1、CHAPTER 7 SIGNAL CONDITIONING FOR REACTANCE VARIATION SENSORS,1. INTRODUCTION To obtain a useful signal from the variation of a capacitance or an inductance, we need at least an ac voltage supply for the component and some method for detecting the variations due to the detected quantity. If the inte

2、nded application requires the use of an ADC (analog-to-digital converter), the signal at its input must be dc and within a standard amplitude range. In this chapter we describe several circuits that allow us to obtain a useful signal from variable reactance sensors.,Here we emphasize the new concept

3、s that arise from working with alternating voltages, without repeating concepts similar to those for dc measurements such as those relating to interference. However, we describe variable oscillators, which can also be applied to resistive sensors. For the case of variable transformer sensors intende

4、d for angle measurement, the specific converters will be discussed here.,After measuring the physical quantities, we consider the following final uses of the measurement: immediate analog presentation, conversion to digital, conversion to a variable frequency signal ,voltage telemetry, and current t

5、elemetry. Variable reactance sensors can be classified into the following groups: C0C,L0L ,and sensors that offer an amplitude-modulated alternating signal, such as LVDTs, synchros, and resolvers.,2. PROBLEMS AND ALTERNATIVES,Signal conditioning for all of these sensors must include a supply of exci

6、ting alternating current. For capacitive sensors the values for the capacitances are in general smaller than 100 pF. The supply frequency must then be high enough in order to yield reasonable values for their impedances; typical values range from 10KHz to 100MHz. Because their output impedance is ve

7、ry high we frequently use shielded cables for connecting them.,But this adds a capacitance in parallel with that of the sensor, resulting in a reduced sensitivity and a decreased linearity. Furthermore, if there is any relative movement between cable conductors and the insulating dielectric, the err

8、or can become very serious. The usual solution is to place the electronic circuits as close as possible to the sensor, thus using short cables and even rigid ones, and to apply driven shield techniques or impedance transformers.,When the measurement system requires all measured quantities to be conv

9、erted to dc voltages, some available options for the sensors working at alternating frequency, are peak detection, rms measurement, and mean value calculation after rectifying. A common solution is to apply Ohms law. A change in impedance can be detected by measuring the change in current when a con

10、stant alternating voltage is supplied to it, or by the change in the drop in voltage across it when driven by a constant alternating current.,When the quality factor Q for the sensor is not very high, all the above methods imply the measurement of two components of the output signal: the one in phas

11、e and the one out of phase with respect to the supply signal; but only the in-phase signal carries useful information about the measured variable. In addition the actual impedance variations are sometimes very small, and usually there are stray capacitances interfering with the changes to be measure

12、d. Thus reactance measurement techniques based on constant current or voltage supply and Ohms law are unusual in sensors.,This Circuit applies the constant current supply method to a capacitive displacement sensor based on the variation of the separation of plates in a parallel plate capacitor.,The

13、interesting point for the circuit in the Figure is that it provides an output voltage proportional to the measured distance, in spite of the nonlinear relationship between the capacity and the distance.,If the capacitance changes in the form,then the output voltage is,3. AC BRIDGES,(1)Sensitivity an

14、d Linearity The classical solution to cancel the constant term appearing at the output of a voltage divider, is to use a bridge measurement configuration. Assuming that reactive impedances are involved, this bridge must be supplied by a constant current or voltage. When in the bridge only one of the

15、 arms has a linear variation with respect to the quantity to be measured, , Figure a, the output is,which shows a nonlinear relationship with x.,But in the case of a differential sensor where impedances are placed in adjacent arms, in Figure a, the output is,and therefore is proportional to x, furth

16、ermore shows that this configuration will cancel all changes that are simultaneous for both sensors (like the changes due to temperature). This makes ac bridges the most attractive solution for differential sensors. The impedances for the two remaining bridge arms not occupied by the sensor are chos

17、en depending on the type of sensor. For the case of a differential inductive sensor, resistors can be used. Whenever resistive losses in sensor coils are small, changes in resistances can be neglected, and the circuit in Figure b gives a linear output.,For differential capacitive sensors, and even f

18、or single capacitance sensors when nonlinearity is not of great concern, the errors due to parasitic impedances to ground are very large if resistors are used for the remaining bridge arms. These errors can be reduced by using a bridge with two tightly coupled inductive arms having an accurate windi

19、ng ratio and a central terminal, forming what is known as a transformer bridge . It consists of a transformer (Figure a below) or autotransformer (Figure b below) with a central terminal.,This yields three terminals to form the two fixed arms of a bridge. When the oscillator (device 1) is applied to

20、 the external terminals of the windings, we have a voltage transformer, and the detector (device 2) is connected between the central terminals of the sensor and the transformer.,For capacitive sensor conditioning, the central terminal is usually grounded. By so doing, stray capacitances to ground Cp

21、 have a negligible influence on bridge balance. This is because in a voltage transformer, coilsN3 and N4 are the ones that determine the voltage ratio across Z1 and Z2, assuming that the voltage generator has a low output impedance. For a current transformer, assuming that when in balance the flux d

22、ensity in the core is zero. There is no drop in voltage across capacitances Cp, and therefore these have no effect.,This allows us to detect very small changes in capacity even in the presence of much larger stray capacitances. To this very important advantage we have to add that the voltage or curr

23、ent ratio are very constant both with time and temperature, as they only depend on N3/N4. Furthermore this ratio can be changed very accurately through a broad range of values by placing intermediate terminals in the transformer. When a three-winding transformer is used, there is a galvanic isolatio

24、n between the oscillator and detector. This permits both to be grounded without requiring differential measurements when both grounds are different.,The figure shows the equivalent circuit for the bridges circuit, where Zd is the detector input impedance.,Vs and Zs are, respectively, the Thevenin equivalent source voltage and impedance. For a voltage transformer having N3=N4, we have Zs=Z1/Z2 and,Suppose that the impedance variations are linear. Then for a capacitive differentia

温馨提示

  • 1. 本站所有资源如无特殊说明,都需要本地电脑安装OFFICE2007和PDF阅读器。图纸软件为CAD,CAXA,PROE,UG,SolidWorks等.压缩文件请下载最新的WinRAR软件解压。
  • 2. 本站的文档不包含任何第三方提供的附件图纸等,如果需要附件,请联系上传者。文件的所有权益归上传用户所有。
  • 3. 本站RAR压缩包中若带图纸,网页内容里面会有图纸预览,若没有图纸预览就没有图纸。
  • 4. 未经权益所有人同意不得将文件中的内容挪作商业或盈利用途。
  • 5. 人人文库网仅提供信息存储空间,仅对用户上传内容的表现方式做保护处理,对用户上传分享的文档内容本身不做任何修改或编辑,并不能对任何下载内容负责。
  • 6. 下载文件中如有侵权或不适当内容,请与我们联系,我们立即纠正。
  • 7. 本站不保证下载资源的准确性、安全性和完整性, 同时也不承担用户因使用这些下载资源对自己和他人造成任何形式的伤害或损失。

评论

0/150

提交评论