文档简介
目次
1总则································································································1
2术语和符号····················································································2
2.1术语····························································································2
2.2符号····························································································3
3基本规定························································································5
3.1一般规定·····················································································5
3.2作用及作用效应···········································································8
4材料及设计指标············································································9
4.1材料····························································································9
4.2设计指标····················································································11
5总体设计······················································································15
5.1一般规定···················································································15
5.2平面设计···················································································15
5.3纵断面设计················································································17
5.4线形组合设计·············································································18
5.5横断面设计················································································19
5.6其他规定···················································································21
6计算······························································································23
6.1一般规定···················································································23
6.2连接计算···················································································25
6.3疲劳计算···················································································29
6.4钢格栅计算················································································30
7构造······························································································31
7.1一般规定···················································································31
7.2钢格栅·······················································································31
7.3纵向钢梁构造要求······································································32
7.4横向联结系构造要求··································································34
7.5连接构造···················································································35
7.6排水构造···················································································37
8制作、安装及验收······································································38
8.1制作与安装················································································38
8.2验收··························································································38
9养护检修设计··············································································41
本规程用词说明················································································42
引用标准名录····················································································43
附:条文说明····················································································45
Contents
1GeneralProvisions·········································································1
2TermsandSymbols·······································································2
2.1Terms···························································································2
2.2Symbols·······················································································3
3BasicRequirements·······································································5
3.1GeneralRequirements···································································5
3.2ActionandEffectofAction··························································8
4MaterialsandDesignIndex·························································9
4.1Materials······················································································9
4.2DesignIndex··············································································11
5GeneralDesign············································································15
5.1GeneralRequirements·································································15
5.2HorizontalAlignment··································································15
5.3VertivalAlignment······································································17
5.4CombinationsofHorizontalandVerticalAlignment·····················18
5.5CrossSectionType·····································································19
5.6OtherRequirements····································································21
6Calculation····················································································23
6.1GeneralRequirements·································································23
6.2ConnectionCalculation································································25
6.3FatigueCalculation·····································································29
6.4SteelGratingCalculation····························································30
7Detailing·······················································································31
7.1GeneralRequirements·································································31
7.2SteelGrating··············································································31
7.3LongitudinalSteelBeamDetailingProvisions······························32
7.4LateralBracingSystemDetailingProvisions································34
7.5ConnectionDetailing···································································35
7.6DrainageDetailing······································································37
8Production,InstallationandAcceptance···································38
8.1ProductionandInstallation··························································38
8.2Acceptance·················································································38
9DesignforMaintenanceandOverhaul·····································41
ExplanationofWordinginthisSpecification·······························42
ListofQuotedStandard···································································43
Addition:ExplanationofProvisions··············································45
1总则
1.0.1为规范小客车专用钢格栅桥梁的设计、施工及验收,做到
安全、耐久、适用、环保、经济和美观,制定本规程。
1.0.2本规程适用于河北省城市主干道及以下道路等级的小客车
专用钢格栅桥梁。
1.0.3小客车专用钢格栅桥梁的设计、施工及验收除应执行本规
程外,尚应符合国家和行业现行有关标准的规定。
1
2术语和符号
2.1术语
2.1.1钢格栅桥梁bridgeofsteelgrating
钢格栅桥梁是指钢结构桥梁部分顶板使用钢格栅的桥梁,钢
格栅为可更换的桥面附属构件,属于行车道板的一部分。
2.1.2小客车cars
总长不大于6m、总宽不大于1.8m、总高不大于2m的小型
机动车。
2.1.3钢格栅steelgrating
钢格栅是一种由承载扁钢与横杆按照一定的间距正交组合,
通过焊接加以固定的开敞板式钢构件。
2.1.4小客车专用道路桥梁compactedcars-onlyroadandbridge
正常情况下,只允许小型客车通行的道路桥梁。
2.1.5压焊钢格栅bondingsteelgrating
在承载扁钢和横杆的每个交点处,通过压力电阻焊固定的钢
格栅,称为压焊钢格栅。其横杆通常采用扭绞方钢。
2.1.6钢格栅长度lengthofsteelgrating
平行于承载扁钢方向的钢格栅最大尺寸,称为钢格栅的长度。
2.1.7钢格栅宽度widthofsteelgrating
垂直于承载扁钢方向的钢格栅最大尺寸,称为钢格栅的宽度。
2.1.8承载扁钢bearingbar
钢格栅中承受主要荷载的扁钢。
2.1.9焊缝计算长度effectivelengthofweld
计算焊缝连接强度时采用的焊缝长度。
2.1.10钢格栅通透比permeabilityratioofsteelgrating
钢格栅上表面镂空面积与钢格栅上表面总面积之比。
2
2.1.11抗滑性skid-resistance
本规程中抗滑性采用路面抗滑性技术指标中的横向力系数
SFC60表征。
2.2符号
2.2.1材料性能
E、G——钢材弹性模量、剪切模量;
fy——钢材的屈服强度;
fd——钢材的抗拉、抗压和抗弯强度设计值;
fvd——钢材的抗剪强度设计值;
fcd——钢材的端面承压强度设计值;
a锚栓的抗拉强度设计值;
ftd——
w角焊缝的抗拉、抗剪和抗压强度设计值;
ffd——
b、b、b螺栓的抗拉、抗剪和承压强度设计值;
ftdfvdfcd——
w、w、w对接焊缝的抗拉、抗剪和抗压强度设计值。
ftdfvdfcd——
2.2.2几何参数有关符号
Wg——钢格栅路面宽度;
Wc——单个车行道宽度;
D——高强度螺栓孔径;
d——直径;
l——长度、跨径;
——厚度;
0——结构重要性系数;
3
Sd——作用组合的效应设计值;
Rd——结构或结构构件的抗力设计值;
kqf——横向抗倾覆稳定性系数;
——
Sbk,i使上部结构稳定的作用基本组合效应设计值;
——
Ssk,i使上部结构失稳的作用基本组合效应设计值;
nv——螺栓受剪面数目;
de——螺栓或锚栓在螺纹处的有效直径;
nf——传力摩擦面数目;
Pd——一个高强螺栓的预拉力;
——摩擦面的抗滑移系数;
lw——焊缝计算长度。
4
3基本规定
3.1一般规定
3.1.1桥梁设计应符合城乡规划的要求。应根据道路功能、等级、
通行能力及防洪抗灾要求,结合水文、地质、通航、环境等条件
进行综合设计。因技术经济上的原因需分期实施时,应保留远期
发展余地。
3.1.2桥梁按其多孔跨径总长或单孔跨径的长度,可分为特大桥、
大桥、中桥和小桥等四类,桥梁分类应符合表3.1.2的规定。
表3.1.2桥梁按总长或跨径分类
桥涵分类多孔跨径总长L(m)单孔跨径Lk(m)
特大桥L>1000Lk>150
大桥100≤L≤100040≤Lk≤150
中桥30<L<10020≤Lk<40
小桥8≤L≤305≤Lk<20
涵洞—Lk<5
注:1单孔跨径系指标准跨径。
2梁式桥、板式桥的多孔跨径总长为多孔标准跨径的总长;拱式桥为两端桥台内起拱
线间的距离;其他形式桥梁为桥面系车道长度。
3管涵及箱涵不论管径或跨径大小、孔数多少,均称为涵洞。
4标准跨径:梁式桥、板式桥以两桥墩中线间距离或桥墩中线与台背前缘间距为准;
拱式桥和涵洞以净跨径为准。
3.1.3跨越道路或公路的城市跨线桥梁,桥下净空应分别符合现
行行业标准《城市道路工程设计规范》CJJ37、《公路工程技术
标准》JTGB01的建筑限界规定。跨越城市轨道交通或铁路的桥
梁,桥下净空应分别符合现行国家标准《地铁设计规范》GB50157
5
和《标准轨距铁路建筑限界》GB146.2的规定。
桥梁墩位布置同时应满足桥下道路或铁路的行车视距和前方
交通信息识别的要求,并应按相关规范的规定要求,避开既有的
地下构筑物和地下管线。
3.1.4桥梁建筑应符合城乡规划的要求。桥梁建筑重点应放在总
体布置和主体结构上,结构受力应合理,总体布置应舒展、造型
美观,且应与周围环境和景观相协调。
3.1.5桥梁应根据城乡规划、城市环境、市容特点,进行绿化、
美化市容和保护环境设计。对特大型和大型桥梁、高架道路桥、
大型立交桥梁,在工程建设前期应做环境影响评价,工程设计中
应做相应的环境保护设计。
3.1.6桥梁主体结构的设计使用年限应按现行行业标准《公路工
程技术标准》JTGB01执行。钢格栅构件的设计使用年限为15年。
3.1.7桥梁应按下列极限状态进行设计:
1承载能力极限状态:对应于桥梁结构或其构件达到最大承
载能力或出现不适于继续承载的变形或变位的状态。
2正常使用极限状态:对应于桥梁结构或其结构构件达到正
常使用或耐久性的某项限值的状态。
3.1.8桥梁应根据下列设计状况进行相应的极限状态设计:
1持久状况:桥梁建成后承受结构自重、车辆荷载等持续时
间较长的状况,该状况应进行承载能力极限状态和正常使用极限
状态设计。
2短暂状况:在桥梁结构制作、运送和架设过程中承受临时
荷载的状况,该状况应进行承载能力极限状态设计,必要时进行
正常使用极限状态设计。
3地震状况:在桥梁使用过程中遭受地震时的状况,该状况
应进行承载能力极限状态设计。
4偶然状况:在桥梁使用过程中偶然出现的状况,该状况只
6
需要进行承载能力极限状态设计。
3.1.9桥梁设计安全等级的划分应符合现行行业标准《城市桥梁
设计规范》CJJ11的规定。
3.1.10在进入桥梁引道前必须按相关规定设置交通导流、限制高
度、限制速度等交通设施。且必须明确提醒驾驶员正常环境下车
辆在普通桥面或路面上行驶,雨雪及冰冻环境下在钢格栅上中低
速行驶。
3.1.11桥梁结构必须符合下列要求:
1结构在制造、运输、安装、施工和使用过程中,应满足强
度、刚度、稳定性和耐久性的相关要求。
2构件应减小由附加力、局部力和偏心力引起的应力。
3结构或者构件应根据其所处的环境条件进行耐久性设计,
采用的材料及其技术性能应符合相关标准的规定。
4选用的形式应便于制造、施工和养护。
5桥梁应进行抗震设计,抗震设计应符合国家现行标准《中
国地震动参数区划图》GB18306、《城市道路工程设计规范》GJJ
37和《公路工程技术标准》JTGB01的相关规定。对已编制地震
区划的城市,可按行政主管部门批准的地震动参数进行抗震设计。
地震作用的计算及结构的抗震设计应符合国家现行相关规范
的规定。
6当受到城市区域条件限制,需建斜桥、弯桥、坡桥时,应
根据其具体特点,作为特殊桥段进行设计。
7桥梁基础沉降量应符合现行行业标准《公路桥涵地基与基
础设计规范》JTGD63的规定。对外部为超静定体系的桥梁,应
控制引起桥梁上部结构附加内力的基础不均匀沉降量,宜在结构
设计中预留调节基础不均匀沉降的构造装置或空间。
3.1.12交通安全设施应按现行国家标准《城市道路交通设施设计
规范》GB50688执行。
7
3.2作用及作用效应
3.2.1桥梁设计采用的作用及作用效应组合应符合现行行业标准
《城市桥梁设计规范》CJJ11的规定。
3.2.2桥梁和连接件的承载能力极限状态计算应采用作用的基本
组合,连接件的正常使用极限状态计算应采用作用的标准组合。
3.2.3作用的取值除汽车作用、雪荷载外,均应符合《城市桥梁
设计规范》CJJ11的规定。
3.2.4桥梁主体结构的整体计算应采用城-B级车道荷载,桥梁主
体结构的局部加载、桥台和挡土墙压力等的计算应采用城-B级车
辆荷载。钢格栅构件计算应采用城-B级车辆荷载乘以0.5的折减
系数。城-B级车道荷载、车辆荷载的立面、平面布置及标准值应
按现行行业标准《城市桥梁设计规范》CJJ11执行。
3.2.5桥梁结构考虑温度作用时,应根据当地具体情况、结构物
试验的材料和施工条件等因素计算由温度作用引起的结构效应。
计算桥梁结构因均匀温度作用引起外加变形或约束变形时,
应从受到约束时的结构温度开始,考虑最高和最低有效温度的作
用效应,其标准值应符合现行行业标准《城市桥梁设计规范》CJJ
11的规定。
3.2.6桥梁汽车荷载冲击力的计算应按现行行业标准《城市桥梁
设计规范》CJJ11执行。
3.2.7雪荷载标准值应按现行国家标准《建筑结构荷载规范》GB
50009中的式(7.1.1)计算,其中积雪分布系数宜取r2.0,河
北省内各城市的基本雪压值应按《建筑结构荷载规范》GB50009
附录E中表E.5重现期R为50年的值采用。
雪荷载的分项系数应取1.4,组合值系数应取0.75,结构设计
使用年限调整系数应取1.0,频遇值系数宜取0.6,准永久值系数
宜取0.2。
8
4材料及设计指标
4.1材料
4.1.1应根据结构形式、受力状态、连接方法及所处环境条件,
合理地选用材料。
4.1.2钢材宜选用Q235钢、Q355钢、Q390钢和Q420钢,其质
量应分别符合现行国家标准《碳素结构钢》GB/T700和《低合金
高强度结构钢》GB/T1591的规定。其中,Q235钢中的沸腾钢不
宜用于需要验算疲劳的,以及虽不需要验算疲劳但工作温度低于
-20℃时的焊接结构;也不宜用于需要验算疲劳且工作稳定等于或
低于-20℃的非焊接结构。
4.1.3有关牌号钢材冲击韧性应符合下列规定:
1对需要验算疲劳的焊接构件,当桥梁的工作温度t处于
0℃≥t>﹣20℃范围内时,Q235和Q355的冲击韧性应满足表
4.1.3中质量等级C的要求,而Q390和Q420的冲击韧性应满足
表4.1.3中的质量等级D的要求;当桥梁工作温度t≤﹣20℃时,
Q235和Q355的冲击韧性应满足表4.1.3中质量等级D的要求,
而Q390和Q420的冲击韧性应满足质量等级E的要求。
2对需要验算疲劳的非焊接构件,当桥梁工作温度
t≤﹣20℃时,Q235和Q355的冲击韧性应满足表4.1.3中质量等
级C的要求,而Q390和Q420的冲击韧性应满足质量等级D的
要求。
表4.1.3钢材冲击韧性
钢材牌号Q235Q355Q390Q420
质量等级CDCDDEDE
9
续表4.1.3
钢材牌号Q235Q355Q390Q420
试验温度(℃)0﹣200﹣20﹣20﹣40﹣20﹣40
冲击韧性(J)2727343434273427
4.1.4当焊接结构采用Z向钢时,其材质应符合现行国家标准《厚
度方向性能钢板》GB/T5313的规定。
4.1.5钢铸件采用的铸钢材质应符合现行国家标准《一般工程用
铸造碳钢件》GB/T11352的规定。
4.1.6销、铰、轴等宜采用优质碳素结构钢锻制或轧制钢材,其
材质应符合现行国家标准《优质碳素结构钢》GB/T699的规定。
4.1.7高强度螺栓、螺母、垫圈的技术条件应符合现行国家标准
《钢结构用高强度大六角头螺栓》GB/T1228、《钢结构用高强度
大六角螺母》GB/T1229、《钢结构用高强度垫圈》GB/T1230、
《钢结构用高强度大六角头螺栓、大六角螺母、垫圈技术条件》
GB/T1231、《钢结构用扭剪型高强度螺栓连接副》GB/T3632的
规定。
4.1.8普通螺栓应符合现行国家标准《六角头螺栓C级》GB/T
5780和《六角头螺栓》GB/T5782的规定。
4.1.9焊接材料应与主体钢材相匹配,并应符合下列规定:
1手工焊接采用的焊条应符合现行国家标准《非合金钢及细
晶粒钢焊条》GB/T5117或《热强钢焊条》GB/T5118的规定。对
需要验算疲劳的构件宜采用低氢型碱性焊条。
2自动焊和半自动焊采用的焊丝和焊剂应符合现行国家标
准《熔化焊用钢丝》GB/T14957、《气体保护电弧焊用碳钢、低
合金钢焊丝》GB/T8110、《非合金钢及细晶粒钢药芯焊丝》GB/T
10045、《热强钢药芯焊丝》GB/T17493、《埋弧焊用非合金钢及
10
细晶粒钢实心焊丝、药芯焊丝和焊丝-焊剂组合分类要求》GB/T
5293或《埋弧焊用热强钢实心焊丝、药芯焊丝和焊丝-焊剂组合
分类要求》GB/T12470的规定。
4.2设计指标
4.2.1钢材的强度设计值应根据钢材的不同厚度应按表4.2.1的
规定采用。
表4.2.1钢材的强度设计值(MPa)
钢材
断面承压
抗拉、抗压和抗弯fd抗剪fvd
(刨平顶紧)fcd
牌号厚度(mm)
≤16190110
Q235钢16~40180105280
40~100170100
≤16285160
16~40275155
Q355钢40~63270150355
63~80260145
80~100250140
≤16310180
16~40295170
Q390钢370
40~63280160
63~100265150
11
续表4.2.1
钢材
断面承压
抗拉、抗压和抗弯fd抗剪fvd
(刨平顶紧)fcd
牌号厚度(mm)
≤16335195
16~40320185
Q420钢390
40~63305175
63~100290165
注:表中厚度指计算点的钢材厚度,对轴心受拉和轴心受压构件指截面中较厚板件的厚度。
4.2.2铸钢和锻钢的强度设计值应按表4.2.2的规定采用。
表4.2.2铸钢和锻钢的强度设计值(MPa)
钢号
强度种类
ZG230-450ZG270-500ZG310-57035号钢45号钢
抗拉、抗压和抗弯
170200225250280
fd
抗剪fvd100115130145160
铰轴紧密接触时径
85100110125140
向受压frdl
辊轴或摇轴自由接
6.58.09.010.011.0
触时径向受压frd2
销孔承压fsd———190210
注:1铰轴紧密接触系指接触面为圆弧中心角为2×45°的接触;辊轴或摇轴自由接触系指
轴与板平面的接触。
2计算紧密接触或自由接触受压强度时,其承压面积采用轴径截面。轴与板采用不同
钢种时,径向受压设计值采用其较低者。
12
4.2.3焊缝的强度设计值应按表4.2.3的规定采用。
表4.2.3焊缝的强度设计值(MPa)
构件钢材对接焊缝角焊缝
抗拉w
焊接方法和焊f
抗压td抗剪抗拉、抗压或
条型号厚度
牌号w焊缝质量等级w抗剪w
(mm)
fcdfvdffd
一、二级三级
自动焊、半自
动焊和E43型Q235钢≤16190190160110140
焊条的手工焊
≤16285285240165
16~40275275235160
自动焊、半自
动焊和E50型Q355钢40~63270270230155175
焊条的手工焊
63~80260260220150
80~100250250210145
≤16310310265180
16~40295295250170
Q390钢200
40~63280280240160
自动焊、半自63~100265265225150
动焊和E55型
焊条的手工焊≤16335335285195
16~40320320270185
Q420钢200
40~63305305260175
63~100290290245165
w
注:1对接焊缝受弯时,在受压区的抗弯强度设计值取fcd,在受拉区的抗弯强度设计值取
w
ftd。
2焊缝质量等级应符合现行国家标准《钢结构工程施工质量验收规范》GB50205的规
定。其中厚度小于8mm钢材的对接焊缝,不应采用超声波探伤确定焊缝质量等级。
13
4.2.4高强度螺栓预应力设计值Pd应按表4.2.4的规定取用。
表4.2.4高强度螺栓的预拉力设计值Pd(kN)
螺纹规格
性能等级
M20M20M24M27M30
8.8S125150175230280
10.9S155190225290355
4.2.5钢材和铸钢的物理性能指标应按表4.2.5的规定采用。
表4.2.5钢材和铸钢的物理性能指标
弹性模量剪切模量线膨胀系数α密度ρ
EG泊松比ν
(MPa)(MPa)(1/oC)(kg/m3)
2.06×1050.790×10512×10-60.317850
4.2.6普通螺栓和锚栓连接的强度设计值应符合现行《公路钢结
构桥梁设计规范》JTGD64的规定。
14
5总体设计
5.1一般规定
5.1.1平面和纵断面设计应符合城市路网规划、道路红线、道路
功能,并应综合考虑土地利用、文物保护、环境景观、征地拆迁
等因素。
5.1.2平面和纵断面应与地形地物、地质水文、地域气候、地下
管线、排水等要求结合,并应符合各级道路的技术指标,应与周
围环境相协调,线形应连续与均衡。
5.1.3城市主干路应做好路线的线形组合设计,各技术指标应恰
当、平面顺适、断面均衡、横断面合理;各结构物的选型与布置
应合理、实用、经济。
5.2平面设计
5.2.1道路平面线形由直线、平曲线组成,平曲线由圆曲线、缓
和曲线组成,应处理好直线与平曲线的衔接,合理地设置缓和曲
线、超高、加宽等。
5.2.2道路圆曲线最小半径应符合表5.2.2的规定。一般情况下应
采用大于或等于不设超高最小半径值;当地形条件受限制时,可
采用设超高最小半径的一般值;当地形条件特别困难时,可采用
设超高最小半径的极限值。
5.2.3当圆曲线半径小于表5.2.2中不设超高最小半径时,在圆曲
线范围内应设超高。最大超高横坡度应符合表5.2.3的规定。当由
直线段的正常路拱断面过渡到圆曲线上的超高断面时,必须设置
超高缓和段。
15
表5.2.2圆曲线最小半径
设计速度(km/h)6050403020
不设超高最小半径(m)60040030015070
一般值3002001508540
设超高最小半径(m)
极限值150100704020
注:“一般值”为正常情况下的采用值;“极限值”为条件受限时,可采用的值。
表5.2.3最大超高横坡度
设计速度(km/h)60,5040,30,20
最大超高横坡(%)42
5.2.4当圆曲线半径小于或等于250m时,应在圆曲线内侧加宽,
并应设置加宽缓和段。
5.2.5视距应符合下列规定:
1停车视距应大于或等于表5.2.5规定值,积雪或冰冻地区
的停车视距宜适当增长。
2当车行道上对向行驶的车辆有会车可能时,应采用会车视
距,其值应为表5.2.5中停车视距的两倍。
3对设置平、纵曲线可能影响行车视距路段,应进行视距验
算。
表5.2.5停车视距
设计速度(km/h)6050403020
停车视距(m)7060403020
16
5.3纵断面设计
5.3.1小客车专用钢格栅桥梁机动车道最大坡度应符合表5.3.1
的规定,并应符合下列规定:
表5.3.1最大纵坡
设计速度(km/h)6050403020
一般值56789
最大纵坡
(%)
极限值7891012
1新建道路应采用小于或等于最大纵坡一般值;改建路桥、
受地形条件或其他特殊情况限制时,经技术经济论证后,可采用
最大纵坡极限值。
2钢格栅路面SFC60值应根据不同纵坡进行选取,SFC60取
值区间宜为64~74,纵坡大时取大值。
5.3.2纵坡的最小坡长应符合表5.3.2规定。
表5.3.2最小坡长
设计速度(km/h)6050403020
最小坡长(m)1501301108560
5.3.3道路不同纵坡的最大坡长应符合表5.3.3规定。道路连续上
坡或下坡时,应在不大于表5.3.3所规定的纵坡长度范围内设置缓
和坡段,其长度应符合表5.3.2最小坡长的规定。
5.3.4各级道路纵坡变化处应设置竖曲线,竖曲线宜采用圆曲线,
竖曲线最小半径与竖曲线最小长度应符合表5.3.4规定。一般情况
下应大于或等于一般值;特别困难时可采用极限值。
17
表5.3.3不同纵坡最大坡长(m)
设计速度(km/h)6050403020
6400350———
7300250250400500
—
纵8150200300400
坡
坡9——150200300
度
(%)
10———150200
11————150
12————100
表5.3.4竖曲线最小半径与竖曲线最小长度
设计速度(km/h)6050403020
一般值18001350600400150
凸形竖曲线
(m)
极限值1200900400250100
一般值15001050700400150
凹形竖曲线
(m)
极限值1000700450250100
一般值120100906050
竖曲线长度
(m)
极限值5040352520
5.4线形组合设计
5.4.1线形组合应满足行车安全、舒适以及与沿线环境、景观协
18
调的要求,平面、纵断面线形应均衡,路面排水应通畅。
5.4.2线形组合设计应符合下列规定:
1应使线形在视觉上能自然地诱导驾驶员的视线,并应保持
视觉的连续性。
2应避免平面、纵断面、横断面极限值的相互组合设计。
3平、纵面线形应相互对应,技术指标大小均衡连续,以及
与之相邻路段各技术指标的均衡、连续。
4条件受限时选用平面、纵断面的各接近或最大、最小值及
其组合时,应考虑前后地形、技术指标运用等对实际运行速度的
影响。
5横坡与纵坡应组合得当,并应利于路面排水和行车安全。
5.5横断面设计
5.5.1桥梁及引道横断面布置形式应采用单幅路、两幅路布置形
式,具体形式选取应符合现行行业标准《城市道路工程设计规范》
CJJ37的规定。
1单幅路如图5.5.1-1。横断面总宽由道路宽度WPc、防撞护
栏宽度Eb组成。
图5.5.1-1单幅路断面布置形式示意图
2两幅路如图5.5.1-2。横断面总宽由道路宽度WPc、防撞护
栏宽度Eb、中间分隔带宽度Wdm组成。中间分隔带应设置分隔设
施。
19
图5.5.1-2两幅路断面布置形式示意图
3单个车行道布置形式如图5.5.1-3。单个车行道宽度Wc由
普通路面宽度W1、W2,钢格栅路面宽度Wg组成。且最小宽度应
符合表5.5.1。
表5.5.1单个车行道各分部最小宽度
普通路面宽度W1、W2(m)0.9
钢格栅路面宽度Wg(m)0.7
图5.5.1-3单车道布置形式示意图
5.5.2单个车行道宽度不应小于3.25m。
5.5.3桥梁结构宜采用工字型钢板梁加钢格栅或箱型钢板梁加钢
格栅的结构形式,钢格栅桥梁横断面宜采用图5.5.3布置形式。
20
(a)工字型钢板梁示意图
(b)箱型钢板梁示意图
图5.5.3单车道桥面布置示意图
5.6其他规定
5.6.1桥梁的桥面净空限界、桥面最小净高、机动车车行道宽度、
安全带宽度、分隔带宽度应符合现行行业标准《城市道路工程设
计规范》CJJ37的规定。
21
5.6.2桥梁引道的布设应按现行行业标准《城市道路工程设计规
范》CJJ37执行;引桥应按本规程的有关要求布设。
5.6.3纵坡大于5.0%的引道应按5.5节横断面布置钢格栅,钢格
栅下方需设排水暗沟,连接附近市政排水系统。
22
6计算
6.1一般规定
6.1.1构件应按承载能力极限状态验算强度和稳定性,作用组合
效应设计值按现行行业标准《城市桥梁设计规范》CJJ11计算。
疲劳计算应按本章6.3节的有关规定执行。
进行承载力极限状态设计时,结构重要性系数应符合现
6.1.20
行行业标准《城市桥梁设计规范》CJJ11的相关规定。
6.1.3结构分析采用的模型和基本假定,应能反映结构实际受力
状态,其精度应能满足结构设计要求。在结构分析中应考虑环境
对构件和结构性能的影响。
6.1.4结构受力分析可按线弹性理论进行,当极限状态条件下结
构的变形不能被忽略时,应考虑几何非线性对结构受力的影响。
6.1.5结构动力分析应考虑下列因素:
1所有相关的结构构件质量、刚度和阻尼特性。
2模型的边界条件应反映结构的固有特性。
6.1.6结构强度、稳定与变形计算
1桥梁承载能力极限状态应按下式要求进行验算:
≤
0SdRd(6.1.6-1)
式中:0——结构重要性系数;
Sd——作用组合的效应(如轴力、弯矩或表示几个轴力、
弯矩的向量)设计值;
Rd——结构或结构构件的抗力设计值。
2上部结构采用整体式截面的梁桥在持久状况下结构体系
不应发生改变,并应按下列规定验算横桥向抗倾覆性能:
温馨提示
- 1. 本站所有资源如无特殊说明,都需要本地电脑安装OFFICE2007和PDF阅读器。图纸软件为CAD,CAXA,PROE,UG,SolidWorks等.压缩文件请下载最新的WinRAR软件解压。
- 2. 本站的文档不包含任何第三方提供的附件图纸等,如果需要附件,请联系上传者。文件的所有权益归上传用户所有。
- 3. 本站RAR压缩包中若带图纸,网页内容里面会有图纸预览,若没有图纸预览就没有图纸。
- 4. 未经权益所有人同意不得将文件中的内容挪作商业或盈利用途。
- 5. 人人文库网仅提供信息存储空间,仅对用户上传内容的表现方式做保护处理,对用户上传分享的文档内容本身不做任何修改或编辑,并不能对任何下载内容负责。
- 6. 下载文件中如有侵权或不适当内容,请与我们联系,我们立即纠正。
- 7. 本站不保证下载资源的准确性、安全性和完整性, 同时也不承担用户因使用这些下载资源对自己和他人造成任何形式的伤害或损失。
最新文档
- 财务规划税务策略绩效评估表
- 环保企业技术部工程师技术成果应用评估表
- 设计行业设计创意效果绩效衡量表
- 智能家电产品研发岗位绩效评价表
- 销售团队业绩奖金发放通知函(5篇)
- 财务结算异常及处理措施通知7篇
- 桥梁结构加固设计与实施手册
- 安全检查整改事项确认函(6篇)
- 农业科技公司技术支持工程师绩效分析表
- 小学道法教资面试法律试卷2026下半年
- T∕CSICE 061-2026 混合动力总成耐久性试验方法
- 初中物理八年级下册《摩擦力》教学设计
- 数学五上综合实践《小小设计师》大单元教学设计(北师大2027新教材)
- 2026年湖南中考语文试卷及答案解析
- (2026年版)中国有肾脏意义的单克隆免疫球蛋白血症诊治专家共识课件
- 家用电器产品检测合同协议
- SYT 6649-2025《油气管道管体缺陷修复技术规范》
- 2026年高考历史总复习(全国):专题训练01中国古代史部分(选择题必练100题)(原卷版)
- 2025年吉林省地理生物会考真题试卷+解析及答案
- 2026年九省联考化学答案及试卷
- 母婴护理培训课件:宝宝洗澡与抚触技巧
评论
0/150
提交评论