




已阅读5页,还剩62页未读, 继续免费阅读
版权说明:本文档由用户提供并上传,收益归属内容提供方,若内容存在侵权,请进行举报或认领
文档简介
Page 1 Sun SPARCSun SPARC 智慧的结晶, 新一代技术的完美展现 Sun MicroSystems Title: Senior Architect Page 2 Agenda M-Series Overview Product Specification Position/Competitive Page 3 The Industrys Fastest, Most Scalable, Most Energy Efficient Systems Sun FireTM x64 Servers Sun FireTM UltraSPARC Servers Sun Fire CoolThreadsTM Servers Expanded! Enhanced! Breakthrough! New! Sun SPARC Enterprise Servers Page 4 Best Suited for. Sun SPARC Enterprise Servers CoolThreads Servers Sun Fire US-IV/IV+ Servers Sun Fire x64 Servers Mainframe- Class Reliability System Scalability (up to 128 cores) Suns Highest Performing Systems OLTP/Floating Point/Big Memory Solaris 10 scalability & compatibility X64 Industry Standard Servers Fastest Floating Point Performance Mixed Workloads, HPC Multi OS Environments Unmatched, Multi-threaded Throughput Best Power/Cooling Efficiency Solaris scalability & compatibility Suns Most Scalable Systems (up to 144 cores) High Performance and High Reliability Across a Wide Variety of Workloads Solaris scalability & compatibility Runs Solaris 8,9,10 Page 5 What is APL (Advanced Product Line)? The strategic alliance between Sun and Fujitsu furthers Suns commitment to SPARC/Solaris innovation A new generation of jointly-developed and manufactured SPARC/Solaris servers Sun/Fujitsu Alliance 联盟 Sun SPARC Enterprise Server 系统来自Sun/Fujitsu Alliance 的结 果 Advanced Product Line (APL ) = UltraSPARC T1 (Niagara) based servers + SPARC64 VI (Olympus) based servers (OPL) Sun 和 Fujitsu 下一代中高端服务器产品线 Sun 和 Fujitsu 联合设计 Sun 和 Fujitsu 联合制造 运行 Solaris 10 ,保持二进制兼容 完全满足 Sun 软件、存储、和服务 2007 年4 月 17 日正式发布 Page 7 High-End Systems: M8000 & M9000 Entry Systems: T1 & T2 Midrange Systems: M4000 & M5000 UltraSPARC T1SPARC64 VI Sun SPARC Enterprise Servers 8 Mainframe-class reliability Highly scalable performance Advanced virtualization Seamless scalability Easy upgradability Balanced SMP design Price/performance targeted Competitive RAS and S/W Dense rack mount package Highest availability Highest absolute performance Sophisticated resource control Highest scalability Entry level enterprise system Mainframe-class RAS Dense rack mount package SPARC Enterprise Servers M4000 and M5000 M8000 and M9000 M3000 NEW Page 9 Where Sun SPARC Enterprise Systems Excel Server Consolidation/Virtualization Move multiple applications from their individual servers, onto a single platform to achieve higher levels of utilization and efficiency Variable Peak Usage Applications Applications that have unpredictable usage patterns, or widely variable, predictable usage patterns, and require high capacity levels 24x7 Mission Critical Applications (ERP/CRM/OLTP, etc.) Applications that require “mainframe-reliable” uptime levels, and that represent a very high cost risk if they fail to operate continuously. Large SMP Deployments (BIDW, large databases etc.) Applications that require very high capacity levels Page 10 Leading Virtualization Finest granularity partitioning eversingle socket Most hardware partitions ever (up to 24) Solaris Containers deliver thousands of low-overhead software partitions Multiple partitions available on 2+ socket systems Perfectly optimized partitioning technologies: CPU board-level domains for large, mission-critical workloads requiring maximum isolation Single socket level domains for finer granularity with high isolation Enables Cost Saving Consolidation Opportunities Page 11 Solutions from Sun Hard PartitionsVirtual MachinesOS VirtualizationResource Mgmt. Server OS App Multiple OSes Single OS Dynamic System DomainsSolaris Containers (Zones + SRM) Solaris Trusted Extensions Solaris Containers for Linux Applications Solaris Resource Manager (SRM) Trend to flexibilityTrend to isolation Calendar Server Database Web Server SunRay Server App Server Database Mail Server Web Server File Server Identity Server App Server Database Logical Domains Xen VMware Microsoft Virtual Server Page 12 Mainframe-class System Reliability Reduced component count and complexity Memory has extended ECC to survive single/multi bit DRAM failures Memory can be mirrored (system and domain level) Independent XSCF (eXtended System Control Facility) Manages hardware configuration and health, domain configuration and status, error monitor and notification facility Solaris Containers provide software fault isolation Solaris fault-management architectureimproved fault handling and reporting Predictive Self Healing CPU or core offlining Auto diagnosis and recovery Memory page retirement Page 13 Same Reliability as Mainframe Processor Developed by mainframe processor architects Only SPARC64 has instruction retry Only SPARC64 supports data protection of processing units and registers Supports more granular cache degradation M-Series supports dynamic, cache line level degradation Other companies support core-level degradation only SPARC 64 VI/VII Reliability Results in Higher Service Levels Page 14 Exceptional Serviceability Redundant hardware helps protect against failures and outages Processors, I/O, power, fans, disks, and more Automatic reboot and reconfigure from any* failure Dual grid power option*-can survive power grid failure Hot-swap components and dynamic reconfiguration for continuous operation Processors*, memory*, I/O, power, fans, disks, plus Enables online service for repair* Online hardware addition/subtraction or reconfiguration* *Sun SPARC M8000/9000 systems only Page 15 Proven Solaris Scalability Studio12 compilers optimized for SPARC64 VI Systems Scale from 264 sockets (4256 cores) Dual-core, dual-thread SPARC64 VI processor 2.15GHz to 2.4GHz 4 floating point operations per core Up to 733 GB/sec system bandwidth From 16GB to 2TB of DDRII memory From 5 to 288 PCI-X and PCI-E I/O slots Up to 244 GB/sec I/O bandwidth SPARC Enterprise M-Series Scalability and Performance Solving the worlds most complex computing problems Page 16 Suns worldwide Customer Ready program can reduce installation time by 90% and installation issues by 80% Cuts installs from weeks to hours Nearly eliminates install issues like damaged parts,early life failures, incompatibilities Improves your business by reducing installation costs, cutting uncertainty, and simplifying IT infrastructure projects Sun(SM)Customer Ready Program for Sun SPARC Enterprise Systems Page 17 Agenda M-Series Overview Product Specification Position/Competitive SPARC64 VI 处理器 2.15 - 2.4GHz SPARC64 VI (Olympus) 双 SPARC V9 兼容核心,对Solaris 呈现Sun 4u 结构 每核心双线程 每核心 128KB I-cache , 128KB D-csche 5-6MB on-chip L2 Cache, 4 线程共享 90nm 技术 540M transistors 120W2.4GHz 新的Jupiter 系统互联架构和芯片组 支持64 个处理器 带宽可达 330GB/s 5-6 MB L2$ Arbiter/Switch System Interface 128KB D$ 128KB I$ FRU C1 128KB D$ 128KB I$ FRU C2 System Interconnect 5B530MHz SPARC64 VII 处理器 2.8 GHz SPARC64 VII (Jupiter) 4 个SPARC V9 核心,对 Solaris 呈现Sun 4u 结构 每核心双 SMT 线程 每核心 128KB I-cache , 128KB D-csche 5 6MB on-chip 共享 L2 Cache 65nm 技术 150W2.8 GHz 新的Jupiter 系统互联架构和芯片组 支持64 个处理器 带宽可达 330GB/s 5-6 MB L2$ Arbiter/Switch System Interface 128KB D$ 128KB I$ FRU C3 128KB D$ 128KB I$ FRU C4 System Interconnect 5B530MHz 128KB D$ 128KB I$ FRU C2 128KB D$ 128KB I$ FRU C1 20 M3000 System Cabinet Hard Disk Drives Power Switch DVD Drive Status Indicators (Power, XSCF ready, System check) Key Switch (Lock, Service) PCI slots Gigabit Ethernet UP C RCI SAS Front View Rear View USB Seria l LAN 0 & 1 21 DIMM System controller Processor Module MCBI-SCF RAM for firmware XSCF Processor XSCF DVD connector Switch FLP I/O controller (Oberon) DCDC converter Temperature sensor M3000 Detailed View 22 Block Diagram Slot 0 Slot 1 Slot 2 Slot 3 Sun SPARC Enterprise M4000 服务器 系统视图(正面) DVD SAS Disk PSU Fan 系统视图(上面) Memory Module CPU Module Fan Sun SPARC Enterprise M4000 服务器 系统视图(后面) XSCF I/O Cage(IOU) 2x GbE Sun SPARC Enterprise M4000 服务器 系统视图(内部) 2 x Fans 2 x PSU 2 x SAS Disks, DVD, DAT 4 x Memory Boards 1x XSCFU 2 x CPU Modules I/O Cage(IOU) Sun SPARC Enterprise M4000 服务器 M4000 Motherboard M4000 主板 M4000 Motherboard CPU Module Connectors Memory Board Connectors Sun SPARC Enterprise M5000 服务器 系统视图(前面) Fan SAS Disk PSU DVD 系统视图(上面) Memory Module CPU Module Fan Sun SPARC Enterprise M5000 服务器 系统视图(后面) I/O Cage(IOU) XSCF 2x GbE Sun SPARC Enterprise M5000 服务器 系统视图(内部) 4 x Fans 4 x PSU 4 x SAS Disks, DVD, DAT 8 x Memory Boards 4 x CPU Modules 2 x I/O Cage(IOU) (1 PCI-X, 4 PCI-Express per Tray) 1x XSCFU Sun SPARC Enterprise M5000 服务器 CPU Module 2 CPUs per module 2 (M4000) or 4 (M5000) modules per system CPU Module Memory Module 8 DIMM 插槽 1 、2 、4GB DIMMS Uni-XSB 允许混插 Quad-XSB 必须同类 支持ECC 、Chip-kill 支持Mirrored M4000 有4 个 M5000 有8 个 I/O Cage(Tray, IOU) 2 个73GB 10krpm 2.5 SAS 硬 盘 DVD ,DAT 4 个PCI-E(x8) 插槽,hot pluggable 1 个PCI-X(64-bit133Mhz) 插 槽,hot pluggable 2 Gigabit Ethernet ports M4000 有1 个,M5000 有2 个 I/O Cage PCI Cassette for M4000/M5000 IO Cage PCI Cassette for IOU(PCICS) 支持 PCI-E Carrier main body (metal) Moveable carrier plate (plastic) Carrier slot keyholes Operating handleCard retainer (5 total, 3 types) Memory Mirroring Systems with no memory mirroring Memory mirroring on Mx000 Memory Sun SPARC Enterprise M8000 服务器结构 系统视图 ( 前面) 9x PSU 4x CMU 2x XSCF DVD/DAT Fan 系统视图 ( 后面) Fan 4x IOU Sun SPARC Enterprise M8000 服务器结构 Sun SPARC Enterprise M9000-32/64 服务器结构 系统视图 ( 前面) 15x PSU Fan XB Clock Board 2x XSCF 4x IOU DVD/DAT 系统视图 ( 后面) Fan 8x CMU 4x IOU Sun SPARC Enterprise M9000-32/64 服务器结构 CPU Memory Unit(CMU) 最多4 个CPU ,共8 个核心 2x 16 DIMM 插槽,最多128GB 内存 Memory must be installed in banks of 16 DIMMs Group A must be populated first If mixing DIMM sizes, larger DIMMs should be in Group A DIMM sizes may not be mixed within a group Maximum 16-way interleave Memory mirroring is not possible on quad-mode I/O Unit(IOU) 支持每CMU 1 个IOU 支持多 CMU 1 个IOU 2x 4 PCI-E(x8) 插槽 I/O 卡选项 2x 73GB 2.5” SAS HDD 2x GbE 卡占PCI-E 插槽 PCI-E 插槽可分配到4 个XSB 最多连8 个I/O Expansion Box Link Card 占用 PCI-E 插槽 IOU 被分配到XSB ,XSB 可被分配到domain M9000-64 Cabling XB Data : 48 cables XB CLK : 8 cables CLK Data : 2 cables CLK CLK : 4 cables XSCF Data : 2 cables Sun SPARC Enterprise M9000-32/64 服务器结构 Methodology Theoretical Peak Data B/W The data B/W values come from the SC(System Controller) to MAC(Memory Access Controller) bus-width multiplied by the frequency, then multiplied by the number of SB(System Boards) M4000: 32GB/s = (16B(in)+16B(out) x 0.506GHz x 2SC x 1SB M5000: 64GB/s = (16B(in)+16B(out) x 0.506GHz x 2SC x 2SB M8000: 184GB/s = (16B(in)+8B(out) x 0.480GHz x 4SC x 4SB M9000-32: 368GB/s = (16B(in)+8B(out) x 0.480GHz x 4SC x 8SB M9000-64: 737GB/s = (16B(in)+8B(out) x 0.480GHz x 4SC x 16SB Methodology Theoretical Peak I/O B/W The I/O B/W values come from the SC(System Controller) to Oberon(PCI Host Bridge) bus-width multiplied by the frequency M4000: 8GB/s = (4B(in)+4B(out) x 0.506GHz x 2SC x 1IOB M5000: 16GB/s = (4B(in)+4B(out) x 0.506GHz x 2SC x 2IOB M8000: 61GB/s = (4B(in)+4B(out) x 0.480GHz x 2SC x 2Oberon x 4IOU M9000-32: 122GB/s = (4B(in)+4B(out) x 0.480GHz x 2SC x 2Oberon x 8IOU M9000-64: 244GB/s = (4B(in)+4B(out) x 0.480GHz x 2SC x 2Oberon x 16IOU Sun SPARC Enterprise Data Bandwidth M8000/M9000 Mirrored Memory All Memory is mirrored 4 DIMMs 4 DIMMs Mirror 4 DIMMs 4 DIMMs Mirror 4 DIMMs 4 DIMMs 4 DIMMs 4 DIMMs Mirror 4 DIMMs 4 DIMMs 4 DIMMs 4 DIMMs Mirror CPU0 CPU1 CPU2 CPU3 MAC0 MAC1 MAC2 MAC3 SC0 SC1 SC2 SC3 = Group A = Group B Page 46 Add I/O slots to all M-Series servers PCI-X or PCI-E I/O Each Expansion Unit adds 12 I/O slots Fully redundant I/O expansion Unit Expand I/O Connectivity Independent of System Size External IO Expansion Box展箱扩 External IO Expansion Box 扩展箱 系统视图(前面) 系统视图(后面) External IO Expansion Box 扩展箱 FRU 和PCI 32 Lane PCIe Switch PLX PEX8532 Switch BridgeBridgeBridge NEC PCI-X to PCIe Bridge UPD720400 8 Lane PCIe Uplink 6 PCI-X Slots Link 0 Slot 1 Slot 2 Slot 4 Slot 5 Slot 6 Slot 3 Switch SwitchSwitch 8 Lane PCIe Link 0 Slot 1 Slot 2 Slot 4 Slot 5 Slot 6 Slot 3 6 PCIe Slots External IO Expansion Box 扩展箱结构 PCI card Carrier Handle moves in/out, card moves up/down Engages/disengages card from I/O Expansion Unit slot Handle Screw Lock PCI Cassette 最大连接 M4000M5000M8000M9000-32M9000-64 Max IOU124816 Max PCI-E483264128 Max I/O Box24163264 Max PCI slot2550112224288 PCI I/O Slot M4000 和M5000 IO-Box 配置 Up to 2x I/O Boxes per IOU M5000 IO-Box IO-Box IO-Box IO-Box IOU #1 IOU #0 x2Linkx2 19” Rack M4000 IO-Box IO-Box IOU #0 x2Link 19” Rack External IO Expansion Box 扩展箱 M4000 和M5000 IO-Box 配置 Up to 2x I/O Boxes per IOU IO- IOU PCIe PCIe PCIe PCIe PCIe PCIe PCIe PCIe PCIe PCIe PCIe PCIe PCIe PCIe PCIe PCIe PCIe PCIe PCIe PCIe PCIe PCIe PCIe PCIe Link Card PCIe PCIe PCIe PCIe PCI-X Link cards can be populated into any PCIex slots IO- The number of PCI slots per 18 slots IOU : 25 slots IOU: 1 (PCI-X) IOU-Box: 2x 12 Link Card Link Card Link Card Max I/O BoxesMax PCI SlotsRemarks M40002251 IOU x 25 slots M50004502 IOU x 25 slots External IO Expansion Box 扩展箱 M8000 和M9000 IO-Box 配置 19” Rack IO-Box x2x2x2x2Link Base Cabinet Rear View M8000: Maximum of 8x IO- Boxes (IO-Box: 4U) IOU #3 #2#1#0 19” RackBase Cabinet19” Rack Rear View M9000-32: Maximum of 16x IO- Boxes (IO-Box: 4U) Link IOU #6#4 IO-Box IO-Box IO-Box IO-Box IO-Box IO-Box IO-Box IO-Box IO-Box IO-Box IO-Box IO-Box IO-Box IO-Box IO-Box IO-Box IO-Box IO-Box IO-Box IO-Box IO-Box IO-Box IO-Box x2x2x2x2 IOU IOU IOU IOU IOU IOU #2#0 IOU #7#5 IOU IOU IOU #3#1 External IO Expansion Box 扩展箱 M8000 和M9000 IO-Box 配置 IO- Box IO- Box IO- Box IO- Box IO- Box IO- Box IO- Box Expansion Cabinet 19” Rack IO- Box IO- Box IO- Box IO- Box IO- Box IO- Box IO- Box IO- Box Rear View x1x1x1x1Link Base Cabinet19” Rack IO- Box IOU #14 M9000-64: Maximum of 32x IO-Boxes Configuration (IO-Box: 4U) IOU #12 IOU #10 IOU #8 IOU #15 IOU #13 IOU #11 IOU #9 IOU #6 IOU #4 IOU #2 IOU #0 IOU #7 IOU #5 IOU #3 IOU #1 x1x1x1x1Link External IO Expansion Box 扩展箱 M8000 和M9000 IO-Box 配置 Up to 2x I/O Boxes per IOU IO-Box IO PCIe PCIe PCIe PCIe PCIe PCIe PCIe PCIe PCIe PCIe PCIe PCIe PCIe PCIe PCIe PCIe PCIe PCIe PCIe PCIe PCIe PCIe PCIe PCIe Link Card PCIe PCIe IO-Box PCIe PCIe PCIe PCIe PCIe PCIe #0 #1 #2 #3 #4 #5 #6 #7 Link Card Link Card Link Card Max I/O Boxes Max PCI Slots Remarks M800081124 IOU x 28 slots M9000162248 IOU x 28 slots M9000+ Expansion 16288Limited to testing External IO Expansion Box 扩展箱 XSCF 可以用来设置和管理监控M4000/M5000 和M8000/M9000 Shell - 支持串口和网口的连接 Web - Browser User Interface (BUI) 支持Web 访问 SNMP - MIB-I/II ,支持 SNMPv1/2/3 Mail 用以报告系统状态 XSCF 提供console redirection, 通过internal network 显示每个 domain 的OS console LAN (RJ45) USB (1.0) Serial (RJ45) RCI (Fujitsu use only) UPC (DB9) XSCF Monitor Page 58 Agenda M-Series Overview Product Specification Position/Competitive Sun SPARC Enterprise M4000 对比Sun Fire V490 M4000V490 Processor SPARC64 VIUltraSPARC IV+ 2.15GHz, 5MB L2$2.1 GHz, 2MB L2$, 32 MB L3$ Max 4 (8 core)Max 4 (8 core) Memory Max 64GB Internal Disks Max 2 (2.5” SAS)Max 2 (FC) Removable MediaDVD, DATDVD On-board IO2 GbE ports2 GbE ports Memory Bandwidth20 GBps4.8 GBps I/O Bandwidth6 GBps1.2 GBps PCI Slots4 PCIe, 1 PCI-X6 PCI External IO ExpansionYesNo Enclosure6U5U Redundant PartsDisk, PSU, FanDisk, PSU, Fan Hot-swappable partsDisk, PSU, FanDisk, PSU, Fan Power Options1-phase 1+1 cables1-phase 1+1 cables DomainsMax 21 domain RAS ManagementXSCF (service processor)RSC Max 128GB * Sun SPARC Enterprise M5000 对比Sun Fire V890 M5000V890 Processor SPARC64 VIUltraSPARC IV+ 2.15GHz, 5MB L2$2.1 GHz, 2MB L2$, 32 MB L3$ Max 8 (16 core)Max 8 (16 core) Memory Max 128GB Internal Disks Max 4 (2.5” SAS)Max 12 (FC) Removable MediaDVD, DATDVD, DDS-4 On-board IO4 GbE ports1 GbE, 1 10/100E ports Memory Bandwidth40 GBps9.6 GBps I/O Bandwidth12 GBps1.2 GBps PCI Slots8 PCIe, 2 PCI-X9 PCI External IO ExpansionYesYes Enclosure10U17U Redundant PartsDisk, PSU, FanDisk, PSU, Fan Hot-swappable partsDisk, PSU, FanDisk, PSU, Fan Power Options1-phase 2+2 cables1-phase 2+1 cables DomainsMax 41 Domain RAS ManagementXSCF (service processor)RSC Max 256GB * Sun SPARC Enterprise M8000对比 Sun Fire E6900 M8000E6900 Processor SPARC64 VIUltraSPARC IV+ 2.28 2.4GHz, 6MB L2$1.95 GHz, 2MB L2$, 32 MB L3$ Max 16 (32 core)Max 24 (48 core) Memory Max 512GBMax 384 GB System Bandwidth93 GBps9.6 GBps Memory Bandwidth 170 GBps38 GBps I/O Bandwidth48 GBps8 GBps Internal Disks Max 16 (2.5” SAS)None Removable MediaDVD, DATNone CMU (System Board) and IOUMax 4 each6 CMU, 4 I/O Boats PCI Slots (on IOU)Max 32 (PCIe)Max 24 PCI-X External IO ExpansionYesYes Redundant PartsCMU, IOU, XSCF, Clock board, Disk, PSU, Fan, XBSysBd, PSU, Fan, FireplaneSwitch, SC Hot-Swappable Parts CMU, IOU, XSCF, Disk, PSU, FanPSU, Fan, SC, SysBd, IO-Bd Power Options1-phase/3-phase/dual-grid1-phase/dual-grid DomainsMax 16Max 4 domains RAS ManagementXSCF (service processor)SC (System Controller) Sun SPARC Enterprise M9000 对比Sun Fire E25K M9000-64E25K Processor SPARC64 VIUltraSPARC IV+ 2.28 2.4GHz, 6MB L2$1.8 GHz, 2MB L2$, 32 MB L3$ Max 64 (128 core)Max 72 (144 core) Memory Max 2TBMax 1TB System Bandwidth 737 GBps43 GBps Memory Bandwidth 683 GBps173 GBps I/O Bandwidth 192 GBps40 GBps Internal Disks Max 64 (2.5” SAS)None Removable MediaDVD, DATNone CMU (System Board) and IOUMax 16 eachMax 18 each PCI Slots (on IOU)Max 128 (PCIe)72 PCI-X External IO ExpansionYesYes Redundant PartsCMU, IOU, XSCF, Clock board, Disk, PSU, Fan, XBCMU, IOU, SC, PSU, Fan, Backplane Hot-Swappable Parts CMU,
温馨提示
- 1. 本站所有资源如无特殊说明,都需要本地电脑安装OFFICE2007和PDF阅读器。图纸软件为CAD,CAXA,PROE,UG,SolidWorks等.压缩文件请下载最新的WinRAR软件解压。
- 2. 本站的文档不包含任何第三方提供的附件图纸等,如果需要附件,请联系上传者。文件的所有权益归上传用户所有。
- 3. 本站RAR压缩包中若带图纸,网页内容里面会有图纸预览,若没有图纸预览就没有图纸。
- 4. 未经权益所有人同意不得将文件中的内容挪作商业或盈利用途。
- 5. 人人文库网仅提供信息存储空间,仅对用户上传内容的表现方式做保护处理,对用户上传分享的文档内容本身不做任何修改或编辑,并不能对任何下载内容负责。
- 6. 下载文件中如有侵权或不适当内容,请与我们联系,我们立即纠正。
- 7. 本站不保证下载资源的准确性、安全性和完整性, 同时也不承担用户因使用这些下载资源对自己和他人造成任何形式的伤害或损失。
最新文档
- 设备采购与验收规范介绍
- 年度业绩考核报告表
- 家庭月度收支统计报表
- 动词不定式与从句的区别高二英语语法讲解
- 跨界合作与创新生态系统对产业发展的促进作用
- 人教版高中物理实验操作技能提升课教案
- 国际品牌在中国市场表现表格
- 乡村健康产业发展与社会参与机制
- 初中英语课本中动词时态的掌握技巧
- 中小企业数字化转型的风险评估与应对策略
- 人工智能法治领域创新型人才培养研究
- 2025年安徽芜湖宜居投资(集团)有限公司招聘笔试参考题库含答案解析
- 攀枝花市社区工作者招聘真题2024
- 医用气体配送服务投标方案(完整技术标)
- 邮政安全培训课件
- 集电线路管理培训
- 传媒公司保密协议8篇
- 《球阀结构分析》课件
- 《工程招投标与合同管理》参考试题库(含答案)
- 2025湖南省建筑安全员《B证》考试题库及答案
- 4D厨房管理培训课件
评论
0/150
提交评论