Heat PumpsHeat pumps operate on the refrigeration cycle (more precisely, on the vapor-compression refrigeration cycle). A schematic of the refrigeration cycle is shown.Refrigeration Cycle.Just like the Rankine steam-cycle, the refrigeration cycle has a boiler (though it is now called an evaporator), a condenser, a pumping (or compression) process, and an expansion process. The following table shows the similarities and differences between the two cycles. Rankine Cycle.ProcessRankine CycleRefrigeration CycleCompressionStep 3-4. Water (in liquid phase) pumped from low to high pressure. Little change in temperature. Work is done on the working fluid.Step 4-1.Vapor (ie, working fluid as vapor) compressed from low to high pressure. There is a significant increase in the temperature of the working fluid. (Note the difference.) Work is done on the working fluid. Note: per unit of mass compressed, it takes a lot more work to compress a vapour than a liquid.Boiling/EvaporationStep 4-1. The water is heated and converted to steam. Heat (QH) at high temp (TH) is added to the working fluid.Heat flows from the hot space into the working fluid.Step 3-4.The working fluid (as a mixture of liquid and vapor) is heated and converted to totally vapor.Heat (QC) at low temperature (TC) is added to the working fluid. Note the key difference. Heat is flowing from the cold space into the working fluid.ExpansionStep 1-2.The high pressure, high temperature steam expands through the turbine, changing to low pressure, low temperature steam (or to mixture of steam and liquid water).Work is done, that is, there is an output of work.Step 2-3.Condensed (liquid) working fluid expands from high pressure and high Temperature. The expansion occurs across a valve. The result is a mixture of liquid and vapor working fluid at low pressure and low temperature.No work is involved.Note the lack of work. This is a key difference.CondensationStep 2-3.Heat (QC) at low temperature (TC) is rejected from the working fluid. The heat is carried away by the coolant - eg, sea water or cold water routed to a cooling tower.The result is liquid working fluid at low pressure and temperature. Step 1-2.Heat (QH) at high temperature (TH) is rejected from the working fluid.The result is liquid refrigerant at high pressure and relatively high temperature.Note the key difference. Heat is flowing from the working fluid to the warm space (for example, the kitchen).The Rankine cycle is shown in Fig. 3.3. Marching around the cycle: 1(pump) 2(boiler) 3(turbine) 4(condenser).To march around the refrigeration cycle, we refer to Fig. 5.13. The process is:1(expansion) 2(evaporation) 3(compression) 4(condensation).Note the pumping and expansion steps are exchanged in the two cycles. Note, heat is always added in the boiling/evaporation step, and heat is always rejected in the condensation step. However, the relative temperatures are exchanged. In the Rankine cycle, heat is added at high temperature and rejected at low temperature. In the refrigeration cycle, heat is added at low temperature and rejected at high temperature.H2O does not have the properties needed of the working fluid in the refrigeration cycle. Ammonia, Freon, and the new refrigerants with H added to Freon-type molecules are used. The heat pump works by the refrigeration cycle. In cooling mode, that is, in air conditioning mode, the cool space is the built environment and the warm space is the outdoors. In heating mode, the cool space is the outdoors (or the ground) and the warm space is the built environment.In cooling mode, we march around the cycle as follows (hx = heat exchanger):1(expan valve) 2(indoor hx) 3(compressor) 4(outdoor hx).In heating mode, we march around the cycle as follows:1(expan valve) 2(outdoor hx) 3(compressor) 4(indoor hx).In order to handle both modes, a switching system is used to send the working fluid (ie, the refrigerant) to the correct heat exchanger following the valve and compressor. Some of the new heat pumps use the ground as the cool space. That is, the coils of the outdoor heat exchanger are buried (or fluid pumped from underground is used as QC). In heating mode, QH = Qground + W. In cooling mode, the coolth of the ground may be directly used to cool the interior space, saving electricity. Resistance heating coils are also added. These are placed in the stream of air blown through the heat pump hx to the interior space. These coils only kick in when the heat pump cannot keep up with the heat demand. (ME Professor John Kramlich saved considerable electricity by maintaining a slightly higher thermostat setting on his heat pump on cold winter nights. The resistance coils, which gobble up a lot of electricity, didnt kick in when the thermostat was moved to the daytime temperature setting in the morning.)The efficiency of the heat pump is called the coefficient of performance, or COP:COP = energy we want/ energy we pay forCOPcooling mode = heat pulled out of cool space/ electrical energy for running compressorCOPcooling mode = QC/ WCOPheating mode = heat put into warm space/ electrical energy for running compressorCOPheating mode = QH/ W = (QC+W)/ WFor a real heat pump, W includes the electrical energy required to run the heat exchanger blowers (which is fairly small) and the resistance heater.If a heat pump could create no net increase in the disorder of the universe, the COPs would be:COPcooling mode = QC/ W = QC/ (QH QC) = 1/ (TH/ Tc 1)COPhea

温馨提示

  • 1. 本站所有资源如无特殊说明,都需要本地电脑安装OFFICE2007和PDF阅读器。图纸软件为CAD,CAXA,PROE,UG,SolidWorks等.压缩文件请下载最新的WinRAR软件解压。
  • 2. 本站的文档不包含任何第三方提供的附件图纸等,如果需要附件,请联系上传者。文件的所有权益归上传用户所有。
  • 3. 本站RAR压缩包中若带图纸,网页内容里面会有图纸预览,若没有图纸预览就没有图纸。
  • 4. 未经权益所有人同意不得将文件中的内容挪作商业或盈利用途。
  • 5. 人人文库网仅提供信息存储空间,仅对用户上传内容的表现方式做保护处理,对用户上传分享的文档内容本身不做任何修改或编辑,并不能对任何下载内容负责。
  • 6. 下载文件中如有侵权或不适当内容,请与我们联系,我们立即纠正。
  • 7. 本站不保证下载资源的准确性、安全性和完整性, 同时也不承担用户因使用这些下载资源对自己和他人造成任何形式的伤害或损失。

评论

0/150

提交评论