版权说明:本文档由用户提供并上传,收益归属内容提供方,若内容存在侵权,请进行举报或认领
文档简介
河北省地方计量技术规范
JJF(冀)xxxx—xxxx
电梯导轨校正检测器组校准规范
CalibrationSpecificationforAdjusting
GuideRailsofLiftsTesterSets
(报批稿)
XXXX-XX-XX发布XXXX-XX-XX实施
河北省市场监督管理局发布
JJF(冀)xxxx—xxxx
目录
引言········································································································(II)
1范围···································································································(1)
2引用文件·····························································································(1)
3术语和定义··························································································(1)
4概述···································································································(1)
5计量特性·····························································································(3)
6校准条件·····························································································(3)
6.1环境条件···························································································(3)
6.2测量标准及其他设备············································································(3)
7校准项目和校准方法··············································································(3)
7.1水平零位误差·····················································································(4)
7.2刻度尺的示值误差···············································································(4)
7.3测量线与基准面的平行度·····································································(4)
8校准结果表达·······················································································(6)
9复校时间间隔·······················································································(6)
附录A电梯导轨校正检测器组校准装置的技术要求及校准方法·························(7)
附录B刻度尺的示值测量结果不确定度评定示例···········································(8)
附录C测量线与基准面的平行度的不确定度评定示例·····································(10)
附录D校准证书内容及内页推荐格式··························································(12)
I
JJF(冀)xxxx—xxxx
电梯导轨校正检测器组校准规范
1范围
本规范适用于电梯导轨校正检测器组的校准。
2引用文件
本规范引用了下列文件:
JJF1094-2002测量仪器特性评定
GB/T22562-2008电梯T型导轨
凡是注日期的引用文件,仅注日期的版本适用于本规范;凡是不注日期的引用文件,
其最新版本(包括所有的修改单)适用于本规范。
3术语和定义
3.1导轨Guiderails
供轿厢和对重(平衡重)运行的导向部件。
3.2共面性Coplanarity
电梯的一对T型导轨同侧工作面在空间上位于同一个平面内的性质。
4概述
电梯导轨校正检测器组(以下简称仪器)是用来检测一对电梯T型导轨共面性的计量器
具,主要包括电梯导轨共面性激光检测仪、电梯校轨(导)尺和电梯导轨校正检测器等,
结构示意图分别见图1、图2和图3。其工作原理是将仪器的基准面固定在一个导轨工作面上,
并提供一条平行于基准面的测量线(电梯导轨共面性激光检测仪测量线由激光束提供,电
梯校轨(导)尺测量线由尼龙线等提供,电梯导轨校正检测器由自身提供),利用固定在另一
个导轨工作面上的刻度尺测出测量线的偏移量。
1
JJF(冀)xxxx—xxxx
图1电梯导轨共面性激光检测仪结构示意图
1—测量线;2—刻度尺;3—基准面
图2电梯校轨尺结构示意图
1—刻度尺;2—测量线;3—水准泡;4—基准面
图3电梯导轨校正检测器结构示意图
1—刻度尺;2—水准泡;3—锁紧装置;4—测量线;5—基准面
2
JJF(冀)xxxx—xxxx
5计量特性
计量特性见表1
表1计量特性要求
序号计量器具计量特性技术指标
刻度尺的示值误差不超过±0.3mm
1电梯导轨共面性激光检测仪
测量线与基准面的平行度≤1mm/2000mm
水平零位误差不大于1/4格或0.5mm
2电梯校轨(导)尺刻度尺的示值误差不超过±0.3mm
测量线与基准面的平行度≤1mm/2000mm
刻度尺的示值误差不超过±0.3mm
3电梯导轨校正检测器
测量线与基准面的平行度≤1mm/2000mm
注:以上技术指标不作为合格性判定条件,仅供参考。
6校准条件
6.1环境条件
环境温度(20±5)℃,相对湿度≤80%。校准前,电梯导轨校正检测器组与标准器平
衡温度时间不少于2小时。
6.2测量标准及其他设备
测量标准及其他设备见表2。
表2测量标准及其他设备
序号校准项目测量设备技术要求
工作面平面度
1水平零位误差水平仪零位检定器
≤0.01mm
MPE:
2刻度尺的示值误差影像测量仪
±(5+L/100)μm
平尺、T型导轨或专用电梯导轨校正检测工作面平面度
3测量线与基准面的平行度
器校准装置(其结构和规格见附录A)≤0.3mm
注:允许使用其他满足不确定度要求的标准器进行校准。
7校准项目和校准方法
校准前,检查仪器外观及各部分的相互作用,确定无影响其校准计量特性的因素后再进
行校准。
3
JJF(冀)xxxx—xxxx
7.1水平零位误差
测量前将被校仪器置在水平仪零位检定器的工作台上,待水准泡稳定后在水准泡的一
端读数a1,如图4所示,然后将被校仪器调转180°,放在工作台原位置上,按照第一次读
数的一边记下水准泡另一边的读数a2,两次读数差的一半为水平零位误差。水平零位误差
e零位用公式(1)计算:
aa
e21(1)
零位2
式中:
e零位——水平零位误差,mm或格;
a1——水准泡一端读数,mm或格;
a2——水准泡另一端的读数,mm或格。
图4水平零位误差测量示意图
1—被校仪器;2—水平仪零位检定器工作台
7.2刻度尺的示值误差
将被校仪器的刻度尺置于影像测量仪工作台上,调焦清晰瞄准刻度尺,使仪器测量线
垂直于刻线方向,在刻度尺的测量范围内均匀取5点进行测量,从测量仪读出被校刻度尺各
点的实测值,各校准点的示值误差ei用公式(2)计算,取绝对值最大者作为测量结果。
eil0-li(2)
式中:
ei——校准点的示值误差,mm;
l0——刻度尺各点的标称值,mm;
li——测量仪上读出的被校刻度尺实测值,mm。
7.3测量线与基准面的平行度
7.3.1电梯导轨共面性激光检测仪的测量线与基准面的平行度
将被校准仪器安装在电梯导轨检测器组校准装置上,即被校仪器基准面(有磁力定位
块的一侧)固定在标准器的一个工作面上,刻度尺固定在标准器的另一个工作面上,如图
4
JJF(冀)xxxx—xxxx
5所示。调整被校仪器,使激光束打在刻度尺上,读出激光光斑中心偏移零刻线的值为测量
结果。
图5电梯导轨共面性激光检测仪校准示意图
1—刻度尺;2—激光束;3—电梯导轨共面性激光检测仪;4—校准装置
7.3.2电梯校轨(导)尺的测量线与基准面的平行度
将被校准仪器安装在电梯导轨检测器组校准装置上,调整被校仪器使其水平,在两端
测量线位置上穿入尼龙线,并拉直,如图6所示,在仪器上读出尼龙线偏移左尺和右尺零刻
线的值,取绝对值最大者作为测量结果。
图6电梯校轨尺校准示意图
1、4—电梯校轨尺;2—刻度尺;3—尼龙线;5—校准装置
7.3.3电梯导轨校正检测器的测量线与基准面的平行度
将被校准仪器安装在电梯导轨检测器组校准装置上,调整被校仪器使其水平,如图7所
示,在刻度尺上读出指针偏移零刻线的值作为测量结果。
图7电梯导轨校正检测器校准示意图
1—刻度尺;2—水准泡;3—锁紧装置;4—测量线;5—校准装置
5
JJF(冀)xxxx—xxxx
8校准结果表达
经校准的仪器组出具校准证书。校准证书应给出各校准项目的测量结果及其扩展不确
定度。校准证书信息和内页格式见附录D。
9复校时间间隔
建议复校时间间隔一般不超过1年。
由于复校时间间隔的长短由电梯导轨校正检测器组的使用情况、使用者及本身质量等
诸多因素所决定,因此送校单位可根据电梯导轨校正检测器组实际使用情况自主决定复校
时间间隔。
6
JJF(冀)xxxx—xxxx
附录A
电梯导轨校正检测器组校准装置的技术要求及校准方法
A.1电梯导轨校正检测器组校准装置结构示意如图A.1所示:
图A.1电梯导轨校正检测器组校准装置结构示意图(正视图和俯视图)
A.2技术要求
电梯导轨校正检测器组校准装置的技术要求如表A.1所示。
表A.1电梯导轨检测器组校准装置的技术要求
序号参数技术要求
1工作面平面度≤0.3mm
2L1≥2000mm
3L2≥100mm
4H≥50mm
5D(16±1)mm
A.3校准方法
A.3.1工作面平面度
该校准装置的工作面平面度可以采用坐标测量机或在1级平板上用塞尺来测量。
A.3.2几何尺寸
几何尺寸可以采用经检定合格的钢直尺或其他满足要求的仪器来测量。
7
JJF(冀)xxxx—xxxx
附录B
刻度尺的示值测量结果不确定度评定示例
B.1测量方法
将被校刻度尺置于影像测量仪工作台上,在被校尺的测量范围内均匀取5点,在影像测
量仪上读出各点实测值li,得到各校准点的示值误差ei
B.2测量模型
eil0li(B.1)
式中:
ei——校准点的示值误差,mm;
l0——刻度尺各点的标称值,mm;
li——测量仪上读出被校刻度尺的实测值,mm。
B.3输入量的标准不确定度评定
B.3.1标准器引入的测量不确定度分量u1
选用的影像测量仪最大允许示值误差为±(5.0+L/100)μm,服从均匀分布,包含因子k取
3,则当L=70mm时:
5.7
u3.0μm0.003mm
13
重复性引起的不确定度分量u2
B.3.2在重复性测量条件下,用影像测量仪对刻度尺70mm位置进行十次测量,得到测量
数据(mm)69.67、69.69、69.69、69.73、69.72、69.74、69.71、69.72、69.72、69.71,实验标
准差为:s=0.02mm,即
u20.02mm
校准前被检刻度尺与与标准器平衡温度时间不少于2小时,且测量范围不超过100mm,
由温度线胀系数引入的不确定度分量为微米级别,远小于重复性引入的不确定度分量,因
此可以忽略不计。
B.4标准不确定度汇总表
标准不确定度汇总表见表B.1
B.5合成不确定度
由于不确定度分量푢1远小于푢2,故푢1忽略不计
222
uCu12u0.020.02mm
B.6扩展不确定度
取k=2,扩展不确定度为:U=2×uc=0.04mm
8
JJF(冀)xxxx—xxxx
表B.1不确定度汇总表
标准不确定度
不确定度来源标准不确定度ci|ci|u(xi)
分量
标准器-影像测量仪示值
u0.003mm10.003mm
1引入的不确定度分量
重复性引入的不确定分量0.02mm10.02mm
u2
9
JJF(冀)xxxx—xxxx
附录C
测量线与基准面的平行度的不确定度评定示例
C.1测量方法
将电梯校轨(导)尺安装在电梯导轨校正检测器组校准装置上,固定在两侧,水准泡
调平后读出测量线偏移左尺和右尺零刻线的值,取绝对值最大值为测量结果。
C.2测量模型
el(C.1)
式中:
e——测量线与基准面的平行度,mm;
l——刻度尺上读出的值,mm。
C.3输入量的标准不确定度评定
标准器引入的测量不确定度分量
C.3.1u1
标准器引入的测量不确定度分量由两部分组成:电梯导轨校正检测器组校准装置平
面度引入的测量不确定度和刻度尺最大允许示值误差引入的测量不确定度
u11u12
C.3.1.1电梯导轨校正检测器组校准装置平面度引入的测量不确定度
电梯导轨校正检测器组校准装置平面度≤0.3mm,半宽为±0.15mm,服从均匀分布,包
含因子k取3,则有:
0.15
u0.086mm
113
C.3.1.2刻度尺最大允许示值误差引入的测量不确定度
刻度尺最大允许示值误差为±0.3mm,服从均匀分布,包含因子k取,服从均匀分布,
则有:
0.3
u0.173mm
123
C.3.2人眼分辨力引起的不确定度分量u2
人眼分辨力大致为0.1mm,半宽为±0.05mm,服从均匀分布,包含因子k取,由于
进行一次测量需带入两次分辨力误差。
则有:
20.05
u20.020mm
23
C.4标准不确定度汇总表
标准不确定度汇总表见表C.1
10
JJF(冀)xxxx—xxxx
表C.1不确定度汇总表
标准不确定
不确定度来源标准不确定度ci|ci|u(xi)
度分量
电梯导轨校正检测器组校准装置
u110.086mm10.086mm
平面度引入的测量不确定度分量
刻度尺最大允许示值引入的测量
u120.173mm10.173mm
不确定度分量
u2人眼分辨力引入的不确定分量0.020mm10.020mm
C.5合成不确定度
222222
ucu11u12u20.0860.1730.0200.194mm
C.6扩展不确定度
取k=2,扩展不确定度为:U=2×uc≈0.4mm
同理,对于电梯导轨共面性激光检测仪测量线与基准面的平行度不确定评定应包含以
下分量:
表C.2不确定度汇总表
标准不确定
不确定度来源标准不确定度ci
度分量
电梯导轨校正检测器组
u11校准装置平面度引入的0.086mm10.086mm
测量不确定度分量
刻度尺最大允许示值引
0.173mm10.173mm
入的测量不确定度分量
测量重复性0.10mm10.10mm
扩展不确定度为:U=2×uc≈0.4
温馨提示
- 1. 本站所有资源如无特殊说明,都需要本地电脑安装OFFICE2007和PDF阅读器。图纸软件为CAD,CAXA,PROE,UG,SolidWorks等.压缩文件请下载最新的WinRAR软件解压。
- 2. 本站的文档不包含任何第三方提供的附件图纸等,如果需要附件,请联系上传者。文件的所有权益归上传用户所有。
- 3. 本站RAR压缩包中若带图纸,网页内容里面会有图纸预览,若没有图纸预览就没有图纸。
- 4. 未经权益所有人同意不得将文件中的内容挪作商业或盈利用途。
- 5. 人人文库网仅提供信息存储空间,仅对用户上传内容的表现方式做保护处理,对用户上传分享的文档内容本身不做任何修改或编辑,并不能对任何下载内容负责。
- 6. 下载文件中如有侵权或不适当内容,请与我们联系,我们立即纠正。
- 7. 本站不保证下载资源的准确性、安全性和完整性, 同时也不承担用户因使用这些下载资源对自己和他人造成任何形式的伤害或损失。
最新文档
- 深入实施质量提升行动大力推进质量强国建设全国质量月活动宣传带内容教案
- 信息技术四年级上可修改打印教案
- 有机化合物的结构特点人教版选修教案
- 2026年湖南外国语职业学院高职单招职业适应性测试模拟试题及答案详解
- 人工智能教育科普资源创意设计与开发在环境教育中的应用研究教学研究课题报告
- 2025年区块链在跨境电商供应链金融生态构建数据报告
- 纺织企业员工辞职报告范文合集
- 智能算法在风险预警中的作用-第5篇
- 火灾高危单位风险评估报告编制细则
- 新媒体内容运营方案与策略
- 2026陕西省森林资源管理局局属企业招聘(55人)参考考试题库及答案解析
- 生物安全培训班课件
- 2025年南京市卫生健康委员会、南京市机关事务管理局部分事业单位公开招聘卫技人员备考题库附答案详解
- 2025年贵州省贵阳市检察院书记员考试试题及答案
- 2026年江苏医药职业学院单招职业技能测试题库及答案详解一套
- 2026届上海市六校生物高一上期末达标检测模拟试题含解析
- 2025年12月嘉兴海宁水务集团下属企业公开招聘工作人员3人笔试备考重点试题及答案解析
- 2025年卫生管理(副高)考试题库及答案
- 初中道德与法治课中提升学生政治认同素养的策略研究
- 糖尿病的急救和护理
- 小学道德与法治-认识居民身份证教学课件设计
评论
0/150
提交评论