版权说明:本文档由用户提供并上传,收益归属内容提供方,若内容存在侵权,请进行举报或认领
文档简介
北京某住宅小区消防改造工程施工组织设计目录一、消防工程概概况··················································································································41.1工程概况况····································································································································41.2工程内容容····································································································································41.3工程管理理目标························································································································4二、编制依据································································································································5三、施工部署································································································································63.1施工组组织总体部署署·············································································································63.2工程组组织人员明细细与职责说明明···············································································63.2.1主主要管理及技技术人员明细细·····························································································73.2.2主主要管理及技技术人员职责责说明···················································································7四、工程计划进进度安排与控控制················································································84.1工程程进度控制·····················································································································8工程进度计划划························································································································84.1.2项项目进度复核核························································································································84.1.3月月工程报告·····························································································································8五、工程施工管管理措施····································································································95.1质量要要求···································································································································9质量保证体系···························································································································9质量保证具体环环节··············································································································1005.2文档管管理·································································································································1115.3技术管管理·································································································································1125.3.1保保证工程进度度措施············································································································135.3.2保保证施工安全全措施············································································································13消防保卫措施·······················································································································1665.3.4成成品及设备部部件的保护措措施·······················································································1165.3.5环环境保护措施施······················································································································1175.3.6冬冬季施工措施施······················································································································117六、工程实施······························································································································1186.1工程实实施步骤·······················································································································18工程实施阶段···························································································································19纠正和预防措施施·····················································································································199质量记录·····································································································································1996.1.4检验验和试验·······························································································································119七、工程施工规规范及工艺······························································································207.1消防报报警、联动系系统部分························································································207.1.1施施工工艺流程程························································································································207.1.2施施工技术要求求························································································································207.1.3工工程调试验收收························································································································217.2消防喷洒洒系统部分··········································································································22施工工艺流程························································································································22八、工程档案·································································································································24九、验收和移交交·························································································································25注:附表一···································································25附表二···································································26附表三···································································27附表四···································································28附表五···································································29附表六···································································30消防工程概况1.1工程概况况本施工组织针对对朝阳区晨光光家园215、216号楼工地实际际情况编制,由于晨光家园215、216号楼处处于同一人防防层,两处防护单元元均为733m²由一条主通道连接,分分别使用一台报警控制制器,现统一一编制施工组组织。改造所需消防防设备设施如下:基本设备215号楼216号楼探测器4349喷淋头7479手动报警按钮44声光报警器441.2工程内容容火灾自动报警及及控制系统::火灾自动报警及及控制系统改改造主要包括括烟感探测器器、手动报警警按钮、声光光报警器、信信号模块等设设备的布位、安安装及调试,及及配管配线,以以达到消防规规范的要求。对对所有的报警警设备在报警警控制器主机机中进行相应应的编程,来来满足报警系系统的联动关关系要求。喷淋系统统中设置的水水流指示器、信信号阀、报警警阀组等设备备在报警控制制器主机中进进行相应的编编程,来满足足报警系统的的联动关系要要求。简易自动喷淋灭灭火系统:水喷淋系统在此此次工程中采采用简易喷淋淋系统从消防防栓系统主管管道(DN100)取水,通过过湿式报警阀阀后加装信号号碟阀和水流流指示器连接接喷淋支管,来来满足消防规规范要求。工程安装、调试试、检测和维维护1.3工程管理理目标1)本工程为为本公司重点点工程项目。2)实行以合合同期为目标标的项目法施施工,全面履履行工程合同同,保工期、保保质量、保交交工。3)工程修改改控制:项目目中的工程修修改控制由项项目经理提出出,工程修改改控制将包括括工程修改确确认、文件档档案、审查、复复核等。4)质量监督督管理控制::为了保证工工程质量,项项目组配备质质量监督工程程师,按照ISO90001质量管理的的目标、步骤骤、办法完成成质量监督管管理。5)采取有效效可靠的质量量保证措施,创创工程优良。6)建立强有有力的项目领领导班子,组组织高素质的的施工队伍,采采取先进的施施工管理方法法和施工技术术。7)实现安全全生产和文明明施工。编制依据编制该工程技术术标准依据为为:1.1根据建设设单位提供的的施工图、招招标文件及其其他技术文件件;1.2我单位位的消防系统统深化设计图图纸;1.3参照以以下国家标准准、行业标准准和地方标准准;《火灾自动报警警系统设计规规范》GB550116--98《自动喷水灭火火系统设计规规范》(2005版)GB500084-20001《简易自动喷水水灭火系统设设计规程》DDBJ01-6617-20004《人民防空工程程设计规范》(2001版)GB50098-98《建筑设计防火火规范》(2001版)GGBJ16-87《火灾自动报警警系统施工验验收规范》GB501166—92《自动喷水灭火火系统施工及及验收规范》GB50261-2005《北京市建筑安安装工程技术术资料管理规规定》DBJ011-51—2000《电气安装工程程整理检验、评评定标准》GGBI3033-88《建筑电气工程程施工质量验验收规范》GB503003-2002《火灾报警设备备检验规范》GB129778-91《建筑工程施工工质量验收统统一标准》GB503300-20001《建筑工程施工工现场供用电电安全规范》GB50194-93。《建筑工程项目目管理规范》GB/T50326-2001《建筑施工安全全检查标准》JJGJ59--99《建筑安装工程程资料管理规规定》 DDBJ01-511-20000《建筑安装分项项工程施工工工艺规程》 DBJ01-226-96三、施工部署3.1施工组组织总体部署署质量目标:合格格组织与管理:施工合同签定后后,我公司将将成立工程项项目部,实施施管理和施工工,由项目经经理、项目技技术负责人负负责对工程的的领导、指挥挥、协调、决决策等事宜,对对工程的进度度、成本、质质量、安全和和现场文明施施工等全部负负责,进行技技术交底,办办理工程洽商商,汇集整理理工程技术资资料等。进度计划:严格按双方拟定定的开竣工日日期组织施工工,密切配合合整体工程及及装修进度计计划,根据各各项工程的进进度,协调制制定本项工程程的进度计划划表,保证不不影响整体工工期及进度。进进场施工后,根根据整体施工工进度,编排排本专业计划划表,并根据据具体情况随随时调整。3.2工程组组织人员明细细与职责说明明主要管理及技术术人员明细项目经理现场经理系统技术工程师师供应部长电工长水工长安全员预算员文档、材料员管工施工人员电工施工人员3.2.2主主要管理及技技术人员职责责说明3.2.2.11项目经理项目经理的职责责如下:全面负责整个项项目执行情况况商务合同决策公司人员调配处理与建设单位位、监理单位位事宜3.2.2..2现场经经理现场经理职责如如下:实施并全面履行行合同,协调调与建设单位位、监理单位位关系;接受建设单位和和监理单位监监督;协调与各分包的的关系,对工工程进行总体体的协调管理理;工程进度,质量量和成本进行行总体控制;;组织工程验收,交交工和结算;;负责项目人员组组织调配,向向办事处提出出人员增减计计划;领导制订施工计计划,审定各各种施工方案案;对外重要文件的的审定和签发发;考核,评定项目目管理人员的的业绩。3.2.2.33系统技术负负责工程师系统技术负责工工程师直接向向项目经理汇汇报,负责如如下:提供工程系统概概念可行性分分析、系统需需求分析和工工程计算;为系统需求设计计审核提供技技术支持;为项目系统调试试验收提供技技术支持;领导和监督管理理有关队伍实实现安装计划划,保证在时时间计划内完完成合同要求求的安装;按照确定的审核核计划和大纲纲,进行安装装审核;质保人员一起保保证进度审核核符合计划;;保证所有区域房房间达到良好好验收标准;;建立调试计划;;领导和监督管理理测试队伍,按按确认的测试试协议进行测测试;保证项目使用的的所有测试、审审核和测量设设备的准确性性和耐久性;;维护和保存项目目文档、图纸纸和记录。四、工程计划进进度安排与控控制4.1工程进进度控制工程进度计划划工程进度计划严严格按照甲方方的进度要求求:合同签订订后,以20日为一个工工程周期,我我单位将严格格按照施工进进度计划,在在20日内保质、保保量的完成项项目施工。4.1.2项项目进度复核核项目复核按照项项目经理的要要求,进行项项目执行进度度的审核,项项目复核将至至少包括如下下内容:过程和状态复核核;;设计变更控制::设设计变更是是系系统实施过过程程中,难以以避避免的问题题,如如何快速简简捷捷的处理现现场场设计变更更问问题,关系系到到预定工程程进进度的实现现;;验收测试质量控制4.1.3月月工工程报告月进度报告按以以下下格式提交交给给建设单位位与与监理:重点——报告告显显著成绩进度和状态————报告相关项项目执行的的进进度和状态态要预先处理的问问题题预报——报报告告下月将要要进进行的事项项每月需维护和更更新新未完成的的工工作项目五.工程施工管管理措措施5.1质量要要求求项目经理部针对对人人防消防改造工程项目目所制订的的质质量计划。在在在质量上要要求求:(一) 在施工工上,工程和和和系统都应应具具有高度安安全全性。(二) 高可靠靠性。施工的的的工程、系系统统在规定的的时时间内,应应使使故障率降降到到最低,避避免免漏报和误误报报,并做到到易易于维修。(三) 高性能能价格比。(四) 安照合合同要求,工工工程项目所所用用的材料、设设设备和配件件都都应选择质质量量较高的。厂厂厂(商)家有关证明明也应齐备备。(五) 质量方方针:质量第第第一,信誉誉至至上,精益益求求精,业主主满满意。(六) 质量目目标:1、分项工程合合格率1100%。2、单位工程竣竣工验收收一次合格格率率100%。5.1.1质质量量保证体系项目部保证严格格按按照质量体体系系的要求,精精精心组织施施工工,按期、保保保质地完成成此此项消防工工程程。坚决执执行行公司的质质量量方针:质质量量第一,信信誉誉至上,精精益益求精,业业主主满意。工工程程质量保证证体体系见附表表::引用标准《质量体系一生生产产和安装的的质质量保证模模式式》GB/T190002--IISS0900022:1994中华人民共和国国国国家标准GBJl6—87《建筑设计防火火规规范》中华人民共和国国国国家标准GBJ500116—98《火灾自动报警警系系统设计规规范范》中华人民共和国国国国家标准GB501166—2005《火灾自动报警警系系统施工及及验验收规范》中华人民共和国国国国家标准GB502222—95《建筑内部装修修设设计防火规规范范》北京市标准DGGJJ0l---26—96《建筑安装分项项工工程施工工工艺艺规范》《自动喷水灭火火系系统施工及及验验收规范》GB502261-9966。《北京市建筑安安装装工程技术术资资料管理规规定定》DBJ001-511--20000((569号文)。《自动喷水灭火火系系统设计规规范范》GB500084-2200015.1.2质量量保保证具体环环节节1、机构设置及及领导导职责工程项目部机构构设设置:(见附表)领导职责①实施公司质量量方针针、努力实实现现质量目标标。对对所承包工工程程的质量负负全全面责任。建建建立质量保保证证体系,明明确确内部质量量职职能分工;;②向总经理负责责,对对施工进度度、工工程质量状状况况和质量体体系系文件等进进行行认真贯彻彻实实施;③加强技术改改造,推推进技术进进步步,推广采采用用新材料、新新新技术、新新工工艺,提高高施施工队伍的的技技术业务素素质质;④在总工室管管理下进进行过程、检检检验和试验验、检检验、试验验状状态、不合合格格品、纠正正和和预防措施施、包包装、搬运运、储储存、防护护和和交付等控控制制程序的实实施施;⑤组织工程投投标和合合同签订,落落落实施工任任务务。2、物资采购购(1)物资采购购主要包包括:各种种材材料、设备备和和配件的采采购购。(2)严格对厂厂(商))家的选择和和审核,保保证证设备及材材料料的质量。(3)本专业关关键性设设备和材料料有有:火灾报报警警探测器、消消消防控制设设备备、手动火火灾灾报警按钮钮、消消防专用电电话话、水系统统阀阀门、水系系统统报警阀组、水水系统喷头头,各各种钢管、各各各种电线。(4) 严格检检验关键设备备备和材料的的采采购计划::①项目经理要要对厂((商)家进行选择择和评价;;②选中的厂((商)家家必须提供供物物资的合格格证证书、检测测试试验报告;;③由项目经理理填写《设设备(材料)合同审批表表》,交设设备备部经理审审核核,报总工工程程师和总经经理理审批。(5)对其他相相关专业业队伍的设设备备和材料应应提提出的消防防相相关要求::①会发生高温温的设备备或灯具附附近近应使用防防火火材料或在在易易燃材料表表面面涂上防火火漆漆;②220V或或以上上电压的电电线线布线时,应应应采用暗配配线线(即穿在建筑筑结构内预预埋埋的暗管里)。明配线时时,应采用用明明配电线管管、电电缆桥架、电电电线槽等保保护护式配线方方法法。3、对甲方提供供的物资资设备:(1) 对于甲甲方方提供的物物资资,项目负负责责人要按照照相相应的合同同规规定和程序序的的要求进行行验验收。验收收时时要注意::①物资的品种种和数量量是否与有有关关文件相同同;;②物资是否满满足有关关规范的要要求求;③物资的检验验和试验验文件是否否齐齐全。(2)对不合合格、损损坏及未按按发发货单供给给的的物资,项项目目负责人要要记记录并单独独堆堆放或加上上标标记。并按按照照合同规定定的的方式书面面通通知业主代代表表。项目部部作作出质量记记录录予以保存存。(3) 验收后后的物物资入库保保管管好。5.2文档管管理理质量计划对项目目文文件控制应应规规定:(1) 对实施施使用的图纸纸纸、技术资资料料、施工验验收收规范、规规程程、质量检检验验评定标准准等等的提供和和控控制;项目目质质量管理使使用用的程序文文件件、工艺标标准准、操作规规程程、作业指指导导书、有关关规规定等的提提供供和控制。(2) 规定文文件分类:①受控文件;;②施工中一般般文件;;③质量月报记记录。5.3技术管管理理5.3.1保保证证工程进度度措措施1)项目施工前前,必必须作好施施工工组织总设设计计,对劳动动力力、施工机机具具、材料需需要要量等作好好充充分的准备备,才才能保证工工程程进度。如如下下图所示,为为为施工组织织总总体设计的的程程序框图。直直直观表明了了施施工组织设设计计的各个环环节节。2)施工人员准准备------公司的施工工队伍由工工程程负责人主主抓抓,各管理理人人员分工负负责责,形成强强有有力的领导导机机构。公司司要要组织好各各种种所需劳动动力力,提高劳劳动动生产率,保保保证工程质质量量,组织好好现现场各项管管理理工作。3)施工机具与与材料料准备------适应工程的的特点,按按机机具计划提提前前购制施工工机机械和专用用工工具。为配配合合超高部位位安安装,需加加工工一部分特特制制工具箱,以以以便于班组组使使用和管理理。工工长应做好好材材料计划,提提提前做好材材料料的领用和和储储备工作,保保保证及时供供应应合格的材材料料。4)技术准备工工作-------施工人员首首先要认真真阅阅读施工图图纸纸及有关技技术术资料,理解设计意意图,制定施工具具体方法。为为为保证工程程安安装质量,所有施工人人员要认真真学学习有关施施工工验收规范范及及质量检验验评评定标准和和其其它一些规规章章制度。在在施施工中,技术员要对对施工班组组进进行详细的的技技术交底,公公公司可结合合本本工程特点点,组组织进行参参观观学习。5)保证工程质质量措措施------施工方面认认真贯彻工工程程质量手册册的的执行,做到工程质质量分级管管理理,把好质量关关。在竣工工验验收时达到到一一次交验合合格格,质量达到优优良.加强现场施施工质量检检查查,配合专专业业检查人员员做做好检查,对检查结果果不合格的的要要认真讨论论分分析,制定纠正及及预防措施施。要要严格按图图纸纸施工,对对设设备要详细细地地阅读说明明书书和有关资资料料,要掌握握设设备的有关关规规范和技术术要要求,要编编写写施工方案案或或施工技术术措措施。加强强原原材料和设备备的进场检检验验工作,做做好好记录,坚坚持持不合格品品不不施工的原原则则。对相同同或或类似的设设备备、管线等等安安装,要实行统一一做法,首首先先做好“样板间”,经验收合合格后,再再统统一进行安安装装施工。对对各各类专业交交叉叉复杂的部部位位应预先组组织织图纸会审,然后再进行行施工,以以免免造成安装装后后的拆改。凡凡凡使用新材材料料、新产品品、新新技术的项项目目,应有产产品品质量标准准、鉴鉴定证明书书、使使用说明及及工工艺要求等等,经经甲方同意意、批批准后方可可使使用,甲方方按按其质量标标准准进行检查查。5.3.1保保证证工程进度度措措施施工进度、成本本、质质量是相互互对对立统一的的整整体,在这这里里我们在控控制制好成本、保保保证好质量量的的前提下提提出出专门保证证进进度的一些些措措施:①现场条件::施工用用水、用电电的的供给到位位,消消防审批及及相相关建管部部门门的开工手手续续已办妥,隐隐隐蔽工程验验收收合格。②施工工人进进场作业业前,技术术人人员定期进进入入现场对照照图图纸,认真真核核实,发现现问问题及时提提出出解决。③制定严格的的施工流流程图和详详细细的施工进进度度表,根据据工工程量大小小及及工序安排排制制定严格的的现现场用工计计划划表。④制定详细的的材料供供应计划,保保保证各类材材料料根据施工工需需要,按时时保保量供应。⑤坚持开碰头头会及周周协调会,及及及时合理调调整整人力、物物力力。⑥分项承包责责任到人人,做到包包工工、包质、包包包验。⑦验收:对每每道完成成工序坚持持验验收,尤其其是是隐蔽工程程切切实做好验验收收记录,防防止止因上道工工序序质量原因因,造造成更大损损失失。⑧加强“自检检、互检、交交接接检”的三检制度度。各班组组密密切配合,做做做好交叉施施工工作业衔接接。5.3.2保保证证施工安全全措措施(一) 安全生生产措施1、 项目设有有专职安全全员每周一一、四四早8:30分到现场进进行安全检检查查,现场并并设设有兼职安安全全员每天不不间间断的对现现场场各项安全全进进行检查。项项项目经理是是第第一安全责责任任人。2、 遵守安全全规程及施施工现场一一切切管理制度度,包包括用火制制度度、暂电制制度度等。3、 从事高空空作业的人人员要定期期进进行体检。凡凡凡患有高血血压压病,贫血血病病,癫痫病病以以及其它不不适适于高空作作业业的,不得得从从事高空作作业业。4、 从事无法法采取可靠靠防护措施施的的高空作业业人人员,必须须使使用安全带带,安安全带要栓栓在在牢固的地地方方,不得挂挂在在带有剪断断性性的物体上上。5、 严禁穿拖拖鞋,高根根鞋进入施施工工现场作业业。严严禁酒后作作业业。6、 不准从各各种脚手架架上爬上爬爬下下,禁止乘乘坐坐吊运大模模板板,楼板和和吊吊笼等非乘乘人人的垂直运运输输设备上下下。不不准在吊车车吊吊物范围下下行行走及停留留。7、 作业中禁禁止投掷物物料,清除除楼楼内物料时时应应设溜槽火火使使用垃圾桶桶。手手持工具和和零零星物料应应随随手放在工工具具袋内。8、 不得使用用拉头活动动,摇晃的的梯梯子,且必必须须使用木质质梯梯子;9、 现场行走走注意钉子子扎脚及钢钢筋筋茬拌脚。10、 剔洞槽槽时要戴防护护护镜,以免免灰灰块、凿子子毛毛刺伤眼。11、 作业中中禁止互相推推推打,闹玩玩。12、 使用电电锤、电钻、砂砂轮机等机具具,要检查地地线是否完整整、接地效果果是否可靠,使使用电钻禁止止戴手套,使使用砂轮机要要戴防护眼镜镜。13、 现场设设有的一级箱箱、二级箱,接线箱内设设有漏电保保护护开关。14、 使用手手持电动工具具具必须接带带漏漏电装置的的供供电电源。15、 电气焊焊及施工用火火火,要开用用火火证,清理理易易燃物,下下班班后进行检检查查。16、 确保安安全施工用电电电,非电气气人人员、非暂暂设设电工不得得接接、拉电线线及及电气设备备。17、 使用临临时电源,要要要符合安全全用用电规定,要要要用绝缘子子固固定。线路路距距地不低于2.5米或在人不不易接触的的部部位,禁止止在在路线上搭搭晒晒衣服、毛毛巾巾,禁止乱乱拉拉乱拖导线线,以以防触电。18、 潮湿场场所,要用安安安全电压。19、 电焊机机外壳必须接接接地良好。电电电焊机要设设单单独开关,开开开关设在防防雨雨的闸箱内内,并并能上锁,焊焊焊钳与把线线必必须绝缘良良好好,连接牢牢固固,更换焊焊条条应带手套套。潮潮湿地带工工作作,应站在在绝绝缘板或木木版版上,把线线、地地线禁止和和钢钢丝绳接触触,更更不得用钢钢丝丝绳或机电电设设备代替零零线线,更换场场地地移动把线线时时,应切断断电电源,并不不得得手持把线线爬爬梯登高。雷雷雷雨时,应应停停止露天电电焊焊作业。工工作作完毕应切切断断电源并检检查查操作地点点,确确认无起火火危危险后方可可离离开。(二) 施焊操操作中应注意意意:1、 氧气瓶、乙乙炔发生生器和施焊焊工工作点三者者互互相保持10米以上距离离。2、 氧气瓶要要防止暴晒晒,并严禁禁沾沾油。3、 乙炔发生生器不得存存放在高压压线线正下方和和人人流频繁的的路路口附近,严严严禁烟火。4、 无合格证证者在没有有专人带领领和和监护下不不得得工作。5、 乙炔发生生器及皮线线在冬季使使用用应防冻。冻冻冻结后只能能用用热水或蒸蒸汽汽解冻。6、 安全膜只只能用成品品铅薄膜,不不不得使用胶胶皮皮膜。7、 乙炔发生生器必须设设有防止回回火火的安全装装置置,保险链链,它它的零件和和管管接头不得得用用紫铜制作作。8、 氧气表及及焊割工具具上严禁沾沾染染油脂。9、 氧气瓶应应有防震胶胶圈,旋紧紧安安全帽,以以免免碰撞和剧剧烈烈震动。(三) 建全班班组安全制度度度,并设兼兼职职安全员,每每每周有一次次安安全活动。(四)施工员要要做好季节节性安全技技术术措施,并并组组织落实。建立完善的安全全管管理体系::(见附表六)(五) 成品保保护措施1、 电气设备备到场后,要要要放在于燥燥通通风的室内内,由由专人保管管,门门窗严密,并并并加锁。2、 控制元器器件,不宜宜过早安装装,待待具备一定定的的保护条件件后后再进行安装装,并有经经警警看守。3、 控制箱柜柜内的插件件,安装前前要要取下,保保管管好,不得得随随箱柜一起起安安装,以防防丢丢失。4、 电线、电电缆敷设完完毕后,线线槽槽、线盒应应立立即加盖,以以以防电缆外外露露丢失。5、 控制中心心机房,土土建必须门门窗窗装修完毕毕后后进行设备备安安装,机房房门门应加锁,重重重要地方应应派派人看护。(四) 现场文文明施工管理理理:公司全体人员要要严严格遵守文文明明施工的原原则则,积极配配合合建设单位位、总总包单位搞搞好好施工现场场文文明建设,力力力争提前按按质质、按量完完成成施工。1、严禁在施工工现场追追逐嬉闹、乱乱乱走、乱看看、乱乱写、乱画画。2、进入现场必必须佩带带出入证,穿穿穿着必须整整齐齐。3、上、下岗必必须统一一行动,不不得得随意迟到到或或早退。4、施工现场必必须经常常保持整洁洁,材材料堆放整整齐齐。5、在施工现场场经常进进行文明宣宣传传,时时加加强强施工人员员的的文明意识识。5.3.3消消防防保卫措施施1、 现场电气气焊,要办办用火证,要要要持证操作作,要要有专人看看火火,要有灭灭火火措施(如消防器具具或备水桶)上下班要即即时拉闸,闸闸闸门设锁。2、 工具房使使用电炉子子要办用火火证证,接线要要安安全,闸具具要要齐全,上上下下班出去干干活活都要拉闸闸。3、 冬季生火火炉,要注注意烟道畅畅通通。要办用用火火证,下班班做做到真正灭灭火火。并四周周浇浇水,以防防着着火事故。4、 炉子即电电炉旁应清清理干净,保保保持无易燃燃烧烧物,以防防火火灾发生。5、 现场消防防器材不许许乱动及损损坏坏,不得占占用用消防交通通要要道。5.3.4成成品品及设备部部件件的保护措措施施(一) 经除锈锈、刷油防腐腐腐处理后的的管管材、型钢钢、托托吊卡等金金属属制品应码放放在有防雨雨措措施,运输输畅畅通的专用用场场地。(二) 安装好好的管道,不不不得用做支支撑撑、系安全全绳绳、放脚手手板板和蹬踩。(三) 搬运管管、机具及施施施焊时,要要有有具体防护护措措施,不应应脏脏污、砸坏坏已已经做好的的墙墙面、地面面、门门窗等。(四) 轻质墙墙上剔洞作支支支卡时,必必须须细心,剔剔洞洞要合适,不不不要将板墙墙剔剔裂。(五) 不得在在楼板上或抹抹抹好的地面面上上剁管、捻捻口口或制作小小工工具。(六) 各种端端子箱安装好好好,应将箱箱门门封好,以以免免损坏。(七) 套丝机机、切管机、电电锤等机具设设备,用后应应当清除杂物物、尘土、油油垢,以保证证其正常运行行。5.3.5环环境境保护措施施施工现场文明施施工工管理必须须执执行上级颁颁发发的场容管管理理及有关规规定定,各施工工队队要有一名名管管理人员主主抓抓,施工员员分分区负责,各各各施工班组组均均有一人负负责责文明施工工。1、施工队对现现场文明明施工管理理要要统一布置置,统统一安排,每每每个班组要要建建立岗位责责任任制。2、工长施工交交底时必必须对文明明施施工提出具具体体要求,重重要要部位要有有切切实可行的的具具体施工及及书书面交底。3、操作地点周周围必须须做到整洁洁,干干活脚下清清,活活完料尽,剔剔剔凿、保温温完完成后要随随时时清理干静静,将将废料倒在在指指定地点。4、上道工序必必须为下下道工序积积极极创造优良良的的条件,及及时时做到预留留、预预埋和暗配配工工作。5、施工现场堆堆放的成成品、材料料要要整齐,以以免免影响地区区景景观。5.3.6冬冬季季施工措施施(一) 冬季施施工措施地下室冬季施工工的的特点:地下下室通风、排排排烟不畅;;用用火增多,用用用电量增多多;;因此依据据以以上特点,应应应采取以下下措措施:加强强对对工人和住住户户的防火教育,提提高防火意意识识;配备灭火火器材;增强易燃、可可可燃烧材料料的的管理;检查查地下一层层管管道保温,防防止水源主主管管结露、冻冻结结。5.3.7现现场场文明施工工管管理(一) 现场文文明施工管理理理:公司司全全体人员要要严严格遵守文文明明施工的原原则则,积极配配合合建设单位位、监理单位搞好好施工现场文文明建设,力力争提前按质质、按量完成成施工。1、严禁在在施施工现场追追逐逐嬉闹、乱乱走走、乱看、乱乱乱写、乱画画。2、进入现现场场必须佩带带出出入证,穿穿着着必须整齐齐。3、上、下下岗岗必须统一一行行动,不得得随随意迟到或或早早退。4、施工现现场场必须经常常保保持整洁,材材材料堆放整整齐齐。5、在施工工现现场经常进进行行文明宣传传,时时时加强施施工工人员的文文明明意识六、工程实施6.1工程实实施施步骤施工过程管理是是整整个质量计计划划的核心部部分分,通过施施工工过程管理理一一系列活动动,使使图纸变为为实实物工程。施施施工过程管管理理包括施工工进进度控制和和施施工质量控控制制两个部分分。(1) 施工进进度度控制对工程总进度计计划划和单项(位)工程进度计计划等做出出规规定。(2) 施工质质量量控制规定工程实施全全过过程各阶段段的的施工方法法、施施工平面图图、各各项资源需需用用量计划、各各各项施工准准备备工作计划划等等。主要包包括括以下阶段段::①施工准备;;②管线及接线线箱(盒盒)施工;③火灾探测器器安装;;④火灾报警控控制设备备安装;⑤消防专用通通信系统统安装;⑥自动灭火系系统安装装;⑦消防联动控控制系统统安装;⑧火灾自动报报警系统统及联动功功能能的调试与与试试验;⑨竣工验收。6.1.1工程程实实施阶段工程施工原则上上按按照深化设设计计方案进行行,如如有个别需需要要修改之处处,必必须会同建设设单位、监理理审定,以以设设计变更通通知知单的形式式通通知乙方。6.1.2纠纠正正和预防措措施施(1) 不合格格的原因调查查查及分析。对对对施工全过过程程、操作、质质质量记录、用用用户意见进进行行调查分析析,消消除不合格格工工程项目的的潜潜在原因。(2) 纠正措措施:①对不合格工工程项目目进行分类类统统计,建立立质质量事故统统计计台帐;②提出不合格格质量分分析报告和和纠纠正措施;;③将有效措施施标准化化,防止不不合合格的再发发生生。(3) 执行纠纠正措施的记记记录。6.1.3质质量量记录质量记录是为已已完完成的活动动或或达到的结结果果,提供客客观观证据的文文件件。具体是是为为质量要求求已已经满足的的程程序和要素素运运行的有效效性性提供证据据。它它的作用是是为为证实、追追溯溯以及采取取预预防或纠正正措措施提供客客观观证据。6.1.4检验验和和试验在工程施工过程程中中,检验和和试试验是一项项十十分复杂而而又又重要的问问题题,它涉及及面面广,每道道工工序完工后后只只有检验合合格格才能转入入下下道工序;;对对进场的材材料料、构件、设设设备等也要要进进行严格检检验验、试验。针针针对工程项项目目每项有检检验验、试验要要求求项目做出出明明确规定。主主主要包括以以下下内容:(1) 材料、设设备进场时时,由业主主代代表、监理理和和施工单位位三三方进行验验收收。(2) 当分项项工程完工后后后,进行预预检检、隐检、测测测试和试验验。(3) 当出现现不合格品时时时,必须进进行行纠正后,再再再进行复验验,使使其符合施工工质量和设设计计要求。(4) 所有预预检、隐检、测测试、试验记记录等监理或或业主代表认认可、签字。七、工程施工规规范范及工艺7.1消防报报警、联联动系统部部分分7.1.1施施工工工艺流程程施工流程:预制制——预埋管检查-局部配线管-穿线-测试-设备安装-调试-系统验收7.1.2施施工工技术要求求报警电线采用ZZRR-RVSS22*1.0;弱电电源源线及控制制线线采用ZR-RVVS2*1.5,不同种类类按颜色区区分分,施工时时具具体技术要要求求如下:根据施工图,为为达达到科学施施工工以提高工工效效,在配管管前前尽量多制制作作预制件。1. 扫管(1) 要在装装修拆模后(((或同步)进行。(2) 模板拆拆除后,先将将将盒内堵料料掏掏出,如发发现现有灰浆堵堵管管盒现象,必必必须及时处处理理,预计砼砼养养护期过后后,给给处理上增增加加难度,同同时时也避免破破坏坏结构。(3) 将管口口打开(管堵堵保留),用18#钢代线或16#铁代线绑上上破布或棉棉丝丝将管内污污物物扫净,然然后后取下布或或棉棉丝将管堵堵盖盖上,将盒盒子子用简易盒盒盖盖封好,以以防防进入污物物。2. 穿线(1) 管内穿穿线不允许在在在管内有接接头头,接线盒盒甩甩出线为15-200cm。(2) 穿线时时要将线顺直直直,放平,管管管内不得有有背背扣,打结结现现象。(3) 如穿带带轴的线时,可可用放线架将将轴支起,然然后放线。(4) 穿线时时可用滑石粉粉粉,不得使使用用其他油类类。(5) 不同电电压等级导线线线不得穿在在同同一管内。3. 设备安装装(1) 探测器器、报警按钮钮钮、消防电电话话插孔等安安装装时要按照照施施工图,现现场场定位划线线,在在吊顶上安安装装时,要注注意意纵横成排排对对称。如遇遇风风口距离小小于于1.5米时,要请请设设计院办变变更更通知后,再再再移位,不不得得自行更改改设设计。(2) 吊顶下下安装探测器器器等设备时时其其与主管连连接接金属软管管长长度一般不不得得超过2米。(3) 探测器器安装时要注注注意确认灯灯的的位置应安安装装在使人能能够够比较方便便看看到的位置置,成成排探测器器的的确认灯方方向向应一致(比如走廊中中的)。(4) 手动按按钮,电话插插插孔使用专专用用接线盒,以以以便设备安安装装时,螺丝丝对对准安装孔孔,设设备安装要要平平正,装卸卸板板面要与墙(板)面平齐,安安装高度距距地地1.4米。(5) 消防设设备箱、端子子子箱,安装装为为壁挂,一一般般安装高度0.3-1.4米,(设计标有尺尺寸的除外),用膨胀螺螺栓固定,安安安装完毕要要用用水平尺找找正正,如安装装高高度有变化化,按按变更后执执行行,消防设设备备箱、端子子箱箱、模块箱箱为为非标产品品,具具体箱体尺尺寸寸待选定设设备备产品厂家家后后定,箱体体安安装位置一一般般在竖井内(设计已确定定了位置的的除除外)。(6) 接线A. 箱、柜、盒盒内接线为为端端子压接,独独独股导线在在压压接时,应应将将导线用剥剥线线钳将导线线剥剥掉外部导导线线绝缘层,长长长度按照端端子子的大小而而定定,端子压压接接时,导线线不不得裸露。然然然后用螺丝丝刀刀将螺丝拧拧在在导线插入入的的端子内,注注注意螺丝不不能能拧过度,要要要拧到拧不不动动即可,防防止止将压线螺螺丝丝拧过劲使使之之溢扣。B. 多股导线线压压接时,要要进进行涮锡、涮涮涮锡要饱满满,压压接要牢固固。7.1.3工工程程调试验收收调试:在设备安安装装完成后进进行行。(1) 一般由由我方或供货货货商负责调调试试,我方要要积积极进行或或配配合调试工工作作,出现问问题题要及时找找有有关单位协协调调解决。(2) 单机调调试。各消防防防有关系统统应应先自身单单机机调试,在在确确保单机调调试试完好的情情况况下进行联联调调。(3) 联调。由由总包组织织进行联调调工工作,需参参加加的联调专专业业系统如下下::A. 消火栓系系统统:B. 水喷淋系系统统:C. 报警及联联动动系统(含手动报警警按钮和声光光报警系统);D. 其它有关关系系统。上述系统的施工工单单位必须派派专专业人员参参加加联调工作作,统统一听从指指挥挥,在联调调中中如发现问问题题,上述各各单单位应分别别写写出整改意意见见,相关单单位位组织整改改后后进行由业业主主、监理等等单单位参加的的验验收,验收收合合格后,写写出出竣工预验验报报告,由各方方签字,由我我方协助业业主主报消防部部门门进行消防防工工程的最后后验验收工作。7.2消防喷洒洒系系统部分7.2.1施施工工工艺流程本工程水喷淋系系统统管网,根根据据设计要求求,全全部采用镀镀锌锌焊接钢管管,丝丝扣连结,施工工艺流流程如下::安装准准备备----套丝----干管安装----报警阀安装----立管安装----喷淋干支管管及水流指指示示器安装----管道试压----管道冲洗----水流指示器器安装及二二次次安装报警警阀阀----喷淋头安装装。(1) 施工人人员必须经过过过专业培训训,并并有详细的的技技术交底。(2) 系统管管材及其他所所所有材料和和组组件在安装装前前必须经过过严严格的检验验及及复查,不不合合格的产品品严严禁使用。(3) 管道在在安装前必须须须清除管内内的的杂物,并并注注意保持管管内内清洁,安安装装位置必须须符符合设计要要求求。(4) 管道连连接采用丝扣扣扣连接方式式时时,丝扣质质量量必须符合合有有关要求,填填填料用麻丝丝铅铅油,丝扣扣不不得有超过10%的缺扣或或断丝,外外露露丝扣在管管网网试压验收收后后涂刷油漆漆。(5) 管道支支、吊架、防防防晃支架的的制制作及安装装必必须符合规规范范要求,当当管管道改变方方向向必须设置置防防晃支架。(6) 管道穿穿过墙体或楼楼楼板时应加加设设套管,且且接接缝不得位位于于套管内,管管管道穿过变变形形缝时,应应加加设柔性管管。(7) 管网安安装完毕后,应应按标准进行行管道冲洗和和水压试验。(8) 每层喷喷水支管管网网网必须有0.002的坡度坡向向给水立管管。(9) 机器连连接时,应对对对机器连接接件件密封面及及密密封垫片进进行行外观检查查。对对口应保持持平平行,
温馨提示
- 1. 本站所有资源如无特殊说明,都需要本地电脑安装OFFICE2007和PDF阅读器。图纸软件为CAD,CAXA,PROE,UG,SolidWorks等.压缩文件请下载最新的WinRAR软件解压。
- 2. 本站的文档不包含任何第三方提供的附件图纸等,如果需要附件,请联系上传者。文件的所有权益归上传用户所有。
- 3. 本站RAR压缩包中若带图纸,网页内容里面会有图纸预览,若没有图纸预览就没有图纸。
- 4. 未经权益所有人同意不得将文件中的内容挪作商业或盈利用途。
- 5. 人人文库网仅提供信息存储空间,仅对用户上传内容的表现方式做保护处理,对用户上传分享的文档内容本身不做任何修改或编辑,并不能对任何下载内容负责。
- 6. 下载文件中如有侵权或不适当内容,请与我们联系,我们立即纠正。
- 7. 本站不保证下载资源的准确性、安全性和完整性, 同时也不承担用户因使用这些下载资源对自己和他人造成任何形式的伤害或损失。
最新文档
- 产品交付周期确保目标实现承诺书3篇范文
- 商务谈判技巧及方案制定指南
- 2026年平面设计兼职与全职的利弊分析与选择
- 某道路改造施工组织设计方案
- 请假扣年终奖协议书
- 网吧布线施工方案(3篇)
- 检查车施工方案(3篇)
- 定制刻字活动方案策划(3篇)
- 皮影公园活动策划方案(3篇)
- 灌溉用水施工方案(3篇)
- 2025年中国纳米功能电池项目创业计划书
- 雅马哈DTX430K电子鼓中文说明书
- 2025年及未来5年中国杂粮行业市场调查研究及投资前景预测报告
- 小学五年级音乐期末考核方案
- 三年级语文下册阅读理解练习题共45篇
- 驾驶员雨季安全行车培训课件
- 《环境法(第七版)》课件全套 周珂
- 放射性皮肤损伤护理指南
- 关于项目物业退场的告知函(致街道等部门)
- 2025年设备维修考试题库
- 五金公司质量管理制度
评论
0/150
提交评论