版权说明:本文档由用户提供并上传,收益归属内容提供方,若内容存在侵权,请进行举报或认领
文档简介
第八章质谱法MassSpectroscopy(MS)质谱仪的一般结构真空系统进样系统离子检测器数据系统质量分析器离子源大气样品机械泵,分子涡轮泵,扩散泵,离子泵,升华泵气体:气相色谱仪(GC/MS)液体:液相色谱仪(LC/MS)固体:固体进样杆(DIP,DCI)电子倍增器,多通道板检测器光电倍增管,阵列检测器通常的离子化方法电子轰击离子化 EI化学电离离子化 CI正化学电离离子化 PCI负化学电离离子化 NCI大气压力离子化 API电喷雾离子化 ESI大气压化学电离离子化 APCIGC/MSLC/MS离子化和碎片离子化硬无碎片有碎片APIEICI软质量分析器四极杆~80%的台式质谱仪(~3000/年)HP,PE,TMQ,Shimadzu离子阱~20%的台式质谱仪(~700/年)Varian,TMQ飞行时间(ToF)目前用户较少(50-60/年)Leco,Micromass,TMQ扇形磁场通常不是台式仪器四极质量分析器++++飞行时间质量分析器++++所有离子同时启动小的离子移动速度快测量已知距离下的速度(飞行时间)扇形磁场质量分析器+++离子通过变化的磁场和电场被传输ElectronImpactIonization(EI)e-e-e-e-e-SamplefromGCfilament++++FragmentionQPPositiveChemicalIonization
(PCI)fromgascylinderfilamente-e-e-e-e-QPCH4
CH5+C2H5+SamplefromGCH+-CH4[M+1]-C2H4PositiveChemicalIonization(PCI)Reagentgasmoleculesareionizedfirst.Samplemoleculesareionizedmainlyby損rotontransfer?Quasimolecularionseasilyproducedusefulformolecularweightverification.
+PCIspectrumMethylstearateM.W.298ComparisonofEIandPCIEImodePCImodeFragmentMolecularweightNegativeionformationbyelectroncapture(associativeresonancecapture)
MX+e-(~0eV)MX-.X:positiveelectronaffinitypartCH4e-MXCH4+CH3+HCH4CH4CH4e-MX-质谱图的样子?EI和CI的质谱图50100150200250300350400450500550m/z0100%51051151250100150200250300350400450500550m/z0100%241213510242EIOOOCF3CF3CH3NCI…扫描50到300amu流入质谱仪的化合物质谱图...60801001201401601802002202402602803000100%240241断裂机理1.σ断裂2.α断裂5.Mclafferty重排ConfigurationofGCMS
MassSpectrometerGasChromatographInterfaceIonsourcebox
IonSourceDesign
-Increasedionizationefficacy-InterfaceThesampleseparatedbyGCwillbeintroducedthroughthisinterface.
FilamentIongeneratedbyfilamentwillgivetheelectronimpacttothesampletoproducethesampleionization.Ionsourcebox
IonLens
-Highionintroductiontomassanalyzer-
Thisionlensisfunctioningforeffectiveintroductiontomassanalyzer.OptimizationforadjustmentofthisionlenswillbedonebyPCautomatically.
QuadrupoleRod
-MinimizelossesintransittotheQuadrupole-MainRodSpecificiononlycanbepassedbytheelectronicfieldintoQuadrupoleRodwhichiscontrolledbyPC.PreRodFromionsourceTodetectorrotarypumpturbomolecularpump(151L/sec)turbomolecularpump(151L/sec)rotarypumpGoodvacuumsystem-MinimizelossesintransittotheQuadrupole-
TurboMolecularPump
AircooledandoilfreeTurbomolecularPump(TMP)withlubricantimpregnatedceramicbearingsismaintenancefreeforupto25,000hours.Provideshighqualityvacuuminlessthan5mins.Iondetection
+7.5kV-+e--0.7~3.0kVAMP-7.5KV+e--0.7~3.0kVAMPe-NegativeiondetectionPositiveiondetectionGCMS-QP5050ANCIsensitivity200fgHexachlorbenzeneNCIspectrum
Masschromatogramofm/z284OFN(octafluoronaphthalene)NCIscanmodeOutstandingHighSensitivity
scanrangem/z60-310,0.5secinterval200fgS/N>30
GCMS-QP5050ANCIpesticidesdate310pgCyanophosNCI
massspectrumphosphoruspesticides10pgComparisonbetweenEIandNCIextractfromcabbage(pesticidesadded)EIscanningmodeNCIscanningmodeComparisonbetweenEIandNCIextractfromcabbage(pesticidesadded)PrincipleofProgramedtemperaturevaporize(PTV)PTV
100CsplitMS50-250CSolventwillbevaporizedandexhausted.Samplewillbeconcentrated.OptimizationofPTVconditionsSelectionofpackingmaterialsTenaxGC 20%OV-120%OV-1720%Dexil300ShincarbonACarbopackC TraptemperatureDesorptiontemperatureTemperatureprogramVery-Large-VolumeInjectionusingPTV
EffectofTemperatureonTrapefficiencyVery-Large-VolumeInjectionusingPTV
TemperatureandSplitratioProgramVery-Large-VolumeInjectionusingPTV
2ppbeachPesticidesinn-hexane1000uLInjectionAnalyticalConditions
GC17AVer.2
DB130mX0.25mm
50C(4)-160C-280C
20C/min5C/min
PTV
70C(1)-100C(1)-280C
30C/min250C/min
WiderangeFTD1pA280C
CarriergasHe150kPa
PrecolumnTenaxGCFeaturesofGCMSQP-5050AOutstandinghighsensitivityExtendedmassrangeupto900amuVersatileMode-EI/PCI/NCI/DICompactDesignEasyOperationusingWindowsSoftwareEasytuning-PFTBAbuiltinstandardEasymaintenanceAnalysisofCoconutoilMSSpectrumofC48DIoptionThedirectinletoptionallowslessvolatileorthermallylabilesamplestobedirectlyintroducedintothemassspectrometer.MixturesofcompoundswhichhavedifferentboilingpointscanbepositivelyidentifiedbyprogrammingtheDIprobetemperature.Applicationusing
directinletprobeFront-openionchambersystem
-easymaintenance-
DualFilamentsSystem
-easymaintenance-
LCMS-QP8000Validation,ProductivityandMassDetectionWhatkindofbenefits
LC/MSuserscanget?PowerfulqualitativecapabilitySelectivequantitativecapability
M/ZM/ZM/ZWhatkindofbenefits
LC/MSuserscanget?PowerfulqualitativecapabilitySelectivequantitativecapability
A:100D:150B:100C:150m/z=150TICm/z=100ABCDHPLCMSNewShimadzuLCMS
QP-8000QP-8000isLC/MSwithAPIinterfacewhichisdesignedtobearoutineLCdetectorinournewVPseriesHPLCsystem.LCMSInterfaceCurvedDesolvationLine(CDL)DeflectorProbeSprayChamberSkimmerLensStack
RPTMP1TMP2QuadrupoleAPISprayChamberAPISprayChamberESIProbe(EasytochangetoAPCIProbe)APIProbeESIandAPCIprobesareincludedasstandard.Theycanbeappliedtovariouskindsofsamples.Allyouhavetodotoswitchtheionizationmethodistochangetheprove.APCIprobeESIProbeMobilephase,LCflowrateandNebulizerflowrateslightlyinfluencespraycondition.Youcanadjusttheprobepositiontothebestforeachcondition.TheAPCIprobecontainscoronadischargeneedle.SononeedtochangetheAPIspraychamber.EasyMaintenanceSkimmerLensstackaccessSprayChamberAccessYoucanpickitupfromuppersidewithoutanytools.Youcanremovethespraychamberfromthefrontside.Itwillbeeasytowashthispartafteranalysis.StandardSyringePumpSyringefordirectsampleinjectionSyringeforstandardsampleofcalibrationLCMSApplicationMassSeparation
Column:STRODS-II(2.0mmI.D.x150mm)Mobilephase:65%acetonitrile-watercontaining0.1%formicacid,0.2ml/minMaltoseTIC387225195GlucoseXyloseAnalysisofmacrolideantibioticsUV210nmMDMSIMSPM-I,IISPM-IIIOMDHEMMDMSummaryLCMS-QP8000isa
CompactBenchTop
LiquidChromatographwithhighperformancesEasyOperationandMaintenance
usingCLASS-8000softwareSelfdiagnosticfunctionsUserloginandsecuritydefinedbyaccesslevels.OLEcustomreportgeneration
Affordableprice
质谱图和色谱图?如果我们注意这个区域...色谱图?1.251.501.752.002.252.502.753.003.25Time50100%TIC在此的细微观察是由许多点组成的...色谱图-放大22.242.262.28Time78100%TIC每个点相对于质量分析器的一个扫描(质谱图)...60801001201401601802002202402602803000100%240241质谱图
每个点有一张唯一的质谱图色谱图上的质谱图数据观察-色谱图样品运行中的每秒我们可获得一张或数张质谱图通常是把检测到的离子叠加在一起获得一个唯一的总的数值这些总的数值然后排列在一起(点对点)产生一个类似的色谱图(TIC)...每次扫描加和所有的离子得到...总离子色谱图(TIC)数据观察-色谱图我们也能显示某一张质谱图
这让我们一个化合物的信息…
…质谱图质量色谱图和TICTICMass2401.401.601.802.002.202.402.602.803.00Time0100%0100%240.271.41e5TIC4.67e5
消除背景的影响
增加信噪比
分离共流出物峰数据观察-选择离子色谱图TIC图上显示的两个接近的流出峰,但每个峰是具有不同质谱指纹的不同化合物...数据观察-选择离子色谱图11.0012.00Time0100%TIC1.57e5数据观察-选择离子色谱图100200300400500600m/z0100%254.2194.2507.3334.3399.7100200300400500600m/z0100%194.2580.4402.2226.2460.211.0012.00Time0100%TIC1.57e5分离共流出物峰10.5011.0011.5012.0012.50Time0100%0100%0100%254.235.81e4194.206.14e4TIC1.57e5质量254质量194TIC选择离子色谱图提取出离子给出更好的信噪比消除背景影响分离共流出物峰
提取出离子也能用于:
峰的跟踪
准确定量峰跟踪的实例0100%TIC2.21e61.002.003.004.005.006.00Time0.525.653.823.251.672.005.594.954.255.725.81爆炸混合物的TIC哪一个是HMX?HMX的质谱图峰跟踪406080100120140160180200220240260m/z0100%8472596911389106237131205158分子离子峰峰跟踪质量色谱图m/z237TIC1.002.003.004.005.006.007.008.009.00Time0100%0100%2.000.525.653.823.251.672.004.954.255.81分离相邻峰的能力分子离子[M+H]+M.+[M-H]-
分辨率FWHM10%峰谷m/M[M+H]+m/zintensity质谱分辨率复合技术GC/MS气相色谱-质谱LC/MS液相色谱-质谱MS/MS质谱-质谱MS-MS方法MS1MS2
固定 扫描
子离子
扫描 固定
母离子
扫描 扫描
温馨提示
- 1. 本站所有资源如无特殊说明,都需要本地电脑安装OFFICE2007和PDF阅读器。图纸软件为CAD,CAXA,PROE,UG,SolidWorks等.压缩文件请下载最新的WinRAR软件解压。
- 2. 本站的文档不包含任何第三方提供的附件图纸等,如果需要附件,请联系上传者。文件的所有权益归上传用户所有。
- 3. 本站RAR压缩包中若带图纸,网页内容里面会有图纸预览,若没有图纸预览就没有图纸。
- 4. 未经权益所有人同意不得将文件中的内容挪作商业或盈利用途。
- 5. 人人文库网仅提供信息存储空间,仅对用户上传内容的表现方式做保护处理,对用户上传分享的文档内容本身不做任何修改或编辑,并不能对任何下载内容负责。
- 6. 下载文件中如有侵权或不适当内容,请与我们联系,我们立即纠正。
- 7. 本站不保证下载资源的准确性、安全性和完整性, 同时也不承担用户因使用这些下载资源对自己和他人造成任何形式的伤害或损失。
最新文档
- 2025年个旧市医共体卡房分院招聘备考题库及答案详解一套
- 2025年天津市政建设集团有限公司面向社会公开选聘总法律顾问备考题库及答案详解一套
- 2025年《中国邮政报》社有限公司公开招聘备考题库及完整答案详解一套
- 华能新能源股份有限公司陕西分公司2026年应届毕业生招聘备考题库及完整答案详解一套
- 2026年威海市环翠区民兵训练基地公开招聘事业单位工作人员备考题库及答案详解1套
- 2025年晋江市新塘街道办事处公开招聘编外人员的备考题库及完整答案详解1套
- 2025年复旦大学附属妇产科医院招聘超声科主任备考题库带答案详解
- 2025年哈尔滨铁道职业技术学院公开招聘教师备考题库及参考答案详解
- 中国人民财产保险股份有限公司漳州市分公司2026校园招聘备考题库及一套参考答案详解
- 2025年宁波能源实业有限公司招聘备考题库参考答案详解
- 核物理与辐射安全智慧树知到期末考试答案章节答案2024年哈尔滨工程大学
- 统计学贾俊平第5章概率与概率分布
- 游戏动漫人体结构造型手绘技法
- 保健食品及其原料安全性毒理学检验与评价技术指导原则
- 建筑企业经营管理课件
- 捷盟-03-京唐港组织设计与岗位管理方案0528-定稿
- 基于SystemView的数字通信仿真课程设计
- 物业二次装修管理规定
- GB 10133-2014食品安全国家标准水产调味品
- 采气工程课件
- 工时的记录表
评论
0/150
提交评论