




已阅读5页,还剩1页未读, 继续免费阅读
版权说明:本文档由用户提供并上传,收益归属内容提供方,若内容存在侵权,请进行举报或认领
文档简介
Power Meter Central de medida Centrale de mesure PM200 Retain for future use. Consrvese para futuras consultas. conserver pour une utilisation ultrieure Instruction Bulletin Manual de instrucciones Manuel dutilisation PM200 Install.book Page 1 Thursday, December 15, 2005 11:07 AM 2006 Schneider Electric. All Rights Reserved. 63230-510-200A1Appendix C Register List 1/2006Register List EN47 ENGLISH APPENDIX C REGISTER LIST Register List RegisterUnitsScale FactorRangeDescription 4000 to 4001 kWhSee register 41080 to 0 xFFFFFFFFReal Energy Consumption 4002 to 4003 kVAhSee register 41080 to 0 xFFFFFFFFApparent Energy Consumption 4004 to 4005 kVARhSee register 41080 to 0 xFFFFFFFFReactive Energy Consumption 4006kWSee register 41070 to 32767Total Real Power 4007kVASee register 41070 to 32767Total Apparent Power 4008kVARSee register 41070 to 32767Total Reactive Power 40090.00010 to 10000Total Power Factor 4013Hz0.014500 to 6500Frequency (derived from Phase A) 4014kWSee register 41070 to 32767Total Real Power Present Demand 4015kVASee register 41070 to 32767Total Apparent Power Present Demand 4016kVARSee register 41070 to 32767Total Reactive Power Present Demand 4017kWSee register 41070 to 32767Total Real Power Max Demand 4018kVASee register 41070 to 32767Total Apparent Power Max Demand 4019kVARSee register 41070 to 32767Total Reactive Power Max Demand 4020AmpSee register 41050 to 32767Current, Instantaneous, Phase A 4021AmpSee register 41050 to 32767Current, Instantaneous, Phase B 4022AmpSee register 41050 to 32767Current, Instantaneous, Phase C 4024AmpSee register 41050 to 32767Current, Present Demand, Phase A 4025AmpSee register 41050 to 32767Current, Present Demand, Phase B 4026AmpSee register 41050 to 32767Current, Present Demand, Phase C 4027AmpSee register 41050 to 32767Current, Max Demand, Phase A 4028AmpSee register 41050 to 32767Current, Max Demand, Phase B 4029AmpSee register 41050 to 32767Current, Max Demand, Phase C 4030VoltSee register 41060 to 32767Voltage, Phase A-B 4031VoltSee register 41060 to 32767Voltage, Phase B-C tRegisters 4000 4005, 7002, and 7003 are unsigned long integer values tRegisters 4006 4104, 4109 7001, and 7004 7162 are unsigned integer values tRegisters 4105 4108 are signed integer values tAll registers are Read-only except for 4117 4128 and 7015 7162. PM200 Install.book Page 47 Thursday, December 15, 2005 11:07 AM 2006 Schneider Electric. All Rights Reserved. Appendix C Register List63230-510-200A1 Register List1/2006 EN48 ENGLISH 4032VoltSee register 41060 to 32767Voltage, Phase A-C 4033VoltSee register 41060 to 32767Voltage, Phase A-N 4034VoltSee register 41060 to 32767Voltage, Phase B-N 4035VoltSee register 41060 to 32767Voltage, Phase C-N 41054 = 0.0001 3 = 0.001 2 = 0.01 1 = 0.1 0 = 1.0 1 = 10.0 2 = 100.0 3 = 1000.0 4 = 10000.0 Scale Factor I (current) 41064 = 0.0001 3 = 0.001 2 = 0.01 1 = 0.1 0 = 1.0 1 = 10.0 2 = 100.0 3 = 1000.0 4 = 10000.0 Scale Factor V (voltage) 41074 = 0.0001 3 = 0.001 2 = 0.01 1 = 0.1 0 = 1.0 1 = 10.0 2 = 100.0 3 = 1000.0 4 = 10000.0 Scale Factor W (power) RegisterUnitsScale FactorRangeDescription tRegisters 4000 4005, 7002, and 7003 are unsigned long integer values tRegisters 4006 4104, 4109 7001, and 7004 7162 are unsigned integer values tRegisters 4105 4108 are signed integer values tAll registers are Read-only except for 4117 4128 and 7015 7162. PM200 Install.book Page 48 Thursday, December 15, 2005 11:07 AM 2006 Schneider Electric. All Rights Reserved. 63230-510-200A1Appendix C Register List 1/2006Register List EN49 ENGLISH 41084 = 0.0001 3 = 0.001 2 = 0.01 1 = 0.1 0 = 1.0 1 = 10.0 2 = 100.0 3 = 1000.0 4 = 10000.0 Scale Factor E (energy) 4109Feature Bitmap (future use, always returns zero presently) 4112Error Bitmap: bit 0: Phase A Voltage over range bit 1: Phase B Voltage over range bit 2: Phase C Voltage over range bit 3: Phase A Current over range bit 4: Phase B Current over range bit 5: Phase C Current over range bit 6: Frequency out of range bit 7-15: Reserved for future use 4113Reserved, always returns 0 4114Reserved, always returns 0 4115Reserved, always returns 0 4116Reserved, always returns 0 4117Minutes1 to 60Thermal Demand Interval 4118Minutes1 to 60Power Block Demand Interval 41190 to 60Power Block Demand Sub-Intervals If set to 0, a subinterval of 15 seconds is used for Demand Intervals less than or equal to 15 minutes, or 60 seconds for intervals greater than 15 minutes. 41201 to 32767CT Ratio Primary 41211 or 5CT Ratio - Secondary RegisterUnitsScale FactorRangeDescription tRegisters 4000 4005, 7002, and 7003 are unsigned long integer values tRegisters 4006 4104, 4109 7001, and 7004 7162 are unsigned integer values tRegisters 4105 4108 are signed integer values tAll registers are Read-only except for 4117 4128 and 7015 7162. PM200 Install.book Page 49 Thursday, December 15, 2005 11:07 AM 2006 Schneider Electric. All Rights Reserved. Appendix C Register List63230-510-200A1 Register List1/2006 EN50 ENGLISH 41221 to 32767PT Ratio - Primary 41230,1,10,100PT Ratio - Scale (0 = No PT) 4124100,110,115,120PT Ratio Secondary 4125Hz50 or 60Service Frequency 4126N/AReset tWrite 30078 to clear all Energy Accumulators. tWrite 21212 to reset Peak Demand values to Present Demand Values. tRead always returns 0. 412710,11,12,30, 31, 32, 40, 42, 44 System Type 41280,1Units: 0 = IEC, 1 = IEEE units 70000 to 32767Firmware Version, Reset System 7001Firmware Version, Operating System 7002/03Serial Number (date/time of mfg. in UTC) 700415201Device ID = 15201 70051 to 247Modbus Address 70062400,4800, 9600,19200 Baud rate RegisterUnitsScale FactorRangeDescription tRegisters 4000 4005, 7002, and 7003 are unsigned long integer values tRegisters 4006 4104, 4109 7001, and 7004 7162 are unsigned integer values tRegisters 4105 4108 are signed integer values tAll registers are Read-only except for 4117 4128 and 7015 7162. PM200 Install.book Page 50 Thursday, December 15, 2005 11:07 AM 2006 Schneider Electric. All Rights Reserved. 63230-510-200A1Appendix C Register List 1/2006Supported MODBUS Commands EN51 ENGLISH Supported MODBUS Commands CommandDescription 0 x03Read holding registers 0 x04Read input registers 0 x06Preset single registers 0 x
温馨提示
- 1. 本站所有资源如无特殊说明,都需要本地电脑安装OFFICE2007和PDF阅读器。图纸软件为CAD,CAXA,PROE,UG,SolidWorks等.压缩文件请下载最新的WinRAR软件解压。
- 2. 本站的文档不包含任何第三方提供的附件图纸等,如果需要附件,请联系上传者。文件的所有权益归上传用户所有。
- 3. 本站RAR压缩包中若带图纸,网页内容里面会有图纸预览,若没有图纸预览就没有图纸。
- 4. 未经权益所有人同意不得将文件中的内容挪作商业或盈利用途。
- 5. 人人文库网仅提供信息存储空间,仅对用户上传内容的表现方式做保护处理,对用户上传分享的文档内容本身不做任何修改或编辑,并不能对任何下载内容负责。
- 6. 下载文件中如有侵权或不适当内容,请与我们联系,我们立即纠正。
- 7. 本站不保证下载资源的准确性、安全性和完整性, 同时也不承担用户因使用这些下载资源对自己和他人造成任何形式的伤害或损失。
最新文档
- 课件模板中的女生人物画
- 课件格式变成应用程序
- 开餐饮员工培训
- 小学防疫知识培训
- 医生培训学习汇报
- 课件显示错误处理
- 广东红楼梦自考试题及答案
- 乐理简谱考试题及答案
- 课件显示会标
- 科技创新考试题及答案
- G-T 20986-2023 信息安全技术 网络安全事件分类分级指南
- 建筑工程技术专业《建筑力学》课程标准
- JC-T 2127-2012 建材工业用不定形耐火材料施工及验收规范
- 人教版小学英语所有语法及人教版小学英语语法大全
- 雅思词汇2000(带音标)
- 英雄联盟游戏分析报告
- 黑白装饰画教学课件
- 《休闲时尚品牌》课件
- 保健食品用原料人参叶团体标准
- 小儿支气管肺炎护理查房
- 五年级上册道德与法治总复习资料
评论
0/150
提交评论