ICS
FORMTEXT
29.240.20
FORMTEXT
F20
FORMTEXT
DL
ElectricPowerIndustryStandardofthePeople’sRepublicofChina
DL/T400—2019
ReplaceDL/T400—2010
TechnicalGuideforLiveWorkingin500kVACCompactTransmissionLine
IssueDate:June4,2019
ImplementationDate:October1,2019
IssuedbyNationalEnergyAdministrationofthePeople’sRepublicofChina
Foreword
ThisstandardwasdraftedinaccordancewiththerulesgiveninGB/T1.1—2009Directivesforstandardization—Part1:Structureanddraftingofstandards.
ThisstandardisarevisionofDL/T400—2010TechnicalGuideforLiveWorkingin500kVACCompactTransmissionLine.ComparedwithDL/T400—2010,themainchangesareasfollows:
—thescopeofapplicationhasbeenexpandedtosingle-circuitanddouble-circuit500kVACcompactlinesatanaltitudeof3000mandbelow;
—thetechnicalrequirementsforworkingononepower-offcircuitwhiletheothercircuitislivehavebeenadded.
ThisstandardwasproposedbytheChinaElectricityCouncil.
ThisstandardwaspreparedbytheNationalTechnicalCommitteeofStandardizationforLiveWorking(SAC/TC36).
Maindraftingorganizationsofthisstandard:ChinaElectricPowerResearchInstituteCo.,Ltd,JinhuaPowerSupplyCompanyofStateGridZhejiangElectricPowerCo.,Ltd,StateGridShandongElectricPowerCompany,StateGridJiangsuElectricPowerCo.,Ltd,andStateGridHubeiElectricPowerCo.,Ltd.
Maindraftersofthisstandard:LEIXinglie,FANGYuqun,LIUTing,LIUKai,SUNXiaobin,HANXuechun,SUNXiaofeng,HUANGZhenning,MAJianguo,HUChuan,PENGYong,WANGBin,andQIANLiqun.
ThisstandardreplacesDL/T400—2010afterimplementation.
ThisstandardwasissuedonJanuary9,2011asfirstedition,andthisisthefirstrevisededition.
Duringtheprocessofimplementingthisstandard,relevantopinionsoradvicecanbefedbacktotheStandardizationManagementCenteroftheChinaElectricityCouncil(No.1,Lane2,BaiguangRoad,Beijing,100761).
TechnicalGuideforLiveWorkingin500kVACCompactTransmissionLine
Scope
Thisstandardspecifiesthetechnicalrequirements,enteringorleavingequipotential,andthetest,transportationandstorageoftoolsforliveworkingon500kVACcompacttransmissionlines.
Thisstandardisapplicabletoliveworkingon500kVsingle-circuitanddouble-circuitACcompacttransmissionlinesatanaltitudeof3000mandbelow.
Normativereferences
Thefollowingreferenceddocumentsareindispensablefortheapplicationofthisdocument.Fordatedreferences,onlytheeditioncitedapplies.Forundatedreferences,thelatesteditionofthereferenceddocument(includinganyamendments)applies.
GB/T2900.55ElectrotechnicalTerminology—LiveWorking
GB/T6568ScreenClothesforLiveWorking
GB/T13035LiveWorking—InsulatingRopes
GB13398InsulatingHollowTubesandFoam-FilledTubesandSolidRodsforLiveWorking
GB/T14286LiveWorking—TerminologyforTools,EquipmentandDevices
GB/T18037TechnicalRequirementsandDesignGuideforLiveWorkingTools
GB26859SafetyCodeofElectricPowerIndustry—PartofElectricLines
DL/T409SafetyCodeofElectricPowerIndustry(PartofElectricLines)
DL/T463InsulatorHolderforLiveWorking
DL/T876GuideofInsulationCoordinationforLiveWorking
DL/T878TestGuideoftheInsulatingToolforLiveWorking
DL/T974DepotofToolsforLive-Working
DL/T976PreventiveTestCodeofTools,DevicesandEquipmentforLiveWorking
Termsanddefinitions
Forthepurposesofthisdocument,thetermsanddefinitionsgiveninGB/T2900.55andGB/T14286aswellasthefollowingapply.
3.1liveworkingwithprotectivegap
liveworkingcarriedoutafterinstallingprotectivegapsintheadjacenttowersoftheworklocationtolimitovervoltageintheworklocation
Generalrequirements
4.1Personnelrequirements
4.1.1Liveworkingworkersshallbeingoodhealthandfreefromphysicalandpsychologicalobstaclesthathinderwork.
4.1.2Theliveworkingworkersshallhaveabasicknowledgeofelectricalprinciples,masterthebasicprinciplesandoperatingmethodsofliveworking,andbefamiliarwiththeapplicationscopeandusingmethodsofworkingtools.Theyshallmasteremergencyrescuemethods,especiallytheelectricshockrescue.
4.1.3Theliveworkingworkersshallreceivededicatedtraining,passrelevantexaminationsandholdrelevantcertificates.
4.1.4Thepersoninchargeofthework(ortheguardian)shallhaveatleast3yearsofactualworkingexperienceinliveworkingonpowertransmissionlineswithavoltageclassof500kVandabove,befamiliarwithequipmentconditions,andhavecertainorganizationalcapabilityandaccidenthandlingability.
4.2Institutionalrequirements
AccordingtotheprovisionsofandtherelevantinstitutionsofGB26859andDL409.
4.3Meteorologicalrequirements
4.3.1Liveworkingshallbecarriedoutingoodweather.Incaseofthunder,rain,snowandfog,liveworkingshallnotbecarriedout.Whenthewindforceisgreaterthanlevel5(10m/s),liveworkingshouldnotbecarriedoutbetweenphases.
4.3.2Ifliveworkingisrequiredinweatherwithrelativehumiditygreaterthan80%,insulatingtoolswithmoisture-proofperformanceshallbeadopted.
4.3.3Underspecialoremergentconditions,ifemergentlive-linerepairmustbecarriedout,thepersoninchargeoftheworkshallorganizerelevantpersonneltofullydiscussandformulatereliableorganizationalmeasures,safetymeasuresandtechnicalmeasuresaccordingtothesiteclimateandtheworkingconditions,andtheemergentlive-linerepaircanbecarriedoutonlyafterapproval.
4.3.4Incaseofasuddenchangeofweatherduringliveworking,whichmayendangerpersonalorequipmentsafety,theworkshallbestoppedimmediately.Undertheconditionofensuringpersonalsafety,thenormalworkingconditionsoftheequipmentshallberestoredassoonaspossibleorothermeasuresshallbetaken.
4.4Otherrequirements
4.4.1Fornewliveworkingprojectsthataremorecomplicatedandmoredifficultandnewdevelopedtools,scientifictestsshallbeconductedtoconfirmsafetyandreliability,andsafetymeasuresandoperationprocessplansshallbeestablished.Theprojectsandtoolscanbeusedonlyafterapproval.
4.4.2Thepersoninchargeofliveworkingshallcontactthedutydispatcherbeforetheworkstarts,andtheworkcanbestartedonlyaftercontacting.Whenitisnecessarytodisableautomaticreclosingdevices,thelicenseformalitiesshallbeperformed.Aftertheworkisfinished,reportingtothedutydispatchershallbedoneintime.Itisstrictlyprohibitedtostoporresumethereclosingdevicesatanappointedtime.
Technicalrequirements
5.1Maximumovervoltagetimes
Theminimumworkingdistance,theminimumcombinedgapandtheminimumeffectivelengthofinsulatingtoolsforliveworkingon500kVACcompactlinesshallbedeterminedaccordingtothemaximumovervoltagetimesatwork.Themaximumovervoltagetimescanbecalculatedaccordingtothesystemparameters.Iftheexactovervoltagetimesisnotknown,appropriateworkgapsshallbeselectedaccordingtothepossiblemaximumovervoltagetimesofthe500kVsystem[2.18(perunitvalue)].
5.2Groundpotentialworking
5.2.1Whentheworkerworksatgroundpotential,theminimumworkingdistancebetweenthegroundpotentialworkeronthetowerandtheliveconductorsshallnotbelessthantheprovisionsinTable1.
Table1Minimumworkingdistancebetweenthegroundpotentialworkeronthetowerandtheliveconductors(unit:m)
AltitudeH/m
Phase-to-groundmaximumswitchingovervoltagetimes(perunitvalue)
1.80andbelow
Above1.80
H≤1000
3.0
3.2
1000<H≤2000
3.2
3.4
2000<H≤3000
3.4
3.6
Note:Thevaluesinthetabledonotincludethespaceoccupiedbythehumanbody,whichshallnotbelessthan0.5mandshallbeconsideredatwork.
5.2.2TheminimumeffectiveinsulationlengthofinsulatingtoolsshallmeettheprovisionsinTable2.
Table2Minimumeffectiveinsulationlengthofinsulatingtools(unit:m)
AltitudeH/m
Insulatinghandsticks
Insulatingload-bearingtoolsandinsulatingropes
Phase-to-groundmaximumswitchingovervoltagetimes(perunitvalue)
1.80andbelow
Above1.80
1.80andbelow
Above1.80
H≤1000
3.5
3.7
3.2
3.4
1000<H≤2000
3.7
3.9
3.4
3.6
2000<H≤3000
3.9
4.1
3.6
3.8
5.3Barehandworking
5.3.1Whentheworkerentersorleavesequipotentialviainsulatingtools,theminimumcombinedgapshallnotbelessthantheprovisionsinTable3.
Table3Minimumcombinedgapofenteringorleavingequipotential(unit:m)
AltitudeH/m
Phase-to-groundmaximumswitchingovervoltagetimes(perunitvalue)
1.80andbelow
Above1.80
H≤1000
3.2
4.0
1000<H≤2000
3.4
4.2
2000<H≤3000
3.6
4.4
Note:Thevaluesinthetabledonotincludethespaceoccupiedbythehumanbody,whichshallnotbelessthan0.5mandshallbeconsideredatwork.
5.3.2Whentheequipotentialworkerentersorleavesequipotentialalongatensioninsulatorstring,theinsulatorstringshallbetestedfirst.ThenumberofgoodinsulatorsshallnotbelessthantheprovisionsofTable4afterthenumberofinsulatorsshort-circuitedbythehumanbodyandbadinsulatorsisdeductedfromthetensioninsulatorstring.
Table4Theminimumnumberofgoodinsulators
Minimumtotallengthofgoodinsulators/m
AltitudeH/m
Structureheightofeachinsulator/mm
Theminimumnumberofgoodinsulators
3.6
H≤1000
170
22
195
19
205
18
3.8
1000<H≤2000
170
23
195
20
205
19
4.0
2000<H≤3000
170
24
195
21
205
20
5.3.3TheminimumworkingdistancebetweentheequipotentialworkerandtheearthingconductorsshallmeettheprovisionsofTable1.TheminimumeffectiveinsulationlengthofinsulatingtoolsshallmeettheprovisionsofTable2.
5.3.4TheminimumworkingdistancebetweentheequipotentialworkerandtheadjacentliveconductorsshallmeettheprovisionsofTable5.
Table5Minimumworkingdistancebetweentheequipotentialworkerandtheadjacentliveconductors(unit:m)
AltitudeH/m
Phase-to-phasemaximumswitchingovervoltagetimes(perunitvalue)
2.80andbelow
Above2.80
H≤1000
4.6
4.8
1000<H≤2000
4.8
5.0
2000<H≤3000
5.0
5.2
Note:Thevaluesinthetabledonotincludethespaceoccupiedbythehumanbody,whichshallnotbelessthan0.5mandshallbeconsideredatwork.
5.4Workcarriedoutononepower-offcircuitofadouble-circuitlineonthesametowerwiththeothercircuitlive
5.4.1Theworkersarenotallowedtoenterthecrossarmonthelivesideorplaceanythingonthiscrossarmwhenworkingonthetower.
5.4.2Whenthepower-offcircuitpermittedbythedispatcherhasbeenchangedtothemaintenancestate(i.e.,thesubstationgroundingswitchhasbeenclosed),buttheheadendandthetailendofthecircuitarenotgroundedoronlyoneendisgrounded,thispower-offmaintenancecircuitshallstillberegardedasalivecircuit,andtheliveworkingmodeshallbeadoptedforworking.
5.4.3Whenbothendsofthecircuitaregrounded,itcanbeoverhauledbymeansofpower-offmaintenance.Theworkerontheconductorwearsafullsetofconductiveclothing(includingahat,anuppergarment,apairoftrousers,apairofgloves,apairofsocksandapairofshoes,thesamebelow),andthendirectlyentersorleavestheinsulatorstringorconductorofthemaintainedcircuit.Theworkeronthetowerbodymustwearafullsetofconductiveclothingorelectrostaticprotectiveclothingandconductiveshoes.
5.4.4Whenlayingout,withdrawingortighteningaconductoronthepower-offcircuit,measuresshallbetakentopreventtheconductorfromapproachingtheadjacentliveconductorswithinadangerousdistanceduetoswinging(jumping)orotherreasons.
5.4.5Whenoverhaulingandreplacinginsulatorstringsonthepower-offcircuitbymeansofpower-offmaintenance,theworkersshallhangandsetuppersonalsecuritycablesfirstbeforeinstallingthetools(doublehooksandleverhoists)forliftingtheinsulatorstrings.Thehanginganddismantlingmethodsofthepersonalsecuritycablearethesameasthoseofthemaintenanceearthingcable.
5.4.6Therequirementsandsafetyprecautionsforworkingonthegroundwireabovethepower-offcircuitarethesameasthosewhenbothcircuitsarelive.
5.5Workcarriedoutwithprotectivegaps
5.5.1Whentheworkingdistanceorcombinedgapofliveworkingdoesnotmeettherequirements,theworkmodeofinstallingprotectivegapsshallbeadopted.
5.5.2Theearthingcableconnectedtotheprotectivegapsshalladoptthemulti-strandsoftcopperwire,anditscrosssectionshallmeettherequirementsofgroundshortcircuitcapacity,butshallnotbelessthan25mm2.
5.5.3Whentheworkiscarriedoutwithprotectivegaps,theinsulationcoordinationbetweenthevaluesoftheworkingdistance,thecombinedgap,theminimumeffectivelengthofinsulatingtoolsandtheminimumnumberofgoodinsulatorsandthesetvaluesoftheprotectivegapsshallmeettherequirementsofDL/T876.
5.5.4Theworkerwhoinstallsordisassemblestheprotectivegapsshallwearafullsetofconductiveclothing.
5.5.5Beforetheprotectivegapsareinstalled,contactingthedispatchertostopreclosingshallbedone.
5.5.6Theprotectivegapsshallbeinstalledontheadjacenttowerstotheworklocation.Theearthingcableofeachprotectivegapshallbereliablyconnectedwiththemetalcomponentsofthetowerfirst,andthentheotherendshallbehungontheconductorofthemaintainedphase,andthecontactshallbegood.Thedismantlingprocedureisreversed.
5.5.7SeeTable6forthereferencesetvaluesoftheprotectivegaps.Beforetheprotectivegapsareused,thevaluesoftheprotectivegapsmaybecheckedandcorrectedaccordingtotheactualsizeofthetowerhead.
Table6Setvaluesoftheprotectivegaps
AltitudeH/m
Setvaluesoftheprotectivegaps/m
H≤1000
1.2
1000<H≤2000
1.4
2000<H≤3000
1.6
5.5.8Duringinstallation,thedistanceoftheprotectivegapshallbeadjustedtothemaximumvaluefirst,andthenthedistanceshallbeadjustedtothesetvalueoftheprotectivegapwithinsulatingtoolsaftertheprotectivegapisinstalledinplace.Beforetheprotectivegapisdismantled,itsdistanceshallbesetbacktothemaximumvalue,andthenitshallbedismantledaccordingtothedismantlingprocedure.
5.5.9Forthetwoupperphaseconductorsofthethreephaseconductorsarrangedinaninvertedtriangle,theprotectivegapmaybeverticallyinstalledbetweentheconductorandtheframewhichisbetweenthetwohangingpointsoftheV-shapedinsulatorstring,ormaybehorizontallyinstalledbetweenthetowerframeandtheconductor.Intermsofthelowerphaseconductor,theprotectivegapmaybehorizontallyinstalledbetweenthetowerframeandtheconductor.
5.6Safetyprotection
5.6.1Theliveworkingsafetyprotectionequipmentof500kVconventionallinesmaybeusedforliveworkingof500kVcompactlines.
5.6.2TheperformanceoftheconductiveclothingshallcomplywithGB/T6568.
5.6.3Boththeequipotentialworkerandthemid-potentialworkershallwearafullsetofqualifiedconductiveclothing,andflameresistantunderwearshallalsobewornundertheconductiveclothing.
5.6.4Thegroundpotentialworkeronthetowermustwearafullsetofconductiveclothingorelectrostaticprotectiveclothingandconductiveshoesbeforeclimbingthetower.Itisstrictlyprohibitedtowearotherclothesoverconductiveclothingorelectrostaticprotectiveclothing.
5.6.5Theoverheadgroundwireshallberegardedasaliveconductor,andtheworkersshallkeepadistanceofover0.4mfromit.Ifitisnecessarytoworkontheoverheadgroundwire,itshallbegroundedwellthroughdedicatedearthingcables.Themethodsandstepsforinstallingordismantlingthededicatedearthingcablesontheoverheadgroundwirearethesameasthoseforinstallingordismantlingtheearthingcablesonapower-offline.
5.6.6Ifitisnecessarytoentertheoverheadgroundwireformaintenance,theworkingdistanceandmechanicalstrengthoftheworklocationafterbearingconcentratedloadshallbechecked.
5.6.7Whenusinginsulatingropestotransferlargemetalobjects(includingtoolsandmaterials),theworkersonthetoweroronthegroundshallgroundthemetalobjectsbeforetouchingthem.
5.6.8Withregardtolargemetalobjects(e.g.automobiles,etc.)insulatedfromthegroundandplacednearstrongelectricfields,attentionshallbepaidtoprotectingpeoplefrominducedelectricalinjury.Thesemetalobjectsmustbegroundedbeforetheycanbetouched.
5.6Potentialtransfer
5.7.1Theequipotentialworkershallobtainpermissionfromthepersoninchargeoftheworkbeforepotentialtransfer.
5.7.2Whentheequipotentialworkertransferspotential,thedistancebetweenthehumanbodyandtheliveconductorsshallnotbelessthan0.4mItisstrictlyprohibitedtotouchtheliveconductorswithbarehandsorwithbareparts.
5.7.3Duringpotentialtransfer,theactionshallbesmooth,accurateandfast.
Enterorleaveequipotential
6.1Enterorleaveequipotentialonasuspensiontower
6.1.1Theworkershallnotenterorleaveequipotentialfromcrossarmsverticallyoralonginsulatorstrings.
6.1.2Thehangingbasket(hangingchairandhangingladder)method,theinsulatingflexibleladdermethodandothermethodsmaybeusedtoenterorleaveequipotential.
6.1.3Thehangingbaskets(hangingchairsandhangingladders)shallbestablysuspendedbyslings.Thelengthoftheslingsforfixingshallbeaccuratelycalculatedoractuallymeasuredtoensurethattheequipotentialworker’sheadshallnotexceedthegradingringontheconductorside.
6.1.4Themovingspeedofthehangingbaskets(hangingchairsandhangingladders)shallbestrictlycontrolledtoachieveauniformandsteadyspeed.
6.1.5Whenenteringorleavinghighelectricfields,theequipotentialworkershallavoidexcessivebodymovements.Alltheelectricalgapdistances(includingtheworkingdistancesandthecombinedgaps)betweentheequipotentialworkerandtheearthingconductorsandtheliveconductorsshallmeettherequirementsofChapter5.
6.2Enterorleaveequipotentialonatensiontower
6.2.1Theworkermayenterorleaveequipotentialalongtensioninsulatorstringsorviaothermethods.
6.2.2Whentheequipotentialworkermovesalongthetensioninsulatorstrings,thecross-two-short-threemethodshallbegenerallyadopted.Thepositionsoftheworker’shandsandfeetmustbekeptconsistent,andthenumberofinsulatorsshort-circuitedbythehumanbodyandtoolsshallmeettherequirementsofChapter5.
6.2.3Theequipotentialworker’ssafetybeltshallbetiedtotheinsulatorstringheldbytheworker’shandsandshallmovesynchronouslywiththeworker.
6.2.4Whenenteringorleavinghighelectricfields,theequipotentialworkershallavoidexcessivebodymovements.Alltheelectricalgapdistances(includingtheworkingdistancesandthecombinedgaps)betweentheequipotentialworkerandtheearthingconductorsandtheliveconductors,andthenumberofgoodinsulatorsshort-circuitedbythehumanbodyortoolsshallmeettherequirementsofChapter5.
Mattersneedingattentionatwork
7.1Whenliveworkingiscarriedoutonthetowerof500kVACcompacttransmissionlines,aguardianwithspecificresponsibilitymustbearrangedtostayonthetower.Dedicatedcommunicationtoolsshallbeprovidedattheworksitetoensuresmoothcommunicationbetweenworkersonandunderthetower.
7.2Whenthephase-to-groundovervoltageofthelineisgreaterthan1.80(perunitvalue),theequipotentialworkermustadopttheworkmodeofinstallingprotectivegapswhenenteringorleavingequipotentialfromthewindowofthesuspensiontower.
7.3Insulatingtoolsshallbeusedtotransferarticlesbetweentheequipotentialworkerandtheworkeronthetowerframe,andtheeffectivelengthoftheinsulatingtoolsshallmeettherequirementsofTable2.
7.4Theconductiveclothingshallbefreefromdamageandholes,andallpartsofitshallbeconnectedwellandreliably.Incaseofdamageandburrs,itshallbesenttoaqualifiedtestingunittomeasuretheresistance,fusingcurrentandscreeningefficiencyofthewholesetofconductiveclothing,anditcanbeusedonlyafterthemeasurementresultsmeettherequirementsofGB/T6568.
7.5Beforetheinsulatingtoolsareused,aninsulationresistancetester(2500V~5000V)shallbeusedtoconductsegmentedinsulationtests.Theinsulationresistancebetweenevery2cmofmeasuringelectrodesshallnotbelessthan700MΩ.
7.6Theinsulatingtoolsshallbeprotectedfrommoisture,surfacedamageandsurfacedirtwhenused.Theinsulatingtoolsnotinuseshallbeplacedoncleananddrypads.
7.7Whenfounddampened,surface-damagedorsurface-dirty,theinsulatingtoolsshallbehandledintimeandcanbeusedonlyafterpassingthetest.
7.8Beforetheworkstarts,metalscrewrods,holdersandconnectingtoolsusedforliveworkingshallbeassembledontrialandconfirmedtobeflexibleinoperationandreliableinperformance,andshallbeusedcorrectlyaccordingtoon-siteoperationproceduresorworkinstructions.
7.9Themiddlejointofinsulatinghandsticksshallnotbeseparatedandloosenedwhenbearingvariousloadssuchasimpact,push-pullandtorsion,andtheinsulatinghandsticksshallnotbeusedasload-bearingtools.
7.10Inuse,insulatingsupportsticksandinsulatingtensionsticksmustbefixedonthetowerwithdedicatedfixers,anditisstrictlyprohibitedtousethesestickstomoveconductorsdependingonthehumanbody.
7.11Whentheworkissuspendedonthetower,theinsulatinghandsticksshallbehungverticallyorlaidflatonthehorizontaltowermaterials,andshallnotbedraggedonthetowermaterials,soasnottodamagethem.
7.12Whenaninsulatinghandstickisusedonthesuspensiontower,itmaybesuspendedbyaninsulatingropeataproperpositionofthefrontpartofthesticktopreventitfrombeingexcessivelybentandreducethelaborintensityoftheworker.
7.13Thediameterofthemouthofaconductorclampshallbecompatiblewiththeouterdiameteroftheconductor,andsubstitutionisstrictlyprohibitedtopreventtheconductorfrombeingcrushedorslipping.Theradiansofthetwosemicirclesofaclosedinsulatorholdershallbeconsistentwiththeshapeofthesteelcapoftheinsulator,soastoavoidlargestressconcentrationinthestressprocess.Alldouble-wingholdersshallconformtothespecificationsofcorrespondinglinkfittings,andshallbeequippedwithbackupprotectiondevices(suchasclosingbolts)topreventthemfromfallingoff.Crossarmholdersmustadapttothespecificationsofthetowermaterials,andtheassemblyofthemshallbefirm.Thespecificationsoftensionpullersshallbedeterminedaccordingtotheloadandthetensionmode.
7.14Intheworkofreplacingsuspensioninsulatorstringsormovingconductors,whenthesinglesuspensionwiredeviceisused,thereshallbebackupprotectionmeasurestopreventtheconductorsfromfallingoff.
7.15Whenexchangingandtransferringheavytoolsupanddown,thecontrolropeshallbefastenedtopreventthetransferredobjectsfromcollidingwitheachotherandaccidentallycollidingwiththebearingtoolsintheworkingstate.
7.16Insulatingropesshallbekeptcleananddry,andshallbepreventedfromrubbingagainstthetowermaterials.Dampenedinsulatingropesarestrictlyprohibitedtobeusedinliveworking.
7.17Ifzeroandlowresistanceinsulatorsarefoundduringlivetestingofinsulators,theyshallberetested2~3times.
7.18Beforethereplacedinsulatorstringisseparatedfromtheconductor,whenthefirstinsulatornearthecrossarmisdisassembledorinstalled,adedicatedshort-circuitingwiremustbeusedbeforedirectoperation.
7.19Theequipotentialworkermusthavebackupprotectionwhenenteringorleavingequipotentialandworkingatequipotential,andthemid-potentialworkermustalsohavebackupprotectionduringwork.
Testoftools
8.1ThedesignofliveworkingtoolsshallconformtotherequirementsofGB/T18037.Conductiveclothing,insulatingropes,insulatingrods,insulatorholders,etc.,shallpasstypetestsandleavingfactorytestsinaccordancewiththerequirementsofGB/T6568,GB/T13035,GB13398,DL/T463,DL/T878.
8.2ThetoolsshallbesubjectedtoelectricaltestsandmechanicaltestsonaregularbasisaccordingtothetestmethodsofDL/T976.Thetestcyclesareasfollows:
a)electricaltests:preventivetestsshallbeconductedonceayear,andinspectiontestsshallbeconductedonceayear,andtheintervalbetweentwotestsshallbehalfayear.
b)mechanicaltests:preventivetestsshallbeconductedonceayearforinsulatingtoolsandonceeverytwoyearsformetaltools.
8.3Contentsandrequirementsofpreventivetests
a)Powerfrequencywithstandvoltagetest:thetestsampleshallbetestedentirely;theinsulationlengthofthetestsamplebetweenthetestelectrodesshallbe3.7m;thewithstandvoltageshallbe580kV;thetimeshallbe3min.Itisqualifiedifnobreakdown,flashoveroroverheatingoccur.
b)Switchingimpulsewithstandvoltagetest:theinsulationlengthofthetestsamplebetweenthetestelectrodesshallbe3.7m;thestandardswitchingimpulsewave(+250μs/2500μs)shallbeapplied;thevoltageamplitudeshallbe1050kV;thetestsampleshallwithstand15times.Itisqualifiedifnobreakdownorflashoveroccur.
c)Staticloadtest:aloadof1.2timestheweightoftheratedworkingloadshallbeappliedfor1min.Itisqualifiedifnopermanentdeformationordamageoccur.
d)Dynamicloadtest:3timesofac
温馨提示
- 1. 本站所有资源如无特殊说明,都需要本地电脑安装OFFICE2007和PDF阅读器。图纸软件为CAD,CAXA,PROE,UG,SolidWorks等.压缩文件请下载最新的WinRAR软件解压。
- 2. 本站的文档不包含任何第三方提供的附件图纸等,如果需要附件,请联系上传者。文件的所有权益归上传用户所有。
- 3. 本站RAR压缩包中若带图纸,网页内容里面会有图纸预览,若没有图纸预览就没有图纸。
- 4. 未经权益所有人同意不得将文件中的内容挪作商业或盈利用途。
- 5. 人人文库网仅提供信息存储空间,仅对用户上传内容的表现方式做保护处理,对用户上传分享的文档内容本身不做任何修改或编辑,并不能对任何下载内容负责。
- 6. 下载文件中如有侵权或不适当内容,请与我们联系,我们立即纠正。
- 7. 本站不保证下载资源的准确性、安全性和完整性, 同时也不承担用户因使用这些下载资源对自己和他人造成任何形式的伤害或损失。
最新文档
- 2024年05月江苏无锡市惠山区教育局招考聘用技能教师3人笔试历年高频考点(难、易错点)附带答案详解
- 2024年05月应急管理部宣传教育中心第二批次公开招聘2人笔试历年高频考点(难、易错点)附带答案详解
- 2024年05月山西医科大学汾阳学院招考聘用博士研究生5人笔试历年高频考点(难、易错点)附带答案详解
- 2024年05月山东德州市德城区纪委监委引进专业人才3人笔试历年高频考点(难、易错点)附带答案详解
- 2024年05月宁夏石嘴山市第二人民医院招考聘用笔试历年高频考点(难、易错点)附带答案详解
- 2310 天一理财 卷7附有答案
- 普外三病区入职第2年10月份附有答案
- 白化病的症状与护理方法
- 房地产前期部岗位职责(共8篇)
- 卫生系统结构化面试试题及答案
- 2023年高考天津卷化学真题(附带解析)
- 部编版语文五年级下册全册复习课件
- 小艾的端午节 绘本ppt
- 华为客户接待规范-接待礼仪
- 19.1 原子核的组成(共17张PPT).ppt
- APIQ1第九版及产品标准培训20131215解析.ppt
- 工程档案培训会
- 厦门大学军事理论考题(上下场)#考试学习
- 初中英语人教版七年级下册Unit 11 Reading.pptx
- 船舶作业现场危险源辨识及防范措施
- 沥青摊铺合同范本.doc
评论
0/150
提交评论