文档简介

BILL NO. 1DIVISION 16 - ELECTRICAL WORKSItemDescriptionQtyUnitRateAmountSDGSDGA BC D EELECTRICAL ENGINEERING INSTALLATION PreambleThis BOQ shall be read in conjunction with parts of the electrical technical specifications general and particular and the electrical drawings except where otherwise indicated. The unit price for all items in all sections shall include for supplying, installation and commissioning unless otherwise specially mentioned. the price is also including submittal of working drawings, as built drawings and coordinating drawings by sheets and by computer diskettes. all civil & finishing works related to the unit price, unless otherwise indicated and according contract documents requirements.EquipmentUninterruptible Power Supply (UPS)Supply, Installation, testing static uninterruptible power supply(UPS) unit including all necessary connections, completeUPS-1 60 KVA for general use - 30 minutes UPS-2 30 KVA for Server - 30 minutes Motor Control CenterMotor control centers including all necessary MCCBs, MCB,busbars, casing meters, starters, fuse switches,contactors, over load, relays, pulse relays, indication lamps, ampermeter, voltmeter, push buttons, accessories, fixings, selector switches, earthing and protection, completeMCC-B MCC-1STMCC-ROOF11111No. No.No. No. No.Carried To Collection SDGDefaf Mourjan City - BOQ - Hotel-1/16/9ItemDescriptionQtyUnitRateAmountSDGSDGA B C D E F G H IJ K LMELECTRICAL ENGINEERING INSTALLATION Main, Sub main, and SecondaryDistribution BoardsSub main distribution boards including all necessary MCCBs, MCBs bus bars, coupling units, casing, cable clamps, earthing and protection equipment, completeRef. SMDB-1Ref. SMDB-2Ref. SMDB-3Ref. SMDB-KIT. Ref. SMDB-LAN. Ref. SMDB-U Ref. SMDB-G.F Ref. SMDB-1ST. Ref. SMDB-S-1Ref. SMDB-S-2Ref. SMDB-TYP. Ref. SMDB-10TH Ref. SMDB-11TH1111111111711No. No. No. No. No. No. No. No. No. No. No. No. No.Carried To Collection SDGItemDescriptionQtyUnitRateAmountSDGSDGA B C D E F G H IJ K LMN O P Q R SELECTRICAL ENGINEERING INSTALLATION(CONTD) Main, Sub main, and SecondaryDistribution BoardsSecondary distribution boards including all necessary , MCCBs, MCBs, isolating switch, bus bars, natural terminal, earthing terminal, coupling units, casing, cable clamps, earthing and protection equipment, completeRef. DB-KIT Ref. DB-KIT2Ref. DB-BAS2. Ref. DB-BAS1Ref. DB-DIN. Ref. DB-ENG. Ref. DB-LAN. Ref. DBU-B.M.S Ref. DBU-B1Ref. DBU-B2Ref. DB-G.F1Ref. DB-G.F2Ref. DB-S1Ref. DB-S2Ref. DB-S3Ref. DBU-G.F Ref. DB-1ST.1Ref. DBL-1ST Ref. DB-1ST.2111111111111111111No. No. No. No. No. No. No. No. No. No. No.No.No. No. No. No. No. No.Carried To Collection SDGItemDescriptionQtyUnitRateAmountSDGSDGA BC D E F G H IJ KELECTRICAL ENGINEERING INSTALLATION (CONTD) Main, Sub main, and Secondary Distribution BoardsSecondary distribution boards including all necessary , MCCBs,MCBs, isolating switch, bus bars, natural terminal, earthing terminal, coupling units, casing, cable clamps, earthing and protection equipment, completeRef. DBU-SERVER Ref. DBU-1STDB-2ND.1DB-2ND.2DBU-2ND DB-TYP. DBU-T1DBU-T2DB-10TH DB-11TH DB-CLB11111711111No. No.No. No. No. No. No. No. No. No. No.Carried To Collection SDGItemDescriptionQtyUnitRateAmountSDGSDGA B C DEF G H IJ K LM NOP QELECTRICAL ENGINEERING INSTALLATION (CONTD) Main, Sub main, and Secondary Distribution BoardsSecondary distribution boards with KNX actuators including all necessary MCCBs, MCBs, dimming actutors, switch actuators, intelligent control units for guest rooms, module extension ,EIB gateway,KNX power supply ,AHU actuators, bus bars, natural terminal, earthing terminal, coupling units, casing, cable clamps, earthing and protection equipment, completeRef. DB-S-G1Ref. DB-S-G2Ref. DB-S-G3Ref. DB-S-G4Ref. DB-S-G5Ref. DB-S-G6Ref. DB-S-G7Ref. DB-S-G8Ref. DB-S-G9Ref. DB-S-G10Ref. DB-S-G11Ref. DB-S-G12Ref. DB-S-G13Ref. DB-S-G14Ref. DB-S-G15Ref. DB-S-G16Ref. DB-S-G1711111111111111111No. No. No. No.No.No. No. No. No. No. No. No.No. No.No.No. No.Carried To Collection SDGItemDescriptionQtyUnitRateAmountSDGSDGA B C D E F G H IJ K LM N O P Q RELECTRICAL ENGINEERING INSTALLATION (CONTD) Main, Sub main, and SecondaryDistribution BoardsSecondary distribution boards with KNX actuators including allnecessary MCCBs, MCBs, dimming actutors, switch actuators, intelligent control units for guest rooms, module extension ,EIB gateway,KNX power supply ,AHU actuators, bus bars, natural terminal, earthing terminal, coupling units, casing, cable clamps, earthing and protection equipment, completeRef. DB-S-G18Ref. DB-S-G19Ref. DB-S-G20Ref. DB-S-G21Ref. DB-S-G22Ref. DB-S-G23Ref. DB-S-G24Ref. DB-S-G25Ref. DB-S-G26Ref. DB-S-G27Ref. DB-S-G28Ref. DB-S-G29Ref. DB-S-G30Ref. DB-S-G31Ref. DB-S-G32Ref. DB-S-G33Ref. DB-S-G34Ref. DB-S-G35111111111111111111No. No. No. No. No. No. No. No. No. No. No. No. No. No. No. No. No. No.Carried To Collection SDGItemDescriptionQtyUnitRateAmountSDGSDGA B C D E F G H IJ K LM N O P Q RELECTRICAL ENGINEERING INSTALLATION (CONTD) Main, Sub main, and SecondaryDistribution BoardsSecondary distribution boards with KNX actuators including allnecessary MCCBs, MCBs, dimming actutors, switch actuators, intelligent control units for guest rooms, module extension ,EIB gateway,KNX power supply ,AHU actuators, bus bars, natural terminal, earthing terminal, coupling units, casing, cable clamps, earthing and protection equipment, completeRef. DB-S-G36Ref. DB-S-G37Ref. DB-S-G38Ref. DB-S-G39Ref. DB-S-G40Ref. DB-S-G41Ref. DB-S-G42Ref. DB-S-G43Ref. DB-S-G44Ref. DB-T-G1Ref. DB-T-G2Ref. DB-T-G3Ref. DB-T-G4Ref. DB-T-G5Ref. DB-T-G6Ref. DB-T-G7Ref. DB-T-G8Ref. DB-T-G9Ref. DB-T-G101111111117777777777No. No.No. No. No. No. No. No. No. No. No. No. No. No. No. No. No. No. No.Carried To Collection SDGItemDescriptionQtyUnitRateAmountSDGSDGA B C D E F G H IJ K LM N O P QELECTRICAL ENGINEERING INSTALLATION (CONTD) Main, Sub main, and SecondaryDistribution BoardsSecondary distribution boards with KNX actuators including allnecessary MCCBs, MCBs, dimming actutors, switch actuators, intelligent control units for guest rooms, module extension ,EIB gateway,KNX power supply ,AHU actuators, bus bars, natural terminal, earthing terminal, coupling units, casing, cable clamps, earthing and protection equipment, completeRef. DB-T-G11Ref. DB-T-G12Ref. DB-T-G13Ref. DB-T-G14Ref. DB-T-G15Ref. DB-T-G16Ref. DB-T-G17Ref. DB-T-G18Ref. DB-T-G19Ref. DB-T-G20Ref. DB-T-G21Ref. DB-T-G22Ref. DB-T-G23Ref. DB-G1Ref. DB-G2Ref. DB-G3Ref. DB-G477777777777777777No. No. No. No. No. No. No. No. No. No. No. No. No. No. No. No. No.Carried To Collection SDGItemDescriptionQtyUnitRateAmountSDGSDGA B C D E FGELECTRICAL ENGINEERING INSTALLATION (CONTD) Dimming systemDimming PanelsSupply, Installation, testing and commissioning of dimming system including dimmer racks, control plate, conduits, wiring, bus bars, natural terminal, earthing terminal, coupling units, MCBs, interfacing with EIB system completeDP-G.F1DP-RES DP-G.F2DP-1ST.1DP-RES2DP-1ST.2Supply, Installation, testing and commissioning of EIB cable between all gust rooms distribution boards, dimming panels, KNX/EIB panels, key pads to main IP router at BMS room including all necessary conduits, cables, wires, junction and pull boxes, connections, fittings and accessories, completeEIB points loop1111111No. No. No. No. No. No.L.SCarried To Collection SDGBILL NO. 1DIVISION 16 - ELECTRICAL WORKSItemDescriptionQtyUnitRateAmountSDGSDGA B CD E F G H IBus Duct SystemFive core bus duct ( TPN + E ), complete with all bends, end caps, feeder box, brackets, flange, and all necessary accessories and fixing material, as detailed in technical specifications and shown on drawings.(tap off are excluded from busway length measurementBus Duct - 1 (B.D.-1) 2250A TPN+E(50 KA) Bus Duct - 2 (B.D.-2) 2000A TPN+E(50 KA) Bus Duct - 3 (B.D.-3) 1200A TPN+E(50KA)Supply, installation, testing and commissioning of tap off units complete as specified and as shown on drawings as per specifications.800 A tap off600 A tap off400 A tap off250 A tap off200 A tap off100 A tap off11515080111731m m mNo. No. No. No. No. No.Carried To Collection SDGDefaf Mourjan City - BOQ - Hotel-1/16/19BILL NO. 1DIVISION 16 - ELECTRICAL WORKSItemDescriptionQtyUnitRateAmountSDGSDGELECTRICAL ENGINEERING INSTALLATION(CONTD) Wires and Cables(Contd)Feeders, cables including all necessary supports brackets, lugs, glands, cable terminal, conduits, ducts, accessories and connections, between main boards, sub-main boards and final distribution boards including terminations, complete as shown on drawings and as per specifications.(4 240)mm2 CU/XLPE/PVC + (1 120)mm2 Y/G PVC FROM BUSBAR TO MCC ROOF4x70mm2 CU/XLPE/PVC CABLE+1x35mm2 Y/G PVC CABLE FROM BUSBAR TO SMDB-11TH4x50mm2 CU/XLPE/PVC CABLE+1x35mm2 Y/G PVC CABLE FROM SMDB-11TH TO DB-CLB4x16mm2 CU/XLPE/PVC CABLE+1x16mm2 Y/G PVC CABLE FROM SMDB-11TH TO DB-11TH4x10mm2 CU/PVC/PVC CABLE+1x10mm2 Y/G PVC CABLE FROM SMDB-11TH TO LIFT4x10mm2 CU/PVC/PVC CABLE+1x10mm2 Y/G PVC CABLE FROM SMDB-11TH TO LIFT4x10mm2 CU/PVC/PVC CABLE+1x10mm2 Y/G PVC CABLE FROM SMDB-11TH TO LIFT4x25mm2 CU/XLPE/PVC CABLE+1x16mm2 Y/G PVC CABLE FROM BUSBAR TO SMDB-10TH4x6mm2 CU/PVC/PVC CABLE+1x6mm2 Y/G PVC CABLE FROM SMDB-10TH TO DB-10TH4x70mm2 CU/XLPE/PVC CABLE+1x35mm2 Y/G PVC CABLE FROM BUSBAR TO SMDB-TYP3x6mm2 CU/PVC/PVC CABLE FROM SMDB-TYP TO DB-T-13x6mm2 CU/PVC/PVC CABLE FROM SMDB-TYP TO DB-T-23x6mm2 CU/PVC/PVC CABLE FROM SMDB-TYP TO DB-T-33x6mm2 CU/PVC/PVC CABLE FROM SMDB-TYP TO DB-T-44015151545403515153040382825m m mm m m m m mmm m mmA BC DEF G H IJK L MNCarried To Collection SDGItemDescriptionQtyUnitRateAmountSDGSDGA BC D E F G H IJ K LM N O PELECTRICAL ENGINEERING INSTALLATION(CONTD) Wires and Cables(Contd)Feeders, cables including all necessary supports brackets, lugs,glands, cable terminal, conduits, ducts, accessories and connections, between main boards, sub-main boards and final distribution boards including terminations, complete as shown on drawings and as per specifications.3x6mm2 CU/PVC/PVC CABLE FROM SMDB-TYP TO DB-T-53x6mm2 CU/PVC/PVC CABLE FROM SMDB-TYP TO DB-T-63x6mm2 CU/PVC/PVC CABLE FROM SMDB-TYP TO DB-T-73x6mm2 CU/PVC/PVC CABLE FROM SMDB-TYP TO DB-T-83x6mm2 CU/PVC/PVC CABLE FROM SMDB-TYP TO DB-T-93x6mm2 CU/PVC/PVC CABLE FROM SMDB-TYP TO DB-T-103x6mm2 CU/PVC/PVC CABLE FROM SMDB-TYP TO DB-T-113x6mm2 CU/PVC/PVC CABLE FROM SMDB-TYP TO DB-T-123x6mm2 CU/PVC/PVC CABLE FROM SMDB-TYP TO DB-T-133x6mm2 CU/PVC/PVC CABLE FROM SMDB-TYP TO DB-T-143x6mm2 CU/PVC/PVC CABLE FROM SMDB-TYP TO DB-T-153x6mm2 CU/PVC/PVC CABLE FROM SMDB-TYP TO DB-T-163x6mm2 CU/PVC/PVC CABLE FROM SMDB-TYP TO DB-T-173x6mm2 CU/PVC/PVC CABLE FROM SMDB-TYP TO DB-T-183x6mm2 CU/PVC/PVC CABLE FROM SMDB-TYP TO DB-T-193x6mm2 CU/PVC/PVC CABLE FROM SMDB-TYP TO DB-T-2018151518343642454840383025182025m mm m m m m m m m m m m m m mCarried To Collection SDGItemDescriptionQtyUnitRateAmountSDGSDGA B C DEF GH IJ K LM N O PELECTRICAL ENGINEERING INSTALLATION(CONTD) Wires and Cables(Contd)Feeders, cables including all necessary supports brackets, lugs, glands, cable terminal, conduits, ducts, accessories and connections, between main boards, sub-main boards and final distribution boards including terminations, complete as shown on drawings and as per specifications.3x6mm2 CU/PVC/PVC CABLE FROM SMDB-TYP TO DB-T-213x6mm2 CU/PVC/PVC CABLE FROM SMDB-TYP TO DB-T-223x6mm2 CU/PVC/PVC CABLE FROM SMDB-TYP TO DB-T-233x6mm2 CU/PVC/PVC CABLE FROM SMDB-TYP TO DB-TYP4x120mm2 CU/XLPE/PVC CABLE+1x70mm2 Y/G PVC CABLE FROM BUSBAR TO SMDB-S-14x120mm2 CU/XLPE/PVC CABLE+1x70mm2 Y/G PVC CABLE FROM BUSBAR TO SMDB-S-23x6mm2 CU/PVC/PVC CABLE FROM SMDB-S-1 TO DB-S-G13x6mm2 CU/PVC/PVC CABLE FROM SMDB-S-1 TO DB-S-G23x6mm2 CU/PVC/PVC CABLE FROM SMDB-S-1 TO DB-S-G33x6mm2 CU/PVC/PVC CABLE FROM SMDB-S-1 TO DB-S-G43x6mm2 CU/PVC/PVC CABLE FROM SMDB-S-1 TO DB-S-G53x6mm2 CU/PVC/PVC CABLE FROM SMDB-S-1 TO DB-S-G63x6mm2 CU/PVC/PVC CABLE FROM SMDB-S-1 TO DB-S-G73x6mm2 CU/PVC/PVC CABLE FROM SMDB-S-1 TO DB-S-G83x6mm2 CU/PVC/PVC CABLE FROM SMDB-S-1 TO DB-S-G93x6mm2 CU/PVC/PVC CABLE FROM SMDB-S-1 TO DB-S-G1032384515225218151515252838404855m m m mm mmm m mm m m m m mCarried To Collection SDGBILL NO. 1DIVISION 16 - ELECTRICAL WORKSItemDescriptionQtyUnitRateAmountSDGSDGA B C D E F G HI J K LMN O P QELECTRICAL ENGINEERING INSTALLATION(CONTD) Wires and Cables(Contd)Feeders, cables including all necessary supports brackets, lugs, glands, cable terminal, conduits, ducts, accessories and connections, between main boards, sub-main boards and final distribution boards including terminations, complete as shown on drawings and as per specifications.3x6mm2 CU/PVC/PVC CABLE FROM SMDB-S-1 TO DB-S-G113x6mm2 CU/PVC/PVC CABLE FROM SMDB-S-1 TO DB-S-G123x6mm2 CU/PVC/PVC CABLE FROM SMDB-S-1 TO DB-S-G133x6mm2 CU/PVC/PVC CABLE FROM SMDB-S-1 TO DB-S-G143x6mm2 CU/PVC/PVC CABLE FROM SMDB-S-1 TO DB-S-G153x6mm2 CU/PVC/PVC CABLE FROM SMDB-S-1 TO DB-S-G163x6mm2 CU/PVC/PVC CABLE FROM SMDB-S-1 TO DB-S-G173x6mm2 CU/PVC/PVC CABLE FROM SMDB-S-1 TO DB-S-G183x6mm2 CU/PVC/PVC CABLE FROM SMDB-S-1 TO DB-S-G193x6mm2 CU/PVC/PVC CABLE FROM SMDB-S-1 TO DB-S-G203x6mm2 CU/PVC/PVC CABLE FROM SMDB-S-1 TO DB-S-G213x6mm2 CU/PVC/PVC CABLE FROM SMDB-S-1 TO DB-S-G223x6mm2 CU/PVC/PVC CABLE FROM SMDB-S-1 TO DB-S-G233x6mm2 CU/PVC/PVC CABLE FROM SMDB-S-1 TO DB-2ND.13x6mm2 CU/PVC/PVC CABLE FROM SMDB-S-2 TO DB-S-G24

温馨提示

  • 1. 本站所有资源如无特殊说明,都需要本地电脑安装OFFICE2007和PDF阅读器。图纸软件为CAD,CAXA,PROE,UG,SolidWorks等.压缩文件请下载最新的WinRAR软件解压。
  • 2. 本站的文档不包含任何第三方提供的附件图纸等,如果需要附件,请联系上传者。文件的所有权益归上传用户所有。
  • 3. 本站RAR压缩包中若带图纸,网页内容里面会有图纸预览,若没有图纸预览就没有图纸。
  • 4. 未经权益所有人同意不得将文件中的内容挪作商业或盈利用途。
  • 5. 人人文库网仅提供信息存储空间,仅对用户上传内容的表现方式做保护处理,对用户上传分享的文档内容本身不做任何修改或编辑,并不能对任何下载内容负责。
  • 6. 下载文件中如有侵权或不适当内容,请与我们联系,我们立即纠正。
  • 7. 本站不保证下载资源的准确性、安全性和完整性, 同时也不承担用户因使用这些下载资源对自己和他人造成任何形式的伤害或损失。

评论

0/150

提交评论