已阅读5页,还剩84页未读, 继续免费阅读
版权说明:本文档由用户提供并上传,收益归属内容提供方,若内容存在侵权,请进行举报或认领
文档简介
1,ELECTRICALSAFETY电气安全,2,Currentflowthroughthebody电流通过人体,Yourbodyactslikeaconductor.你的身体是一个导体Mostcommonpathusuallyinvolvesheart手至手,背或臀至手比较危险;电流经过大脑时相当危险;脚至脚危险性较小)。由电源线(通常为50赫兹)的交流电从手流到脚1秒钟的触电会产生以下的后果:,TheEffectsOfElectricalShock触电的结果,5,0.71milliamp-(LADY-MEN)barelyperceptible.0.71毫安刚能觉察到(手指麻刺)9-25milliamps-Interruptionofmuscularcontrol.9-25毫安对肌肉的自控中断(手迅速麻痹,呼吸困难)milliamps-interruptionofheartfunction75毫安心脏功能中断(心室开始颤动)amps-Immediatecardiacarrest4安培心博立即停止,TheEffectsOfElectricalShock触电的结果,6,Secondaryinjuriesarefrequentlyassociatedwithelectricalshock.Theseinjuriesarenormallyassociatedwithfallsorcollisionsrelatedtotheelectricalshockcausinginvoluntarymusclereactions.Obviously,inthecaseoffallstheresultcanalsobefatal.电还会经常引发二次伤害。这类伤害通常与因触电引起肌肉不自觉的反射而跌倒或碰撞相关。显然,如果跌倒的话,也会引起伤害甚至死亡。,7,内容综述:Todaystopicsinclude:雷电Lightning电动工具electricalHandTools配线及插座WringLVcables:-0.mminimum.所有电缆宜沿途采用标记Allthecablesshouldbeproperlymarkedalongtherouting.,地下电缆UndergroundCable,43,如果不可避免,电缆与道路的净距为:Ifitisunavoidable,thecleanheightabovetheroadandroutecrossingsare:当道路过车时,6.0米6.0m,wheretheroadsandroutesaredesignatedforusebyvehiculartraffic.当道路禁止车辆通行时,3.5米地上电缆应采取措施固定,并尽可能避开人行道、扶梯、楼梯等Abovegroundcablesshallbefixedonsite,andbeinstalledclearofpassageways,ladders,stairetc.wherepossible.,地上电缆AboveGroundCable,44,地上电缆应缠绕黄/黑色胶带Abovegroundcablesshallbelabeledwithyellow/blackcoloredtapes.与管道设施保持最少150厘米的间距Keepdistancewithpipedservices,ataminimumof150mm.经常移动的电缆应采用重型氯丁橡胶电缆或类似功能电缆Frequentlymovedcablesshallbeflexibleheavy-dutyneoprenerubbertypeorequivalent.,地上电缆AboveGroundCable,45,低压接地系统采用TN-S保护系统.LVsuppliesearthingsystemshallbearrangedasTN-S.接地网电阻不应大于4欧姆。接地线应为标准铜导体黄绿色PVC绝缘,应选用合适规格。Theresistanceofearthinggridshallnotexceed4.Earthwiresshallbeofthestandardcopperconductorwithgreen/yellowPVCsheathing,andproperlysized.,接地/接零保护,46,Transformersubstations所有户外型变电所均应满足户外使用要求Allthesubstationsusedoutdoorshallmeettheoutdooruserequirements.变压器连接组别应为三角形-星形连接,低压中性点应直接接地Transformersshallbeconnecteddelta-starandtheLVneutralpointshallbesolidlyearthed.使用紧凑型变电所时,保证其置于水泥柱基础上并围以带锁的围栏Whenusethepackagedsubstations,makesuretheyaremountedonconcreteplinthswithafencedenclosurewithpadlockablegates.使用角杆保护变电所不受车辆影响,其与路边的距离宜大于5米Thecornerpostsshallprotectthesubstationequipmentfromvehicleimpact.Anditshouldbelocatedatleast5mclearfromtheedgeofanyroad.,变电所,47,Distributionboards(LV)所有户外用配电柜均应满足户外使用要求Allthedistributionboardsusedoutdoorshallmeettheoutdooruserequirements.回路应采用熔断器或塑壳短路器保护,最大不超过355安TheoutgoingcircuitsshallbeprotectedbyfusesorMCCBshavingamaximumratingof355A.分配电盘Forthesub-distributionboard应有进线开关Oneincomingswitchshallbeprovidedwith.所有配出回路均应采用短路及漏电电流保护。最大不超过125安Eachoutgoingfeedershallbeprovidedwithshortcircuitandresidualcurrentprotection.Maximumoutgoingfeederratingshallbe125A.,配电盘(低压),48,系统挂牌、上锁SystemLockout/Tagout,49,系统挂牌、加锁可保护人员、设备在项目建设及起动过程中不受危险能源的危害,并为停用的系统设备及系统提供信息Safetytagsandlockoutswillhelptoprotectpersonnelandequipmentformhazardousenergysourcesduringtheconstructionandstartupphaseoftheproject,andalsoprovideadescriptionoftheequipmentcomponentsandsystemsthatareoutofservice.,目的Purpose,50,Twotypesoftags危险不得操作/移除挂牌Danger-DoNotOperate/RemoveTag禁止人员操作、通电、或加压设备及电气回路prohibitingpersonnelformoperating,energizing,orpressurizingequipmentandelectricalcircuits.,两种挂牌形式,51,注意限制操作挂牌CautionRestrictedOperationTag控制人员操作、通电或加压于设备或电路的方法。controllingthemethodspersonnelmayusetooperate,energizeorpressurizeequipmentandelectricalcircuits.,52,ElectricalLock-Out电的锁定的要求,Intheeventanelectricalsystemisrequiredtobelocked-out,theSupervisoroftheEmployeerequestingthelock-outmustcontacttheappropriateProjectorUnitpersonnel.QualifiedProjectorUnitpersonnelwillassistwithisolationoftheelectricalsystemsneededtoisolatetheelectricalenergysourceby:在电系统要求锁定的情况下,主管人员要求锁定必须与项目或者单位人员进行适当的沟通,项目或单位有资格的人员将帮助隔离电源:Placingalock-outdeviceontheappropriateisolatingdevice.放一个锁定装置在适当的隔离装置上。Placingacompletedtagoneachlock-outdevicehe/sheplaced.在放锁定装置上放一个有效的标签,53,Tryingtooperateequipmentormachinerylocked-outtoassureisolation.试着操作设备或机械确保隔离有效Removelock-outdevicesandtagslast,afterallworkandotherlock-outdevicesandtagshavebeenremoved.在所有工作完成并且其它的锁定和标签已取消后取消锁定和标签。EachSupervisoroftheanydepartmentworkingwiththeelectricallock-outmustensurethelock-outofthesystembytestingstartbuttonsorswitches.每个工作要在电锁定部门的主管要确保锁定系统经过起动试验或开关试验。,ElectricalLock-Out电的锁定的要求,54,ELECTRICALLOCKOUT电气开关锁定,55,注意Requirements加锁是好方法Locksarepreferredmeans.在正确位置挂牌Usethetaginrightplace.两种挂牌不可用于同一设备Thetwotypesoftagsshallnotbehungonthesamecomponent.决不可操作危险挂牌的设备。NoonemayoperateacomponentwiththeDangerTag.,ELECTRICALLOCKOUT电气开关锁定,56,其它要求及常见问题AdditionalRequirementandCommonIssue,57,对带电设备进行操作前,摘下首饰(如指环、项链、手表、手链等)。细察看潜在的危险:如潮湿的地板、不接地的扩展电源线、磨损的电源线;将紧急开关放在工作间,以便事故发生时,迅速切断电源;如果有潜在的危险,请不要单独工作;进行检查前,务必请断开电源;如果事故发生,关掉系统电源;报警;判断是否受害者需要进行人工呼吸,及时寻求医疗帮助。设备只允许经培训合格的人员操作和维护;系统上电前,请认真阅读安装指南。,带电作业,58,keepingaprescribedsafedistance(Attachtable)fromexposedenergizedlines,avoidingtheunsafeuseofelectricalequipment,andfollowinglockout/Tag-outprocedures.离开暴露的带电线路保持规定的安全距离(附表),避免使用不安全电气设备,遵守上锁或掛牌程序,59,Attachment附表,1.Theminimumsafeapproachdistanceforcranetopowerlineatfollow:起重机与架空导线低端的最小安全距离导线电压等级(KV)1以内1035110220330500垂直方向(m)1.53.04.05.06.07.08.5水平方向(m)1.52.03.54.06.07.08.52.Theminimumsafeapproachdistanceoperatepersonstonakedpowerlineatfollow:操作人员与带电体的最小安全距离设备电压等级(KV)10以内20354460110154220最小安全距离(m)0.40.60.91.5233.Theminimumsafeapproachdistanceforweldingtonakedpowerlineatfollow:电气焊作业与带电体的最小安全距离设备电压等级(KV)110以内10以上最小安全距离(m)11.534.Theminimumsafeapproachdistanceforoperatepersonsonpoleortowertonakedpowerlineatfollow:在带电线路的杆,塔上作业与带电体的最小安全距离导线电压等级(KV)10以内20354460110154220最小安全距离(m)0.711.21.523,60,Electricityhastheabilitytoarc,orjumpfromunguardedpowerlinestoanindividualincloseproximitytotheline.Quiteafewpeoplehavebeenkilledorinjuredwhilecarryingapieceofconductiveequipment,suchasaladder,inanelevatedpositionorbybeingincontactwithavehiclethatcomeswithinarcingrangeofanoverheadpowerline.电可产生电弧,能从未做防护的电源线跳到附近的人身上。所以有人在高处扛着一个导电的设备(如梯子)走的时候,或接触了处于架空电源线电弧范围内的车辆,触到电源线的电弧而死亡或受伤。,61,DuringHighpotentialinspectionsonelectricequipment,theareaaroundshouldbeclearandbarricadewithredropes,notauthorizedpersoncannotenter.电气设备作耐压试验时应保持设备周围有安全空间,人員不可进入,并围上警示帶,避免人员误入。Before,duringandafterDCHighVoltageinspection,workershouldusesuitableelectrographicpenciltotouchtheelectrifiedportionwheretheelectriccanbetouchedbygrounding.直流耐压实验时不论测试前后,人員接触帶电部份时均应先以验电笔验电,以免人员触电.Shouldassignapersontowatchandkeepotherpeopleasafedistanceaway.需有人員警戒避免人員誤接触造成触电。,62,BeforeEnergization,Visuallycheckandmakesuretheconnectionandrelayapparatusareingoodconditionandwithoutanyotherequipmentoncircuit.电气设备送电前以人工目视检查各輸配电设备內有无异物,各接点连接是否正常,继电保护設定是否正确.Anybodyshallbeinformedofemergencyalwayshappening.Whenoperatetheswitchbreakersnostandingoppositethebreakersisallowed.告知每一位参与者,再好的設备都可能发生故事,操作开关应避开正面位置,而以斜角或側面方式操作.,63,Informalltherelativedepartmentswithofficialnoticesenergizingareasshallbeclearlyshownonthedrawingsandgoodwarningsignssuchasunderenergizationshallbeavailableintheworkingarea.以正式文件通知相关单位人员送电危险区域及电压等級,並於明显处张贴平面图标示已送电区域,所有送电开关盘面应加掛标示送电中危险。Anyisolationworkforthepowersupplyswitchesshallbesignedwithwarningboardsandlocked.Powersupplyshallbetterbeoff.任何隔离工作必須参考单线图所示,隔离所有开关,并加掛告示牌及上锁,最好上一层电源切断。,64,HazardExposedElectricalParts危害-电器元件的曝露,Coverremovedfromwiringorbreakerbox电盒盖被移走,65,IsolateElectricalParts-Cabinets,Boxes&Fittings隔离电器元件-电柜,电箱或及装置,Conductorsgoingintothemmustbeprotected,andunusedopeningsmustbeclosed导体穿过必须有保护,并且不用的开口应密封,66,HazardOverloadedCircuits电路过载,过载会引起着火,67,SiteElectricityFacilitiesinBTESCaojing拜耳漕泾现场的电设施,68,SiteSubstation现场变电站,69,70,71,72,TDI项目配电箱要求,1.外装插座必须防水,三相380V插座一箱只允许装一个,单相220V允许装2个.2.中心点离地不小于0.8米.3.总电箱及分配电箱必须挂明锁并锁住.4.电箱有标识,包括单位名称,电工姓名,电话及警示标志.5.月检标签.6.地拖及拖线盘严禁使用.,73,总配电箱,74,分配电箱,75,开关箱外部要求,76,电箱的日检查,77,现场用电设备安全,78,焊接机械:电焊机械应放置在防雨,干燥和通风良好的地方,现场不得有易燃易爆物品.交流弧焊机变压器的一次侧电源线长度不应大于5米,其电源进线处必须设置防护罩.发电机式直流电焊机的换向器应经常检查和维护,应消除可能产生的异常电火花.电焊机械开关箱中的漏电保护器必须符合要求,交流电焊机械应配装防二次侧触电保护器.电焊机机械的二次线应采用防火橡皮护套铜芯软电缆,电缆长度不应大于30m,不得采用金属构件或结构钢筋代替二次线的地线;使用电焊机械焊接时必须穿戴防护用品严禁露天冒雨从事电焊作业,现场电气设备-焊机使用安全,79,地面抹光机、水磨石机、钢筋加工机械、木工机械等负荷线必须采用耐气候型橡皮护套铜芯软电缆,并不得有任何破损和接头水泵的负荷线必须采用防水型橡皮护套铜芯软电缆,严禁有任何破损和接头,并不得承受任何外力。对钢筋加工机械,木工机械设备进行清理、检查、维修时,必须首先将其开关箱分闸断电,呈现可见电源分断点,并关门上锁。,现场电气设备-其它建筑机械,80,触电急救措施,81,触电急救措施,触电急救的基本原则是在现场采取积极措施保护伤员生命,减轻伤情,减少痛苦,并根据伤情需要,迅速联系医疗部门救治。脱离电源触电急救,首先要使触电者迅速脱离电源,越快越好。因为电流作用的时间越长,伤害越重。在脱离电源时,救护人员既要救人,也要注意保护自己。触电者未脱离电源前,救护人员不准直接用手触伤员,因为有触电的危险;如触电者处于高处,解脱电源后会自高处坠落,因此,要采取预防措施。,82,触电者触及低压带电设备,救护人员应设法迅速切断电源,如拉开电源开关或刀闸、拔除电源插头等,或使用绝缘工具,如干燥的木棒、木板、绳索等不导电的东西解脱触电者;也可抓住触电者干燥而不贴身的衣服,将其拖开,切记要避免碰到金属物体和触电者的裸露身躯。,低压设备上的触电,83,如果触电者触及断落在地上的带电高压导线,如尚未确证线路无电,救护人员在未做好安全措施(如穿
温馨提示
- 1. 本站所有资源如无特殊说明,都需要本地电脑安装OFFICE2007和PDF阅读器。图纸软件为CAD,CAXA,PROE,UG,SolidWorks等.压缩文件请下载最新的WinRAR软件解压。
- 2. 本站的文档不包含任何第三方提供的附件图纸等,如果需要附件,请联系上传者。文件的所有权益归上传用户所有。
- 3. 本站RAR压缩包中若带图纸,网页内容里面会有图纸预览,若没有图纸预览就没有图纸。
- 4. 未经权益所有人同意不得将文件中的内容挪作商业或盈利用途。
- 5. 人人文库网仅提供信息存储空间,仅对用户上传内容的表现方式做保护处理,对用户上传分享的文档内容本身不做任何修改或编辑,并不能对任何下载内容负责。
- 6. 下载文件中如有侵权或不适当内容,请与我们联系,我们立即纠正。
- 7. 本站不保证下载资源的准确性、安全性和完整性, 同时也不承担用户因使用这些下载资源对自己和他人造成任何形式的伤害或损失。
最新文档
- 工程测量数据共享与应用方案
- 装配式混凝土结构质量验收标准方案
- 2026新疆师范大学招聘事业编制人员暨中学体育教师1人备考题库含答案详解(考试直接用)
- 2026福建漳州市诏安县融媒体中心招募见习人员2人备考题库及答案详解(各地真题)
- 2026四川雅安市名山区茗投产业集团有限公司招聘杰翎酒管公司温德姆酒店项目用工人员的9人备考题库附答案详解(培优)
- 2026内蒙古呼和浩特职业技术大学第二批人才引进23人备考题库含答案详解(研优卷)
- 2026重庆垫江县社会保险事务中心公益性岗位工作人员招聘2人备考题库及答案详解(必刷)
- 2026上半年黑龙江齐齐哈尔医学院及直属单位招聘编制内工作人员136人备考题库及答案详解(历年真题)
- 2026湖南张家界市消防救援支队招政府专职消防员31人备考题库及参考答案详解一套
- 2026北京大学工学院(本科生学院)招聘劳动合同制人员1人备考题库含答案详解(研优卷)
- 冲刺训练:圆压轴题(含解析)-2025年中考数学专项突破
- 中华诗词大赛1-3年级题库(含答案)
- DB62-T 3255-2023 建筑工程施工扬尘防治技术标准
- 外包外委作业管理制度
- CJ/T 358-2019非开挖工程用聚乙烯管
- 重庆广汇供电服务有限责任公司招聘笔试真题2024
- 门窗质保合同协议书范本
- 数据保护与合规标准试题及答案
- 大学生春季传染病预防指南
- 多模态信息处理与认知负荷-洞察阐释
- Unit4 Eat Well Section B (1a-1d) 课件 2024-2025学年人教版七年级英语下册
评论
0/150
提交评论