Accurate diameter measurement of etelgeuse using the VLTIAMBE使用vltiambe参宿四直径准确的测量_第1页
Accurate diameter measurement of etelgeuse using the VLTIAMBE使用vltiambe参宿四直径准确的测量_第2页
Accurate diameter measurement of etelgeuse using the VLTIAMBE使用vltiambe参宿四直径准确的测量_第3页
Accurate diameter measurement of etelgeuse using the VLTIAMBE使用vltiambe参宿四直径准确的测量_第4页
Accurate diameter measurement of etelgeuse using the VLTIAMBE使用vltiambe参宿四直径准确的测量_第5页
已阅读5页,还剩12页未读 继续免费阅读

下载本文档

版权说明:本文档由用户提供并上传,收益归属内容提供方,若内容存在侵权,请进行举报或认领

文档简介

1、accurate diameter measurement of betelgeuse using the vlti/amber instrumento. hernndez, a. chellilaboratoire dastrophysique de grenoblelaboratoire dastrophysique de grenobleindexastrophysical source & experimental conditionsbetelgeusestrong fluxes & low contrastdata reductionframe selectionp

2、2vm vs. fouriervisibility analysisuniform disk diameter (perrin et al. 2004)uniform disk + spot model or jitter ?conclusionsgoalsdemonstrate amber capability to precisely measure low contrast visibilitiesvalidate p2vm methodgive a very accurate measurement of betelgeuse diameterbetelgeuseapparent ma

3、gnitude (v) +0.3 to +1.2spectral type m2iab(3600k)variable type sr c (semi-regular)distance approx.130 pcsirius (calibrator)apparent magnitude (v)a = 1.47b = 8.44variable type eclipsing binaryspectral type a = a1v (9,900k)b = da2 (25,200k)distance approx. 2.64 0.01 pcobservationsbetelgeusebaseline 1

4、6m5 observation files1000 frames/filefebruary 2006, at1-at3, r=1500siriusbaseline 13m5 observation files500 frames/fileraw data & final visibilityframe selection - snrframe selection - fluxframe selection p2vm 2p2vm vs. fourierbetelgeuse calibrated visibilityvalidate method p2vm for low contrast

5、uniform disk diameterperrin et al. 2004 = 43.33 0.04 mas(blue)amber = 42.85 0.02 mas(red)uniform disk diameter slope?uniform disk + spot = 42.50 0.02 masijitter correction = 42.60 0.02 masvm=ve2222siriuss = 0.343 mbetelgeuse 25%conclusionsamber is capable to give very low contrast visibilities in high flux conditionsp2vm method is consistent with fourier methodp2vm validation can be used to properly measure the bias substraction in low contrast and low flux databetelgeuse

温馨提示

  • 1. 本站所有资源如无特殊说明,都需要本地电脑安装OFFICE2007和PDF阅读器。图纸软件为CAD,CAXA,PROE,UG,SolidWorks等.压缩文件请下载最新的WinRAR软件解压。
  • 2. 本站的文档不包含任何第三方提供的附件图纸等,如果需要附件,请联系上传者。文件的所有权益归上传用户所有。
  • 3. 本站RAR压缩包中若带图纸,网页内容里面会有图纸预览,若没有图纸预览就没有图纸。
  • 4. 未经权益所有人同意不得将文件中的内容挪作商业或盈利用途。
  • 5. 人人文库网仅提供信息存储空间,仅对用户上传内容的表现方式做保护处理,对用户上传分享的文档内容本身不做任何修改或编辑,并不能对任何下载内容负责。
  • 6. 下载文件中如有侵权或不适当内容,请与我们联系,我们立即纠正。
  • 7. 本站不保证下载资源的准确性、安全性和完整性, 同时也不承担用户因使用这些下载资源对自己和他人造成任何形式的伤害或损失。

评论

0/150

提交评论