1、25.05.08,Seite 1,Setup DIG000/OP1000,Dez 2008 BUA,25.05.08,Seite 2,OL81/DIG000/DM4000,Training overview :,Interface structure How to Start-up the new components 1. OP1000 (applicationsoftware) 2. DIG000 (applicationsoftware),25.05.08,Seite 3,DIG000 with MasterLogic and OP1000 Network,Ethernet,Can Gr

2、oup 07 with other sensors OL80 FR. Fx. FE.,Network 1,DIG000 Software: Pc0016-8003M + Application software xxx.xxx Possible communications Mitshubishi Siemens Beckhoff . Standard Ethernet: Software Pc0016-8002M Ethernet Ip Software Pc0016-8010M EGD,OP 1000,PLC,Ethernet Switch X8; 24V DC (z.B. 326491)

3、,Can Group 07 with other sensors OL80 FR. Fx. FE.,Network 2,DIG000,DIG000,25.05.08,Seite 4,How to Start-up the new components,Change the PC-Ethernet settings Download Software to the DIG000 Set the ip-address of the OP1000 Panel Download software to the OP1000 Panel Download PLC-software in DIG000 C

4、heck the Dongle Value EK 5101,25.05.08,Seite 5,How to Start-up the new components,1. Change the PC-Ethernet settings,To get a ethernet connection between two devices you need a few conditions A ethernet connection exists of following parts.,ip-address010.006.002.003 Netmask255.255.000.000 Gateway000

5、.000.000.000,Device 1,ip-address010.006.002.124 Netmask255.255.000.000 Gateway000.000.000.000,Device 2,A connection is only possible if the blue numbers are the same,25.05.08,Seite 6,How to Start-up the new components,1. Change the Pc-Ethernet settings,Open the networksetting in your PC,10 . 6 . 2 .

6、 4,To get a connection to the devices Set the ip-address of the pc-ethernet card To a address like 10.6.x.x,Attention: If you connect a Pc direkt to a device you Need a cross-cabel. If the Pc and the devices are connected Over a ethernet switch you need a patch cabel.,25.05.08,Seite 7,How to Start-u

7、p the new components,1. Change the Pc-Ethernet settings,Put in the ip-address Of the DiG000,Open javacanmon,press the Add button,25.05.08,Seite 8,How to Start-up the new components,1. Change the Pc-Ethernet settings,If you dont know the ethernet address you have to set or read the ip-address 1. With

8、 a seriell connection 2. with Javacanmon Can-Dongle. recommended,25.05.08,Seite 9,How to Start-up the new components,1. Change the Pc-Ethernet settings,Change to service, Select the Service function Set TcpIp Addr and Press the button Set,25.05.08,Seite 10,How to Start-up the new components,1. Chang

9、e the Pc-Ethernet settings,Connect the hardware to the PC.,Ethernet (Cross cabel) z.B. 328927 (10m),25.05.08,Seite 11,How to Start-up the new components,1. Change the Pc-Ethernet settings,Here you see the Active connection To the hardware,25.05.08,Seite 12,How to Start-up the new components,2. Downl

10、oad software to the DIG000 or DM4000,Basicsoftware: PC0016-8008M_ZB,Basis MasterLogic: PC0016-8003M_ZD,Ehternet/IP: PC0016-8002M_ZC,Press the Download button,Change to Software,25.05.08,Seite 13,How to Start-up the new components,2. Download software to the DIG000 or DM4000,Select the software and p

11、ress open,Download is only Possible over Ethernet,25.05.08,Seite 14,How to Start-up the new components,3. Set the Ip-address of the OP1000 Panel,If you press with your fingers at the same time these points for At least 2s. The panel switch to the setup mode,25.05.08,Seite 15,How to Start-up the new

12、components,Change with the keyboard to the function CONFIG and press ENTER,The panel switch to the configuration mode,3. Set the ip-address of the Panel,ENTER,25.05.08,Seite 16,How to Start-up the new components,3. Set the ip-address of the Panel,In the configuration mode You can see some informatio

13、ns.,Firmware,Networksettings,Timesettings,keyboard,25.05.08,Seite 17,How to Start-up the new components,3. Set the ip-address of the Panel,In the configuration mode You can see some informations.,To change the Networksettings Touch this area.,25.05.08,Seite 18,How to Start-up the new components,3. S

14、et the ip-address of the Panel,Set the new ip-Address And press Enter Set the netmask and press Enter Set the Gateway and press Enter Press 2 time Enter and the New settings change.,25.05.08,Seite 19,How to Start-up the new components,3. Set the ip-address of the Panel,Connect the OP1000 to the PC.,

15、Ethernet (Cross cabel) z.B. 328927 (10m),25.05.08,Seite 20,How to Start-up the new components,You need the software UniDataexchanger from exor. Each application need a special panelsoftware named Project.rom,Select Download Project,Select the Firmeware,4. Download software to the panel,25.05.08,Seit

16、e 21,How to Start-up the new components,4. Download software to the panel,Open the option Communication To select the ip-address Of the panel,25.05.08,Seite 22,How to Start-up the new components,Select the OP1000,Here you have to be set the ip-address of the Panel. The Panel must connected to the PC

17、,You also can try the Button Pick UniOP. All connected Panels are showed and you Can select the needed panel,If no panel is showed in the Pick UniOP you have no connection,4. Download software to the panel,25.05.08,Seite 23,How to Start-up the new components,Befor you can download a programm the pan

18、el have to be switched to the configuration mode.,Select Commands Switch to configuation mode, And wait until done.,The panel shows a black screen with several Settings of the panel. After that you can start with The download of the software.,4. Download software to the panel,25.05.08,Seite 24,How t

19、o Start-up the new components,Press the Start button and select the application.rom file. After Open the download starts,4. Download software to the panel,25.05.08,Seite 25,How to Start-up the new components,You see the state of the download,4. Download software to the panel,25.05.08,Seite 26,How to

20、 Start-up the new components,After successful download you have to switch the panal back to the operation mode. You also can switch off the power supply of the panel.,4. Download software to the panel,25.05.08,Seite 27,How to Start-up the new components,4. Download software to the panel,The panel is

21、 only running if you have a masterLogic software in a DIG000 or a DM4000 and is connected to a MasterLogic,Startwindow if Not connected,25.05.08,Seite 28,Basicsoftware: PC0016-8008M_ZC,Basis MasterLogic: PC0016-8003M_ZD,Ehternet/IP: PC0016-8002M_ZC,Infos about the software of the masterLogic software,How to Start-up the new components,5. Download masterLogic-software to the DIG000,Select the PLC bar,25.05.08,Seite 29,application S

温馨提示

  • 1. 本站所有资源如无特殊说明,都需要本地电脑安装OFFICE2007和PDF阅读器。图纸软件为CAD,CAXA,PROE,UG,SolidWorks等.压缩文件请下载最新的WinRAR软件解压。
  • 2. 本站的文档不包含任何第三方提供的附件图纸等,如果需要附件,请联系上传者。文件的所有权益归上传用户所有。
  • 3. 本站RAR压缩包中若带图纸,网页内容里面会有图纸预览,若没有图纸预览就没有图纸。
  • 4. 未经权益所有人同意不得将文件中的内容挪作商业或盈利用途。
  • 5. 人人文库网仅提供信息存储空间,仅对用户上传内容的表现方式做保护处理,对用户上传分享的文档内容本身不做任何修改或编辑,并不能对任何下载内容负责。
  • 6. 下载文件中如有侵权或不适当内容,请与我们联系,我们立即纠正。
  • 7. 本站不保证下载资源的准确性、安全性和完整性, 同时也不承担用户因使用这些下载资源对自己和他人造成任何形式的伤害或损失。

评论

0/150

提交评论