1、  Camera Calibration Toolbox for MatlabDescription of the calibration parametersAfter calibration, the list of parameters may be stored in the matab file Calib_Results by clicking on Save. The list of variables may be separated into two categories: Intrinsic parameters and extrinsic parameters.

2、 Intrinsic parameters (camera model):The internal camera model is very similar to that used by Heikkil伯a> and Silven at the University of Oulu in Finland. Visit their online calibration page, and their publication page. We specifically recommend their CVPR'97 paper: A Four-step Camera Calibra

3、tion Procedure with Implicit Image Correction. The list of internal parameters: · Focal length: The focal length in pixels is stored in the 2x1 vector fc.· Principal point: The principal point coordinates are stored in the 2x1 vector cc.· Skew coefficient: The skew coefficient definin

4、g the angle between the x and y pixel axes is stored in the scalar alpha_c.· Distortions: The image distortion coefficients (radial and tangential distortions) are stored in the 5x1 vector kc四个内参,包括焦距fc,原点坐标cc,相机坐标系中x和y轴夹角alpha_c(接近90°),几何畸变系数kc.Definition of the intrinsic parameters: Let

5、P be a point in space of coordinate vector XXc = Xc;Yc;Zc in the camera reference frame. Let us project now that point on the image plane according to the intrinsic parameters (fc,cc,alpha_c,kc). Let xn be the normalized (pinhole) image projection:   Let r2 = x2 + y2. After including lens disto

6、rtion, the new normalized point coordinate xd is defined as follows:where dx is the tangential distortion vector:   Matlab中计算几何畸变还考虑了切向畸变Therefore, the 5-vector kc contains both radial and tangential distortion coefficients (observe that the coefficient of 6th order radial distortion term is th

7、e fifth entry of the vector kc).It is worth noticing that this distortion model was first introduced by Brown in 1966 and called "Plumb Bob" model (radial polynomial + "thin prism" ). The tangential distortion is due to "decentering", or imperfect centering of the lens

8、components and other manufacturing defects in a compound lens. For more details, refer to Brown's original publications listed in the reference page. Once distortion is applied, the final pixel coordinates x_pixel = xp;yp of the projection of P on the image plane is:   Therefore, the pixel

9、coordinate vector x_pixel and the normalized (distorted) coordinate vector xd are related to each other through the linear equation: where KK is known as the camera matrix, and defined as follows: 对应于书上的线性映射矩阵AFc(1)和fc(2)分别对应于矩阵A中的f/k和f/l,即转化为按照x和y方向上的像素尺寸为单位In matlab, this matrix is stored in the v

10、ariable KK after calibration. Observe that fc(1) and fc(2) are the focal distance (a unique value in mm) expressed in units of horizontal and vertical pixels. Both components of the vector fc are usually very similar. The ratio fc(2)/fc(1), often called "aspect ratio", is different from 1

11、if the pixel in the CCD array are not square. Therefore, the camera model naturally handles non-square pixels. In addition, the coefficient alpha_c encodes the angle between the x and y sensor axes. Consequently, pixels are even allowed to be non-rectangular. Some authors refer to that type of model

12、 as "affine distortion" model. In addition to computing estimates for the intrinsic parameters fc, cc, kc and alpha_c, the toolbox also returns estimates of the uncertainties on those parameters. The matlab variables containing those uncertainties are fc_error,cc_error, kc_error, alpha_c_e

13、rror. For information, those vectors are approximately three times the standard deviations of the errors of estimationFc_error,cc_error,kc_error,alpha_c_error这四个变量记录四个内参的不确定度,大小设定为三倍标准差. Here is an example of output of the toolbox after optimization: In this case fc = 657.30254 ; 657.74391 and fc_er

14、ror = 0.28487 ; 0.28937, cc = 302.71656 ; 242.33386, cc_error = 0.59115 ; 0.55710, . Important Convention:Pixel coordinates are defined such that 0;0 is the center of the upper left pixel注意:图像左上角默认为原点0;0左下角为0;ny-1右上角为nx-1;0右下角为nx-1;ny-1 of the image. As a result, nx-1;0 is center of the upper right

15、corner pixel, 0;ny-1 is the center of the lower left corner pixel and nx-1;ny-1 is the center of the lower right corner pixel where nx and ny are the width and height of the image (for the images of the first example, nx=640 and ny=480). One matlab function provided in the toolbox computes that dire

16、ct pixel projection map. This function is project_points2.m. This function takes in the 3D coordinates of a set of points in space (in world reference frame or camera reference frame) and the intrinsic camera parameters (fc,cc,kc,alpha_c), and returns the pixel projections of the points on the image

17、 plane. See the information given in the function函数project_points2.m将相机坐标系下的三维点阵按照内参转化成图像平面上的二位点阵.   The inverse mapping: The inverse problem of computing the normalized image projection vector xn from the pixel coordinate x_pixel is very useful in most machine vision applications. However, bec

18、ause of the high degree distortion model, there exists no general algebraic expression for this inverse map (also called normalization). In the toolbox however, a numerical implementation of inverse mapping is provided in the form of a function: normalize.m. Here is the way the function should be ca

19、lled: xn = normalize(x_pixel,fc,cc,kc,alpha_c). In that syntax, x_pixel and xn may consist of more than one point coordinates. For an example of call, see the matlab function compute_extrinsic_init.m.Reduced camera models:Currently manufactured cameras do not always justify this very general optical

20、 model. For example, it now customary to assume rectangular pixels, and thus assume zero skew (alpha_c=0). It一般情况下,相机坐标系中的坐标轴正交,alpha_c就可以默认为0;在非广角镜头中,一般径向畸变模型到4阶就足够了(好的镜头2阶就够了),而且切向畸变可以忽略 is in fact a default setting of the toolbox (the skew coefficient not being estimated). Furthermore, the very g

21、eneric (6th order radial + tangential) distortion model is often not considered completely. For standard field of views (non wide-angle cameras), it is often not necessary (and not recommended) to push the radial component of distortion model beyond the 4th order (i.e. keeping kc(5)=0). This is also

22、 a default setting of the toolbox. In addition, the tangential component of distortion can often be discarded (justified by the fact that most lenses currently manufactured do not have imperfection in centering). The 4th order symmetric radial distortion with no tangential component (the last three

23、component of kc are set to zero) is actually the distortion model used by Zhang. Another very common distortion model for good optical systems or narrow field of view lenses is the second order symmetric radial distortion model. In that model, only the first component of the vector kc is estimated,

24、while the other four are set to zero. This model is also commonly used when a few images are used for calibration (too little data to estimate a more complex model). Aside from distortions and skew, other model reductions are possible. For example, when only a few images are used for calibration (e.

25、g. one, two or three images) the principal point cc is often very difficult to estimate reliably . It is known to be one of the most difficult part of the native perspective projection model to estimate (ignoring lens distortions). If this is the case, it is sometimes better (and recommended) to set

26、 the principal point at the center of the image (cc = (nx-1)/2;(ny-1)/2) and not estimate it further. Finally, in few rare instances, it may be necessary to reject the aspect ratio fc(2)/fc(1) from the estimation. Although this final model reduction step is possible with the toolbox, it is generally

27、 not recommended as the aspect ratio is often 'easy' to estimate very reliably. For more information on how to perform model selection with the toolbox, visit the page describing the first calibration example.   Correspondence with Heikkil notation: In the original Heikkil paper, the in

28、ternal parameters appear with slightly different names. The following table gives the correspondence between the two notation schemes:   Our notationHeikkil notationfc(1)f . Du . sufc(2)f . Dvcc(1)u0cc(2)v0alpha_c0kc(1)f3 . k1kc(2)f5 . k2kc(3)f2 . p1kc(4)f2 . p2kc(5)0A few comments on Heikkil m

29、odel: · Skew is not estimated (alpha_c=0). It may not be a problem as most cameras currently manufactured do not have centering imperfections. · The radial component of the distortion model is only up to the 4th order. This is sufficient for most cases. · The four variables (f,Du,Dv,s

30、u) replacing the 2x1 focal vector fc are in general impossible to estimate separately. It is only possible if two of those variables are known (for example the metric focal value f and the scale factor su). See Heikkil paper for more information. Correspondence with Reg Willson's notation: In hi

31、s original implementation of the Tsai camera calibration algorithm, Reg Willson uses a different notation for the camera parameters. The following table gives the correspondence between the two notation schemes:   Our notationWillson's notationfc(1)f . sx / dpxfc(2)f / dpycc(1)Cxcc(2)Cyalph

32、a_c0Willson uses a first order radial distortion model (with an additional constant kappa1) that does not have an easy closed-form corespondence with our distortion model (encoded with the coefficients kc(1),.,kc(5). However, we included in the toolbox a function called willson_convert that converts

33、 the entire set of Willson's parameters into our parameters (including distortion). This function is called in another function willson_read that directly loads in a calibration result file generated by Willson's code and computes the set parameters (intrinsic and extrinsic) following our no

34、tation (to use that function, first set the matlab variable calib_file to the name of the original willson calibration file). A few extra comments on Willson's model: · Similarly to Heikkil model, the skew is not included in the model (alpha_c=0). · Similarly to Heikkil model, the four

35、 variables (f,sx,dpx,dpy) replacing the 2x1 focal vector fc are in general impossible to estimate separately. It is only possible if two of those variables are known (for example the metric focal value f and the scale factor sx).   Extrinsic parameters:· Rotations: A set of n_ima 3x3 rotat

36、ion matrices Rc_1, Rc_2,., Rc_20 (assuming n_ima=20). · Translations:A外部参数Rc和Tc同时注意n_ima好像是图片的数量(对一个镜头进行参数估计的图片数量) set of n_ima 3x1 vectors Tc_1, Tc_2,., Tc_20 (assuming n_ima=20). Definition of the extrinsic parameters: Consider the calibration grid #i (attached to the ith calibration image),

37、and concentrate on the camera reference frame attahed to that grid. Without loss of generality, take i = 1. The following figure shows the reference frame (O,X,Y,Z) attached to that calibration gid. Let P be a point space of coordinate vector XX = X;Y;Z in the grid reference frame (reference frame shown on the previous figure). Let XXc = Xc;Yc;Zc be the coordinate vector of P in the camera reference frame. Then XX and XXc are related to each other through the following rigid motion equation: XXc = Rc_1 * XX + Tc_1XXc=Rc_1*XX+Tc_1世界坐标系到相机坐标系的投影,用两个外部参数矩阵In parti

温馨提示

  • 1. 本站所有资源如无特殊说明,都需要本地电脑安装OFFICE2007和PDF阅读器。图纸软件为CAD,CAXA,PROE,UG,SolidWorks等.压缩文件请下载最新的WinRAR软件解压。
  • 2. 本站的文档不包含任何第三方提供的附件图纸等,如果需要附件,请联系上传者。文件的所有权益归上传用户所有。
  • 3. 本站RAR压缩包中若带图纸,网页内容里面会有图纸预览,若没有图纸预览就没有图纸。
  • 4. 未经权益所有人同意不得将文件中的内容挪作商业或盈利用途。
  • 5. 人人文库网仅提供信息存储空间,仅对用户上传内容的表现方式做保护处理,对用户上传分享的文档内容本身不做任何修改或编辑,并不能对任何下载内容负责。
  • 6. 下载文件中如有侵权或不适当内容,请与我们联系,我们立即纠正。
  • 7. 本站不保证下载资源的准确性、安全性和完整性, 同时也不承担用户因使用这些下载资源对自己和他人造成任何形式的伤害或损失。

评论

0/150

提交评论