




已阅读5页,还剩12页未读, 继续免费阅读
版权说明:本文档由用户提供并上传,收益归属内容提供方,若内容存在侵权,请进行举报或认领
文档简介
Template Revision 2 3 2003 11 06 OTIS Engineering Center Berlin Software Basic Data MCS LCB II Software Baseline Release Document No GAA30082CAC BRD SCN GAA30082CAC Page 1 17 Date 2003 11 21 MCS LCB II Software Baseline Release Document Copyright 2003 OTIS GmbH Co OHG Berlin No part of this document may be copied or reproduced in any form or by any means without the prior written consent of OTIS Running on PCB GCA 21240 D1 D3 or higher LCBII Document Revision DateAuthorComment 2003 11 21A PfefferOriginal Document Template Revision 2 3 2003 11 06 OTIS Engineering Center Berlin Software Basic Data MCS LCB II Software Baseline Release Document No GAA30082CAC BRD SCN GAA30082CAC Page 2 17 Date 2003 11 21 Release Status Preserie Limited Full Quality Approvals FunctionNameSignatureDate OriginatorA Pfeffer Software ResponsibleS Seelmann Project Product Resp M Gremm Software AdministratorDr Spielbauer Engineering Resp H Horbr gger Product SupportD Schenkel Product QualificationG Stricker Quality AssuranceR M ller For the limited and full production release the document was approved by the sign ers and authorized by the PEGASUS administrator Template Revision 2 3 2003 11 06 OTIS Engineering Center Berlin Software Basic Data MCS LCB II Software Baseline Release Document No GAA30082CAC BRD SCN GAA30082CAC Page 3 17 Date 2003 11 21 Software Change History DateSCNComments GAA 30079 AAA GAA 30079 AAB GAA 30079 AAC GAA 30079 AAD Engineering versions no field use 1993 05 24GAA 30082 AAANot compatible to GAA 30079 AAA AAD Changes New memory layout LEDs added Used EPROM size 27C512 1993 12 03GAA 30082 AABCompatible to GAA 30082 AAA Changes PCB 180 deg turned DDO CHCS inverted OTIS 2000 features added e g DCS Used EPROM size 27C512 1994 04 29GAA 30082 AACCompatible to GAA 30082 AAB Changes Memory model changed to Medium ROM Triplex functionality added Used EPROM size 128 Kbytes e g 27C1001 1994 06 02GAA 30082 AADCompatible to GAA 30082 AAC Changes Secure Access mode SAC revised Debouncing of TCI 1LS and 2LS signals added Used EPROM size 128 Kbytes e g 27C1001 1994 06 16GAA 30082 AAECompatible to GAA 30082 AAD Changes TCI run up for hydraulic drive corrected BSM mode for DCL operation added door closing operation for DO2000 with Door By Pass corrected other see Modification Description GAA30082AAE011 Revised Software compatible to GAA 30082 AAE Changes Service Tool init revised 110V output init corrected stop on UIS DIS corrected Hydro and Shortrun TCI limit corrected 1 Speed and stop on IPU IPD DBP Fault Deenergize doors if PES is operated other see Modification Description 1994 10 25GAA30082AAE022 Revised Software compatible to GAA 30082 AAE Changes OOS REM signal according to REM III IQA SAPB Preference time handling corrected other see Modification Description 1994 12 02GAA30082AAE033 Revised Software compatible to GAA 30082 AAE Changes OOS REM signal corrected for ESB mode Template Revision 2 3 2003 11 06 OTIS Engineering Center Berlin Software Basic Data MCS LCB II Software Baseline Release Document No GAA30082CAC BRD SCN GAA30082CAC Page 4 17 Date 2003 11 21 DateSCNComments 1995 01 17GAA 30082 BAACompatible to GAA 30082 AAE Not compatible to Gxx 30082 AAF changed interface to LSVF W Changes MCS 220 M features added e g RSS MLI MCG PDD CMR LSVF W added REM III added other see Modification Description 1995 06 02GAA 30082 BABCompatible to GAA 30082 BAA Changes ELD custom messages REM serial link ATT DOC X CPI 3 HPI 3 3 wire buttons n 2 wiring 1995 06 27GAA 30082 BACCompatible to GAA 30082 BAB Changes DCL signal corruption tolerated 1995 12 13GAA 30082 BADCompatible to GAA 30082 BAC Changes support of OVF10 and OVF20 MPD 3 EHS 2 Hydraulic featured corrected Stopping accuracy increased New TCI Lock Procedure 1996 01 11GAA30082BAD01Revised Software compatible to GAA 30082 BAD Changes Calibration of OVF10 allowed before DCS 10 runs max 1996 06 21GAA30082BAECompatible to GAA 30082 BAD01 Changes slow start for OVF10 and OVF20 FIS LSCH 2 for hydraulic Generic Door Operator Generic Firemen Service 1997 04 09GAA30082BAFCompatible to GAA 30082 BAE Changes slow start now selectable for OVF10 and OVF20 AHVS Cargo 2000 for MCS120 MCS220M variable input display for Service Tool MIT MOT SKL 3 1997 07 21GAA30082BAF01Revised software Compatible to GAA 30082 BAF Changes OVF20 with FLH ESB with n 2 wiring FPD handling Template Revision 2 3 2003 11 06 OTIS Engineering Center Berlin Software Basic Data MCS LCB II Software Baseline Release Document No GAA30082CAC BRD SCN GAA30082CAC Page 5 17 Date 2003 11 21 DateSCNComments 1998 02 25GAA30082BAGCompatible to GAA 30082 BAF01 Changes MCS120M Hydraulic parking Brake Fault improvements 1999 05 17GAA30082BAHCompatible to GAA 30082 BAG Changes REM G and HKM EFS with BS7255 REM OOS signal handling improved several event messages renamed DOB CCB handling in case of drive faults LSCH 2 for Motorized Valve 2000 03 29GAA30082BAJCompatible to GAA 30082 BAH Changes LS Fault handling TCI Adress Check Door reversals with lost position DO 5 2001 01 18GAA30082CAACard Reader Operation not compatible to GAA 30082 BAJ All other functions compatible to GAA 30082 BAJ Changes Card Reader Operation LNS C LWO C PRS 4 Ring ICD 4 2 Australian code Smart Button new Shabat options REM SL SVT communication problem fixed 2002 03 14GAA30082CABCompatible to GAA 30082 CAA Changes RBU 1 Bode Rope Brake PIUMA Door DDP Handling for Hydraulic RLEV with Overload for Hydraulic 2003 11 21GAA30082CACCompatible to GAA 30082 CAB REM5LD LVC Timing EFS without correction run Template Revision 2 3 2003 11 06 OTIS Engineering Center Berlin Software Basic Data MCS LCB II Software Baseline Release Document No GAA30082CAC BRD SCN GAA30082CAC Page 6 17 Date 2003 11 21 Configuration Identification GAA30082CACWorldwide EN standard baseline software for LCBII Engineering Authorization Date 2003 11 21 Parent Baseline Number GAA 30082 CAB Affected Component Contract Factory Argenteuil Brazil SBC Sao Bernardo Breclav Cernusco SSI Berlin China Tianjin Guangzhou Xizi CLC MOD Gien India Bangalore Madrid Stadthagen Shibayama Limitations none Template Revision 2 3 2003 11 06 OTIS Engineering Center Berlin Software Basic Data MCS LCB II Software Baseline Release Document No GAA30082CAC BRD SCN GAA30082CAC Page 7 17 Date 2003 11 21 Deliverable Media Download from Pegasus or programmed PROM PROM Part IdentificationStandard Baseline Programmed PROM Order Number GAA30082CAC1 Number or Required PROMS 1 OTIS Blank Part Number 27C1001 GO 616 BS 4 GAA 616 HK1 Blank Label Part Number GAA 102 AFL 4 Programming Instructions Intel Hex File GAA30082CAC HEX Start address 0000 Processor 8088 V20 Checksum E481 Word length bit 8 fill unused bytesFF PROM labeling data Copyright 2003 OTIS GAA30082CAC1 LCB IIZ12 10 03 E481 Z12 PROM location on PCB 10 03 date of programming E481 checksum Template Revision 2 3 2003 11 06 OTIS Engineering Center Berlin Software Basic Data MCS LCB II Software Baseline Release Document No GAA30082CAC BRD SCN GAA30082CAC Page 8 17 Date 2003 11 21 Contract specific EEPROM Programmed EEPROM Order Number E1 Number or Required EEPROMS 1 OTIS Blank Part Number must have page write mode e g Sam sung KM28C64 GO 616 BP 3 Blank Label Part Number GAA 102 AFL 4 Programming Instructions Intel Hex File E HEX Start address 0000 Processor 8088 V20 Word length bit 8 fill unused bytesFF EEPROM labeling data Copyright 2003 OTIS LCB IIZ1010 03 Z12 EEPROM location on PCB 10 03 date of programming Standard EEPROMs ApplicationOrder numberIntel Hex File Check sum PS File Spare part G 21240 D1 GAA 30083 AAD111GAA30083AAD11 HEX51FF GAA30083AAD11 GAA30082CAC PS Note higher versions are also applicable Template Revision 2 3 2003 11 06 OTIS Engineering Center Berlin Software Basic Data MCS LCB II Software Baseline Release Document No GAA30082CAC BRD SCN GAA30082CAC Page 9 17 Date 2003 11 21 Dependencies 1 This software runs on LCB II version GCA 21240 D1 D2 D3 or higher 2 Compatible to EMS V 1 5 or higher configured for Ring ICD V 3 3 3 Duplex Triplex MCS120 MCS220 MCS220M controllers must have the same software version 4 Duplex MCS310 controller in a group with MCS220M must have software version GOF616G44 on LCB1 C9693A2 or GOA616G57 on LCB1 C9693A3 or later ver sions 5 Controllers with LSVF drive package KEB have to be equipped with software version GAA30149CAA or later on MCB A 9693 CD1 6 Controllers with LSVF W drive package have to be equipped with software version GAA30150BAA or later on MCB II GAA 26800 H1 or later 7 Controllers with OVF20 drive package and FLH MCG must be equipped with software version GAA30158AAE or later on MCB II GBA 26800 H1 or later OVF20 with learn run required 8 OTIS2000 ELD RevD is required to display the full character set as large letters RevC can only display the characters 0 9 B E G K L P T 9 DO 5 must be equipped with software GAA30328AAB or later 10 Factory Testsoftware must be GAA30159AAA or higher Open Items 1 With short landings at terminal floors no access to terminal floors with TCI Reference Documents TitleDocument Number SVT User s Guide ManualGAA30082CAC Stm SVT User s Guide Reference ListGAA30082CAC Ref Installation ParametersGAA30082CAC Ins RSL List of I OsGAA30082CAC IO Feature Setup DescriptionGAA30082CAC Fsd Template Revision 2 3 2003 11 06 OTIS Engineering Center Berlin Software Basic Data MCS LCB II Software Baseline Release Document No GAA30082CAC BRD SCN GAA30082CAC Page 10 17 Date 2003 11 21 Modification Description SCR Number 30082 221 Classification Corrective Title Card Reader with DDO Description Copying of car calls between COPs has been corrected for Card Reader Operation Impact Double COP Parameters EN CRO 0 EN DDO 0 SCR Number 30082 222 Classification Corrective Title CTR 73 02 105 avoid TCI Lock for TLD ACG Description TCI Lock is cleared when any landing door is opened Previous software versions did only monitor the manual landing door Impact MD AES 1 SCR Number 30082 233 Classification Perfective Title OLD 2 keep car calls Description Option added to remember existing car calls during Overload feature OLD 2 Impact Parameter 02 OCSS OLD TYP 1 Template Revision 2 3 2003 11 06 OTIS Engineering Center Berlin Software Basic Data MCS LCB II Software Baseline Release Document No GAA30082CAC BRD SCN GAA30082CAC Page 11 17 Date 2003 11 21 SCR Number 30082 240 Classification Perfective Title Reduce Code Remove C2 Loading Description The feature Class C2 Loading was never released and has been removed from the soft ware Several parameters and I Os have been removed Impact Parameters 07 CARGO BI T BO T MVU T MVD T PLS4 T I Os 681 688 Events 0217 0223 SCR Number 30082 241 Classification Adaptive Title CTR 32 01 024 Improve timing for LVC relay Description Software timing has been adapted to the requirements of Sirius relays Sometimes the software showed immediately after the doors began to close As a result the door was not reopened when the LRD was activated Impact ADO RLV SCR Number 30082 242 Classification Corrective Title Correct ACD and LSCH2 Description Correct LSCH 2 with ACD Impact EN ACD 3 Template Revision 2 3 2003 11 06 OTIS Engineering Center Berlin Software Basic Data MCS LCB II Software Baseline Release Document No GAA30082CAC BRD SCN GAA30082CAC Page 12 17 Date 2003 11 21 SCR Number 30082 243 Classification Corrective Title keep EMS Security option when ICSS fails Description Landings will still be secured when ICSS is switched off Impact SCR Number 30082 244 Classification Corrective Title CTR 45 02 C305 DO 5 with ACG Description Prevent closing of the car door when landing door is opened Impact DOOR 12 13 EN ACG 1 SCR Number 30082 245 Classification Adaptive Title CTR 32 03 15 Avoid sporadic SE Fault Description Sporadic detection of SE Fault has been fixed Impact door bypass enabled SCR Number 30082 246 Classification Corrective Title avoid correction run after Power Loss during EFS Description Avoid correction run if power is lost during EFS Impact EN BAK 1 HDWPOS 3 Template Revision 2 3 2003 11 06 OTIS Engineering Center Berlin Software Basic Data MCS LCB II Software Baseline Release Document No GAA30082CAC BRD SCN GAA30082CAC Page 13 17 Date 2003 11 21 SCR Number 30082 248 Classification Corrective Title Correct Display of Info Messages Description The information display for the selected operation type is corrected Impact Service Tool menu M UP Parameter OPERAT SCR Number 30082 250 Classification Corrective Title OOL outputs not working for all openings Description All OOLxx outputs are switched on if the car is out of service Impact I Os 878 909 OOL0 OOL31 SCR Number 30082 252 Classification Perfective Title CTR 73 02 110 SAC increased time window to enter a code Description Time to enter a SAC code is changed from 5 seconds to 8 seconds Impact Parameter SACTYP SCR Number 30082 254 Classification Perfective Title REM5 LD Description The signals BRK SAF DS CLM DOP RDOP are transitted to REM via serial link Impact Template Revision 2 3 2003 11 06 OTIS Engineering Center Berlin Software Basic Data MCS LCB II Software Baseline Release Document No GAA30082CAC BRD SCN GAA30082CAC Page 14 17 Date 2003 11 21 SCR Number 30082 255 Classification Adaptive Title Handle EPO EFS Priority Description EFO and EFS have priority over EPO In case of Emergency Power NUSD must be active to allow any runs Impact EN BAK 1 HDWPOS 3 EFO P 32 EPO P 32 SCR Number 30082 260 Classification Corrective Title CTR 73 02 105 correct DCS for TLD CLD ACG Description Im some cases DCS could fail if TLD and ACG doors exists in the same hoistway Impact Parameter MD AES 1 SCR Number 30082 261 Classification Preventive Title CTR C5 03 05 prevent RSL impulse during start up Description Startup behavior of RSL improved Impact SCR Number 30082 266 Classification Corrective Title correct ISC 4 Description If several calls are entered the car restarted immediately without opening the doors Impact Parameter 02 OCSS ISC 4 Template Revision 2 3 2003 11 06 OTIS Engineering Center Berlin Software Basic Data MCS LCB II Software Baseline Release Document No GAA30082CAC BRD SCN GAA30082CAC Page 15 17 Date 2003 11 21 SCR Number 30082 267 Classification Corrective Title correct EMS SEC 1 Description If EMS SEC 1 was selected with previous software versions car calls could be entered even in normal mode Impact Parameter 09 Security EMS SEC 1 SCR Number 30082 268 Classification Adaptive Title Hydraulic Star Delta with pump run delay Description At the end of a run U and UX are pulled together to keep the pump active for UXT D Impact Parameters 04 Drive UXT D 2 3 HY TYP3 SCR Number 30082 269 Classification Corrective Title SE Fault and DOB Description DOB is always enabled in case of SE Fault Impact Parameters GROUP 1 ARD P255 Template Revision 2 3 2003 11 06 OTIS Engineering Center Berlin Software Basic Data MCS LCB II Software Baseline Release Document No GAA30082CAC BRD SCN GAA30082CAC Page 16 17 Date 2003 11 21 SCR Number 30082 271 Classification Perfective Title Change PI Handling avoid early counting of position Description Options added for floor information on position indicator Actual Floor default Next Commitable Falling edge of DZ Rising edge of DZ Impact Parameter PI POS SCR Number 30082 275 Classification Corrective Title SKL with LR Description The car light is only monitored if LR is inactive Impact Parameter LR T I O 1000 CLR SCR Number 30082 283 Classification Adaptive Title CTR 73 99 105 TCI Lock after short power failures Description TCI is ignored if it is operated for shorter than 500ms This avoids sporadic TCI Lock call backs if the power is dropped for a short time Impact I O 691 TCI Total Corrections 13 Total Enhancements 11 Total SCRs 24 Template Revision 2 3 2003 11 06 OTIS Engineering Center Berlin Software Basic Data MCS LCB II Software Baseline Release Document No GAA30082CAC BRD SCN GAA30082CAC Page 17 17 Date 2003 11 21 Qualification and Verification Procedure Release Candidate G20 30082 CAC Software Qualification Report Q 03 19 D Following RRCA are applicable None The Release Candidate has been successfully tested at the CTL production tester 45NALF21 OVF10 03 Dec 2003 54NM9424 Hydraulik 03 Dec 2003 The latest c
温馨提示
- 1. 本站所有资源如无特殊说明,都需要本地电脑安装OFFICE2007和PDF阅读器。图纸软件为CAD,CAXA,PROE,UG,SolidWorks等.压缩文件请下载最新的WinRAR软件解压。
- 2. 本站的文档不包含任何第三方提供的附件图纸等,如果需要附件,请联系上传者。文件的所有权益归上传用户所有。
- 3. 本站RAR压缩包中若带图纸,网页内容里面会有图纸预览,若没有图纸预览就没有图纸。
- 4. 未经权益所有人同意不得将文件中的内容挪作商业或盈利用途。
- 5. 人人文库网仅提供信息存储空间,仅对用户上传内容的表现方式做保护处理,对用户上传分享的文档内容本身不做任何修改或编辑,并不能对任何下载内容负责。
- 6. 下载文件中如有侵权或不适当内容,请与我们联系,我们立即纠正。
- 7. 本站不保证下载资源的准确性、安全性和完整性, 同时也不承担用户因使用这些下载资源对自己和他人造成任何形式的伤害或损失。
最新文档
- 公司经营拓展活动方案
- 公司职工小活动方案
- 公司节目拍摄策划方案
- 公司热爱劳动活动方案
- 公司组织室内活动方案
- 公司社交酒会策划方案
- 公司网络年会策划方案
- 公司爬圭峰山活动方案
- 公司普通聚餐活动方案
- 公司月动员会策划方案
- 2023年副主任医师(副高)-神经外科学(副高)历年考试真题试卷摘选答案
- 年产20万吨废纸脱墨新闻纸造纸车间设计
- 金融系统反洗钱考试题库(含答案)
- 《短歌行》《归园田居(其一)》比较阅读
- 随班就读学生“一人一案”个别化教育工作手册
- 女患者尿道口护理操作标准
- 食物与药物的相互作用
- 规范申报专题培训-课件
- 精神病症状学(psychopathology)课件
- 华泰基本面轮动系列之七:行业配置策略趋势追踪视角
- “一站到底”知识竞赛题库及答案(1590题)
评论
0/150
提交评论