




已阅读5页,还剩4页未读, 继续免费阅读
版权说明:本文档由用户提供并上传,收益归属内容提供方,若内容存在侵权,请进行举报或认领
文档简介
Subscribe to this information POWER5 information Locations model 561 and 570Map location codes to hardware.Mapping physical location codesNote: The known logical location codes for this unit are listed next to the corresponding physical location in the following information. If you are working with a logical location code for this unit and it is not listed in the following information, contact your next level of support.For address information, see Addresses model 561 and 570.Use the following illustrations to help you map a location code to a position on the server. Figure 1. Front view of the system unit. P4-D1 and P4D2 positions are for a 561. The 570 only has the top slot, the P4D1 location.Figure 2. Back view of the system unitFigure 3. Memory module locations on the processor card (Un-P2-Cx)Use the following illustration to map a node location when you are working with a multiple node installation. All of the nodes have the same location codes inside the system unit; only the serial number is different (Utttt.mmm.sssssss-).Figure 4. Multiple node locations with SMP processor cable shownUse the following illustration to help you identify parts of the control panel.Figure 5. A view of the front of the control panel.NumberNameDescription1DisplayDisplays current status of system startup, or diagnostic information in the event of a hardware problem.2Front serial portPort uses RJ-45 connector. Use to plug in external devices at the front of the system unit.3Increment upScrolls the information in the display up.4EnterEnter5Increment downScrolls the information in the display down.8System reset buttonResets the system9Power LEDBlinking - When connected to the power source (System is in standby mode). Solid - When power button has been pressed. Note: There is approximately a 30-second transition period from the time the power-on button is pressed to when the power LED goes from blinking to on solid. During the transition period, you may observe the blinking intervals speed up.10Power-on buttonTurns the system power on and off.11Service processor reset switch (pinhole)Service Personnel Use12Serial number labelDisplays the system serial numberThe following table contains location codes for the parts that make up the server.Attention: After replacing any part on a server or expansion unit, perform Verifying the repair.Table 1. Physical location codesFailing item nameSymbolic failing item namePhysical location codeIdentify LEDLink to part numberFailing item removal and replacement proceduresSystem unit UnNANAFansFan 1Un-A1YesPart assembly diagramsFanFan 2Un-A2YesPart assembly diagramsFanPower suppliesPower supply 1 PWRSPLYUn-E1YesPower partsPower supplyPower supply 2 PWRSPLYUn-E2YesPower partsPower supplyBackplanesInput/output backplane with embedded: RIO Hub/HSL NIC RIO/HSL link Ethernet controller USB controller (AIX or Linux only) IDE bridge (AIX or Linux only) SCSI controllers (2) Logic oscillatorCLCKMODFRPORTHSL_LNKIOBRDGIO_HUBMA_BRDGMABRCFGMASBUSPPCISYSPRI_PCIPIOCARDSI_PHBSIIOADPSICNTRLSYSBKPLSPBUSSTORIOATOPORTUn-P1Yes28DA 7733 (used only with 2.2 GHz processor )I/O backplaneSCSI controller 1 bus 0Un-P1-T12SCSI controller 1 bus 1Un-P1-T13SCSI controller 2 bus 0Un-P1-T14IDE controllerUn-P1-T15Passthru cardProvides connection for VPD card, system ports, and SPCN25F8I/O backplane assemblyNODEPLUn-P1Yes28DA 7733 (used only with 2.2 GHz processor )I/O backplaneSystem processor backplaneMEMBRDUn-P227AESystem backplaneDisk drive backplaneUn-P3Yes28DBDisk drive enclosureSCSI/IDE cardUn-P3-C1180ASCSI-IDE converter cardMedia drive backplaneUn-P4Yes28DCMedia device enclosurePortssystem port 2 (back of system unit)Un-P1-T1NAsystem port 1 (back of system unit)Un-P1-T2NAS1 system port (front of control panel)Un-P1-T2NARack indicator connectorUn-P1-T3NAIntegrated 2-port USB port 1 (AIX or Linux only)Un-P1-T4NAIntegrated 2-port USB port 2 (AIX or Linux only)Un-P1-T5NAIntegrated dual 1 GB Ethernet controller-port 1Un-P1-T6NAIntegrated dual 1 GB Ethernet controller-port 2Un-P1-T7NARIO/HSL left connectorHSL_LNKHSL2HSL2_xxHSLHHSLH_xxUn-P1-T8YesExternal cablesRIO/HSL cables (concurrent)RIO/HSL right connectorHSL_LNKHSL2HSL2_xxHSLHHSLH_xxUn-P1-T9YesExternal cablesRIO/HSL cables (concurrent)System cable connectorUn-P1-T10NAProcessor and processor regulatorProcessor card 1MEMCTLRANYPROCUn-P2-C1YesProcessor partsSystem processorProcessor card 2MEMCTLRANYPROCUn-P2-C2YesProcessor partsSystem processorSMP processor cableUn-P2-C1-T1 and Un-P2-C2-T1Model 561 and 570 cablesSMP processor cableTemperature sensorUn -P2-C1 and Un -P2-C2Processor partsSystem processorVoltage regulator 1Un-P2-C3YesPower partsVoltage regulator card assemblyVoltage regulator 2Un-P2-C4YesPower partsVoltage regulator card assemblyVoltage regulator 3Un-P2-C5YesPower partsVoltage regulator card assemblyVPD cardUn-P1-T10VPD partsVPD cardService processorService processor cardSVCPROCUn-P1-C8Yes28EAService processor assemblyService processor cableI2CBUSUn-P1-T10Model 561 and 570 cablesService processor cableTime-of-day (TOD)Un -P1-C828EAService processor assemblyTime-of-day BatteryTOD_BATUn-P1-C8-E1Power partsService processor time-of-day batteryHMC 1 connectorUn-P1-C8-T1NAHMC 2 connectorUn-P1-C8-T2NASPCN 0 connectorUn-P1-C8-T3NASPCN 1 connectorUn-P1-C8-T4NAAdaptersPCI adapter in slot 1 PIOCARDMASBUSSLOTERRUn-P1-C1YesSystem partsPCI adapterPCI adapter in slot 2PIOCARDMASBUSSLOTERRUn-P1-C2YesSystem partsPCI adapterPCI adapter in slot 3PIOCARDMASBUSSLOTERRUn-P1-C3YesSystem partsPCI adapterPCI adapter in slot 4PIOCARDMASBUSSLOTERRUn-P1-C4YesSystem partsPCI adapterPCI adapter in slot 5PIOCARDMASBUSSLOTERRUn-P1-C5YesSystem partsPCI adapterPCI adapter in slot 6PIOCARDMASBUSSLOTERRUn-P1-C6YesSystem partsPCI adapterRIO/HSL adapter/InfiniBand host channel adapterink SI_CARDSICNTRLHCAUn-P1-C7YesSystem partsRIO/HSL adapter/InfiniBand host channel adapterRIO/HSL adapter connectorHSL_LNKHSL2HSL2_xxHSLHHSLH_xxUn-P1-C7-T1YesExternal cablesRIO/HSL cables (concurrent)RIO/HSL adapter connector HSL_LNKHSL2HSL2_xxHSLHHSLH_xxUn-P1-C7-T2YesExternal cablesRIO/HSL cables (concurrent)Dual channel SCSI RAID enablement cardUn-P1-C95709RAID enablement cardPCI bridge set 1BRDGSETBRDGST1Un-P128DA 7733 (used only with 2.2 GHz processor )I/O backplanePCI bridge set 2BRDGSETBRDGST2Un-P1Un-P1-C1Un-P1-C2Replace the I/O backplane and cards using the removal and replacement procedures corresponding to the locations indicated.PCI bridge set 3BRDGSETBRDGST3Un-P1Un-P1-C3Un-P1-C4Un-P1-C5Un-P1-C6Replace the I/O backplane and cards using the removal and replacement procedures corresponding to the locations indicated.Memory modulesMemory module 1MEMDIMMUn-P2-C1-C1YesMemory partsMemory moduleMemory module 2MEMDIMMUn-P2-C1-C2YesMemory partsMemory moduleMemory module 3MEMDIMMUn-P2-C1-C3YesMemory partsMemory moduleMemory module 4MEMDIMMUn-P2-C1-C4YesMemory partsMemory moduleMemory module 5MEMDIMMUn-P2-C1-C5YesMemory partsMemory moduleMemory module 6MEMDIMMUn-P2-C1-C6YesMemory partsMemory moduleMemory module 7MEMDIMMUn-P2-C1-C7YesMemory partsMemory moduleMemory module 8MEMDIMMUn-P2-C1-C8YesMemory partsMemory moduleMemory module 1MEMDIMMUn-P2-C2-C1YesMemory partsMemory moduleMemory module 2MEMDIMMUn-P2-C2-C2YesMemory partsMemory moduleMemory module 3MEMDIMMUn-P2-C2-C3YesMemory partsMemory moduleMemory module 4MEMDIMMUn-P2-C2-C4YesMemory partsMemory moduleMemory module 5MEMDIMMUn-P2-C2-C5YesMemory partsMemory moduleMemory module 6MEMDIMMUn-P2-C2-C6YesMemory partsMemory moduleMemory module 7MEMDIMMUn-P2-C2-C7YesMemory partsMemory moduleMemory module 8MEMDIMMUn-P2-C2-C8YesMemory partsMemory moduleNote: First quad of memory modules is plugged into memory module slots P2-Cx-C1, P2-Cx-C3, P2-Cx-C6, and P2-Cx-C8. Second quad of memory modules is plugged into memory module slots P2-Cx-C2, P2-Cx-C4, P2-Cx-C5, and P2-Cx-C7.Device physical locationsDisk drive 1Un-P3-D1 (logical location with RAID card Un-P1-T13-L5-L0, logical location without RAID card Un-P1-T14-L5-L0)YesDisk unit partsDisk driveDisk drive 2Un-P3-D2 (logical location with RAID card Un-P1-T13-L4-L0, logical location without RAID card Un-P1-T14-L4-L0)YesDisk unit partsDisk driveDisk drive 3Un-P3-D3 (logical location with RAID card Un-P1-T13-L3-L0, logical location without RAID card Un-P1-T14-L3-L0)YesDisk unit partsDisk driveDisk drive 4Un-P3-D4 (logical location with RAID card Un-P1-T12-L5-L0, logical location without RAID card Un-P1-T12-L5-L0)YesDisk unit partsDisk driveDisk drive 5Un-P3-D5 (logical location with RAID card Un-P1-T12-L4-L0, logical location without RAID card Un-P1-T12-L4-L0)YesDisk unit partsDisk driveDisk drive 6Un-P3-D6 (logical location with RAID card Un-P1-T12-L3-L0, logical location without RAID card Un-P1-T12-L3-L0)YesDisk unit partsDisk driveIDE drive 1Un-P4-D1YesRemovable media device partsMedia deviceIDE drive 2 for 570Un-P4-D2YesRemovable media device partsMedia deviceControl panelControl panel (bottom media bay)Un -D128D4Control panelServer firmwareServer firmwareUn-Y1Input/output adapter (IOA) assignment rules for i5/OSThe following table provides information necessary to identify the input/output processor (IOP) to which IOAs are assigned. The left column indicates the bridge set in which IOA assignment is allowed. Use the right column to determine the IOP to which an IOA is assigned. The first position in the list must be an IOP. The remaining positions might be IOPs or IOAs. IOAs are assigned to the first IOP located to their left in the list. Although IOAs can be manually reassigned using system service tools (SST)/dedicated service tools (DST), the IOA assignments return to the default order after each initial program load (IPL). Multi-adapter bridge domain / Peripheral Component Interconnect (PCI) bridge set IOA assignment rules Adapters embedded in -P1 planar (no IOP)Embedded SCSI, embedded EthernetC1 - C2Embedded SCSI, C2C3 - C6 C4, C5, C6Parent topic: Finding part locationsSubscribe to this information POWER5 information Addresses model 561 and 570Find part locations using location codes.Use the address to find the location for the 9116-561, 9406-570, and 9117-570 models. Then go to Locations model 561 and 570 to find additional information.Table 1. IOP, IOA, and device address information for the primary unitPhysical location codePossible failing itemDSA (BBBBCcbb) Unit addressIOA and device DSAs do not conform to the following rules if the IOA is manually reassigned after IPL.Un-P1Embedded Ethernet0001-24-00E6FFFFFFUn-P1 (and UN-P1-C9 if RAID enablement card is installed)Embedded SCSI0003-20-002FFFFFFFUn-P1-C1IOP0003-20-00FFFFFFFFUn-P1-C2Communications or Workstation IOA0003-20-00E6FFFFFFUn-P1-C3IOP0002-20-00FFFFFFFFUn-P1-C4Storage IOA0002-20-002FFFFFFFUn-P1-C4Communications or Workstation IOA0002-20-00E2FFFFFFUn-P1-C5IOP0002-24-00FFFFFFFFUn-P1-C5Storage IOA0002-20-004FFFFFFFUn-P1-C5Communications or Workstation IOA0002-20-00E4FFFFFFUn-P1-C6Storage IOAThe IOA has the same DSA as the first IOP found in the following list: C5, C4, C3.6FFFFFFFUn-P1-C6Communications or Workstation IOAThe IOA has the same DSA as the first IOP found in the following list: C5, C4, C3.E6FFFFFFUn-P3-D1Disk unit0003-20-00210200FFUn-P3-D2Disk unit0003-20-00210300FFUn-P3-D3Disk unit0003-20-00210400FFUn-P3-D4Disk unit0003-20-00200200FFUn-P3-D5Disk unit0003-20-00200300FFUn-P3-D6Disk unit0003-20-00200400FFUn-P4-D1IDE drive 1 0003-20-00200600FFUn-P4-D2IDE drive 2 Table 2. IOP, IOA, and device address information for the secondary unitsPhysical location codeP
温馨提示
- 1. 本站所有资源如无特殊说明,都需要本地电脑安装OFFICE2007和PDF阅读器。图纸软件为CAD,CAXA,PROE,UG,SolidWorks等.压缩文件请下载最新的WinRAR软件解压。
- 2. 本站的文档不包含任何第三方提供的附件图纸等,如果需要附件,请联系上传者。文件的所有权益归上传用户所有。
- 3. 本站RAR压缩包中若带图纸,网页内容里面会有图纸预览,若没有图纸预览就没有图纸。
- 4. 未经权益所有人同意不得将文件中的内容挪作商业或盈利用途。
- 5. 人人文库网仅提供信息存储空间,仅对用户上传内容的表现方式做保护处理,对用户上传分享的文档内容本身不做任何修改或编辑,并不能对任何下载内容负责。
- 6. 下载文件中如有侵权或不适当内容,请与我们联系,我们立即纠正。
- 7. 本站不保证下载资源的准确性、安全性和完整性, 同时也不承担用户因使用这些下载资源对自己和他人造成任何形式的伤害或损失。
最新文档
- 新质生产力专家观点
- 武术课教学试讲课件
- 2025年河南省商丘市事业单位工勤技能考试题库及答案
- 工程项目管理进度控制标准模板
- 年产32500台工业信号转换器项目可行性研究报告
- 年产1.8万套SoC芯片项目可行性研究报告
- 年产3万套诊断标定软件项目可行性研究报告
- 年产12万吨己二酸硝酸氧化反应器项目可行性研究报告
- 2025年物业管理高级考试模拟试题及解析
- 2025年爆款流出酒店业必-备接待岗位招聘笔试试题解析
- 2026高考英语 写作-倡议信 复习课件
- 2025广东广州市从化区社区专职人员招聘33人笔试参考题库附答案解析
- 建材买卖(橱柜订购类)合同协议书范本
- 托管老师岗前培训
- (正式版)HGT 6313-2024 化工园区智慧化评价导则
- 建筑施工应急处置明白卡
- 环境污染刑事案件司法解释学习课件
- 信息技术教学德育融合
- 护理品管圈QCC之提高手术物品清点规范执行率
- 高尔夫基础培训ppt课件
- 暴雨产流计算(推理公式_四川省)
评论
0/150
提交评论