DB∕T 29-254-2018 天津市回弹法检测混凝土抗压强度技术规程_第1页
DB∕T 29-254-2018 天津市回弹法检测混凝土抗压强度技术规程_第2页
DB∕T 29-254-2018 天津市回弹法检测混凝土抗压强度技术规程_第3页
DB∕T 29-254-2018 天津市回弹法检测混凝土抗压强度技术规程_第4页
DB∕T 29-254-2018 天津市回弹法检测混凝土抗压强度技术规程_第5页
已阅读5页,还剩81页未读 继续免费阅读

下载本文档

版权说明:本文档由用户提供并上传,收益归属内容提供方,若内容存在侵权,请进行举报或认领

文档简介

DB/T29-254-2018备案号J14343-2018天津市回弹法检测混凝土抗压强度技术规程TechnicalspecificationforinspectingofconcretecompressivestrengthbyreboundmethodinTianjincity2018-07-172018-07-17发布2018-10-01实施天津市工程建设标准Technicalspecificationforinspecti主编单位:天津市建筑工程质量检测中心有限公司批准部门:天津市城乡建设委员会实施日期:2018年10月01日2018天津 12术语和符号 2 2 2 4 4 4 54检测技术 7 7 5混凝土强度计算 附录A回弹法天津地区混凝土构件侧面测区混凝土强度换算表 附录B标准差未知时计量抽样和分层计量抽样的样本容量与推定区间限值系数 216附录C回弹法检测混凝土抗压强度原始记录 21附录D回弹法检测混凝土抗压强度报告 25本规程用词说明 28引用标准名录 29条文说明 31Contents1GeneralProvisions 12TermsandSymbols 2 2 23ReboundHanmmer 4 4 5 54TestingTechnology 7 7 4.3CarbonationDepth 5CalculationofcompressiveStrengthforConcrete 5.1Calculationo 5.2CalculationofCompressiveStrengtho 5.3CalculationofCompressiveStrengthofConcreteforinspect 5.4CompilationofInspectionReports AppendixAStrengthofconcretepumpingconcretecomponentssidetestareainTianjinreboundmethodconversiontable AppendixBTheSampleVolumeandthePresumedIntervalLimitCoefficientTablefortheMeasurement8SamplingandtheStratifiedMeasurementSamplingintheUnknownStandardDeviation 21AppendixCReboundMethodStrengthTestRecordForm 21AppendixDReportforInspectionofConcreteCompressiveStrengthbyReboundMethod 25ExplanationofWordinginThisSpecification 28ListofQuotedStandards 29Addition:ExplanationofProvisons 311.0.1为提高回弹法在天津地区检测预拌混凝土抗压强度(以下简称混凝土强度)的精度,规范操作方法,制定本规程。1.0.2本规程适用于预拌混凝土强度检测,不适用于表层与内部质量有明显差异或内部存在缺陷的混凝土强度检测。1.0.3使用回弹法进行检测的人员,应经过专业技术培训。1.0.4回弹法检测混凝土强度除应符合本规程外,尚应符合国家及天津地方现行有关标准的规定。22术语和符号2.1术语2.1.1测区testarea检测混凝土强度时布置在构件表面的一个测试单元。2.1.2测点testpoint测区内的一个回弹检测点。2.1.3测区混凝土强度换算值conversionvalueofconcretecompressivestrengthoftestarea由测区的平均回弹值和碳化深度值通过测强曲线或测区强度换算表得到的测区现龄期混凝土强度值。2.1.4构件混凝土强度推定值estimationvalueofcompressivestrengthofconcreteforstructuralmember构件中相应于强度换算值总体分布中保证率不低于95%的混凝土强度值。2.1.5检验批混凝土强度推定区间estimationvalueofcompressivestrengthofconcreteforinspectionlot由一定构件组成的检验批中对样本进行统计分析并应用一定的规则得到的代表检验批总体性能的统计区间。2.2符号dm——测区的平均碳化深度值。fc,i——第i个测区混凝土强度换算值。fcor,m——芯样试件混凝土强度平均值。fcu,m——同条件立方体试块混凝土强度平均值。fc,m0——对应于钻芯部位或同条件试块回弹测区混凝土强度换算值的平均值。fcor,i——第i个混凝土芯样试件的抗压强度。fcu,i——第i个混凝土立方体试块的抗压强度。fc,i0——修正前第i个测区的混凝土强度换算值。fc,i1——修正后第i个测区的混凝土强度换算值。f,min——结构或构件中测区混凝土强度换算值的最小值。fcu,e——结构或构件混凝土强度推定值。fcu,u——推定区间上限值。fcu,l——推定区间下限值。k0.05,u、k0.05,l——推定区间上限值系数和推定区间下限值系数。mfc——测区混凝土强度换算值的平均值。mΔf——推定区间上限与下限的均值。Sfc——结构或构件测区混凝土强度换算值的标准差。Ri——测区第i个测点的回弹值。Rm——测区或试块的平均回弹值。△tot——测区混凝土强度修正量。f——推定区间上限与下限的差值。43.1技术要求3.1.1回弹仪可为数字式的,也可为指针直读式的。3.1.2回弹仪应具有产品合格证及计量检定证书,并应在回弹仪的明显位置上标注名称、型号、制造厂名(或商标)、出厂编号、检定有效期等。3.1.3回弹仪除应符合现行国家标准《回弹仪》GB/T9138的规定外,尚应符合下列规定:1水平弹击时,在弹击锤脱钩瞬间,回弹仪的标称能量应为2.207J;2在弹击锤与弹击杆碰撞的瞬间,弹击拉簧应处于自由状态,且弹击锤起跳点应位于指针指示刻度尺上“0”处;3在洛氏硬度HRC为60±2的钢砧上,回弹仪的率定值应为80±2;4数字式回弹仪应带有指针直读示值系统,数字显示的回弹值与指针直读示值相差不应超过1。3.1.4回弹仪使用时的环境温度应为(-4~40)℃。3.2检定3.2.1回弹仪检定周期为半年,当回弹仪有下列情况之一时,应由法定检测计量检定机构按现行行业标准《回弹仪检定规程》JJG817进行检定:1新回弹仪启用前;2超过检定有效期限;3数字式回弹仪数字显示的回弹值与指针直读示值相差大于4经保养后,在钢砧上的率定值不合格;5遭受严重撞击或其他损害。3.2.2回弹仪的率定试验应符合下列规定:1率定试验应在室温为(5~35)℃的条件下进行;2钢砧表面应干燥、清洁,并应稳固地平放在刚度大的物体3回弹值应取连续向下弹击三次的稳定回弹结果的平均值;4率定试验应分四个方向进行,且每个方向弹击前,弹击杆应旋转90度,每个方向的回弹平均值均应为80±2。3.2.3回弹仪率定试验所用的钢砧应每2年送授权计量检定机构检定或校准。3.3保养3.3.1当回弹仪存在下列情况之一时,应进行保养:1回弹仪弹击超过2000次;2在钢砧上的率定值不合格;3对回弹测试值有怀疑时。3.3.2回弹仪的保养应按下列步骤进行:1先将弹击锤脱钩,取出机芯,然后卸下弹击杆,取出里面的缓冲压簧,并取出弹击锤、弹击拉簧和拉簧座。62清洁机芯各零部件,并应重点清理中心导杆、弹击锤和弹击杆的内孔及冲击面。清理后,应在中心导杆上薄薄涂抹钟表油,其他零部件不得抹油。3清理机壳内壁,卸下刻度尺,检查指针,其摩擦力应为(0.5~0.8)N。4对于数字式回弹仪,还应按产品要求的维护程序进行维护。5保养时,不得旋转尾盖上已定位紧固的调零螺丝,不得自制或更换零部件。6保养后应按本规程第3.2.2条的规定进行率定。3.3.3回弹仪使用完毕,应使弹击杆伸出机壳,并应清除弹击杆、杆前端球面以及刻度尺表面和外壳上的污垢、尘土。回弹仪不用时,应将弹击杆压入机壳内,经弹击后按下按钮,锁住机芯,然后装入仪器箱。仪器箱应平放在干燥阴凉处。当数字式回弹仪长期不用时,应对电池进行保养。4检测技术4.1一般规定4.1.1适用范围1符合下列条件的预拌混凝土,测区强度应按本规程附录A进行强度换算:1)混凝土采用的水泥、砂石、外加剂、掺合料、拌合用水符合国家现行有关标准;2)采用普通成型工艺;3)采用符合国家标准规定的模板;4)蒸汽养护出池经自然养护7d以上,且混凝土表层为干燥状态;5)自然养护且龄期为(14~1000)d;6)抗压强度为(20.0~60.0)MPa。2当有下列情况之一时,测区混凝土强度不得按本规程附录A进行强度换算:1)特种成型工艺制作的混凝土;2)检测部位曲率半径小于250mm;3)潮湿或浸水混凝土。4.1.2采用回弹法检测混凝土强度时所需资料1当进行质量评价时,应具有下列资料:1)工程名称,责任主体单位,混凝土供应单位;2)必要的工程设计文件;3)材料的质量证明文件;84)施工资料;5)检测原因。2当进行性能检测时,宜提供上述资料,3当无法提供相应文件时,应在报告中进行说明。4.1.3回弹仪在使用前后,均应在钢砧上做率定试验,并应符合本规程第3.2.2条的规定。4.1.4混凝土强度检测可分为单个构件检测和批量检测。1单个构件检测:检测对象为单个构件,且检测结果为该构件混凝土强度推定值。2批量检测:适用于混凝土生产工艺、强度等级相同,原材料、配合比、养护条件基本一致、龄期相近且质量状况相似的同类构件。检测结果为检验批混凝土强度推定区间。4.1.5当对批量进行检测时,应在检验批中随机抽取构件,抽取构件的最小数量不宜小于表4.1.5的限定值。表中检测类别A适用于一般施工质量的检测,检测类别B适用于结构质量或性能的检测,检测类别C适用于结构质量或性能的严格检测或复检。检测批中所有构件的数量检测类别和抽取构件的最小数量检测批中所有构件的数量检测类别和抽取构件的最小数量ABCABC2-8223501-120032809-152351201-3200502003583201-100008020031526-505810001-3500031550051-9052035001-15000020050080091-15082032150001-500000315800151-2803250>5000005002000281-500205080-----------------4.1.6测区应符合下列规定:1单个构件检测时,构件布置的测区数不宜少于10个;当受检构件某一方向尺寸不大于4.5m且另一方向尺寸不大于0.3m时,构件的测区数量可适当减少,但不应少于5个;2批量检测时,每个构件布置的测区数不应少于5个,且测区总数不应少于20个;3相邻两测区的间距不应大于2m,测区离构件端部或施工缝边缘的距离不宜大于0.5m,且不宜小于0.2m。4测区应选在能使回弹仪处于水平方向的混凝土浇筑侧面。5测区宜布置在构件的两个对称的可测面上,当不能布置在对称可测面上时,也可布置在同一可测面上,且应均匀分布。在构件的重要部位及薄弱部位应布置测区,并应避开预埋件。6测区的面积不宜大于0.04m2。7测区表面应为混凝土原浆面,并应清洁、平整,不应有疏松层、浮浆、油垢、涂层以及蜂窝、麻面。8对于弹击时产生颤动的薄壁、小型构件,应进行固定。4.1.7测区应标有清晰的编号,并宜在记录纸上绘制测区布置示意图和描述外观质量情况。4.1.8当检测条件与本规程4.1.1条的适用条件有较大差异时,可采用在构件上钻取的混凝土芯样或同条件试块对测区混凝土强度换算值进行修正。对同一强度等级混凝土修正时,芯样数量不应少于6个,公称直径宜为100mm,小直径芯样数量不应少于9个。芯样应在测区内钻取,每个芯样应只加工一个试件,芯样的制作应按照现行标准《钻芯法检测混凝土强度技术规程》JGJ/T384的规定执行。用同条件立方体试块修正时,试块数量不应少于6个,试件边长应为150mm。计算时,测区混凝土强度修正量及测区混凝土强度换算值的修正应符合下列规定:1修正量应按下列公式计算Δtot=fcor,m-fc,m0(4.1.6-1)Aor=Jun-□mo(4.1.6-2)式中:Δfcor,mfcu,mfffcor,iffn(4.1.6-3)(4.1.6-4)(4.1.6-5)——测区混凝土强度修正量(MPa)精确到0.1MPa;——芯样试件混凝土强度平均值(MPa),精确到——150mm同条件立方体试块混凝土强度平均值(MPa),精确到0.1MPa;——对应于钻芯部位或同条件立方体试块回弹测区混凝土强度换算值的平均值(MPa),精确到第i个混凝土芯样试件的抗压强度;——第i个混凝土立方体试块的抗压强度;——对应于第i个芯样部位或同条件立方体试件测区回弹值和碳化深度值的混凝土强度换算值,可按本规程附录A查表取值;——芯样或试块数量。2测区混凝土强度换算值的修正应按下列公式计算:fci1=fc,i0+Δtot(4.1.6-6)式中:f——第i个测区修正前的混凝土强度换算值(MPa),精确到0.1MPa;fc,1i——第i个测区修正后的混凝土强度换算值(MPa),精确到0.1MPa。4.2回弹值测量4.2.1测量回弹值时,回弹仪的轴线应始终垂直于混凝土检测面,并应缓慢施压,准确读数,快速复位。4.2.2每一测区应读取16个回弹值,每一测点的回弹值读数应精确至1。测点宜在测区范围内均匀分布,相邻两测点的净距离不宜小于20mm;测点距外露钢筋、预埋件的距离不宜小于30mm;测点不应在气孔或外露石子上,同一测点应只弹击一次。回弹值可按本规程附录C的格式填写。4.3碳化深度值测量4.3.1回弹值测量完毕后,应在有代表性的测区上测量碳化深度值,测点数不应少于构件测区数的30%,应取其平均值作为该构件每个测区的碳化深度值。当碳化深度值极差大于2.0mm时,应在每一测区分别测量碳化深度值。碳化深度值可按本规程附录C的格式填写。4.3.2碳化深度值的测量应符合下列规定:1可采用工具在测区表面形成直径约15mm的孔洞,其深度应大于混凝土的碳化深度;2应清除孔洞中的粉末和碎屑,且不得用水擦洗;3应采用浓度为1%~2%的酚酞酒精溶液滴在孔洞内壁的边缘处,当已碳化与未碳化界线清晰时,应采用碳化深度测量仪测量已碳化与未碳化混凝土交界面到混凝土表面的垂直距离,并应测量3次,每次读数应精确至0.25mm;4应取三次测量的平均值作为检测结果,并应精确至0.5mm。5混凝土强度计算5.1测区混凝土强度计算5.1.1计算测区平均回弹值时,应从该测区的16个回弹值中剔除3个最大值和3个最小值,其余的10个回弹值应按下式计算:式中:Rm——测区的平均回弹值,精确至0.1;Ri——测区第i个测点的回弹值。5.1.2构件第i个测区混凝土强度换算值,应由本规程第5.1.1条所求得的平均回弹值(Rm)及本规程第4.3节所求得的平均碳化深度值(dm)按本规程附录A查表得出。5.2构件混凝土强度计算5.2.1构件的测区混凝土强度平均值应根据各测区的混凝土强度换算值计算,当测区数大于等于10个时,应同时计算强度标准差。平均值及标准差按下列公式计算:式中:mf——测区混凝土强度换算值的平均值(MPa),精确至0.1MPa;n——对于单个检测的构件,取一个构件的测区数;对批量检测的构件,取被抽检构件测区数之和;Sf——结构构件测区混凝土强度换算值的标准差(MPa精确至0.01MPa。5.2.2构件的现龄期混凝土强度推定值(fcu,e)应按下列公式确定:1当构件测区数少于10个时,应按下式计算:fcu,e=fc,min(5.2.2-1)式中:fc,min——构件中测区混凝土强度换算值的最小值。2当构件的测区强度值中出现小于20.0MPa时,应按下式确fcu,e<20.0MPa(5.2.2-2)3当构件的测区强度值中出现大于60.0MPa时,应按下式确fcu,e=fc,min(5.2.2-3)4当构件测区数不少于10个时,应按下式计算:JU=m:-1.64s:(5.2.2-4)5.3检验批混凝土强度计算5.3.1对符合正态分布的性能参数可对该参数总体特征值或总体均值进行推定,推定时宜提供被推定值的推定区间,标准差未知时计量抽样和分层计量抽样的推定区间限值系数可按附录B的规定确定,推定区间上限与下限所构成推定区间的置信度为0.90。5.3.2批量检测混凝土抗压强度时,检验批混凝土抗压强度推定区间上限值、下限值、上限与下限差值及其均值应按下列公式计算:fcu,u=mfc-k0.05,uSfc(fcu,l=mfu-k0.05,lSfu(5.3.2-2)Δfcu,e=fcu,u-fcu,l(5.3.2-3)(5.3.2-4)式中:fcu,u——推定区间上限值,精确至0.1MPa;fcu,l——推定区间下限值,精确至0.1MPa;k0.05,u、k0.05,l——推定区间上限值系数和下限值系数,按本规程附录B查得;Δf——推定区间上限与下限的差值,精确至0.1MPa;mΔf——推定区间上限与下限的均值,精确至5.3.3检验批混凝土抗压强度的推定应符合下列规定:1当推定区间上限与下限差值不大于5.0MPa和0.1mΔf两者之间的较大值时,检验批混凝土抗压强度推定值可根据实际情况在推定区间内取值。2当推定区间上限与下限差值大于5.0MPa和0.1mΔf两者之间的较大值时,宜采取下列措施之一进行处理,直至满足本条第1款的规定:1)增加样本容量,进行补充检测;2)细分检验批,进行补充检测或重新检测。3当推定区间上限与下限差值大于5.0MPa和0.1mΔf两者之间的较大值且不具备本条第2款条件时,不宜进行批量推定。5.4检验报告编写5.4.1回弹法检测混凝土抗压强度报告可按本规程附录D的格式编写。附录A回弹法天津地区混凝土构件侧面测区混凝土强度换算表平均回弹值R测区混凝土强度换算值fc,i(MPa)平均碳化深度d(mm)0.00.52.02.53.03.54.04.55.05.5≥6.025.020.1————————————25.220.420.125.420.620.420.1——————————25.620.920.620.420.125.821.220.920.620.420.1————————26.021.421.220.920.620.320.1———————26.221.721.421.120.920.620.320.126.422.021.721.421.120.920.620.320.1—————26.622.222.021.721.421.120.820.620.320.026.822.522.221.921.721.421.120.820.620.320.0———27.022.822.522.221.921.621.421.120.820.520.320.0——27.223.122.822.522.221.921.621.321.120.820.520.220.027.423.323.022.722.422.221.921.621.321.020.820.520.220.027.623.623.323.022.722.422.121.821.621.321.020.720.520.227.823.923.623.323.022.722.422.121.821.521.321.020.720.428.024.223.923.523.222.922.622.422.121.821.521.220.920.728.224.524.123.823.523.222.922.622.322.021.721.521.220.928.424.724.424.123.823.523.222.922.622.322.021.721.421.228.625.024.724.424.123.723.423.122.822.522.322.021.721.428.825.325.024.624.324.023.723.423.122.822.522.221.921.629.025.625.324.924.624.324.023.723.423.122.822.522.221.929.225.925.525.224.924.624.223.923.623.323.022.722.422.129.426.225.825.525.224.824.524.223.923.623.323.022.722.429.626.426.125.825.425.124.824.524.123.823.523.222.922.6平均回弹值R测区混凝土强度换算值fc,i(MPa)平均碳化深度d(mm)0.00.52.02.53.03.54.04.55.05.5≥6.029.826.726.426.125.725.425.124.724.424.123.823.523.222.930.027.026.726.326.025.725.325.024.724.424.023.723.423.130.227.327.026.626.325.925.625.324.924.624.324.023.723.430.427.627.326.926.626.225.925.525.224.924.624.223.923.630.627.927.627.226.826.526.225.825.525.224.824.524.223.930.828.227.827.527.126.826.426.125.825.425.124.824.424.131.028.528.127.827.427.126.726.426.025.725.425.024.724.431.228.828.428.127.727.327.026.626.326.025.625.325.024.631.429.128.728.428.027.627.326.926.626.225.925.625.224.931.629.429.028.628.327.927.627.226.826.526.225.825.525.231.829.729.328.928.628.227.827.527.126.826.426.125.725.432.030.029.629.228.928.528.127.827.427.026.726.326.025.732.230.329.929.529.228.828.428.027.727.327.026.626.325.932.430.630.229.829.429.128.728.328.027.627.226.926.526.232.630.930.530.129.729.429.028.628.227.927.527.226.826.532.831.230.830.430.029.729.328.928.528.127.827.427.126.733.031.531.130.730.329.929.629.228.828.428.127.727.327.033.231.931.431.030.630.229.829.529.128.728.328.027.627.333.432.231.831.330.930.530.129.829.429.028.628.227.927.533.632.532.131.631.230.830.430.029.729.328.928.528.127.833.832.832.432.031.531.130.730.329.929.629.228.828.428.134.033.132.732.331.831.431.030.630.229.829.529.128.728.334.233.433.032.632.131.731.330.930.530.129.729.329.028.634.433.733.332.932.532.031.631.230.830.430.029.629.228.934.634.133.633.232.832.331.931.531.130.730.329.929.529.134.834.433.933.533.132.632.231.831.431.030.630.229.829.435.034.734.333.833.432.932.532.131.731.330.930.530.129.735.235.034.634.133.733.232.832.432.031.631.230.830.430.035.435.334.934.434.033.633.132.732.331.931.431.030.630.235.635.735.234.834.333.933.433.032.632.131.731.330.930.535.836.035.535.134.634.233.733.332.932.432.031.631.230.836.036.335.935.434.934.534.033.633.232.732.331.931.531.136.236.736.235.735.234.834.333.933.533.032.632.231.831.436.437.036.536.035.635.134.734.233.833.332.932.532.031.636.637.336.836.435.935.435.034.534.133.633.232.832.331.936.837.637.236.736.235.735.334.834.433.933.533.032.632.237.038.037.537.036.536.035.635.134.734.233.833.332.932.537.238.337.837.336.836.435.935.435.034.534.133.633.232.8平均回弹值R测区混凝土强度换算值fc,i(MPa)平均碳化深度d(mm)0.00.52.02.53.03.54.04.55.05.5≥6.037.438.638.137.637.236.736.235.735.334.834.433.933.533.137.639.038.538.037.537.036.536.135.635.134.734.233.833.337.839.338.838.337.837.336.836.435.935.435.034.534.133.638.039.739.138.638.137.637.236.736.235.735.334.834.433.938.240.039.539.038.538.037.537.036.536.035.635.134.734.238.440.339.839.338.838.337.837.336.836.335.935.435.034.538.640.740.139.639.138.638.137.637.136.736.235.735.234.838.841.040.540.039.438.938.437.937.437.036.536.035.535.139.041.440.840.339.839.338.838.337.837.336.836.335.835.439.241.741.240.640.139.639.138.638.137.637.136.636.135.739.442.041.541.040.439.939.438.938.437.937.436.936.436.039.642.441.841.340.840.239.739.238.738.237.737.236.736.339.842.742.241.641.140.640.039.539.038.538.037.537.036.640.043.142.542.041.440.940.439.939.338.838.337.837.336.940.243.442.942.341.841.240.740.239.739.138.638.137.637.240.443.843.242.742.141.641.040.540.039.539.038.438.037.540.644.143.643.042.541.941.440.840.339.839.338.838.337.840.844.543.943.442.842.241.741.240.640.139.639.138.638.141.044.844.343.743.142.642.041.540.940.439.939.438.938.441.245.244.644.043.542.942.441.841.340.740.239.739.238.741.445.645.044.443.843.242.742.141.641.140.540.039.539.041.645.945.344.744.243.643.042.541.941.440.840.339.839.341.846.345.745.144.543.943.442.842.241.741.240.640.139.642.046.646.045.444.944.343.743.142.642.041.540.940.439.942.247.046.445.845.244.644.043.542.942.441.841.340.740.242.447.446.746.145.545.044.443.843.242.742.141.641.040.542.647.747.146.545.945.344.744.143.643.042.441.941.440.842.848.147.546.846.245.645.144.543.943.342.842.241.741.143.048.447.847.246.646.045.444.844.243.743.142.542.041.443.248.848.247.646.946.345.745.144.644.043.442.942.341.843.449.248.547.947.346.746.145.544.944.343.743.242.642.143.649.548.948.347.747.046.445.845.244.744.143.542.942.443.849.949.348.648.047.446.846.245.645.044.443.843.342.744.050.349.649.048.447.747.146.545.945.344.744.243.643.044.250.750.049.448.748.147.546.946.245.745.144.543.943.344.451.050.449.749.148.447.847.246.646.045.444.844.243.744.651.450.750.149.448.848.247.546.946.345.745.144.644.044.851.851.150.449.849.248.547.947.346.746.145.544.944.3平均回弹值R测区混凝土强度换算值fc,i(MPa)平均碳化深度d(mm)0.00.52.02.53.03.54.04.55.05.5≥6.045.052.251.550.850.249.548.948.247.647.046.445.845.244.645.252.551.951.250.549.949.248.648.047.346.746.145.544.945.452.952.251.550.950.249.648.948.347.747.146.545.945.345.653.352.651.951.250.649.949.348.648.047.446.846.245.645.853.753.052.351.650.950.349.649.048.447.747.146.545.946.054.053.352.752.051.350.650.049.348.748.147.546.846.246.254.453.753.052.351.751.050.349.749.048.447.847.246.646.454.854.153.452.752.051.450.750.049.448.848.147.546.946.655.254.553.853.152.451.751.050.449.749.148.547.847.246.855.654.954.153.452.852.151.450.750.149.448.848.247.547.056.055.254.553.853.152.451.851.150.449.849.148.547.947.256.355.654.954.253.552.852.151.450.850.149.548.848.247.456.756.055.354.653.953.252.551.851.150.549.849.248.547.657.156.455.754.954.253.552.852.251.550.850.249.548.947.857.556.856.055.354.653.953.252.551.851.250.549.849.248.057.957.256.455.755.054.353.652.952.251.550.850.249.548.258.357.556.856.155.354.653.953.252.551.951.250.549.948.458.757.957.256.455.755.054.353.652.952.251.550.950.248.659.158.357.656.856.155.454.653.953.252.651.951.250.548.859.558.758.057.256.555.755.054.353.652.952.251.550.949.059.959.158.357.656.856.155.454.754.053.352.651.951.249.259.558.758.057.256.555.755.054.353.652.952.251.649.4—59.959.158.357.656.856.155.454.754.053.352.651.949.6——59.558.758.057.256.555.855.054.353.652.952.249.859.959.158.357.656.956.155.454.754.053.352.650.059.558.758.057.256.555.855.054.353.652.950.259.959.158.357.656.856.155.454.754.053.350.4————59.558.758.057.256.555.755.054.353.650.6————59.959.158.357.656.856.155.454.754.050.859.558.758.057.256.555.755.054.351.0—————59.959.158.357.656.856.155.454.751.259.558.757.957.256.455.755.051.4——————59.859.158.357.656.856.155.351.659.458.757.957.256.455.751.859.859.058.357.556.856.052.0————————59.458.657.957.156.452.259.859.058.257.556.852.4—————————59.458.657.957.1值R平均回值R测区混凝土强度换算值fc,i(MPa)平均碳化深度d(mm)0.00.52.02.53.03.54.04.55.05.5≥6.052.6—————————59.759.058.257.552.859.358.657.853.059.758.958.253.2———————————59.358.553.4——————————59.758.953.660.059.253.8———————————59.654.0———————————60.0注:1表中未注明的测区混凝土强度换算值为小于20MPa或大于60MPa;2换算强度可按公式f=0.1090×R1.62附录B标准差未知时计量抽样和分层计量抽样的样本容量与推定区间限值系数样本容量n标准差未知时推定区间上限值与下限值系数0.05分位值k0.05,u(0.05)k0.05,l(0.05)60.874773.7076870.920373.3994780.958033.1872990.989873.031241.017302.910961.041272.814991.062472.736341.081412.670501.098482.614431.113972.566001.128122.523661.141122.486261.153112.452951.164232.42304201.174582.39600211.184252.37142221.193302.34896231.201812.32832241.209822.30929251.217392.29167261.224552.27530271.231352.26005281.237802.24578291.243952.23241301.249812.21984样本容量n标准差未知时推定区间上限值与下限值系数0.05分位值k0.05,u(0.05)k0.05,l(0.05)311.255402.20800321.260752.19682331.265882.18625341.270792.17623351.275512.16672361.280042.15768371.284412.14906381.288612.14085391.292662.13300401.296572.12549411.300352.11831421.303992.11142431.307522.10481441.310942.09846451.314252.09235461.317462.08648471.320582.08081481.323602.07535491.326532.07008501.329392.06499601.354122.02216701.373641.98987801.389591.96444901.402941.943761.414331.926541.424211.911911.432891.899291.440601.888271.447501.878521.453721.869841.459381.862031.464561.854971.469311.848541.473701.842652001.477771.837242501.494431.815473001.506871.799644001.524531.777765001.536711.76305附录C回弹法检测混凝土抗压强度原始记录委托编号检测日期仪器名称仪器编号检验依据构件编号构件名称构件位置构件轴号测区测区碳化深度(mm)平均值(mm)构件编号构件名称构件位置构件轴号测区测区碳化深度(mm)平均值(mm)1柱□梁□顶板□墙□承台□_层__m3柱□梁□顶板□墙□承台□_层__m2柱□梁□顶板□墙□承台□_层__m4柱□梁□顶板□墙□承台□_层__m检验:记录:工程名称:委托日期:年月日检验日期:年月日工程部位:构件名称:柱□梁□墙□构件编号:验证样品:符合□不符合□检验环境温度:仪器型号编号:测区回弹值R碳化深度值d(mm)平均化深度值dm(mm)平均值Rm测区混凝土换算值f(MPa)12345678123456789强度计算测区混凝土强度换算值的平均值测区混凝土强度换算值的标准差当n<10,混凝土强度推定值:f=f=MPa;当n≥10,混凝土强度推定值:fcu,e=mf-1.645Sf当构件测区强度值中出现小于20.0MPa时,f<20.0MPa;当构件测区强度值中出现大于60.0MPa时,fcu,e=fc,min=MPa。检验依据测区布置示意图校核:检验:附录D回弹法检测混凝土抗压强度报告检测编号:工程名称:委托单位:检验类别:XXXXXXXXXXXXXXXXXXXXXXXXXXXX检测编号:工程名称工程地点委托单位检测日期检测类别检测项目检测仪器检验依据监理单位监督单位检测结论签发日期:年月日备注无批准:审核:编写:检测编号:一.工程概况二.有关设计参数三.检测仪器四.检测项目五.检测依据六.检测结果本规程用词说明1为便于在执行本规程条文时区别对待,对要求严格程度不同的用词说明如下:1)表示很严格,非这样做不可的:正面词采用“必须”,反面词采用“严禁”;2)表示严格,在正常情况均应这样做的:正面词采用“应”,反面词采用“不应”或“不得”;3)表示允许稍有选择,在条件许可时首先应这样做的:正面词采用“宜”,反面词采用“不宜”;4)表示有选择,在一定条件下可以这样做的,采用“可”。2条文中指明应按其他有关标准执行的写法为:“应符合……的规定”或“应按……执行”。引用标准名录1《普通混凝土力学性能试验方法标准》GB/T500812《建筑结构检测技术标准》GB/T503443《混凝土结构现场检测技术标准》GB/T507844《回弹仪》GB/T91385《回弹法检测混凝土抗压强度技术规程》JGJ/T236《钻芯法检测混凝土强度技术规程》JGJ/T3847《回弹仪检定规程》JJG817天津市工程建设标准天津市回弹法检测混凝土抗压强度技术规程DB/T29-254-2018J14343-2018条文说明2018天津 33 34 4检测技术 38 41 415混凝土强度计算 42 42 42 43 431.0.1统一天津地区回弹仪检测方法,保证天津地区检测精度是本规程制定的目的。回弹法在中国已使用几十年,应用非常广泛,为保证天津地区回弹法检测的准确性和可靠性,编制本标准。1.0.2本规程提到的混凝土是指用水泥作胶凝材料,砂、石作骨料;与水(可含外加剂和掺合料)按一定比例配合,经搅拌而得的密度为2000kg/m3~2800kg/m3的混凝土。1.0.3由于本规程规定的方法是处理混凝土质量问题的依据,若不进行统一培训,则会对同一结构构件混凝土强度的推定结果存在着因人而异的混乱现象,因此本条规定凡从事本项检测的人员应经过专业技术培训。1.0.4凡本规程涉及的其它有关方面,例如钻芯取样作业时的安全技术和劳动保护等,均应遵守相应的标准规范。3.1技术要求3.1.1随着光电子技术在回弹仪上的应用,国内数字式回弹仪的技术水平有了很大的提高,技术上已经成熟,数字回弹仪性能已相当稳定。为了推广和应用先进技术,提高工作效率,减少人为产生的读数、记录、计算等过程出现差错,因此,本条规定可使用数字式回弹仪也可使用传统指针直读式回弹仪,但推荐使用数字式的。3.1.2由于回弹仪为计量仪器,因此在回弹仪明显的位置上要标明名称、型号、制造厂名、生产编号、生产日期、检定有效期。3.1.3回弹仪的质量及测试性能直接影响混凝土强度推定结果的准确性。根据对回弹仪的测试性能试验研究和应用经验,回弹仪的标准状态是统一仪器性能的基础,是使回弹法广泛应用于现场的关键所在;只有采用质量统一,性能一致的回弹仪,才能保证测试结果的可靠性,并能在同一水平上进行比较。在此基础上,提出了下列回弹仪标准状态的各项具体指标:1水平弹击时,对于中型回弹仪弹击锤脱钩的瞬间,回弹仪的标准能量E,即中型回弹仪弹击拉簧恢复原始状态所作的功为:E=KL2=×784.5×0.0752=2.207J式中:K——弹击拉簧的刚度系数(N/m);L——弹击拉簧工作时拉伸长度(m)。2弹击锤与弹击杆碰撞瞬间,弹击拉簧应处于自由状态,此时弹击锤起跳点应相应于刻度尺上的“0”处,同时弹击锤应在相应于刻度尺上的“100”处脱钩,也即在“0”处起跳。3检验回弹仪的率定值是否符合80±2的作用是:检验回弹仪的标准能量是否为2.207J;回弹仪的测试性能是否稳定;机芯的滑动部分是否有污垢等。当钢砧率定值达不到率定值时,不允许用混凝土试块上的回弹值予以修正;更不允许旋转调零螺丝人为地使其达到率定值。试验表明上述方法不符合回弹仪测试性能,并破坏了零点起跳亦即使回弹仪处于非标准状态。此时,可按本规程3.3节要求进行常规保养,若保养后仍不合格,可返厂修理。4现在绝大多数数字式回弹仪都是在传统机械构造和标准技术参数的基础上实现回弹值的数字化采样的,即现有数字式回弹仪所得到的回弹值采样系统都是把回弹仪的指针示值实现数字化采样。也只有这种形式的数字回弹仪才符合现行回弹法技术规程的要求。3.1.4环境温度异常时,对回弹仪的性能有影响,故规定了其使用时的环境温度。3.2检定3.2.1检定混凝土回弹仪的单位应由当地主管部门授权,并按照国家计量检定规程《混凝土回弹仪》JJG817进行。开展检定工作要备有回弹仪检定器、拉簧刚度测量仪等设备。目前有的单位不具备检定回弹仪的资格及条件,甚至不懂得回弹仪的标准状态,进行调整调零螺丝以使其钢砧率定值达到80±2的错误方法;有的没有检定设备也开展检定工作,以至于影响了回弹法的正确推广应用。因此,有必要强调检定单位的资格和统一检定回弹仪的方法。3.2.2率定试验时的环境温度应在回弹仪使用温度的范围内,考虑到率定试验一般都在室内,故温度范围略小于回弹仪使用温度的范围。因用钢砧做率定为判断回弹仪是否正常的方法,钢砧的自身状态及放置状态极为重要,如钢砧表面有异物或放置在不稳定的基底上,会直接影响回弹仪率定的准确性,亦有可能会伤到周边的人员。在钢砧上对回弹仪进行率定时,取连续向下弹击3次的稳定回弹平均值,弹击杆应分3次旋转,每次旋转宜为90°,注意:不是人旋转。3.2.3钢砧的钢芯硬度和表面状态会随着弹击次数的增加而变化,故规定钢砧应每两年校验一次。3.3保养3.3.1本条主要规定了回弹仪常规保养的要求。检测人员根据经验怀疑检测数据异常,检测数据与真实数据存在差异时,应对回弹仪进行保养。3.3.2本条给出了回弹仪常规保养的步骤。进行常规保养时,必须先使弹击锤脱钩后再取出机芯,否则会使弹击杆突然伸出造成伤害。取机芯时要将指针轴向上轻轻抽出,清理机壳内壁之前宜先取出指针轴和指针滑块,以免造成指针片折断。此外,各零部件清洗完后,不能在指针轴上抹油。否则,使用中由于指针轴的污垢,将使指针摩擦力变化,直接影响检测结果。数字式回弹仪结构和原理较复杂,其厂商已提供了使用和维护手册,应按该手册的要求进行维护和保养。3.3.3回弹仪每次使用完毕后,应及时清除表面污垢。不用时,应将弹击杆压入仪器内,必须经弹击后方可按下按钮锁住机芯,如果未经弹击而锁住机芯,将使弹击拉簧在不工作时仍处于受拉状态,极易因疲劳而损坏。存放时回弹仪应平放在干燥阴凉处,如存放地点潮湿将会使仪器锈蚀。数字回弹仪内的电池长期不用,应对电池进行维护。4检测技术4.1一般规定4.1.1为了适应天津地区预拌混凝土技术的发展,提高回弹法检测的精度,将1409组预拌混凝土试块进行回归,得到回弹法天津地区混凝土测强曲线(天津市建委科研项目编号:2011-4)。该测强曲线的平均相对误差(δ)为±10.5%,相对标准差为er为13.6%,满足JGJ/T23中关于地区测强曲线的要求。天津地区在建建筑物的混凝土基本采用泵送混凝土浇筑,混凝土的内在特性与传统混凝土在外加剂、骨料粒径、施工工艺方面存在明显差异,导致混凝土的碳化深度的变化与传统混凝土不同。本条款进一步规定了测强曲线的适应范围。例如:加压振动或离心法成型等特种工艺,超出了该测强曲线的使用范围;混凝土表面湿度对回弹法测强影响很大,应等待混凝土表面干燥后再进行检测。4.1.2本条规范了回弹法检测混凝土强度应有资料及宜有资料。当所需资料缺失

温馨提示

  • 1. 本站所有资源如无特殊说明,都需要本地电脑安装OFFICE2007和PDF阅读器。图纸软件为CAD,CAXA,PROE,UG,SolidWorks等.压缩文件请下载最新的WinRAR软件解压。
  • 2. 本站的文档不包含任何第三方提供的附件图纸等,如果需要附件,请联系上传者。文件的所有权益归上传用户所有。
  • 3. 本站RAR压缩包中若带图纸,网页内容里面会有图纸预览,若没有图纸预览就没有图纸。
  • 4. 未经权益所有人同意不得将文件中的内容挪作商业或盈利用途。
  • 5. 人人文库网仅提供信息存储空间,仅对用户上传内容的表现方式做保护处理,对用户上传分享的文档内容本身不做任何修改或编辑,并不能对任何下载内容负责。
  • 6. 下载文件中如有侵权或不适当内容,请与我们联系,我们立即纠正。
  • 7. 本站不保证下载资源的准确性、安全性和完整性, 同时也不承担用户因使用这些下载资源对自己和他人造成任何形式的伤害或损失。

评论

0/150

提交评论