基于PLC的电梯控制系统设计中英文翻译_第1页
基于PLC的电梯控制系统设计中英文翻译_第2页
基于PLC的电梯控制系统设计中英文翻译_第3页
基于PLC的电梯控制系统设计中英文翻译_第4页
基于PLC的电梯控制系统设计中英文翻译_第5页
已阅读5页,还剩4页未读 继续免费阅读

下载本文档

版权说明:本文档由用户提供并上传,收益归属内容提供方,若内容存在侵权,请进行举报或认领

文档简介

Elevator System Based on PLC Composed by the order of relay control system is a realization of the first elevator control method However to enter the nineties with the development of science and technology and the widespread application of computer technology the safety of elevators reliability of the increasingly high demand on the relay control weaknesses are becoming evident Elevator control system relays the failure rate high greatly reduces the reliability and safety of elevators and escalators stopped often to take with the staff about the inconvenience and fear And the event rather than taking the lift or squat at the end of the lift will not only cause damage to mechanical components but also personal accident may occur Programmable Logic Controller PLC is the first order logic control in accordance with the needs of developed specifically for industrial environment applications to operate the electronic digital computing device Given its advantages at present the relay control the lift has been gradually replaced by PLC control At the same time AC variable frequency motor speed control technology the way the lift drag speed has been a gradual transition form DC to AC frequency converter Thus PLC control technology increases VVVF Elevator modern technology has become a hot industry 1 PLC elevator control advantages 1 Used in elevator control PLC with so ware for automatic control of lift operation reliability greatly increased 2 Layer was removed and majority of the relay the control system structure is simple simplify the external circuit 3 PLC can be a variety of complex control system easy to add or change control functions 4 PLC can be automated fault detection and alarm display to improve the operation of security and ease of maintenance 5 For the group control the allocation and management and improve the efficiency of elevator operation 6 Do not need to change the control scheme changes when the hardware connection 2 VVVF elevator control characteristics 1 With the power electronics microelectronics and computer technology to control the rapid development of technology communication technology VVVF also a very rapid rate AC variable frequency motor speed control technology is the power to improve the process in order to improve product quality and improving the environment and promoting technological progress as a primary means Frequency of its excellent performance and the speed brake from a smooth performance high efficiency high power factor and power saving of a broad scope of application and many other advantages of being at home and abroad recognized as the most promising approach speed Exchange characteristics of VVVF Elevator 1 low energy consumption 2 low load circuit the re emergency power supply device of small In the acceleration stage the required start up current of less than 2 5 times the rated current Peak starting current and time is short Since the starting current is drastically reduced so power consumption and power supply cable diameter can be reduced a lot Required for emergency power supply devices are also relatively small size 3 high reliability and long service life 4 good comfort Elevator operation is best to follow the speed curve of a given operation Their characteristics can be adapted to human feelings and to ensure that noise operation smooth brake Ping layer and high precision 5 stable noise free 6 In the car the engine room and adjacent areas to ensure that noise Because their systems use a high clock frequency Always produce a true sine wave power supply current yet Motor torque ripple does not appear Therefore to eliminate vibration and noise 3 Elevator control technology The so called elevator control technology refers to the elevator drive system and electrical control system of automatic control 70 as the 20th century in China s elevator were marked by the exchange of two speed elevator Its speed is used to change the elevator traction motor of the very few two or mute level approach to the number of windings very few of them as high speed winding of the winding a very few number of windings as the 2 low speed winding Windings for high speed elevator speed start up and running low speed windings for braking and the maintenance of elevators The early 80s VVVF inverter controlled variable lift system available It uses AC motor drivers are able to reach the level of DC motor control the speed of the current has reached 6 m sec Its small size light weight high efficiency energy saving inc1uding the past almost all the advantages of the lift Is the latest elevator drive system Operation in vertical lift there is also the starting point of the terminus station For more than three story elevator buildings the starting point of the terminal stations and stops between the had not the starting point for these stations at the first floor of the terminal located at the highest floor Starting point in the first floor of the station known as base stations known as the starting point at both ends of the terminal stations and stations at both ends of intermediate stops between stations Outside the station has a call box box set are used by staff for elevator call button or touch the call button the general ends of the lift stations in the call box on the Settings button or touch of a button 1iddle layer of the station set up the call box button or touch button 2 No drivers for the control of elevators at various stations are set up calls me on a button or touch button Elevator car and the internal settings except for debris elevator to manipulate me Control box switch on the handle or set up stations and the corresponding layer of buttons or touch button control box on the touch control button or command button or touch the city button Outside the command button or touch button issue as the signal outside the command signal within the command button or touch button issue within the signal as a command signal 80 In the mid 20th century the touch button has been replaced by micro button As the elevator call box outside the base station in addition to set up a call button or touch button but a1so set a key switch in order to work the elevator clearance Drivers or management staff to open the elevator to the base station can wriggle through a dedicated key to the key switch Close the elevator in place to autocratically cut off the elevator control power supply or power supply 4 PLC Control Elevator Design With the continuous development of urban construction the increasing high rise buildings elevators and life in the national economy has a broad application Elevator high rise buildings as a means of transport in the vertical run of daily life have been inextricably 3 linked with people In fact the lift is based on external call control signals as well as the laws of their own such as running and the cal1 is random the lift is actually a man machine interactive control system simple to use control or logic control order can not meet the control requirement and therefore elevator control system uses a random control logic Elevator control is current1y generally used in two ways first the use of computer as a signal control unit the completion of the lift signal acquisition operation and function of the se to achieve the lift and set the autocratic scheduling function to run the election drag the control from inverter to complete the second control mode with programmable logic controller PLC to replace the computer control signal sets the election From the control and performance these two types of methods and there is no significant difference Most of the domestic manufacturers to choose the second approach because the smaller scale of production there design and manufacture of high cost of computer control devices and PLC high reliabi1ity convenient and flexible program design anti interference ability stable and reliable operation of the characteristics of Therefore the elevator control system is now widely used to realize programmable control 5 Lift control system Lift control system is used to manipulate each control process by managing such commands as running direction car call landing call load signal landing indication safety protection Lifts in different applications have different load speed and drive control modes Lifts in same application may also have different control mode Whatever control mode is adopted the objective is the same to be specific according to car call and landing call lift control system will execute automatic logic judgment to determine which lift will receive signal which direction lift will run towards and complete programmed control objective through electrical automatic system based on command Types of lift control system Control system development chronicle indicates that there has appeared many control modes such as such as relay control PLC single computer control multiple computer control Prevailing in different era these control modes are still employed in lifts now due to massive integrated circuit and computer technology development PLC control system 4 As abbreviation of programmable logic controller PLC is an electronic system featuring digital computation It adopts programmable EPROM to execute logic computation order control timing number counting arithmetic computation besides it can input and output through digital or analogy modes The mechanism of PLC control is as follows input of PLC includes such command signals as power key to home landing car call landing call various safety switches position signal while output of PLC includes contactor relay indicators of car landings and communication unitary indicators inside car and switch position signal are input to PC while other executing com Programming principle is determined by lift control mode Programming can either be made according to relay logic control circuit or individually in different phases according to lift control functions after completely separating from relay control circuit Based on the ready made control circuit the former is simple and easy to master while the latter involves less programs by integrating programs of small function Used in lift control system PLC ha

温馨提示

  • 1. 本站所有资源如无特殊说明,都需要本地电脑安装OFFICE2007和PDF阅读器。图纸软件为CAD,CAXA,PROE,UG,SolidWorks等.压缩文件请下载最新的WinRAR软件解压。
  • 2. 本站的文档不包含任何第三方提供的附件图纸等,如果需要附件,请联系上传者。文件的所有权益归上传用户所有。
  • 3. 本站RAR压缩包中若带图纸,网页内容里面会有图纸预览,若没有图纸预览就没有图纸。
  • 4. 未经权益所有人同意不得将文件中的内容挪作商业或盈利用途。
  • 5. 人人文库网仅提供信息存储空间,仅对用户上传内容的表现方式做保护处理,对用户上传分享的文档内容本身不做任何修改或编辑,并不能对任何下载内容负责。
  • 6. 下载文件中如有侵权或不适当内容,请与我们联系,我们立即纠正。
  • 7. 本站不保证下载资源的准确性、安全性和完整性, 同时也不承担用户因使用这些下载资源对自己和他人造成任何形式的伤害或损失。

评论

0/150

提交评论