文档简介

14644-1:2015(E)14644-1:2015(E)#/58图中X图中X计数时间(分钟)Y计数限度(粒子数)■观察计数值的上限□观察计数值的下限KEYXCounttime(min)YCountlimits(particles)■upperlimitfortheobservedcount□lowerlimitfortheobservedcountFigureD.2—Graphicalrepresentationofthepassorfailboundariesforsequentialsampling图D.2-顺序取样法的通过不通过边界线图示ComparethecumulativeobservedcountandtheupperandlowerlimitsandapplytheproceduredescribedinD.3.比较累计观察计数值与上限和下限值FallsituationseeTableD.3不合格情形参见表D.3T(min)时间(分钟)T(S)时间(秒)Expectedcount,E要求的计数ELimitsforthecumulativeobservedcount累计观察计数限度Observedcountduringinterval间隔中观察到的计数Cumulativeobservedcount,C累计观察的计数值Result结果Upper,Cfail上限Lower,Cpass下限1601.05NA22Continue继缕21202.07NA35Continue继续31803.08NA16Continue继续42404.09006Continue继续53005.0101511FAIL不合格TableD.3—Examplesequentialsamplingparticlecounts表D.3一顺序取样法粒子计数举例Theexpectedcountprovidedinthefirstmeasurementis1,0;thecumulativeobservedcountisjudgedto"FAIL"whenitisgreaterthanorequalto5.However,whenthecumulativeobservedcountisbetween0and5,itcannotbejudged.Inthepresentexample,thesamplinghastobecontinued.Whenthesamplingiscontinued,thecumulativeobservedcountincreases.However,itiseasytojudgebecauseboththeexpectedcountandthereferencecountincrease.Inthe5"measurement(f=300s),thecumulativeobservedcountis11andexceedstheupperlimit(10).ThenitisjudgedtoTAIL."在第一次测量中给出的计数值为1.0:累计观察计数值大于等于5时,则判定为"不合格,但是,如果累计观察计数在0-5之间,则不能做出判定。在给出的例子里,必须继续取样。如果继续取样后,累计观察计数值增加。在第5次测量中(t=300秒),累计观察计数为11,而要求的上限为(10),因此这时判定为"不合格\PasssituationseeTableD.4 合格的情形参见表D.4TableD.4—Examplesequentialsamplingparticlecounts

表D.4--顺序采样法粒子计数举例T(min)时间(分钟)T(S)时间(秒)Expectedcount,E要求的计数ELimitsforthecumulativeobservedcount累计观察计数限度Observedcountduringinterval间隔中观察到的计数Cumulativeobservedcount,C累计观察的计数值Result结果UPper上限,CfailLower卜限,Cpass1601.05NA00ContinUe继续21202.07NA00Continue继续31803.08NA00Continue继续42404.09000PASS合格Theexpectedcountprovidedinthefirstmeasurementis1,0,thecumulativeobservedcountisjudgedtot*FAIL"whenitisgreaterthanorequalto5.However,whentheobservedcountisbetweenθand5,itcannotbejudged.Inthepresentexample,thesamplingiscontinued,butthecumulativeobservedcountdoesnotincrease.Inthe4thmeasurement(/=240s),thecumulativeobservedcountis0andisequaltothelowerlimit(0).Thenitisjudgedto"PASS."在第一个测量阶段要求的计数值为1∙0,累计观测计数值加果大于等于5,则判定为"不合格)但是,如果观测计数值在0-5之间,则无法判定。在本例中,继续取样,但累计观测计数值并未增加。在第4个测量阶段时(t=240秒),累计观测计数值为0,等于最低限度值(0)。因此判定为"合格工AnnexE附录E(informative)仅供参考Specificationofintermediatedecimalcleanlinessclassesand

particlesizethresholds中间洁净级别标准和粒径阈值E.1IntermediatedecimalcleanlinessclassesE.1中间洁净级别Ifintermediatedecimalcleanlinessclassesarerequired,TableE.1shouldbeused.如果需要使用中间洁净级别,应使用表E.1。TableE.1providesthepermittedintermediatedecimalaircleanlinessclasses.Uncertaintiesassociatedwithparticlemeasurementmakeincrementsoflessthan0,5inappropriate,andthenotesbeneaththetableidentifyrestrictionsduetosamplingandparticlecollectionlimitations.表E.1给出了允许的中间洁净级别。粒子测量中的不确定度使得小于0.5的增量并不恰当。表卜的注科指出「由于取样的粒子收集的局限性带来的限制。TableE.1——Intermediatedecimalaircleanlinessclassesbyparticleconcentration表E.1-按粒子浓度划分的中间空气洁净级别Concentrationofparticles(particles/m3)a粒广浓度(个/、工方K)IOSClassnumber(N)ISo级别号(N)ISOClass1.5[32]bddddeISOClass2.5316[75]b[32]bddeISOClass3.53.160748322111deISOClass4.531.6007.4803.2201,110263eISOClass5.5316.00074.80032,20011,1002,630eISOClass6.53,160,000748,000322.000111,00026,300925ISOClass7.5CCC1,110,000263,0009,250ISOClass8.5fCCC11,100,0002.630.00092.500Allconcentrationsinthetablearecumulative,e.g.forISOClass5,5,the11100particlesshownat0.5μmincludeallparticlesequaltoandgreaterthanthissize.在表中的所仃浓度均为累积浓度,如,ISo第5.5级,在0.5Pm时显示IlJOo的粒G包括了大于和等于此粒径的所有粒子。These∞ncentrationswillleadtolargeairsamplevolumesforclassification.SeeAnnexD,Sequentialsamplingprocedure.这些浓度会使得级别的取样体积很大。参见附录D,顺序取样法.Concentrationlimitsarenotapplicableinthisregionofthetableduetoveryhighparticleconcentration.由于粒子浓度很高,浓度限度不适用于表中此区域。Samplingandstatisticallimitationsforparticlesinlowconcentrationsmakeclassificationinappropriate.在低浓度时,取样和统计学局限使得分组并不恰当.Sample∞llectionlimitationsforbothparticlesinlowconcentrationsandsizesgreaterthan1μmmakeclassificationinappropriate,duetopotentialparticlelossesinthesamplingsystem.由卜取样系统可能的粒子丢失,在低浓度或粒径人Flpm时,样品采柴局限性使得分级并不恰当。Thisclassisonlyapplicableforthein-operationstate.本级别仅适用J:动态测试.E.2Intermediateparticlesizes中间粒径Ifintermediateparticlesizesarerequiredforanyintegerordecimalclass,Formula(E.1)maybeusedtodeterminethemaximumparticleconcentrationattheconsideredparticlesize:如果有任何十位整数或中间数级别需要有中间粒径,可以使用公式(E∙1)来计算所考虑的粒径的最大粒子浓度。… /人2°8Cn=IONX (E.1)whereCCiSthemaximumpermittedconcentration(particlespercubicmetre)ofairborneparticlesthatareequaltoandgreaterthantheconsideredparticlesize.CCiSroundedtothenearestwholenumber,usingnomorethanthreesignificantfigures;Λ/istheISOClassnumber,whichshallnotexceedavalueof9orbelessthan1;Distheconsideredparticlesize,inmicrometres,thatisnotlistedinTable1;Kisaconstant,0,1,expressedinmicrometres.其中Cn是大于等于要考虑的粒径的空气悬浮粒子的最大允许浓度(个/立方米)。Cn修约至最近的整数,保持有效位数不大于三位:N是ISo级别,不应大于9或小于1;D是所考虑的粒径,单位微米,在表1中未列出:K为常数0.1,单位微米AnnexF附录F(informative)仅供参考Testinstruments测试仪器F.1Introduction概述ThisannexdescribesthemeasuringapparatusthatshouldbeusedfortherecommendedtestsgiveninAnnexesA,CandD.本附录描述了附录A、C和D中给出的建议测试中所应使用的测量仪器。Inthisannex,datagiveninTablesF.1andF.2indicatetheminimumnecessaryrequirementsforeachitemofapparatus.Measuringapparatusshouldbechosensubjecttoagreementbetweenthecustomerandsupplier.在本附录中,在表F.1和F.2中给出的数据表示的是仪器各项目所应达到的最低要求。客户和供应商应就测量仪器的选择达成一致。Thisannexisinformative,andshouldnotpreventtheuseofimprovedapparatusasitbecomesavailable.本附录仅供参考,如果仪器在将来被改进,本附录并不会禁止使用。Alternativetestapparatusmaybeappropriateandmaybeusedsubjecttoagreementbetweencustomerandsupplier.也可以使用其它客户和供应商之间达成一致的测量仪器来代替。F.2Instrumentspecifications仪器标准ThefollowinginstrumentsshouldbeusedfortherecommendedtestsgiveninAnnexesA,CandD:附录A、C和D中给出的建议测试应使用以下仪器:lightscattering(discrete)airborneparticlecounter(LSAPC);光散射(不连续)空气悬浮粒子计数器(LSAPC)NOTEThespecificationsfortheLSAPCaregiveninISO21501-4:2007.(1]注:ISo2150142007中给出了LSAPC的标准。discrete-macroparticlecounter;不连续大颗粒计数器time-of-flightparticlesizingapparatus;飞行时间粒径测量仪microscopicmeasurementofparticlescollectedonfilterpaper.SeeASTMF312-8.[3]采用滤纸采集的粒子的显微测量,参见ASTMF312-8oThetermsanddefinitionsfortheseinstrumentsaregiveninClause3.第3款中给出了这些仪器的术语和定义。

TableF.1——Specificationsfordiscrete-macroparticlecounter表F.1一不连续大颗粒计数器的标准Item项目Specification标准MeasuringlimitsTheminimumdetectablesizeshouldbeintherange5to80μmandbeappropriatefortheparticlesizeunderconsiderationandtheinstrumentcapability.ThemaximumparticlenumberconcentrationoftheLSAPCshouldbeequaltoorhigherthanmaximumexpectedconcentrationfortheparticlesunderconsideration测量限度最小检出粒径应在5-80Pm,与所考量的粒径和仪器能力相当。LSAPC的最大粒子数浓度应大于或等于所考量粒子的最大预期浓度。Resolution20%forcalibrationparticlesofasizespecifiedbythemanufacturer分辨率生产商指定粒径的校正粒子数的20%Maximumpermissibleerror20%forparticlecountataspecifiedsizesetting最大允许误差指定的粒径设置下粒子计数的20%TableF.2——Specificationsfortime-of-flightparticlesizingapparatus表F。2—飞行时间粒径测定仪规格Item项目Specification规格MeasuringlimitsParticlesize0,5to20μm;Particleconcentration1,0X1θ3∕m3to1,0×108∕m3测量限度粒径0.5-20μm.粒子浓度1.0X103/立方米至1.0X108/立方米Resolutionaerodynamicdiameter:0,02μmat1,0μm;0,03μmat10μm分辨率空气动力学直径1∙0时0∙02μm,10Pm时0.03μmMaximumpermissibleerror10%offullreading最大允许误差所有读数10%Bibliography文献ISO21501-4:2007,DeterminationOfparticlesizedistribution—Singleparticlelightinteractionmethods—Part4:Ligh

温馨提示

  • 1. 本站所有资源如无特殊说明,都需要本地电脑安装OFFICE2007和PDF阅读器。图纸软件为CAD,CAXA,PROE,UG,SolidWorks等.压缩文件请下载最新的WinRAR软件解压。
  • 2. 本站的文档不包含任何第三方提供的附件图纸等,如果需要附件,请联系上传者。文件的所有权益归上传用户所有。
  • 3. 本站RAR压缩包中若带图纸,网页内容里面会有图纸预览,若没有图纸预览就没有图纸。
  • 4. 未经权益所有人同意不得将文件中的内容挪作商业或盈利用途。
  • 5. 人人文库网仅提供信息存储空间,仅对用户上传内容的表现方式做保护处理,对用户上传分享的文档内容本身不做任何修改或编辑,并不能对任何下载内容负责。
  • 6. 下载文件中如有侵权或不适当内容,请与我们联系,我们立即纠正。
  • 7. 本站不保证下载资源的准确性、安全性和完整性, 同时也不承担用户因使用这些下载资源对自己和他人造成任何形式的伤害或损失。

评论

0/150

提交评论