




免费预览已结束,剩余41页可下载查看
下载本文档
版权说明:本文档由用户提供并上传,收益归属内容提供方,若内容存在侵权,请进行举报或认领
文档简介
Page 4 of 46 Report No.: CTL11098586-S-LShenzhen CTL Electromagnetic Technology Co., Ltd.Tel: +86-755-89486194 Fax: +86-755-89486187TEST REPORTIEC 60884-1:2002 (Third edition)+A1:2006 IEC 60 884-2-2:2006 Plugs and socket-outlets for household and similar purposes Part 1: General requirements Part 2: Particular requirements for socket-outlets for appliancesReport Reference No.:CTL11098586-S-LTested by (name + signature):Tony LiSupervised by (name + signature):Hedy HongApproved by (name + signature):Tracy QiDate of issue:2011-09-29Testing Laboratory Name:Shenzhen CTL Electromagnetic Technology Co., Ltd.Address:Zone B, 4/F, Block 20, Guangqian Industrial Park, Longzhu Road,Nanshan,Shenzhen 518055 China.Testing location:Same as aboveApplicants name:WINTONE TRADING C.C.Address:UNIT B07, ROUTE 24 BUSINESS PARK, HERMAN ST., MEADOWDALE, GERMISTON, JOHANNESBURG SOUTH AFRICA.Test specification:Standard:IEC 60 884-2-2:2006 used in conjunction with IEC 60884-1:2002 (Third edition)+A1:2006 Test procedure:CB / CCANon-standard test method.:N/ATest Report Form No.:IEC60884_2_2BTest Report Form(s) Originator:SGS Fimko LtdMaster TRF:Dated 2007-06Test item description:SOCKETSTrade Mark:GOLDSTONEManufacturer:Minyu Limited168#, Tapu East Road, Siming area, Xiamen, Fujian.Model/Type reference:GS12-1Ratings:250V, 16ACopy of marking plateGOLDSTONE Name: SOCKETSModel: GS12-1Input: 250V, 16A Made In ChinaSummary of testing:Tested according to national requirements for the following countries: All CENELEC members as listed in IEC 60 884-2-2:2006 The tests of SOCKETS (model: GS12-1) was carried out under the most unfavorable combination within the manufacturers operating specifications as followings:-supply voltage, 250 V AC from AC power source-operating temperature, Max. ambient temperature 25C declared by the client-operating mode: continuousTest item particulars:Equipment mobility: movable hand-held transportable stationary for building-in direct plug-inConnection to the mains: pluggable equipment type A type B permanentconnection detachable power supply cord non-detachable power supply cordnot directly connected to the mainsOperating condition: continuous rated operating / resting time: Access location : operator accessible restricted access locationOver voltage category (OVC) : OVC I OVC II OVC III OVC IV other: Mains supply tolerance (%) or absolute mains supply values :AC power supplyTested for IT power systems : Yes NoIT testing, phase-phase voltage (V) :N/APollution degree (PD) : PD 1 PD 2 PD 3IP protection class :IPX0Altitude during operation (m) :2000Altitude of test laboratory (m) :10Mass of equipment (kg) :0.076Possible test case verdicts:- test case does not apply to the test object:N/A- test object does meet the requirement:P (Pass)- test object does not meet the requirement:F (Fail)Testing:Date of receipt of test item:2011-09-22Date(s) of performance of tests:2011-09-29General remarks:The test results presented in this report relate only to the object tested.This report shall not be reproduced, except in full, without the written approval of the Issuing testing laboratory.(See Enclosure #) refers to additional information appended to the report.(See appended table) refers to a table appended to the report.Note: This TRF includes EN Group Differences together with National Differences and Special National Conditions, if any. All Differences are located in the Appendix to the main body of this TRF.Throughout this report a comma (point) is used as the decimal separator.General product information:The equipment is a SOCKETS, powered by mains, for indoor use only. The manufacturer specified maximum ambient temperature as 25.1.1.2 - Additional requirements:Exposure to extreme temperatures, excessive dust, moisture or vibration; to flammable gases; to corrosive or explosive atmospheres:This equipment is intended to operate in a normal environment.Electromedical equipment connected to the patient:This equipment is not an electromedical equipment intended to be physically connected to a patient.This equipment is intended to operate in a normal environment.Page 44 of 46Report No.: CTL11098586-S-LIEC 60884-2-2:2006ClauseRequirementRemarkResult8 MARKING 8.1 Accessories marked as follows: P- rated current (A) . : 16A P - rated voltage (V) . : 250V P - symbol for nature of supply . : P - manufacturers or responsible vendors name . : GOLDSTONEP - type reference . : GS12-1P - symbol for degree of protection (first digit) . : 2 P - symbol for degree of protection (second digit) . : 0 P Socket-outlets with screwless terminals marked with the following: N- the length of insulation to be removed . : N - an indication of the suitability to accept rigid conductors only (if any) . :N- socket-outlets for appliances: provided with flat, quick-connect terminations and screw-type or screwless terminals supplied with an instruction sheet, attached to the smallest packaging unit, informing the user that flat, quick-connect terminations shall not be used for fixed installations (See IEC 60884-2-2 sub-clause 7.1) . : N 8.2 Symbols used: as required in the standard P Marking for the nature of supply placed next to the marking for rated current and rated voltage 250V 16A P 8.3 Marking of fixed socket-outlets placed on the main part: N- rated current, rated voltage and nature of supply N - identification mark of the manufacturer or of the responsible vendor N - length of insulation to be removed, if any N - type reference N Cover plates necessary for safety purposes and intended to be sold separately: marked with the manufacturers or responsible vendors name and type reference N IP code, if applicable: marked so as to be easily discernible N Fixed socket-outlets classified according to item b) of 7.2.5: identified by a triangle visible after installation unless they have an interface configuration different from that used in normal circuits . : N 8.4 Plugs and portable socket-outlets: marking specified in 8.1, other than the type reference, easily discernible Easily discernible P Plugs and portable socket-outlets for equipment of class II not marked with the symbol for class II construction Class I N 8.5 Neutral terminals: N . : Have ”N” the mark P Earthing terminals: earth symbol . : P Markings not placed on screws or other easily removable parts Pass muster P Terminals for conductors not forming part of the main function of the socket-outlet: N- clearly identified unless their purpose is self evident, or N - indicated in a wiring diagram fixed to the accessory N Identification of such terminals may be achieved by: N- their being marked with graphical symbols according to IEC 60417-2 or colours and/or alphanumeric system, or N - their being marked with their physical dimensions or relative location N 8.6 Surface-type mounting boxes forming an integral part of socket-outlets having IP20: IP code marked on the outside of its associated enclosure so as to be easily discernible IP2X N 8.7 Indication of which position or with which special provision the declared IP of flush-type and semi-flush-type fixed socket-outlets having IPX0 is ensured IPX0 N 8.8 Marking durable and easily legible. Test: 15 s with water and 15 s with petroleum spirit Easily legible and durable P 9 CHECKING OF DIMENSIONS 9.1 Accessories and surface-type mounting boxes comply with the appropriate standard sheets Accord with requirement of standard P Insertion of plugs into fixed or portable socket-outlets ensured by their compliance with the relevant standard sheets Pass muster P Compliance checked by measurement and by means of gauges with manufacturing tolerances as shown in table 2 Comply with the requirements P 9.2 It is not possible to engage a plug with: - a socket-outlet having a higher voltage rating or a lower current rating N - a socket-outlet with a different number of live poles (exception admitted provided that no dangerous situation can arise) Pass muster P - a socket-outlet with earthing contact (plug for class 0 equipment) P Engagement of a plug for class 0 or class I equipment with a socket-outlet designed to accept plugs for class II equipment, not possible P Impossibility of insertion checked by applying a gauge, for 1 min, with a force of: N- 150 N (rated current 16A) P - 250 N (rated current 16A) N Accessories with elastomeric or thermoplastic material: test carried out at (35 2) C P 9.3 Deviations from standard sheets made only if they provide technical advantage and do not affect the purpose and safety of accessories complying with standard sheet P 10 PROTECTION AGAINST ELECTRIC SHOCK 10.1 Socket-outlets: live parts not accessible P Live parts of plugs: not accessible when the plug is in partial or complete engagement with a socket-outlet Pass muster P Test with test probe B of IEC 61032 Comply with the requirements P Accessories with elastomeric or thermoplastic material: additional test carried out at (35 2) C with test probe 11 of IEC 61032 (75 N for 1 min) Pass muster Comply with the requirements P During the test: accessories not deform and no live parts accessible Dont deform and dont be accessible P Plugs and portable socket-outlets pressed with a force of 150 N for 5 min as shown in figure 8: specimens not show deformation No danger Pass muster P 10.2 Accessible parts (with exception of small screws and the like for fixing bases and covers or cover plates): made of insulating material P Cover or cover plates of fixed socket-outlets and accessible parts of plugs and portable socket-outlets: made of metal if the requirements of 10.2.1 or 10.2.2 are fulfilled N 10.2.1 Metal covers or cover plates protected by supplementary insulation made by insulating linings or insulating barriers N Insulating linings or insulating barriers cannot be removed without being permanently damaged N Insulating linings or insulating barriers cannot be replaced in an incorrect position and, if they are omitted, accessories are rendered inoperable or manifestly incomplete N There is no risk of accidental contact between live parts and metal covers or cover plates N 10.2.2 Metal covers or cover plates automatically connected, through a low-resistance connection, to the earth during fixing N 10.3 Contact between a pin of a plug and a live socket-contact of a socket-outlet not possible while any other pin is accessible P Compliance checked by manual test and by means of gauges with tolerances as specified in table 2 P Accessories with elastomeric or thermoplastic material: test carried out at (35 2) C Pass muster P Socket-outlets with enclosure or bodies of rubber or polyvinyl chloride: test carried out with a force of 75 N for 1 min Pass muster P Fixed socket-outlets provided with metal covers or cover plates: clearance of at least 2 mm required between a pin and a socket-contact when another pin(s) is (are) in contact with the metal covers or cover plates . : N 10.4 External parts of plugs made of insulating material P Overall dimensions of rings around pins not exceed 8 mm concentric with respect to the pin P 10.5 Shuttered socket-outlets: live parts not accessible, without a plug in engagement, with the gauges shown in figure 9 and 10 N Live contacts automatically screened when the plug is withdrawn N Means cannot easily be operated by anything other than a plug and not depend upon parts which are liable to be lost N Gauge of figure 9, applied to the entry holes corresponding to live contacts with a force of 20 N, for approximately 5 s, successively in three directions, does not touch live parts N Steel gauge of figure 10, applied to the entry holes corresponding to live contacts with a force of 1 N for approximately 5 s, in three directions, does not touch live parts N Accessories with elastomeric or thermoplastic material: test carried out at (35 2) C N 10.6 Earthing contacts of a socket-outlet designed that they cannot be deformed by the insertion of a plug P Test plug inserted into the socket-outlet with a force of 150 N for 1 min PAfter this test: socket-outlet still comply with the requirements of clause 9 Pass muster P 10.7 Socket-outlet with increased protection: live parts not accessible P Test wire of 1 mm diameter (figure 10) applied with a force of 1 N on all accessible surfaces does not touch live parts P Accessories with elastomeric or thermoplastic material: test carried out at (35 2) C P 11 PROVISION FOR EARTHING 11.1 Earth connection made before the current-carrying contacts of the plug become live Pass muster P Current-carrying pins are separated before the earth connection is broken Pass muster P 11.2 Earthing terminals of rewirable accessories comply with clause 12 N Earthing terminals of the same size as the corresponding terminals for the supply conductors N Earthing terminals of rewirable accessories: internal NAdditional external earthing terminal of fixed socket-outlets of size suitable for conductors of at least 6 mm2 . : N Earthing terminals of fixed socket-outlets: fixed to the base or to a part reliably fixed to the base N Earthing contacts of fixed socket-outlets: N - fixed to the base, or N - fixed to the cover (reliably connected to the earthing terminals; contact pieces silver plated or with adequate protection) N Parts of earthing circuit in one piece or reliably connected by riveting, welding, or the like N 11.3 Accessible metal parts of fixed socket-outlets: permanently and reliably connected to the earthing terminal N 11.4 Socket-outlets, having an IPX0, with enclosure of insulating material and more than one cable inlet, provided with: N - an internal fixed earthing terminal, or N - adequate space for a floating terminal (test connection using the type of terminal specified by the manufacturer), unless N - earthing terminal of socket-outlet itself allows the connection of an incoming and an outgoing earthing conductor N 11.5 Connection between earthing terminal and accessible metal parts: of low resistance P Test: P Test current equal to 1,5 times the rated current or 25 A (A) . : Test current:25 A P Resistance not exceed 0,05 () . : 0,007 P 11.6 Fixed socket-outlets according to item b) of 7.2.5: earthing socket contact and its terminal electrically separated from any metal mounting means or other exposed conductive parts which may be connected to the protective earthing circuit of the installation N 12 TERMINALS AND TERMINATIONS P All the test on terminals, with the exception of the tests of 12.3 11 and 12.3.12, made after the test of clause 16 Pass muster Comply with the requirements P 12.1 General P 12.1.1 Rewirable fixed socket-outlets provided with screw-type terminals or with screwless terminals . : N Socket-outlets for appliances provided with screw-type terminals, screwless terminals and/or male tabs of flat, quick-connect terminations (See IEC 60884-22 sub-clause 11.1.1) . : P Rewirable plugs and portable socket-outlets provided with terminals with screw clamping . : P Pre-soldered flexible conductors used: pre-soldered area outside the clamp area of screw-type terminals P Clamping means of terminals: not serve to fix any other components P 12.1.2 Non-rewirable accessories provided with soldered, welded, crimped or equally effective permanent connections (termination) . : P Screwed or snap-on connections not used N Connections made by crimping a pre-soldered flexible conductor not permitted N 12.2 Terminals with screw clamping for external copper conductors N 12.2.1 Accessories provided
温馨提示
- 1. 本站所有资源如无特殊说明,都需要本地电脑安装OFFICE2007和PDF阅读器。图纸软件为CAD,CAXA,PROE,UG,SolidWorks等.压缩文件请下载最新的WinRAR软件解压。
- 2. 本站的文档不包含任何第三方提供的附件图纸等,如果需要附件,请联系上传者。文件的所有权益归上传用户所有。
- 3. 本站RAR压缩包中若带图纸,网页内容里面会有图纸预览,若没有图纸预览就没有图纸。
- 4. 未经权益所有人同意不得将文件中的内容挪作商业或盈利用途。
- 5. 人人文库网仅提供信息存储空间,仅对用户上传内容的表现方式做保护处理,对用户上传分享的文档内容本身不做任何修改或编辑,并不能对任何下载内容负责。
- 6. 下载文件中如有侵权或不适当内容,请与我们联系,我们立即纠正。
- 7. 本站不保证下载资源的准确性、安全性和完整性, 同时也不承担用户因使用这些下载资源对自己和他人造成任何形式的伤害或损失。
最新文档
- 电工安全培训试题及答案
- 新《安全生产法》及其他安全知识考试试题及答案
- 卫生监督骨干人才能力提升培训试题(附答案)
- 设备点检润滑考试试题(附答案)
- 护理核心制度考试题目及答案
- 2025版轻工产品展览展示承包合同书
- 2025版物流运输安全合作协议下载
- 2025年汽车融资租赁合同定制版
- 2025年版店铺转让附带未来增值权益合同范本
- 2025仓储与运输安全监管服务合同
- 【完整版】2025年二级建造师《建筑实务》考试真题及答案
- 水库维修承包合同协议书范本
- 2025年浙江省中考英语真题(解析版)
- 2025年广西中考道法真题卷含答案解析
- 2025年国企中层干部竞聘笔试题及答案
- 2025年人民检察院公开招聘用制书记员考试题及答案
- 数学小升初试卷真题打印版
- 医院学术委员会组织职责
- 国际经济法课件马工程版
- 重庆临时摊点管理办法
- 3.4中国的海洋资源课件-八年级地理上册商务星球版
评论
0/150
提交评论