版权说明:本文档由用户提供并上传,收益归属内容提供方,若内容存在侵权,请进行举报或认领
文档简介
CutesCorporationCT-2000SSeries
IGBTINVERTER
Instruction
Introduction/TableofContents
Introduction
ThankyouforchoosingtheCT-2000Sinverterunit,thisinverterunitissuitableforoperatingsquirrelcageinductionmotors.Pleasereadthisinstructionmanualcarefullybeforeactualusageinordertoensureproperoperationandsuityourneeds.
TableofContents
1.Inspectionuponreceiving………………….22.InstallationandStorage……………………2A.InstallationandStorage…………………2
B.Outlinedimension……….33.Applicationnotes……………44.BlockdiagramandWiring…………………4
A.Wiringofmainandcontrolcircuit……4B.Signalcircuit…………….4C.ConnectingthepowersupplyandtheACmotor……5D.R.T.forPowersourcereactor…………5E.Standardexternalconnectiondiagram………………..5F.Controlcircuitspecification…………..…6G.Terminalspecifications…………………7
5.OperationTest……………….96.FunctionSetupandSpecification………..11
A.Keypadoperation………11B.FunctionCode………….12
7.Descriptionofalarmdisplayindications…………………248.Troubleshooting…………….259.MaintenanceandInspection………………2610.StandardSpecification…………………….2711.FunctioncodeTable……….28
-3-
CT2000EInstructionManual
1.Inspectionuponreceiving
A.Checkthatthemodel,thecapacityandpowervoltagespecificationsareasordered.
B.Checkthatnodamagehasoccurredduringtransportation.
C.Checkthatnoneoftheinternalpartshavebeendamagedorhavefallenoff.
D.Checkthatnoneoftheconnectorshavebeendamagedorhavefallenoff.
E.Checkthatthereisnolooseningoftheterminalsorscrewsofeachoftheparts.
2.InstallationandStorage
A.InstallationandStorage:
Iftheequipmentisnottobeinstalledimmediately,itshouldbestoredinacleananddrylocationatambienttemperaturesfrom20℃to55℃.
Thesurroundingairmustbefreeofcorrosivecontaminants.Placeswheretheperipheraltemperatureisfrom-10℃to40℃,and
wheretherelativehumidityis90%orless.Avoidinstallingatplaceswherethereisdust,ironparticles,corrosivegas,waterspray,directsunlightortoomuchvibration.Andplaceswherehasgoodventilation.
4
Installationandstorage
C.Outlinedimension:(mm)
RUN STOPFWD
CC REV10V
Vout RUN/PROG/ UP/IN1 STOPSHIFTEnterRESETCC
DI3 ESCDI2
DI3FRCOM
FAN
CUTES
-5-
Applicationnotes/Blockdiagram,wiring
3.Applicationnotes
A.Concerningtheinverterunit:
(1)Donotfitcapacitorstotheoutputsideoftheinverterinordertoimprovethepowerratio.
(2)IncaseoffittingMCbetweeninverterandmotortocontrolmotoroperation,thenthecapacityofinvertermustbe6timesthecapacityofmotor.
(3)Runamotorthatiswithinthecapacityoftheinverterunit,lightloadcurrentandno-loadcurrentwillcausethemotortodevelopripplecurrent.
B.ConcerningtheACmotor
(1)Whengeneral-purposemotorsareoperatedatlowspeeds,thereisareducedcoolingeffect,pleaseapplythespecialpurposemotor.
(2)Operationatfrequenciesexceeding60Hzrequirescautionasthereisthedangerofthemechanicalstrengthfailureofthemotor.
(3)Whenmotorswithbrakesarebeingoperated,thepowerforthebrakeandinvertershouldbetakenfromthesamepowersupplyandthebrakeoperationmustbeinphasewhentheunitisstartedandstopped.
4.Blockdiagram,Wiring
A.Wiringofmainandcontrolcircuit
Wireaccordingtothestandardconnectiondiagram.Onusingtheexternalsequencecontrol,pleaseusesmallsignalrelayordoubleterminalrelaytoavoidrelayterminalmalfunction.
B.Signalcircuit
Thesignalcircuituseseithershieldedpairsortwistedpairs,shouldbewiredeitherusingawiringductseparatedfromthatforthepowercircuit,orwiththewiringconduitisolatedasmuchaspossible.
-6-
Blockdiagram,wiring
C.ConnectingthepowersupplyandtheACmotor
Connectthemaincircuit,bywiringaccordingtothemaincircuitterminalconnectiondiagram.Careisrequirednottomakeamistakewhenconnectingtheinputandoutputterminals,lestitwillcauseinverterdamage.SpecificationsofmaincircuitpathandNFBareasfollow:
Voltage(V)
220
Model
CT-2002S-A40
CT-2002S-A75
NFB(A) Wiresizeforcircuit(mm2)
10 2.0
10 2.0
D.instantaneouscurrentandtoimprovepowerratio,itshouldbefittedtheA.C.L.toR.T.inputsideunderthefollowingcircumstance:
a.Wherepowersupplycapacityislargerthan500KVA.
b.Usingthyrister,phaseadvancecapacitoretc.fromthesamepowersupply.
A.C.L.Specificationstable:
Voltage(V)
220
Model
CT-2002S-A40
CT-2002S-A75
Current(Ar.m.s)6A
6A
InductionValue1.8mH
1.8mH
-7-
Blockdiagram,wiring
F. StandardExternalConnectionDiagram
-8-
Blockdiagram,wiring
G.Controlcircuit
-9-
Blockdiagram,wiring
H.TerminalSpecifications
Main
Circuit
R.T.ACpowerinput 1∮ACpower200-230V/50,60Hz
terminal
U.V.WInverteroutput 3-phaseinductionmotorterminal
ControlTerminal
(1)
E Groundterminal10V Powerspeedoutput
setting
IN1 Currentspeedinput
setting
LocatedonscrewsofexternalheatsinkDC10V
DC0~10
VOUTOperationFrequencyAnalogOutput0~10VDC
ControlTerminal
(2)
outputindicationCC Commoninput
controlterminalCOMSequencecontrol
commonterminalFR Forwardoperation
inputterminal
DI1
Groundterminalforspeedsetting
Groundterminalforsequencecontrol
ForwardoperationbyFR-COMshorted
DI2 ControlinputterminalSetfunctionbyCd40、Cd41andCd42DI3
-10-
AdjustandFunctionSpecification
5.OperationalTestA.Checkbeforetest
Pleasecheckthefollowing:
(1)Iswiringcorrect?Checkespeciallytheinputandoutputterminals.(2)Isthereashort-circuitorgroundconnectiononexternalwiring?(3)Makesurethereisnolooseningofscrews.
(4)Checkexternalsequencecontrolcircuit.(5)Checkvoltageofpowersupply.
B.OperationMethod
CT-2000Sseriesinverterunithasbothoperatorpanelandexternaloperationmethods.
(1)Operatorpanel
(2)Externalsignaloperation
-11-
OperationalTest
C.Operationaltest
Testaccordingtothefollowingprocedureandbeawareofindications.(1)Basicoperationaltest
-Operationalprocedure
I. Connectpowersupply
II.Monitorglitteringindicatesfrequency
III.PressRunkey,motorstartsrunning.Itwillstopacceleratingafterreachingsetfrequency
IV.AfterpressingSTOPkey,motorstopsandindicatingfrequencystepsdown.Thesetfrequencystartsglitteringafterthemotorstops.
-Operationmonitordisplay
I.Flashdisplayoffrequencydefault(10.0Hz).
II.Displayvaluewillbeincreasedtillreachsettingpointandmaintainthevalue.
III.Displayvaluewillfollowoperationalfrequencydecreasingdowntozerowhenrevolutioncompletelystopped.
(2)Frequencychangetest-Operationalprocedure
I. ExercisetheaboveoperationtestproceduresI,II,IIIII.ChangingfrequencycommandbyCd00
III.RepeatproceduresIItoincreaseordecreasefrequency-Operationmonitordisplay
I. ThesameastheabovebasictestofI,II
II.MonitordisplayindicatesthecurrentnewsettingvalueNote:
1.Ismotoroperationdirectioncorrect?(ChanginganytwoofU.V.Woutputterminalstochangemotoroperationdirection)
2.Isthereanynoiseorvibrationonmotor?
3.Isitrunsmoothlyduringaccelerationanddeceleration?4.Isthereanypowerfailure?
-12-
AdjustandFunctionSpecification
1.AdjustandFunctionSpecificationA.Keypadoperation
Display:
1. RUN:inverterinrunning
2. FWD:motoroperateatforwarddirection3. REV:motoroperateatreversedirection4. STOP:inverterinstop
Key:
A.RUN/STOP:RUN-Instopordecelerationmotion,pressisRUNSTOP-Inuniformoraccelerationmotion,pressisSTOP
B.PROG/►,ENTER,▲:RefertonextpageC.RESET:clearerrorstate
-13-
OperationalTest
Externalcontrolterminalstatus
E 0
Displaymode
IGBTtemperature H18.7
OutputVoltage A220
PressCommandfrequency 10.0 ▲
DCBusVoltage d310
Runningfrequency 10.0
Press“Enter”
Cd00 10.0
Displaymode
Press”PROG”
Cd
Press”Enter”keythensavesettingvalue
Cd00Press
“Enter” 10.0
Press
010.0
Press▲ 110.0
Press“PROG”keytwosecondor
“PROG”and“▲”key
CE
CE00Press
“Enter” PL.U
Dark Flash
-14-
AdjustandFunctionSpecification
B.FunctionCode
§Cd00Setfrequency(settablerange0.5-240HZ)
frequencycommandwhenCd-01=0
Note:SetvalueshouldbeinaccordancewithV/Fslope(Cd05)andupperlimitfrequency(Cd17).
§Cd01Settingprocedureoffrequency(Selectiverange0-1)Thefunctioncannotbemodifiedduringrevolution.
Settingprocedureoffrequencyistoselecteitherpanelkeyorexternalanalogsignal.
Cd01=0 OperationpanelCd00
Cd01=1 SetfrequencybyterminalIn1DC0-10V/5KΩVR
§Cd02SelectMainmonitordisplay(Selectiverange0-5)
Themonitorisconsistedoffour6-segmentLEDs,displaysfrequencyandvariousdatabydigitalnumberandcharacter.
Cd02=0 Displaythefrequency
Cd02=1 DisplayvoltageofDCBUSCd02=2 DisplayFrequencyHzCd02=3 DisplayrmsofACoutput
Cd02=4 DisplaytemperatureofmoduleCd02=5 Displayexternalcontrolterminalstatus
§Cd03Operationcommandmode(Selectiverange0-1)Thefunctioncannotbemodifiedduringrevolution.Cd03=0 Operationonoperationpanel
Cd03=1 Operationbyexternalterminal,
§Cd04SetV/Fpattern(Selectiverange1-11)
Thefunctioncannotbemodifiedduringrevolution.Thereare4patternsofV/Fslope,asfollow:
-15-
OperationalTest
WhenCd04=0,V/FslopeisdeterminedbyCd32,Cd33.
§Cd05TorquecompensationVb(Settablerange0.0-15.0)Thefunctioncannotbemodifiedduringrevolution.
Thisfunctionistoraiseoutputvoltagetoincreasetorqueofmotor.
Itcanalsobeusedtoincreaseloadslopeoflowvoltageproducedbylongwiringbetweeninverterandmotor,aswellasfluid,fanandpump.
OutputVoltage
100%
50%
VB
15%
FS0% OutputFrequency(HZ)
§Cd06,07,08,09Acceleration/decelerationtime(Settablerange0.1-600.0)
Thetimeneededforsetfrequencyfrom0Hzto50Hz.
Thereare2selectionsforeachofaccelerationtimeanddecelerationtime.Tosetacceleration/decelerationtime
SetValue(T)=(50-0)/△F×T1
T1:timeneededforaccelerate/decelerate△F:frequencychanged
Ex.:Frequencyfrom50Hzdownto30Hz,neededtime1sec.Then:SetValue(T)=50/50-30×1=2.5
Cd06=1stAccelerationtimeCd07=1stDecelerationtimeCd08=2ndAccelerationtimeCd09=2ndDecelerationtime
Note:The2ndacceleration/decelerationtime,needtosetexternalcontrolterminal2ACCand2DCC(e.g.Cd40,Cd41,Cd42)
§Cd10,11,12 Speedsetting(Settablerange0.5-240)Thisfunctionhas4kindsofspeedsetting
-16-
AdjustandFunctionSpecification
The2nd,3rd,4thspeedsaresetfromexternalterminalFRwhichaccommodateterminalDI1,DI2,DI3,thesettingvaluecannotexceedtheallowedrange.
Cd10=2ndspeedsettingCd11=3rdspeedsettingCd12=4thspeedsetting
Cd-00 2nd 3rd 4th
without ○ ╳ ╳ ╳2DF ╳ ○ ╳ ╳3DF ╳ ╳ ○ ╳
2DF+3DF ╳ ╳ ╳ ○
Note:
Whenapplytomulti-speedsetting,useexternalcontrolDI(e.g.Cd40,Cd41,Cd42)topre-set2DF3DFandusepaneltopre-inputtosetfrequency.
§Cd13Joggingfrequency(Settablerange0.5-30.0)
Tocontroljogging,useexternalterminalDI(Cd40,Cd41,Cd42)FRorRRwithCOMshorted.
Setrunningdirection
FRorRR
2
Runningmode:Jogging
Forward(Reverse)
Note:FirstputinJOG,andthenFR(orRR).
-17-
OperationalTest
BesurealwaystoputinJOGbeforeFR(orRR).
§Cd14Startfrequency(Settablerange0.5-30.0)Setmotorstartfrequency
Settablerangeoffrequencyis0.5Hzto30.0Hz,accuracyis0.1Hz.Frequency
StartFrequency
Time
Note:Themostappropriaterangeforstartfrequencyis0.5Hzto10Hz.
§Cd15Upperlimiteroffrequency(Selectiverange10-240)
ThislimiterisusedtooperatewithinupperlimitfrequencyofmotorAvoidinputerrorscausedbythepanelkeysandresultinmechanicaldamage.
§Cd16Lowerlimiteroffrequency(Settablerange0.5-100)
Thislimiterisusedtooperatewithinlowerlimitfrequencyofmotor
Output FHFrequency
UpperLimiter
LowerLimiter
SetFrequencyOperation
§Cd17Acceleration/decelerationtimeofjogging(Settingrange0.10-30.00)
Timeneededforsetfrequencyfrom0Hzto50Hz.SetValue(T)=(50-0)/△F×T1
T1:Timeneededforacceleration/deceleration△F:Frequencychanged
-18-
AdjustandFunctionSpecification
§Cd18 Brakingmode(Settablerange0-3)
ThisfunctionmustaccommodateCd19,Cd20,Cd21.Cd18=0NoDCbraking
Cd18=1StopmodeCd18=2Startmode
Cd18=3Stopandstartmode
§Cd19DCbrakingfrequency(Settablerange1-10)ThisfunctionmustaccommodateCd18,Cd20,Cd21.
SetfrequencyofDCbrakestartsatthetimeofinverterdecelerationstops,theDCbrakeisactivewhenoperatesbelowthestartingfrequency.
§Cd20DCbrakingvoltage(Settablerange1-15)
ThisfunctionmustaccommodateCd18,CD19,Cd21.DCbrakingtorquesetting
WhenDCbrakeisactive,monitordisplays“dCbr”Note:
Highervalue,higheroutputbraketorque.
WhenDCbrakevoltageishigh,beawareofovercurrent.
OutputFrequency
§Cd21DCbrakingtime(Settablerange1-60)AdjustDCbrakingtime
StartFrequency
BrakingFrequency
Time
BrakingVoltage
BrakingRate
TimeBrakingTime
Note:
1.DCbrakingtimetoolongortoomanytimesispossibletocausemotordamagebecauseofoverheat.
-19-
OperationalTest
2.SetCd18=0whenDCbrakingisnotrequired.
§Cd22Motorrunningdirection(Settablerange1-3)
Fixmotorrunningdirectiontopreventmechanicaldamage.
Cd22=1 Bothforwardandrevisedirectionsavailable,Nostoprequired.
Cd22=2Onlyforwardoperationavailable.Cd22=3Onlyreverseoperationavailable.
§Cd23Stopbypanelkey(Settablerange0-1)Cd23=0Nofunction
Cd23=1Withfunction
Stopfunction:Thisfunctionenablestheinvertertobestoppedbypanelkeywhiletheinverterisoperatedbyexternalsequence.
§Cd24Initialfactorysetting(Settablerange0,1)Thefunctioncannotbemodifiedduringrevolution.Setdatatooriginalfactorysetting.
Cd24=0Nochange
Cd24=1Initialfactorysetting,refertofunctioncodetable.Note:
Afterthisfunctionisactive,contentvaluereturnsto“0”,readablevaluealways“0”.
§Cd25Failurerecordclear(Settablerange0,1)ClearthefailurerecordcontentofCE00,01,02,03
Cd36=0Nochange
Cd36=1Allofthecontentsofdatawillbe“nOnE”,displayof“LoAd”aftersetting
Note:Afterthisfunctionisactive,contentvalueautomaticallyreturnsto“0”,thusreadablevaluealways“0”.
§Cd26Analogoutputcalibration(Settablerange90-110)Settheratiooffrequencygraduationcalibration
thenCd26=9999%ofinitialfactoryCd26=101101%ofinitialfactory
§Cd27Frequencygainsetting(Settablerange20-200)Selectratiooffrequencygain
-20-
AdjustandFunctionSpecification
Gainsettingforexternalinputsignalsisavailableusingthisfunction.OutputFrequency=SetValue×FrequencyGain
§Cd28Frequencycommandbias(Settablerange0-250)Externalanalogfrequencycommandbiassetting
FrequencyOutput%
SettableRange
0V
FrequencyCommand
10V
§Cd29Stopmode(Settablerange0,1)Cd29=0Decelerationstop
Cd29=1Freerunstop
§Cd30Datelock(Settablerange0,1)
Tolockdata,preventerrorsbynoneoperator.Cd30=0Datachangecapable
Cd30=1Datachangenotcapable
§Cd31Softwareversion(Readonly)
Thisfunctionistorecordsoftwareversion,readonly.
§Cd32MaximumfrequencysettingFH(Settablerange10-240)Thisfunctioncannotbemodifiedduringrevolution.
WhenCd04=0,themaximumfrequencyV/FslopeFHSettablerange10Hz-240Hz
PleaserefertofunctioncodeCd34.
§Cd33BasefrequencysettingFb(Settablerange10-240)Thisfunctioncannotbemodifiedduringrevolution.
WhenCd04=0,thebasefrequencyV/FslopeFbSettablerange10Hz-240Hz(Fb≦FH)
PleaserefertofunctioncodeCd34.
-21-
OperationalTest
§Cd34V/FfrequencyFC(Settablerange0.5-240)Thisfunctioncannotbemodifiedduringrevolution.
TosetV/FslopefrequencyFCwhenCd04=0.Settablerange10Hz-240Hz(FC≦Fb)
§Cd35PWNfrequency(Settablerange0-7)
Thisfunctioncannotbemodifiedduringrevolution.ThisfunctionistosetPWMfrequency.
ThehigherpitchofPWM&thelowernoiseofmotor,howevermotormightbeshave.
ThelowerpitchofPMM&thehighernoiseofmotor,howevermotorshouldbemorestable.
Cd35 PWMFrequency0SettingbyCd36
1 4KHZ2 6KHZ3 8KHZ410KHZ512KHZ614KHZ716KHZ
§Cd36PWMFrequency(Settablerange15-40)
Thisfunctioncannotbeadjustedduringoperation.ThisfunctionistosetPWMfrequency.
PWM(KHz)=SetValue/10
Ex:Cd36=15,PWNFrequency=1.5KHzEx:Cd36=30,PWNFrequency=3.0KHz
§Cd37Switchpointfor3rdphasePWMand2ndphasePWM(Settablerange15-40)
-22-
AdjustandFunctionSpecification
Thisfunctionisadjustableduringrevolution
Ex.Cd37=5whenoutputvoltageofinverterexceedratedvoltage5%+3%=8%,inverteroutputshiftfrom3rdphasePWMto2ndphasePWM.Whenoutputvoltagelowerthan5%ofratedvoltage,inverteroutputshiftfrom2ndphasePWMto3rdphasePWM.
§Cd38Powersourcepositioningaccuracycalibration(Settablerange0-20)Thisfunctionisadjustableduringrevolution
ThisfunctionistoadjustthecalibrationofvoltagepositioningonDCBUSbetweendetectedandactualposition.ThedisplayvalueofCd02=1willbelowerwhenCd38setatbiggerfigure.Cd02=1displaywillbehigherwhenCd38settingatsmallerfigure.
§Cd39OverVoltagepreventionfunctionactivepoint(Settablerange
130~145)
Thisfunctioncannotbemodifiedduringrevolution
Thisistoadjusttheovervoltageprotectionactivepointwhenovervoltageoccurred.
Note:
activevoltage(VDC)=settingvalue×200V×%×√2Ex:Powersource=200V,setvalue=140,
activevoltage(VDC)=140×200V×%×√2=395.92V
§Cd40,41,42DI1,DI2,DI3externalcontrolterminalsetting(0~13)
SetValue0123456789101112
13
Function2DF3DFNU2ACC2DCCMBSRSTNUJOGUPDOWNNUNU
REW
FunctionInstruction
2DF3DF:multi-speedsetting(cd-10,11,12)
UP: Usingexternalterminalasfrequencyincreasing.
DOWN: Usingexternalterminalasfrequencydecreasing.Min.frequencyissettingofCd14
JOG: Joggingoperation(cd13,cd17)RST: Reset,operatesbothpanelkeyand
externalsignal.
MBS: Freerunstop,operatesbothpanelkeyand
externalsignal.
2ACC: 2ndAccelerationtime(cd-08)2DCC: 2ndDecelerationtime(cd-09)REW:Reverseoperation
NU: Nofunction
-23-
DescriptionofAlarmDisplayIndications
§CE00,01,02,03Failurerecord
Recordcauseoffailure,inordertosolvefailure.Note:
1.CannotrecordfailureErr,Ero,Erc.2.Onlymemorize4records.
3.Cannotrecordinverterstoppedbylowvoltage.
4.ReadonlyCE00,01,02,03ordeleteall(Cd25),cannotputinfailurerecordbyoperator.
-24-
AdjustandFunctionSpecification
7.Descriptionofalarmdisplayindications
Error
indication
Descriptionoffault Itemforinspection Processing
operation
Err Operationerror
ErC ErrorofinternalCPU
WastheunitoperatedasUsethecorrectprocedureindicatedinthemanual
IstherealargeamountofCheckthecontactabsorber.
externalnoise InstallanoisefilterECC ErrorofinternalCPU IstherealargeamountofA. PressRESETkey
externalnoise B.
C.
turnoffthepowerandthenturnonagainPleasecontactus(if
A.andB.isfutile)
OC Overcurrent(200%
ratedcurrent)
Wasthererapidacceleration/decelerationand
variationintheload
Lengthentheaccelerationanddecelerationtimeand
reducetheload
OCS Outputshortcircuitor IsthereashortcircuitforPerformameggercheckfor
grounddetected
OU DClinkovervoltage
theoutputorgroundingforthemotor
Wastherefastdeceleration,orfast
voltage
themotor
Lengthenthedeceleration
time.
OH Overheatingofthe
coolingfandetected
1. Coolingfanstops 1.2. Ambient
temperaturetoohot2.3. Motorbeing
overload 3.
Exchangethecoolingfan
LowertheambienttemperatureChecktheload
conditions
OLOverloaddetectedformorethanoneminute
PLU Powervoltagetoolow
Isthemotorbeingoverloaded
Ispowervoltagetoolow
Increasethecapacityofthe
inverterandmotorImprovepowersupply
condition
-25-
Troubleshooting
8.Troubleshooting
Descriptionoftrouble Possiblecause Solution
Themotordoesnot 1. Wiringerror Refertothewiringdiagram
runatall 1.
2.
Checkthepowerinputwiring
IsthereavoltageforU.V.Woutput
2. Wrongsettingsat
operatorpanel
3. Inverterdisplaysfault
indication
ThefunctionCd03isasfollows
0:Panelkeyoperation
1:Externalsignals
Referto“ProtectFunction”
4. MotorcannotstartdueExchangeahighercapacityone
tooverload
5. Motorbreaksdown
6. Inverterbreaksdown
Repairmotor
Pleasecontactus
“OC”or“OCS”is
indicatedduring
1. ShortcircuitonU.V.WExcludeshortcircuitorgrounding
orgroundingformotor
operation.
(Overcurrent)
“OU”isdisplayed
duringinverter
operation
“OH”isdisplayed
duringinverter
operation
2. Instantaneously
mechanicalloadon
motor
3. Motorbreaksdown
4. Inverterbreaksdown
1. Ispowervoltagewith
thespecification
2. Decelerationtimetoo
short,unabletobe
loaded
1. Checkifthecooling
fanisstillworking
2. Isambient
temperaturetoohot
Reduceloadorincreaseinvertercapacity
Repairmotor
Pleasecontactus
Improvepowervoltagecondition
tolengthendecelerationtime
Changecoolingfanandcleandirt
Improveambienttemperaturecondition
“OL”isdisplayed Overload Reduceloadorincreaseinvertercapacity
duringinverter
operation
Noanyindication,the1. Powerfailure Checkthecapacityofthepowerfacilities
outputfrequency
displayed“0”
2. IsthereloosenpartonCheckexternalcontrolterminal
externalcontrol
terminal
-26-
MaintenanceandInspection
9.MaintenanceandInspection
Maintenanceandinspectionmustbetakenunderpoweroff.Cautionsonmaintenanceandinspection:
(1)Capacitorischargedathighvoltageforawhileafterturningoffthepower.(Accordingly,starttheinspectionworkatleast5minutesafterturningoffthepower)
(2)Dotheworkwithoperator.
Inspectionitems:
(1)PleasecheckthefollowingitemsA.Motorrunsasexpected.
B.Avoidinstallingoncircumstanceslikeacid,alkaloid.
C.Notroubleisrecognizedinthecoolingsystemandirregularvibrationornoise.
D.Nopartsisoverheatedorburned.(2)Periodicinspection
Interval Inspectionitem
Every6months1.2.
3.
Terminalplatesandmountingbolts.Corrosionandbreaksintheterminalclipsforthewiring.
Conditionfortheconnectorfixing.
Onceayear 1.
2.
Useclean,dryairtoremovedustbuildupfromtheguards,thestackandthecoolingfan.Checkforpartsburnsordamageandmake
anyexchangesnecessary.
-27-
StandardSpecification
10.StandardSpecification200Vseries
Motorrating(KW) 0.4 0.75
Model
Ratedcurrent(A)
Ratedcapacity(KVA)
CT2002S-A402.5
1
CT2002S-A754.2
1.8
Powersupply
Outputvoltage
ControlmethodFrequencyaccuracy
Frequencyresolution
Frequencyrange
V/FratioTorqueboost
Acceleration/DecelerationtimeDCInjectionBraking
Standardfeature
Frequencysetting
OperatingDisplay
ProtectionfunctionAltitude
AmbientTemperature
StorageTemperature
Vibration
Humidity
1∮200~230V±10%50Hz/60Hz±5%3∮220V
SineP.W.Mcontrol
Analogsetting:±0.5%(35℃)Digitalsetting:0.5~240Hz→0.1HzAnalogsetting:(setvalue/1000)Hz0.5~240HZ
4patterns,oranyV/Fpatterns.0~15.0%voltageboost
0.1~600.0sec(linear,two-stepsetting)
DCInjectionBraking(Settingmode,torque,time,activefrequency)
Jogging,upper/lowerfrequencylimit,4-stepspeedsetting,BIAS,frequencyindicatedoutput(DC0~10V),operationdirectionsetting,forward/reverseprohibit,datalock.
Digitalsettingbykeypad,orexternalanalogsignal(DC0~10V)
7-segmentLEDdisplay:Frequency,voltage,settingvalue,function,faultstatus,Temperatureofmodule.
Lowvoltage,overvoltage,overload,overcurrent,overheat.
Altitude1,000morlower,keepfromcorrosivegasses,liquidanddust-10℃~40℃(Non-condensingandnotfrozen)
-20℃~60℃Below0.6G
Relativebetween45﹪to90%(Nocondensing)
Protectivestructure
Weight(Kg)
Convectioncooled
1.9
Forcedair-cooling
1.9
Outlinedimension(LxWxH,cm)16.4x12.9x12(w/cover)
-28-
MaintenanceandInspection
11.FunctionCodeTable
Code Function
No.
DetailofData Initialfactory
setting
Cd00SetfrequencyCd01Frequencysetting
procedureCd02Selectmonitor
displaydata
Cd03Operationcommand
Cd04V/Fpattern
Cd05TorqueboostCd061stacceleration
time
Cd071stdecelerationtime
Cd082ndaccelerationtime
Cd092nddecelerationtime
Cd10No.2frequencyCd11No.3frequencyCd
温馨提示
- 1. 本站所有资源如无特殊说明,都需要本地电脑安装OFFICE2007和PDF阅读器。图纸软件为CAD,CAXA,PROE,UG,SolidWorks等.压缩文件请下载最新的WinRAR软件解压。
- 2. 本站的文档不包含任何第三方提供的附件图纸等,如果需要附件,请联系上传者。文件的所有权益归上传用户所有。
- 3. 本站RAR压缩包中若带图纸,网页内容里面会有图纸预览,若没有图纸预览就没有图纸。
- 4. 未经权益所有人同意不得将文件中的内容挪作商业或盈利用途。
- 5. 人人文库网仅提供信息存储空间,仅对用户上传内容的表现方式做保护处理,对用户上传分享的文档内容本身不做任何修改或编辑,并不能对任何下载内容负责。
- 6. 下载文件中如有侵权或不适当内容,请与我们联系,我们立即纠正。
- 7. 本站不保证下载资源的准确性、安全性和完整性, 同时也不承担用户因使用这些下载资源对自己和他人造成任何形式的伤害或损失。
最新文档
- 太阳能光伏发电合同能源管理协议
- 外贸公司应收账款协议书
- 2024年04月贵州民族大学招考聘用程序招考聘用博士配偶工作笔试历年高频考题难与易错考点摘选后附答案详解
- 2024年04月滇西应用技术大学普洱茶学院急需紧缺人才招考聘用20人笔试历年(难与易错考点)高频考题后附答案详解
- 2024年04月湖南省泸溪县县直机关2024年公开选调14名工作人员笔试历年(难与易错考点)高频考题后附答案详解
- 2024年04月湖北省荆州高新区2024年度公开招考15名社区工作者笔试历年高频考题难与易错考点摘选后附答案详解
- 2024年04月浙江金华永康市发展和改革局工作人员招考聘用笔试历年(难与易错考点)高频考题后附答案详解
- 2024年04月浙江省嘉兴市秀洲区文化和旅游局2024年公开招考1名编外人员笔试历年(难与易错考点)高频考题后附答案详解
- 2024年04月浙江温州乐清市教育系统引进高层次紧缺人才17人笔试历年高频考题难与易错考点摘选后附答案详解
- 2024年04月浙江宁波市鄞州区百丈街道招考聘用编外工作人员笔试历年高频考题难与易错考点摘选后附答案详解
- 夜莺与玫瑰(英汉对照图文典藏版)
- 蔬菜配送服务标书
- 室间质评不合格原因分析及纠正措施表
- 跟我学礼仪(黑龙江农业工程职业学院)【智慧树知到】章节答案
- 广东省最新病历书写规范
- DB37T 997-2022危险化学品作业场所警示标志标识规范
- 自主招生物理试卷
- 医院门诊登记本
- JJF 1102-2003内径表校准规范
- 马尔代夫旅游简介
- GB 20052-2020电力变压器能效限定值及能效等级
评论
0/150
提交评论