




版权说明:本文档由用户提供并上传,收益归属内容提供方,若内容存在侵权,请进行举报或认领
文档简介
1、Ma c i nt os h PI CTi ma ge f or ma ti s not s uppor t e dThese images demonstrate a distal femoral shaft fracture occurring from blunt trauma.Before performing antegrade femoral nailing, a high-qualityAP radiograph of the hip is necessary to rule out occultfemoral neck fracture.Many patients with f
2、emoral shaft injuries have CT scans performedto rule out intraabdominal injury. The CT scan cuts through thefemoral neck should also be reviewed to rule out fracture.Lateral decubitus position is preferred for antegrade femoralnailing in the patient with normal pulmonary status and nospine or pelvic
3、 injury. The affected leg is flexed, exposing the piriformis fossa without steric interference from the patients torso.The downside leg is well supported and padded to avoid neuropraxia. The surgeon is pointing to the starting point for the piriformis entry point.View of the area that is prepped out
4、 for performing the nailing.PIRIFORMISFOSSAThe piriformis fossa entry portal is directly in line with the canalof the shaft. However, it is slightly posterior to the femoral neck.It is curvilinear and angled posteriorly.Because the piriformis entry portal is on a sloped surface, astraight awl must b
5、e introduced first at an angle to the femoralshaft directly anteriorly12and then as its introduced, the hand is raised up togo in line with the femoral shaft.1cmThe skin incision, which can be approximately 1 to 1-1/2cm in length, should be made at a distance away from the piriformis fossa to allow
6、for direct entry into the fossa. This can be best estimated by looking1cmat the AP radiograph to determine how proximal the incisionneeds to be with respect to the trochanter. The heavier thepatient, the more proximal in the buttocks the incision needs tobe in order to be in line with the femoral sh
7、aft.The fascia of the Tensor fascia Lata muscle is divided, exposing some of the musculature. The perfect lateral radiograph of the hip demonstrates theneck to be colinear with the shaft and slightly anterior to it.The piriformis fossa is easier visualized.The straight awl is introduced through the
8、incision, thengently placed against the piriformis fossa directed anteriorly.The awl is introduced into the femoral canal; as it entersthe bone, the awl is adjusted to be in line with the femoralshaft by moving the hand and awl anteriorly.The awl is introduced into the femoral canal; as it entersthe
9、 bone, the awl is adjusted to be in line with the femoralshaft by moving the hand and awl anteriorly.Once the awl has been introduced gently, it is tappeddown past the calcar to allow for easy passage of theguidewire.Once the awl has been introduced gently, it is tappeddown past the calcar to allow
10、for easy passage of theguidewire.The guidewire should have a gentle distal bend to allow easy passage across the fracture site. The guidewire is introduced down the femoral shaft.A soft tissue protector can be used to minimize muscle injury proximally.The guidewire is advanced down the canal. Note t
11、he colinearity of the entry point with the center of the shaft.The guidewire is introduced to the level of the fracture.The fracture is reduced and the guidewire is passed across and distally until it is just shy of the epiphyseal scar in the center of the femur on the AP radiograph. This is particu
12、larly important for distal fractures.Once the guidewire is fully introduced, length may bemeasured in many ways. While some systems havejigs to measure length, a foolproof system is to measure a residual of a guidewire of the same length.The above image demonstrates a second guidewire of thesame len
13、gth introduced to the level of the trochanter.A Kocher clamp is placed on the guidewire so that the residual can be directly measured.Measuring the residual from this guidewire will give an exact measurement of the longest nail that is possible for this patient. After measurement is obtained, the fe
14、moral canal is reamed.The reamer introduced through the stab incision and the soft-tissue protector used to protect the musculature.After reaming is complete, the appropriate size nail is chosen.Before the nail is inserted, as with any nailing procedure, theproximal jig needs to be checked for appro
15、priate alignment ofthe locking mechanism.An exchange tube is placed over the ball-tip guidewire, which is then removed. A straight guidewire is then placed through the exchange tube, which is then removed,allowing for placement of the nail over the straight guidewire.The nail is gently tapped down t
16、he canal. Any significantresistance warrants biplanar radiographic confirmation ofappropriate position of both the guidewire and the nail, aswell as areas of the femoral neck for possible fracture.After the nail is appropriately seated, with the jig at thelevel of the greater trochanter, the proximal jig is used tolock the nail. Distal locking is generally performed using a freehand technique via perfect circles.The above image demonstrates the C-arm in a position to view a perfect circl
温馨提示
- 1. 本站所有资源如无特殊说明,都需要本地电脑安装OFFICE2007和PDF阅读器。图纸软件为CAD,CAXA,PROE,UG,SolidWorks等.压缩文件请下载最新的WinRAR软件解压。
- 2. 本站的文档不包含任何第三方提供的附件图纸等,如果需要附件,请联系上传者。文件的所有权益归上传用户所有。
- 3. 本站RAR压缩包中若带图纸,网页内容里面会有图纸预览,若没有图纸预览就没有图纸。
- 4. 未经权益所有人同意不得将文件中的内容挪作商业或盈利用途。
- 5. 人人文库网仅提供信息存储空间,仅对用户上传内容的表现方式做保护处理,对用户上传分享的文档内容本身不做任何修改或编辑,并不能对任何下载内容负责。
- 6. 下载文件中如有侵权或不适当内容,请与我们联系,我们立即纠正。
- 7. 本站不保证下载资源的准确性、安全性和完整性, 同时也不承担用户因使用这些下载资源对自己和他人造成任何形式的伤害或损失。
最新文档
- 民间质押担保合同范本
- 线上教育劳务合同范本
- 门面租赁变更合同范本
- 签了协议要求解除合同
- 转让包箱设备合同范本
- 2025至2030中国肿瘤分子生物标志物行业市场占有率及投资前景评估规划研究报告
- 监理专业知识试题及答案
- 审计专业知识试题及答案
- 银行从业资格证考试公告及答案解析
- 安全生产工作测试题及答案解析
- T-FSF 003-2024 杂交石斑鱼人工育苗技术规范
- T-CIRA 41-2022 同位素生产回旋加速器液态靶验收规范
- 伊斯兰教完整版本
- 计量经济学知到智慧树章节测试课后答案2024年秋安徽农业大学
- 《西方的文官制度》教学设计
- 外研版九年级英语上册单元模块满分必刷题 Module 1 【刷中考】(广东专用)(含答案)
- 华为ICT大赛网络赛道考试题库(786题)
- 新能源汽车检测与维修专业调研报告
- 2024年保安员证考试题库及答案(共240题)
- 2018低压电力线高速载波通信互联互通技术规范第3部分:检验方法
- 超声科医院感染管理:培训与演练
评论
0/150
提交评论