版权说明:本文档由用户提供并上传,收益归属内容提供方,若内容存在侵权,请进行举报或认领
文档简介
CATLWORKINGMANUAL工作手册FormNo.:QF-T-WM-AAuthor/Dept.:ShiPingFeng/MDEDocument#:WM-S8-011Rev:1.0Title:TheStandardOfAutomationEquipmentTechnology自动化通用技术规范1INDEX目录1INDEX目录2PURPOSE目的3SCOPE适用范围4DEFINITIONSANDABBREVIATIONS定义与缩写5REFERENCEDOCUMENTS参考文件6RESPONSIBILITY职责7DESCRIPTION细则/描述8RECORDSHEET记录表单9REVISIONRECORD修改记录10APPENDIX附件2PURPOSE目的StandardizetheelectricalcontrolcontentofCATLautomationequipmentinthestagesofbidding,design,procurement,manufacturing,installation,commissioning,acceptance,etc.,inordertofacilitatethemaintenanceandmanagementofsubsequentproductionlineequipment;规范CATL自动化设备在招投标、设计、采购、制造、安装、调试、验收等阶段所涉及的电气控制内容,以利于后续产线设备的维护与管理。3SCOPE适用范围ThisspecificationisapplicabletothenecessarylinksthatNingdeTimesTechnologyCo.,Ltd.anditssubsidiaries,holdingcompaniesandequipmentmanufacturersshouldfollowduringthemanufacturing,installation,commissioninganddeliveryofautomationequipment.本规范适用于宁德时代科技股份有限公司及其下属分公司、控股公司、设备制造商在自动化设备制造、安装、调试及交付等阶段应遵守的必要环节。4DEFINITIONSANDABBREVIATIONS定义与缩写4.1Definitions定义4.1.1TotalRequirementsser总体要求Theautomationcontrolrelatedequipmentinvolvedinthedesign,manufacture,installation,commissioninganddeliveryoftheproductionlineautomationequipmentisdescribed.针对产线自动化设备在设计、制造、安装、调试、交付时所涉及的自动化控制相关事宜进行表述。4.1.2TechnicalSpecificationForPowerSupply电源技术规范Thepowersupply,fieldcontrolcabinetpowersupply,powersupplyclassificationanduninterruptiblepowersupplyinvolvedintheproductionlineequipmentareclearlydefined.针对产线设备涉及的动力电源、现场控制柜电源、电源分级以及不间断电源做了明确规定。4.1.3ElectricEnergyMeasurement电能测量Theenergymeasurementandenergymonitoringinvolvedinthepowersupplycabinetoftheproductionlineequipmenthavebeenclearlydefined,andtherequirementsfortheselectionofthemeasuringcomponentsandthecircuitdesignhavebeenmade.针对产线设备动力电源柜所涉及的能源测量,能源监控等做了明确规定,分别从测量元件的选型及回路设计方面做了要求。4.1.4Control柜网Requirements控制柜要求Thedesignandproductionofthecontrolcabinetareclearlydefinedintermsofcontrolcabinetcomponentselection,controlcabinetcomponentlayout,cablelayingandsafetycontrolloopdesign.从控制柜元器件选型,控制柜元器件布局、线缆敷设以及安全控制回路设计等方面对控制柜的设计与制作做了明确规定。4.1.5FieldWirring现场布线要求Forthepowercable,controlcable,fiberlayingandsensorcableconnectionofthevariouscomponentsofthefielddevice,theconnectionbetweenthecablesisclearlydefined.针对现场设备各部件的动力电缆、控制线缆、光纤的敷设及传感器线缆连接、线缆间的接驳做了明确规定。4.1.6Bridge,Trunking,AndConduitInstallationPrinciples桥架、线槽、线管与接地规范Theproduction,installationandgroundingspecificationsoftheon-sitebridge,trunkingandconduitareclearlydefined.针对现场桥架、线槽、线管的制作、安装以及接地规范做了明确规定。4.1.7TechnicalRequirementsOfPLCPLC技术要求ClearlydefinedfromCPUselection,PLCpowersupply,IOmoduleconfiguration,communicationmethod,andprogrammingsoftware.从CPU选型、PLC电源、IO模块配置、通讯方式以及编程软件等方面做了明确规定。4.1.8OperationPanel操作面板Clearrequirementsaremadeforthecontrolelements,display原inals,andthefunctionsandlayoutofthe原inalsinvolvedintheon-siteoperationpanel.针对现场操作面板上所涉及到的控制元件、显示元件以及元件的功能和布局等做了明确要求。4.1.9ElectricalControlStrategiesAndRequirements电气控制策略及要求Theelectricalcontroloftheequipmentisclearlydefinedfromthedesignofthemaincontrolloopandthesafetyoftheloopcontrol.从主控回路设计以及回路控制安全对设备电气控制做了明确规定。4.1.10OperationPanel驱动技术Forthedrivecomponentscommonlyusedinthefield,clearregulationshavebeenmadeintermsofselection,controlmethods,installationandprotection.针对现场常用的驱动部件,从选型、控制方式、安装及防护等方面做了明确规定。4.1.11EquipmentAutomationControlSystemFramework设备自动化控制系统框架范Standardizethenetworkequipmentarchitectureofthefieldequipment,andclearlydefinethehardwareconfiguration,softwarerequirementsandcontrolmethodsoftheexecutionlayer,controllayer,hostcomputer,MES,etc.规范现场设备网络架构方式,明确规定执行层、控制层、上位机、MES等的硬件配置、软件要求以及控制方式。4.1.12HeatingSystemSpecification加热系统规范Theregulationsclearlydefinethesafetycontroloftheheatingsystem.规对加热系统的安全控制做了明确规定。4.1.13TheRobot机器人Clearregulationshavebeenmadeforrobotselection,robotsafetycontrol,androbotpipelineprotection.对机器人选型、机器人安全控制及机器人管线保护等做了明确规定。4.1.14Document,DrawingPreparation文档、图纸编制Thedesignoftheelectricalschematicisstandardized.对电气原理图的设计进行了规范。4.1.15Identification标识Thecomponentidentification,controlcabinetnameplate,buttonidentification,andcableidentificationspecificationsaredescribed.表述了元器件标识、控制柜铭牌、按钮标识、线缆标识规范。4.1.16LightingAndSocketControlProtectionCircuit照明和插座Thecontrolcabinetlightingandsocketsandtheircontrolareclearlydefined.对控制柜照明和插座及其控制进行了明确规定。4.1.17LaserSystem激光系统Thecontrol,installationandprotectionofthelasersystemareclearlystated.对激光系统的控制、安装以及防护做了明确说明。4.2Abbreviations缩写NA无5REFERENCEDOCUMENTS参考文件Anyreferencedocumentbelowwhichdoesnothaveaversionnumber,itslatesteditionshouldbeappliedtothisprocedure.凡是未注版本的参考文件,其最新版本适用于本程序。Note:Thereferencedocumentsshouldbesortedaccordingtothedocumenttype,followedbypropersequenceasinternationalstandards,regionalstandards,nationalstandards,nationalstandards,communitystandards,localstandards,corporatestandards,corporatedocuments,whichthesamecategoryofdocumentsshouldbefirstalphabetical,andthennumericalrankingfromsmalltolarge.参考文件应按文件类别进行排序,依次为国际标准、区域标准、国家标准、行业标准、团体标准、地方标准、企业标准、公司文件,其中同一类别文件应先按字母,再按数字从小到大依次排序。ReferenceDoc.Number参考文件号Doc.Source文件来源Title标题GB4208-2017NationalStandard国家标准ShellProtectionRating(IPCode)外壳防护等级(IP代码)GB3956-2008NationalStandard国家标准CableConductor电缆的导体GB2682-81NationalStandard国家标准TheColorOfTheLightsAndButtonsInTheElectrician'sCompleteSet电工成套装置中的指示灯和按钮的颜色1EC61131InternationalStandard国际标准ProgrammableLogicControllerStandard可编程逻辑控制器标准1EC61508-2010InternationalStandard国际标准FunctionalSafetyOfElectrical/Electronic/ProgrammableElectronicSafety-RelatedSystems电气/电子/可编程电子安全系统的功能安全1EC61511InternationalStandard国际标准FunctionalSafetyOfProcessIndustrialSafetyInstrumentationSystems过程工业安全仪表系统的功能安全1EC61000InternationalStandard国际标准ElectrostaticStandard静电标准1EC60529:2013InternationalStandard国际标准ShellProtectionRating(IPCode)外壳防护等级(IP代码)1EC801-5InternationalStandard国际标准InternationalElectromagneticCompatibilityTestStandard国际电磁兼容性测试标准1EC81346InternationalStandard国际标准IndustrialSystems,PlantsAndEquipment,AndIndustrialProducts-StructuralPrinciplesAndReferenceNaming工业系统、装置和设备以及工业产品--结构化原则和参考命名6RESPONSIBILITY职责6.1MDE设备开发部Responsiblefortheintroductionofthisspecificationasaguidancedocumentforequipmentdevelopmentduringtheissuancephaseofequipmentdevelopmenttechnicalspecifications,andrequiresequipmentsupplierstoalwaysfollowthisspecificationatallstagesofdesign,manufacturing,installationandcommissioning,acceptanceanddelivery.负责在设备开发技术规格书发行阶段,导入本规范作为设备Page4of81 DOC.NO.:WM-S8-011-1.0开发的指导文件,并要求设备供应商在设计、制造、安装调试、验收交付各阶段始终以本规范为指导。6.2ME制造工程部Duringtheentirelifecycleoftheequipment,withtheguidanceofthisspecification,implementequipmentacceptanceandupgradeofsubsequentequipment,andmakereasonablesuggestionsfortheproductionandupdateofthisspecification.在设备的整个生命周期中,以本规范为指导,落实设备验收和后续设备的升级改造,同时对本规范的制作与更新提出合理建议。7DESCRIPTION细则/描述7.1TotalRequirements总体要求7.1.1DetailedSpecificationOfTheAutomationEquipmentControl柜柜AndItsSurroundingwiring.对自动化设备控制柜及其周边的布线做了详细规范。7.1.2ClearlyDefinedTheInternalComponentsSelection,LayoutAndIOTransferMethodOfTheControl柜柜。针对控制柜内部元器件选型、布局以及IO转接方式做了明确规定。7.1.3DetailedSpecificationOfTheLayingOfFieldCables,ConduitsAndOpticalFibers对现场电缆、导管以及光纤的敷设做了详细规范。7.1.4TheDesignOfPLCAnddistributedSitesHasbeenClearlyDefined,AndTheCommunicationMethodsBetweenFieldDevicesHaveAlsobeenStandardized.PLC及分布式站点的设计做了明确规定,同时也规范了现场设备间的通讯方式。7.1.5DetailedSpecificationForTheDesignOfTheOperationPanelOfTheAutomationEquipment.针对自动化设备操作面板的设计做了详细规范。7.1.6TheDesignAndControlStrategyOfTheSafetyLoopOfTheAutomationEquipmentIsClearlyDefined.对自动化设备安全回路的设计及控制策略做了明确的规定。7.1.7ClearRegulationsForRobotAndRobotSafetyControl.对机器人及机器人安全控制做了明确规定。7.1.8DetailedSpecificationOfTheDesignOfTheElectricalSchematicAndTheIdentificationOfTheComponents.对电气原理图的设计以及元器件的标识做了详细规范。7.1.9DetailedRequirementsForLaser,GlueAndHeatingSystems针对激光、涂胶以及加热系统也做了详细要求7.2TechnicalSpecificationForPowerSupply电源技术规范7.2.1PowerRequirements电源要求a)BasicPrinciplesofTotalPowerSupply总电源基本原则Totalpowersupplyvoltagespecification,3Ph+N+PEthree-phasefive-wiresystem,AC380V±10%,50Hz,powerdistributioncabinetmainswitchwithpowersupplyphaseloss,neutrallinedisconnection,lowvoltage,shortcircuit,overcurrentandoverloadprotection.Aftertheequipmentsystemisinstalled,thesingle-phasedistributionswitchwiringmethodmustconsiderthecurrentthree-phasebalanceproblem.Thepowersupplyterminaloftheequipmentcabinet(includingnotlimitedtothepowerdistributioncabinet)mustbefastenedbythelinePINhead+fixingbolt,butnotothermethods(suchasquick-connectterminalblock),thepowerlineinletshouldbeFilledwithfireproofmudtoensureagoodsealofthecontrolcabinet.总电源电压规格,3Ph+N+PE三相五线制,交流380V±10%,50Hz,配电柜总开关设有电源缺相、中性线断线、低电压、短路、过流和过载保护。设备系统安装后,单相配电开关接线方式必须考虑电流三相平衡问题。设备电柜供电接线端(包括并不局限于化成配电柜),必须使用线PIN头+固定螺栓压紧的方式,而不能采用其它方式(如快插端子排),电源线进线口应采用防火泥填充,以确保控制柜有良好的密封性。Table1Voltagerequirements电压要求Standardvoltage[V]标准电压[V]Allowablevoltagefluctuationrange(±10%)允许电压波动范围(±10%)Maximumvoltage[V]最高电压值[V]Minimumvoltage[V]最低电压值[V]380418342220242198b)DesignPrincipleofMainPowerCircuit主电源回路设计原则Allequipmentshouldbeequippedwithindependentcontrolcabinets.Themaincontrolcabinetsshouldnotbeplacedinthemachineorundertheequipment.Onlythetransferboxorsub-stationcanbeplacedinthemachine.Thepositionofthetransferboxandsub-stationshouldbeconvenientformaintenance.Thepowersupplyinthecabinetshouldbesetproperly.Thepowerprotectionmeasuresandpowersupplystabilitymeasures,thepowermainswitchshouldhavethefunctionofhangingthesafetylock,thepowerprotectionlevelisdividedintofourormorelevels,toensurethatthepowercanbequicklycutoffunderabnormalconditions,andthepowercircuitdoesnotaffecteachother.Avoltageregulator(regulator)isrequiredforthecircuitwithhighvoltageregulationrequirements.Allsupplierpowersupplycircuitdesignsshouldfollowthefollowingprinciples(Figure1).所有设备应配备独立控制柜,主控电柜不可放置在机台内或设备下方,机台内只能放置中转盒或子站,中转盒和子站的位置要方便维修,柜内电源应设置合理的电源保护措施及电源稳定措施,电源总开关应具备悬挂安全锁的功能,电源保护等级分四级以上,确保异常情况下能快速切断该路电源,电源回路之间互不影响。针对稳压要求较高的回路需要加装稳压装置(稳压变压器)。所有供应商电源回路设计应遵循如下原则(图1)。总电源开关三极断路器三极断路器伺服驱动三极断路器三极断路器变频驱动三极断路器三极断路器三相异步电机三极断路器三极断路器机器人三极断路器三极断路器加热系统三极断路器三极断路器其他三相负载极断路器稳压变压器极断路器PLC电源极断路器上位机电源极断路器CCD电源带漏保断路器编程插座极断路器极断路器电柜照明极断路器设备照明极断路器开关电源极断路器主控回路供电一极断路器HMI/PLC供电一极断路器传感器供电极断路器开关电源一极断路器伺服电机一极断路器机器人控制器极断路器开关电源一极断路器电磁阀极断路器开关电源一极断路器PLC输入电源一极断路器PLC输出电源极断路器开关电源一极断路器其他24V电源PLC输入电源输入分支电源1带灯保险盒执行机构1输入分支电源2带灯保险盒执行机构2涉前当さ游建造潮PLC输出电源输出分支电源1带灯保险盒执行机构1输出分支电源2带灯保险盒执行机构2第一级保护第级保护第三级保护第四级保护Fig.1DesignPrinciplesofPowerCircuit图1电源回路设计原则c)Phasesequenceprotection相序保护Forthecontrolsystemwithpowerphasesequencerequirements,thephasesequenceprotectionrelaymustbeusedinthecontrolcircuittoprotectthephasesequenceoftheentirelooppowersupplytoensurethesafetyandreliabilityofthewholesystem.针对有电源相序要求的控制系统,控制电路中必须使用相序保护继电器对整个回路电源相位顺序进行保护,以确保整个系统安全可靠。PhasesequenceprotectionrelaysuseSchneiderbrandRM22TG20products,asshowninFigure2:相序保护继电器选用Schneider品牌RM22TG20产品,如图2所示:总电源开关三极断路器三极断路器伺服驱动三极断路器三极断路器变频驱动三极断路器三极断路器三相异步电机三极断路器三极断路器机器人三极断路器三极断路器加热系统三极断路器三极断路器其他三相负载极断路器稳压变压器极断路器PLC电源极断路器上位机电源极断路器CCD电源带漏保断路器编程插座极断路器极断路器电柜照明极断路器设备照明极断路器开关电源极断路器主控回路供电一极断路器HMI/PLC供电一极断路器传感器供电极断路器开关电源一极断路器伺服电机一极断路器机器人控制器极断路器开关电源一极断路器电磁阀极断路器开关电源一极断路器PLC输入电源一极断路器PLC输出电源极断路器开关电源一极断路器其他24V电源PLC输入电源输入分支电源1带灯保险盒执行机构1输入分支电源2带灯保险盒执行机构2涉前当さ游建造潮PLC输出电源输出分支电源1带灯保险盒执行机构1输出分支电源2带灯保险盒执行机构2第一级保护第级保护第三级保护第四级保护Fig.1DesignPrinciplesofPowerCircuit图1电源回路设计原则c)Phasesequenceprotection相序保护Forthecontrolsystemwithpowerphasesequencerequirements,thephasesequenceprotectionrelaymustbeusedinthecontrolcircuittoprotectthephasesequenceoftheentirelooppowersupplytoensurethesafetyandreliabilityofthewholesystem.针对有电源相序要求的控制系统,控制电路中必须使用相序保护继电器对整个回路电源相位顺序进行保护,以确保整个系统安全可靠。PhasesequenceprotectionrelaysuseSchneiderbrandRM22TG20products,asshowninFigure2:相序保护继电器选用Schneider品牌RM22TG20产品,如图2所示:d)Controlpowersupply控制电源1)ThecontrollooppowersupplyisspecifiedasDC24Vinprinciple.Ifothervoltagesareusedascontrolpowerinspecialcases,theymustbeconfirmedandapprovedbytheCATLengineer.控制回路电源原则上规定为直流24V。若特殊情况采用其他电压作为控制电源,须与CATL工程师确认并得到批准。2)Thepowersupplyshouldbeconfiguredbasedon1.5timesthetotalpowerconsumptionofthecontrolsystematfullload.应根据控制系统满负载时总功耗的1.5倍来配置电源。3)Thepowercircuitshouldhaveafilteringfunctiontoensurevoltagestability.电源回路应有滤波功能,以确保电压的稳定性。4)Systempowerandloadpowershouldbestrictlyseparated.系统电源和负载电源应严格分开。5)Eachcontrolloopneedstobesetwithindependentbreakcontrolfunction,andtheloopsdonotaffecteachother.每个控制回路须设置独立的分断控制功能,且回路之间互不影响。6)Forequipmentwithhigh-precisionmeasurementanddetectionsystems(suchasCCD),alinearpowersupplyshouldbeprovided.针对有高精度测量与检测系统的设备(如CCD),应配备线性电源。7)TheDC24VpowersupplyineachbranchcontrolboxinsidethedeviceincreasestheLEDfuseterminalblock.设备内部的各分支控制盒内的DC24V电源增加LED保险端子排。7.2.2UPSPowerSupplyUPS电源a)UPSpowersupplyselectionUPS电源选择TheareawheretheproductionlineequipmenthasindustrialPCshouldbeequippedwithUPSpowersupply,andtheonlineUPSpowersupplyshouldbeused.ThebacktimeoftheUPSpowersupplyshouldbenolessthan0.5hours.ItisrecommendedtouseSchneider,SmartUPS1000UXpowersupply.IfotherUPSpowersupplyisused,itneedstoberecognizedbyCATLengineers.产线设备有工业PC的区域应配备UPS电源,应选用在线式UPS电源。UPS电源后背时间应不小于0.5小时,推荐使用施耐德,SmartUPS1000UX电源,若采用其他UPS电源,需得到CATL工程师认同。b)UPSperformanceindicatorrequirementsUPS性能指标要求1)UPSpowersupplysystemrequirements:single-phaseAC220Vinput,single-phaseAC220Voutputmode,theselectionpowerisusuallynotlessthantwicethefullloadofworkingconditions.选用单相交流220V输入,单相交流220V输出方式,选型功率通常不小于工况满载时的两倍2)Operatingenvironmentrequirements:UPSpowersupplyunderpowerfrequencyisusedasbackuppowersupplyforuppercomputerofproductionlineequipment.运行环境要求:使用工频下的UPS电源作为产线设备上位机的后备电源3)UPSmusthavereliablevoltagestabilizationfunction.UPS须具备可靠的稳压功能7.3ElectricEnergyMeasurement电能测量7.3.1InstrumentSelectionSpecification仪表选型规范a)SelectionofElectricEnergyMeter电能表选型1)Theelectricenergymetercanbeinstalledontheelectriccabinetdoorasneeded,oritcanbeinstalledontheinnersideoftheelectriccabinet(railtypeinstallation).电能表可根据需要选择安装在电柜门上,也可以选择安装在电柜内侧安装板上(导轨式安装)。2)TheSchneiderandSiemensbrandsshouldbechosen.Ifyouneedtochooseanotherbrand,youneedCALTengineerstoagree.应选择Schneider和Siemens品牌,若需要选择其他品牌,需要CATL工程师认同。b)OtherAttachments其他附件Inprinciple,thecurrenttransformerrecommendedbytheenergymetershouldbeselected,andthelayoutandconnectionshouldbestrictlyinaccordancewiththeinstallationrequirementsofthecomponents.原则上应选择电能表推荐使用的电流互感器,且应严格按照元器件的安装要求进行布局与连接。7.4ControlCabinetRequirements控制柜要求7.4.1CabinetComponentArrangement柜体元器件布置a)Principle原则Allcomponentsshallbeinstalledinaccordancewiththemanufacturer'sclearlymarkedinstallationspecifications.所有元器件的安装应满足制造商明确标示的安装规范。b)Layoutrequirements布局要求1)Thecomponentsarepreferablyinstalledinarail-mountedmanner,andrivetsarenotallowedtobeinstalled.元器件优先选用导轨式安装方式安装,禁止使用铆钉安装。2)Aluminumalloyorgalvanizedmaterialisselectedforcomponentsinstallationguide,andprotectiveterminalsarerequiredatbothendsoftheguide.元器件安装导轨材质选用铝合金或镀锌材质,导轨两端需加装防护端盖。3)TheACandDCtransformersshouldbeinstalledawayfromcomponentssensitivetoelectromagneticfieldssuchasPLCsandinverters.Thedistancebetweentheleftandrightoftheelectricalcomponentsorslotsshouldbe≥50mm,andthedistancebetweentheupperandlowerslotsshouldbe≥35mm.交、直流变压器安装应远离PLC、变频器等对电磁场敏感的元件放置,与电气元件或线槽的左右的间距≥50mm,与线槽的上下间距≥35mm。4)Electricalcomponentsshouldallbeinstalledontheelectricalcabinetofthecontrolcabinetandshouldbeinstalledonthefront.电气元件应全部安装在控制柜电气安装板上,且应正面安装。5)Strongandweakelectricalterminalsshouldbearrangedseparately,withobviousidentificationandserialnumber,andtheterminalblockshouldbeeasytoconnectandreplace.强弱电端子应分开布置,并有明显标识和序号,端子排应便于接线和更换。6)Electricalapplianceswithanti-shockrequirementsshouldbeequippedwithdampingdevices,andthefasteningboltsshouldbeloosened.有防震要求的电器应增加减震装置,其紧固螺栓应采取防松措施。7)Theinstallationpositionofelectricalcomponentsthatrequirefrequentmaintenance,overhaul,andadjustmentshouldnotbetoohighortoolow.Theinstallationpositionoftheoperationswitchandtheinstrumenttobemonitoredfrequentlyshouldconformtotheergonomicprinciple.需要经常维护、检修、调整的电器元件安装位置不宜过高或过低,操作开关及需经常监视的仪表的安装位置应符合人体工程学原理。8)Theclearanceandcreepagedistanceofvariouselectricalcomponentsanddevicesshallcomplywiththecomponentinstallationrequirements.各种电气元件和装置的电气间隙、爬电距离应符合元器件安装要求。9)Transformers,servodrives,inverters,etc.shouldbeplacedunderthecontrolcabinetasmuchaspossible.ThePLCispreferablyinstalledintheupperpartoftheelectriccabinet,andthearrangementofthePLCanditssystemcomponentsshouldbeawayfromthemaincircuit,switchingpowersupplyandtransformertopreventinterference.Dependingontheactualsituation,thetransformercanbeplacedonthebottomofthecontrolcabinetandprotectedbyatransparentacrylicplate.变压器、伺服驱动器、变频器等应尽量布置于控制柜下方,PLC优先安装在电柜上部,且PLC及其系统部件的布置要远离主回主路、开关电源及变压器,防止干扰。视实际情况可以将变压器布置于控制柜底部,并采用透明亚克力板做防护。10)Wheninstallingmultipleinvertersinthesamecontrolcabinet,itshouldbeconsideredtobeinstalledsidebysideinparallel,andtheinstallationclearancemeetsthecomponentinstallationspecifications.将多台变频器安装在同一控制柜时,应考虑横向并排安装,且安装间隙满足个元器件安装规范。11)Theinstallationofelectriccomponentssuchasbrakingresistorsshouldgenerallybeinstalledabovethebox.Theinstallationdirectionandpositionshouldbeconsideredtofacilitateheatdissipationandminimizethethermalinfluenceonothercomponents.Theexternalinstallationofcomponentsmustbeequippedwithprotectivedevices.Theheatingelementshouldbeinstalledinaplacewithgoodheatdissipation.Theconnectionbetweenthetwoheatingelementsshouldbemadeofheat-resistantwireorbarecopperwire.制动电阻等电热元件安装一般应安装在箱子的上方,安装方向及位置应考虑到利于散热并尽量减少对其它元件的热影响,元器件外置安装必须设置防护装置。且发热元件宜安装在散热良好的地方,两个发热元件之间的连线应采用耐热导线或裸铜线套瓷管。12)Theinstallationofthefusesandthedistancebetweenthemshouldfacilitatethereplacementofthemelt熔断器的安装及相互间的距离应便于熔体的更换。13)Thewiringspaceinthetrunkingisreservedwith30%redundancy.Thetrunkingshouldbeflatandfreeofdistortion.Theinnerwallshouldbesmoothandburr-free.Thetrunkinginterfaceshouldbestraightandtight.Theslotcovershouldbeflat,completeandfreeofwarp.Thecornerjointsshouldbebeveled.Theconnectionofthetrunkingshouldbecontinuouswithoutinterruption,andtheconnectionpointofeachslotshouldbenolessthantwo.Atthecorners,thereshouldbeafixedpointatboththebranchandtheend.线槽内布线空间预留30%的冗余,线槽应平整、无扭曲变形,内壁应光滑无毛刺,线槽接口应平直、严密,槽盖应平整、齐全、无翘角。边角连接处应采用斜角对接方式。线槽的连接应连续无间断,每节线槽的连接点应不少于两个。在转角处,分支处和端部均应有固定点。14)Thedistancebetweentheterminalsofcircuitbreakersandleakagecircuitbreakers,contactorsandothercomponentsandthelineslotshouldbenolessthan35mm.断路器和漏电断路器、接触器等元件的接线端子与线槽直线距离应不小于35mm。15)Ensurethattheelectricalcomponentsshouldbedisassembledandreplacedseparatelywithoutaffectingthefixingofothercomponentsandharnesses.确保各电器元件应能单独拆装更换,而不影响其它元件及线束的固定。16)Water,electricity,andgasshouldbeseparatedandrouted.Itisnotallowedtobeplacedinawiretrough.Theinternalisolationofthestrongandweakelectricityinthesamewiretroughisseparatedandshieldedtopreventexternalinterference.水、电、气要分开走线,不允许放在一个线槽内,同一个线槽内强电弱电内部隔离分开并注意屏蔽,防止外界干扰。17)Themaincontrolswitchoftheinverter/servocontrollerinthecabinetcannotbeprotectedbyleakagecurrent,andhigh-orderharmonicswillcausefrequentleakageprotection.柜内变频器/伺服控制器的主控开关不能带漏电保护,高次谐波会导致漏保频繁动作。18)Thepowersectionrequiresaseparatecontrolcabinet.Thecontrolsection(PLCsystem)requiresaseparatecontrolcabinet.Thestrongcontrolsectionrequiresstrongandweakelectricalseparation(theslotisseparated).强电部分要求单独一个控制柜,控制部分(PLC系统)要求单独一个控制柜,强电部分出现控制信号的需要强弱电分离(线槽分开)。7.4.2ControlCabinetWiring控制柜布线a)Thewiringinthecontrolcabinetshouldfollowthefollowingrules(Fig.3)控制柜内布线应遵循如下规定(如图3)1)Allthecircuitsinthecontrolcabinetwhichcannotbecutoffbythemainswitcharemadeoforangeline.控制柜内不能被主开关切断的回路一律采用橙色线。2)AllACpowercircuitwiringusesredcables,andzerowiringuseslightbluecables,suchasmotorandairconditioningfan.交流动力回路火线一律采用红色线缆,零线采用浅蓝色线缆,如电机、空调风扇。3)IsolationtransformerandACsideofswitchingpowersupplyalladoptredcables,andlightbluecablesareusedforzerocables隔离变压器,开关电源交流侧火线一律采用红色线缆,零线采用浅蓝色线缆4)RedcablesarealwaysusedinACcontrolloop,andlightbluecablesareusedinzerocables,suchasACrelay,ACcontactorcontrol,etc交流控制回路火线一律采用红色线缆,零线采用浅蓝色线缆,如交流继电器,交流接触器控制等。5)The24voltDCpositivepoleisconnectedbyabrowncableandthenegativepoleisconnectedbyabluecable.直流24伏正极采用棕色线缆连接,负极采用蓝色线缆连接。6)ThecontrolcabinetIOsignalisconnectedbyblackwire(exceptprefabricatedcable),andthespecificationsofotherspecialcablecolorsneedtoberecognizedbyCATLengineers.控制柜IO信号采用黑色线连接(预制电缆除外),其他特殊线缆颜色的规定,需得到CATL工程师的认同。b)Cablecolorbetweencontrolcabinets控制柜之间线缆颜色Thecontrolsignalsbetweenthecontrolboxesofthesameequipmentareconnectedbyblacksheathedwires,exceptforprefabricatedcables,andthecablenumbersareindicated.同一设备控制箱之间的控制信号采用黑色护套线连接,预制电缆除外,并标明线缆编号。c)Interlockingsignallinecolor联锁信号线颜色Theinterlockcontrolsignalsbetweendifferentdevicesareconnectedbygraysheathedwires,exceptforprefabricatedcables,andthecablenumbersareindicated.不同设备间联锁控制信号采用灰色护套线连接,预制电缆除外,并标明线缆编号。d)Controlcabinetcablenumber控制柜线缆标号Controlcabinetcablemarkingsmustfollowthefollowingprinciples控制柜线缆标号应遵循以下原则:1)ThenumbertubeisuniformlymadeofPVCinternaltoothcasing,andthespecialpartismadeofheatshrinkablesleeve.ThespecificationscorrespondtoTable2.号码管统一采用PVC内齿套管,特殊部位采用热缩套管,规格对应如表2。Table2casingspecificationsheet套管规格表Serialnumber序号Casingtype套管类型Casingspecification套管规格Casingcolor套管颜色Wireouterdiameter导线外径1PVCinnerteethcasingPVC内齿套管0.5mm²White白色φ1.5~φ1.820.75mm²White白色φ2.0~φ2.331.0mm²White白色φ2.4~φ2.641.5mm²White白色φ2.7~φ3.152.5mm²White白色φ3.2~φ3.664.0mm²White白色φ3.7~φ4.275.0mm²White白色φ4.5~φ4.786.0mm²White白色φ4.3~φ5.297.0mm²White白色φ6.8~φ7.210Heatshrinkablesleeve热缩套管2.0mm²White白色φ1.0~φ2.0112.5mm²White白色φ1.25~φ2.5123.0mm²White白色φ1.5~φ3.0133.5mm²White白色φ1.75~φ3.5144.0mm²White白色φ2.0~φ4.0155.0mm²White白色φ2.5~φ5.0166.0mm²Whiteφ3.0~φ6.0白色177.0mm²White白色φ3.5~φ7.02)Thecableisinthecorrectdirection(Figure4).线缆标号正确方向(如图4)。Whenthelinenumbertubeishorizontallyorplacedontheleftandrightsidesoftheterminalblock,thetextdirectionisreadfromlefttoright线号管水平方向或置于接线端子左右两侧时,文字方向从左往右读取;Whenthelinenumbertubeisintheverticaldirectionorplacedontheupperandlowersidesoftheterminal,thetextdirectionisreadfrombottomtotop线号管垂直方向或置于接线端子上下两侧时,文字方向从下至上读取;Whenthedirectionofthelinenumbertubeisinthefirstortriangle,thedirectionofthetextisreadfrombottomtotop线号管方向在第一、三角时,文字方向从下至上读取;Whenthelinetubedirectionisatthesecondandfourthcorners,thetextdirectionisreadfromtoptobottom线号管方向在第二、四角时,文字方向从上至下读取。3)Cablelabelinstallationprinciple线缆标号安装原则Whentheterminalblockorthepowersupplydeviceisofdifferentsizesandthearrangementisuneven,thenumberpipesshouldbealignedwitheachotherandarrangedinarow端子排或者用电设备大小不一,排列参差不齐时,号码管应相互对齐,排列成行;Whenthewireisindividuallywiredattheterminal,thenumberingtubeshouldbeclosetotheterminalside导线在端子处单个独立接线时,号码管应紧靠端子一侧;Whenthewiresarearrangedinarowonterminalsorelectricalequipment,ifthesizeoftheterminalblockorelectricalcomponentsisinconsistent,thenumberpipeshouldbeclosetotheterminalside导线在端子或者用电设备上成排接线时,端子排或电器元件大小不一致时,号码管应紧靠接线端子侧。7.4.3ComponentIdentification元器件标识Thesettingofthecomponentidentificationinthecontrolcabinetshouldfollowthefollowingprinciples控制柜内元器件标识的设置应遵循以下原则:a)Thecomponentsinthecontrolcabinetshallbemarkedwithblackandwhitedoublelabels,whicharerespectivelyattachedtothecomponentsandthemountingboard,andthelabelsarecorrect,clearandeasytoidentify.(Figure5)控制柜内元器件标识应为白底黑字双重标签,分别贴于元器件和安装板上,且标号正确、清晰,且易于识别;(如图12)b)Theindividualcomponentsofthecontrolcabinetshallbepermanentlymarkedandconformtothenameofthedrawing.Ifthepositionofthesigncannotbeattachedtothecomponent,itshouldbearrangedreasonably.Ifthelocationiscrowded,itcanbepastedintwolines.控制柜的各个元件应有永久性标识,并与图纸的名称一致。如遇标牌位置不能贴在元件上时,应就近合理布置,如位置拥挤,可分两行粘贴。c)Theequipmentthatisstillenergizedafterthemainpowerswitchofthecontrolcabinetisdisconnectedmustbesetwithawarningsign.Thecontrolcabinetitselfalsoneedstosetthelightningbolt,asshowninFigure6.控制柜主电源开关断开后仍然带电的设备必须设置警告标志,控制柜本身也需要设置闪电标识,如图6所示。d)Thenumberofincomingandoutgoingcables,source,targetandotherinformationshallbepostedonthedoorofthecontrolcabinet.Whentherearemultipleoutputvoltagelevelsinthecabinet,thevoltagelevelvalueshallbepostedonthecorrespondingpowersupplydevice.Inaddition,alarmsignsmustbeaffixednexttothe380Vor220Vpanelindicatorlights控制柜柜门上应张贴进出线电缆编号及源头、目标等信息,柜内有多个输出电压等级时,在对应电源器件上应张贴电压等级数值。另外,在380V或220V面板指示灯旁边也必须要贴上警示标识。e)Theterminalblockshallbegroupedaccordingtothewiringdiagramoftheelectriccontrolcabinet.Eachterminalshallbeequippedwithaterminalmarkingseatinfrontofit,indicatingthemarkingssuchasTX
温馨提示
- 1. 本站所有资源如无特殊说明,都需要本地电脑安装OFFICE2007和PDF阅读器。图纸软件为CAD,CAXA,PROE,UG,SolidWorks等.压缩文件请下载最新的WinRAR软件解压。
- 2. 本站的文档不包含任何第三方提供的附件图纸等,如果需要附件,请联系上传者。文件的所有权益归上传用户所有。
- 3. 本站RAR压缩包中若带图纸,网页内容里面会有图纸预览,若没有图纸预览就没有图纸。
- 4. 未经权益所有人同意不得将文件中的内容挪作商业或盈利用途。
- 5. 人人文库网仅提供信息存储空间,仅对用户上传内容的表现方式做保护处理,对用户上传分享的文档内容本身不做任何修改或编辑,并不能对任何下载内容负责。
- 6. 下载文件中如有侵权或不适当内容,请与我们联系,我们立即纠正。
- 7. 本站不保证下载资源的准确性、安全性和完整性, 同时也不承担用户因使用这些下载资源对自己和他人造成任何形式的伤害或损失。
最新文档
- 2026年建筑施工组织考试模拟试卷(含答案)
- 2026年航空航天知识竞赛太空探索考试题库带答案
- 2026年可口可乐测评题库及参考答案
- 2026年三级教育钢筋工模拟试卷带答案
- 2026年批判哲学模拟试卷(含答案)
- 2026年中职学校招聘笔试模拟试卷目(含答案)
- 2026年接线员笔试题库及参考答案
- 人工智能训练师职业技能竞赛题库带答案
- 2026年输血护理艾滋病防治题库及答案
- 2026年武装部招工模拟试卷(含答案)
- 2024河南水利与环境职业学院招聘笔试真题及参考答案详解
- 2026年钢琴考级乐理模拟试题(含答案)
- 污水管网工程施工组织设计方案
- 2026年国家安全教育大学生读本-全套课件(共11章)
- 2026年内蒙古包头市辅警人员招聘考试题库及答案
- 大皖传媒中心(安徽商报社)2026年公开招聘工作人员笔试参考题库及答案解析
- 建筑登高车专项施工方案(完-整版)
- 高盛-变革中的中国:中企出海浩荡征程从边缘市场走向核心腹地(摘要)-20260914
- 2026年道德与法治六年级上册第4课《我是中国公民》教案设计
- 铁路桥梁施工质量安全监控要点培训
- 2025年全国性体育社会组织(秋季)公开招聘人员确认表笔试历年典型考题(历年真题考点)解题思路附带答案详解
评论
0/150
提交评论