




已阅读5页,还剩3页未读, 继续免费阅读
版权说明:本文档由用户提供并上传,收益归属内容提供方,若内容存在侵权,请进行举报或认领
文档简介
MVA Method Short Circuit CalculationA Short Circuit Study is an important tool in determining the ratings of electrical equipment to be installed in a project. It is also used as a basis in setting protection devices. Computer software simplifies this process however, in cases where it is not available, alternative methods should be used. The per-unit and ohmic method are very tedious manual calculation. These hand calculations are very prone to errors due to so many conversion required. In per unit, base conversion is a normal part of the calculation method while in ohmic method, complex entities conversion.The easy way to do hand calculation is the MVA method.In this example, we shall be presenting a short circuit study of a power system. Motors are are already lumped with ratings 37kW and below assigned an impedance value of 25% while larger motors are 17%. A 4MVA generator is also included into the system to augment the utility.Figure 1Utility: 33KV, 250 MVAsc (the 250MVA in this example is just assumed. Ask your utility for the actual fault level at your point of connection)Transformer 1: 10 MVA, 33/11KV, 9% Z11KV BusGenerator: 4MVA, Xd = 0.113Transformer 2: 5 MVA, 11/6.6KV, 7% ZMotor 1: 5MVA (Lumped), 17% Z6.6KV BusTransformer 3: 2 MVA, 6.6KV/400V, 6% ZMotor 3: 6.8 MVA (Lumped), 17% Z400V BusMotor 4: 300 KVA (Lumped), 17% ZMotor 5: 596 KVA (Lumped), 25% ZIn the event of a short circuit, the sources of short circuit current are1. Utility2. Generators3. MotorsStatic loads such as heaters and lighting do not contribute to short circuit.The Equivalent MVA are:Transformers and MotorsGeneratorsCables and ReactorsIn Figure 1, I have calculated the Equivalent MVAs of each equipment, writing it below the ratings.Figure 2Utility: MVAsc = 250MVATransformer 1: MVAsc = 10 / 0.09 = 111.11 MVA11KV BusGenerator: MVAsc = 4 / 0.113 = 35.4 MVATransnformer 2: MVAsc = 5 / 0.07 = 71.43 MVAMotor 1: MVAsc = 5 / 0.17 = 29.41 MVA6.6KV BusTransformer 3: MVAsc = 2 / 0.06 = 33.33 MVAMotor 3: MVAsc = 6.8 / 0.17 = 40 MVA400V BusMotor 4: MVAsc = 0.3 / 0.17 = 1.76 MVAMotor 5: MVAsc = 0.596 / 0.25 = 2.38 MVAFigure 3Upstream ContributionStarting from the utility, combine MVAs writing each one above the arrows.At Transformer 1:MVAsc 33KV = 250 MVAMVAsc 11KV = 1/ (1 / 250 + 1 /111.11) = 76.87 MVAAt Transformer 2:MVAsc 11KV = 76.87 + 35.4 + 29.41 = 141.68 MVAMVAsc 6.6KV = 1/ (1 / 141.68 + 1 / 71.43) = 47.49 MVAAt Transformer 3:MVAsc 6.6KV = 47.49 + 40 = 87.49 MVAMVAsc 400V = 1/ (1 / 87.49 + 1 / 33.33) = 24.14 MVAAt 400V MotorsMotor 3: MVAsc = 24.14 x 1.76 / ( 1.76 + 2.38 ) = 10.26 MVAMotor 4: MVAsc = 24.14 x 2.38 / ( 1.76 + 2.38 ) = 13.88 MVADownstream ContributionStarting from the bottom (400V Bus), I combined MVAs writing each one below the arrows. In this bus, the motor contribution to short circuit is the sum of the MVAs of the lumped motors Motor 3 and Motor 4.At Transformer 3:MVAsc 400V = 1.76 + 2.38 = 4.14 MVAMVAsc 6.6KV = 1/ (1 / 4.14 + 1 / 33.33) = 3.68 MVAAt Transformer 2:MVAsc 6.6KV = 3.68 + 40 = 43.68 MVAMVAsc 11KV = 1/ (1 / 43.68 + 1 / 71.43) = 27.11 MVAAt Transformer 1:MVAsc 11KV = 27.11 + 29.41 + 35.4 = 91.92 MVANote: Two downstream plus the generator contribution.MVAsc 33KV = 1/ (1 / 91.92 + 1 /111.11) = 50.3 MVATo determine the Faults Current at any bus on the power system, add the MVA values above and below the arrows. The sum should be the same on any branch.Example:11 KV Bus:From Transformer 1: MVAsc = 76.87 + 91.92 = 168.79 MVAFrom Generator : MVAsc = 35.4 + 133.39 = 168.79 MVAFrom Transformer 2: MVAsc = 141.68 + 27.11 = 168.79MVAFrom Motor 1: MVAsc = 139.38 + 29.41 = 168.79 MVAThis is a check that we have done the correct calculation.Ifault 11KV = 168.79 / (1.732 x 11) = 8.86 kAAll we have done above are three phase faults, you may ask, how about single phase faults?For single phase faults, positive sequence, negative sequence and zero sequence impedances need to be calculated.If = 3 (I1 + I2 + I0)Examining the circuit in Figure 1, at the 400V Bus, on Transformer 3 contributes to the zero sequence current.For transformers, the negative sequence and zero sequence impedance are equal to the positive sequence impedance.Z1 = Z2 = Z0 orMVA1 = MVA2 = MVA0At the 400V Bus1 / MVAsc =1/3 (1 / MVAsc1 + 1 / MVAsc2 + 1 / MVAsc0)1 / MVAsc = 1/3 (1 / 28.28 + 1 / 28.28 + 1 / 33.33 )MVAsc =3 x 9.93 = 29.79 MVAIf = 29.79 / (1.732 x 0.4) = 43 kAAt 6.6KV Bus1 / MVAsc = 1/3 (1 / MVAsc1 + 1 / MVAsc2 + 1 / MVAsc0)1 / MVAsc = 1/3 (1 / 91.17 + 1 / 91.17 + 1 / 71.43)MVAsc = 3 x 27.83 = 83.49 MVAIf = 83.49 / (1.732 x 6.6) = 7.26 kAConclusion:This example illustrates that using the MVA Method of Short Circuit Calculation, it will be very easy to calculate the fault cur
温馨提示
- 1. 本站所有资源如无特殊说明,都需要本地电脑安装OFFICE2007和PDF阅读器。图纸软件为CAD,CAXA,PROE,UG,SolidWorks等.压缩文件请下载最新的WinRAR软件解压。
- 2. 本站的文档不包含任何第三方提供的附件图纸等,如果需要附件,请联系上传者。文件的所有权益归上传用户所有。
- 3. 本站RAR压缩包中若带图纸,网页内容里面会有图纸预览,若没有图纸预览就没有图纸。
- 4. 未经权益所有人同意不得将文件中的内容挪作商业或盈利用途。
- 5. 人人文库网仅提供信息存储空间,仅对用户上传内容的表现方式做保护处理,对用户上传分享的文档内容本身不做任何修改或编辑,并不能对任何下载内容负责。
- 6. 下载文件中如有侵权或不适当内容,请与我们联系,我们立即纠正。
- 7. 本站不保证下载资源的准确性、安全性和完整性, 同时也不承担用户因使用这些下载资源对自己和他人造成任何形式的伤害或损失。
最新文档
- 快速办理案件培训课件
- 关于体检销售培训课件
- 药厂安全生产知识培训课件
- 2026届高三英语 复习语法定语从句课件
- 内部沟通协作与会议管理工具
- 产品缺陷预防与改进方案工具箱
- 药厂QC培训课件
- 企业知识产权保护策略与操作流程模板
- 食管吻合口瘘的护理
- 软件销售培训课件
- SC/T 9010-2000渔港总体设计规范
- 乡镇应急信息报送制度
- 实验动物遗传学及质量控制课件
- 认识电影走进电影课件
- 新能源概论全解课件
- 服务器虚拟化资源调研表
- 2022年杭州市中小学教师职称考试卷
- 《中国公民科学素质基准》题库500题(精品)
- 第三章药物治疗的基本过程
- Minitab教程源数据及六西格玛绿带手册相关工作表 鱼骨图
- 大客户销售技巧与客户关系管理(共94页).ppt
评论
0/150
提交评论