The precision of the standard pressure gauge is 0.4 grade (range: 016 Mpa); b. Ambient temperature: -405. 7.2.2 Test procedures Fill the wheel cylinder and the fluid storage chamber with brake fluid as specified, bleed the entrained air in the system completely, and then place filter papers under the wheel cylinder after making sure that there is no leakage. The duration of the whole test is 1202h. Build up a hydraulic pressure of 0.700.2 Mpa at 72h, 96h and 120h respectively with temperature kept at -405 and displacement of the piston not restricted. Subsequently, give the master cylinder piston another six pushes to build up a hydraulic pressure of 3.5Mpa in the hydraulic system with a push interval of 1 min, during which observe acting mobility of the piston and check for leakage. 7.2.3 Sealing performance inspection 7.2.2 After finish of the test, repeat the tests in Articles 7.1.2.2 and 7.1.2.3 under low temperature conditions still and set the maximum hydraulic pressure for the test in Article 7.1.2.3 to 7.0 0.3 Mpa. If restricted by conditions, you can switch to room temperature to conduct the test above within 5 min. 7.3 High temperature durability test See Fig. 3 for the test apparatus. Stroke device: enable the wheel cylinder piston to reciprocate with a frequency of 2.7810-1HZ (1000100 times/h). 7.3.1 Test conditions See Table 3 for the test conditions. Determine the relation curves between the piston stroke and the hydraulic pressure according to Table 3. 7.3.2 Test procedures Fill the wheel cylinder and the fluid storage chamber with brake fluid as specified, bleed the entrained air in the system completely, and then place filter papers under the wheel cylinder after making sure that there is no leakage. Start the test and observe for leakage every 2h during the test process.7.3.3 Sealing performance inspection 7.3.2 After finish of the test, repeat the tests in Articles 7.1.2.2 and 7.1.2.3 under high temperature conditions still and set the maximum hydraulic pressure for the test in Article 7.1.2.3 to 7.0 0.3 Mpa. If restricted by conditions, you can switch to room temperature to conduct the test above within 5 min. Table 3 Conditions of High Temperature Durability TestItemClass 1Class 2Class 3Brake fluid used for the testSee Article 6.2Temperature in constant temperature cabinet 70112021502Piston stroke mm4.80.5 (single side)Duration h1202701Maximum hydraulic pressure Mpa3.50.370.3Relation between piston stroke and hydraulic pressureSet the piston stroke to 4.8 mm, raise the hydraulic pressure to 1.30.3 Mpa and then further to 3.5 0.3 Mpa (see curve A in Fig. 6). Set the piston stroke to 2.4 mm and raise the hydraulic pressure to 0.60 0.15 Mpa; set the piston stroke to 4.8 mm, raise the hydraulic pressure to 5.1 0.5 Mpa and then further to 7 0.3 Mpa. After negotiation between both parties, you can continue to raise the hydraulic pressure to 10 0.5 Mpa (see curve B in Fig. 6).7.4 In-storage corrosion resistance test7.4.1 Test apparatus Constant temperature and humidity cabinet: relative humidity of (953) %; temperatures at 20l and 45l respectively. 7.4.2 Test procedures7.4.2.1 Drain the brake fluid in the wheel cylinder, place the piston to brake released position (without removing the dust boot) and then put it into the constant temperature and humidity cabinet with inlet and outlet holes down. Rest it for 16 1h under 451 with a relative humidity of (95 3)% and another 8 1h under 20 l with the same relative humidity (one cycle, 12 cycles in total).7.4.2.2 Immediately after above test item, push the piston to reach its maximum stroke for not less than 5 times repeatedly, during which observe its acting mobility. 7.4.2.3 Disassemble the wheel cylinder, wipe up all parts of cylinder wall, piston, cup, etc., and then observe for corrosion and other abnormal situations. 7.5 Flooding Resistance test (optional) See Fig. 5 for the test apparatus.7.5.1 The test conditions are specified in Table 4 and Table 5. Table 4 Thermal Deterioration ConditionsCategoryThermal deterioration conditionsTemperature Duration h110057012120531505Table 5 Conditions of Flooding Resistance TestCategoryWater depth (mm)Water temperatureNumber of strokes/time (times/h)Number of actionsStroke (mm)130030Normal temperature10001005002237.5.2 Test procedures Follow the conditions below to conduct the test after installing the dust boot onto the wheel cylinder assembly. a. Install the wheel cylinder assembly onto the wheel cylinder fixture and the place it into the constant temperature cabinet; b. Set the wheel cylinder piston stroke to 4.8 mm at the largest value side and then place it at the position 2 mm back from the maximum stroke; c. Hold the temperature in the constant temperature cabinet as shown in Table 4 and then heat continuously for 70 1h; d. After 70 1h, take out the wheel cylinder fixture and the wheel cylinder assembly and then put them indoors to cool down until room temperature; e. After connecting the wheel cylinder fixture with the power unit, bleed air completely, fill the water tank, and then fix the wheel cylinder fixture until the distance between the center line of the wheel cylinder and the water level is 300 30 mm (see Fig. 5). f. Return the piston 2 mm from the 4.8 mm stroke position and then back again to the 4.8 mm stroke position to test repeatedly in accordance with the specifications in Table 5; g. Take the wheel cylinder assembly out of the water tank and then wipe up the water outside; h. Remove the dust boot to observe soakage status inside it. 8. Inspection rules8.1 All products to be delivered should be tested piece by piece in accordance with Articles 7.1.2.1, 7.1.2.2 and 7.1.2.3 of this standard and the results should meet the performance requirements in Articles 4.3.1.1, 4.3.1.2 and 4.3.1.3 of this standard.8.2 Before delivered, each wheel cylinder assembly must pass the inspection performed by the inspection department of the maker; also, the document of conformity should be attached. 8.3 Reinspection is required regularly for the products in mass and batch production. Test in accordance with the test items and procedures specified in Section 7 of this standard and the test results should meet the requirements in Article 4.3. 8.4 For any products manufactured after finalization of a new product or a significant improvement or transfer production, all test samples should be tested 100% in accordance with the specifications in Section 7

温馨提示

  • 1. 本站所有资源如无特殊说明,都需要本地电脑安装OFFICE2007和PDF阅读器。图纸软件为CAD,CAXA,PROE,UG,SolidWorks等.压缩文件请下载最新的WinRAR软件解压。
  • 2. 本站的文档不包含任何第三方提供的附件图纸等,如果需要附件,请联系上传者。文件的所有权益归上传用户所有。
  • 3. 本站RAR压缩包中若带图纸,网页内容里面会有图纸预览,若没有图纸预览就没有图纸。
  • 4. 未经权益所有人同意不得将文件中的内容挪作商业或盈利用途。
  • 5. 人人文库网仅提供信息存储空间,仅对用户上传内容的表现方式做保护处理,对用户上传分享的文档内容本身不做任何修改或编辑,并不能对任何下载内容负责。
  • 6. 下载文件中如有侵权或不适当内容,请与我们联系,我们立即纠正。
  • 7. 本站不保证下载资源的准确性、安全性和完整性, 同时也不承担用户因使用这些下载资源对自己和他人造成任何形式的伤害或损失。

评论

0/150

提交评论