500kV交流紧凑型输电线路带电作业技术导则-英文版_第1页
500kV交流紧凑型输电线路带电作业技术导则-英文版_第2页
500kV交流紧凑型输电线路带电作业技术导则-英文版_第3页
500kV交流紧凑型输电线路带电作业技术导则-英文版_第4页
500kV交流紧凑型输电线路带电作业技术导则-英文版_第5页
已阅读5页,还剩12页未读 继续免费阅读

下载本文档

版权说明:本文档由用户提供并上传,收益归属内容提供方,若内容存在侵权,请进行举报或认领

文档简介

ICS 

FORMTEXT

29.240.20

FORMTEXT

F20

FORMTEXT

DL

ElectricPowerIndustryStandardofthePeople’sRepublicofChina

DL/T400—2019

ReplaceDL/T400—2010

TechnicalGuideforLiveWorkingin500kVACCompactTransmissionLine

IssueDate:June4,2019

ImplementationDate:October1,2019

IssuedbyNationalEnergyAdministrationofthePeople’sRepublicofChina

Foreword

ThisstandardwasdraftedinaccordancewiththerulesgiveninGB/T1.1—2009Directivesforstandardization—Part1:Structureanddraftingofstandards.

ThisstandardisarevisionofDL/T400—2010TechnicalGuideforLiveWorkingin500kVACCompactTransmissionLine.ComparedwithDL/T400—2010,themainchangesareasfollows:

—thescopeofapplicationhasbeenexpandedtosingle-circuitanddouble-circuit500kVACcompactlinesatanaltitudeof3000mandbelow;

—thetechnicalrequirementsforworkingononepower-offcircuitwhiletheothercircuitislivehavebeenadded.

ThisstandardwasproposedbytheChinaElectricityCouncil.

ThisstandardwaspreparedbytheNationalTechnicalCommitteeofStandardizationforLiveWorking(SAC/TC36).

Maindraftingorganizationsofthisstandard:ChinaElectricPowerResearchInstituteCo.,Ltd,JinhuaPowerSupplyCompanyofStateGridZhejiangElectricPowerCo.,Ltd,StateGridShandongElectricPowerCompany,StateGridJiangsuElectricPowerCo.,Ltd,andStateGridHubeiElectricPowerCo.,Ltd.

Maindraftersofthisstandard:LEIXinglie,FANGYuqun,LIUTing,LIUKai,SUNXiaobin,HANXuechun,SUNXiaofeng,HUANGZhenning,MAJianguo,HUChuan,PENGYong,WANGBin,andQIANLiqun.

ThisstandardreplacesDL/T400—2010afterimplementation.

ThisstandardwasissuedonJanuary9,2011asfirstedition,andthisisthefirstrevisededition.

Duringtheprocessofimplementingthisstandard,relevantopinionsoradvicecanbefedbacktotheStandardizationManagementCenteroftheChinaElectricityCouncil(No.1,Lane2,BaiguangRoad,Beijing,100761).

TechnicalGuideforLiveWorkingin500kVACCompactTransmissionLine

Scope

Thisstandardspecifiesthetechnicalrequirements,enteringorleavingequipotential,andthetest,transportationandstorageoftoolsforliveworkingon500kVACcompacttransmissionlines.

Thisstandardisapplicabletoliveworkingon500kVsingle-circuitanddouble-circuitACcompacttransmissionlinesatanaltitudeof3000mandbelow.

Normativereferences

Thefollowingreferenceddocumentsareindispensablefortheapplicationofthisdocument.Fordatedreferences,onlytheeditioncitedapplies.Forundatedreferences,thelatesteditionofthereferenceddocument(includinganyamendments)applies.

GB/T2900.55ElectrotechnicalTerminology—LiveWorking

GB/T6568ScreenClothesforLiveWorking

GB/T13035LiveWorking—InsulatingRopes

GB13398InsulatingHollowTubesandFoam-FilledTubesandSolidRodsforLiveWorking

GB/T14286LiveWorking—TerminologyforTools,EquipmentandDevices

GB/T18037TechnicalRequirementsandDesignGuideforLiveWorkingTools

GB26859SafetyCodeofElectricPowerIndustry—PartofElectricLines

DL/T409SafetyCodeofElectricPowerIndustry(PartofElectricLines)

DL/T463InsulatorHolderforLiveWorking

DL/T876GuideofInsulationCoordinationforLiveWorking

DL/T878TestGuideoftheInsulatingToolforLiveWorking

DL/T974DepotofToolsforLive-Working

DL/T976PreventiveTestCodeofTools,DevicesandEquipmentforLiveWorking

Termsanddefinitions

Forthepurposesofthisdocument,thetermsanddefinitionsgiveninGB/T2900.55andGB/T14286aswellasthefollowingapply.

3.1liveworkingwithprotectivegap

liveworkingcarriedoutafterinstallingprotectivegapsintheadjacenttowersoftheworklocationtolimitovervoltageintheworklocation

Generalrequirements

4.1Personnelrequirements

4.1.1Liveworkingworkersshallbeingoodhealthandfreefromphysicalandpsychologicalobstaclesthathinderwork.

4.1.2Theliveworkingworkersshallhaveabasicknowledgeofelectricalprinciples,masterthebasicprinciplesandoperatingmethodsofliveworking,andbefamiliarwiththeapplicationscopeandusingmethodsofworkingtools.Theyshallmasteremergencyrescuemethods,especiallytheelectricshockrescue.

4.1.3Theliveworkingworkersshallreceivededicatedtraining,passrelevantexaminationsandholdrelevantcertificates.

4.1.4Thepersoninchargeofthework(ortheguardian)shallhaveatleast3yearsofactualworkingexperienceinliveworkingonpowertransmissionlineswithavoltageclassof500kVandabove,befamiliarwithequipmentconditions,andhavecertainorganizationalcapabilityandaccidenthandlingability.

4.2Institutionalrequirements

AccordingtotheprovisionsofandtherelevantinstitutionsofGB26859andDL409.

4.3Meteorologicalrequirements

4.3.1Liveworkingshallbecarriedoutingoodweather.Incaseofthunder,rain,snowandfog,liveworkingshallnotbecarriedout.Whenthewindforceisgreaterthanlevel5(10m/s),liveworkingshouldnotbecarriedoutbetweenphases.

4.3.2Ifliveworkingisrequiredinweatherwithrelativehumiditygreaterthan80%,insulatingtoolswithmoisture-proofperformanceshallbeadopted.

4.3.3Underspecialoremergentconditions,ifemergentlive-linerepairmustbecarriedout,thepersoninchargeoftheworkshallorganizerelevantpersonneltofullydiscussandformulatereliableorganizationalmeasures,safetymeasuresandtechnicalmeasuresaccordingtothesiteclimateandtheworkingconditions,andtheemergentlive-linerepaircanbecarriedoutonlyafterapproval.

4.3.4Incaseofasuddenchangeofweatherduringliveworking,whichmayendangerpersonalorequipmentsafety,theworkshallbestoppedimmediately.Undertheconditionofensuringpersonalsafety,thenormalworkingconditionsoftheequipmentshallberestoredassoonaspossibleorothermeasuresshallbetaken.

4.4Otherrequirements

4.4.1Fornewliveworkingprojectsthataremorecomplicatedandmoredifficultandnewdevelopedtools,scientifictestsshallbeconductedtoconfirmsafetyandreliability,andsafetymeasuresandoperationprocessplansshallbeestablished.Theprojectsandtoolscanbeusedonlyafterapproval.

4.4.2Thepersoninchargeofliveworkingshallcontactthedutydispatcherbeforetheworkstarts,andtheworkcanbestartedonlyaftercontacting.Whenitisnecessarytodisableautomaticreclosingdevices,thelicenseformalitiesshallbeperformed.Aftertheworkisfinished,reportingtothedutydispatchershallbedoneintime.Itisstrictlyprohibitedtostoporresumethereclosingdevicesatanappointedtime.

Technicalrequirements

5.1Maximumovervoltagetimes

Theminimumworkingdistance,theminimumcombinedgapandtheminimumeffectivelengthofinsulatingtoolsforliveworkingon500kVACcompactlinesshallbedeterminedaccordingtothemaximumovervoltagetimesatwork.Themaximumovervoltagetimescanbecalculatedaccordingtothesystemparameters.Iftheexactovervoltagetimesisnotknown,appropriateworkgapsshallbeselectedaccordingtothepossiblemaximumovervoltagetimesofthe500kVsystem[2.18(perunitvalue)].

5.2Groundpotentialworking

5.2.1Whentheworkerworksatgroundpotential,theminimumworkingdistancebetweenthegroundpotentialworkeronthetowerandtheliveconductorsshallnotbelessthantheprovisionsinTable1.

Table1Minimumworkingdistancebetweenthegroundpotentialworkeronthetowerandtheliveconductors(unit:m)

AltitudeH/m

Phase-to-groundmaximumswitchingovervoltagetimes(perunitvalue)

1.80andbelow

Above1.80

H≤1000

3.0

3.2

1000<H≤2000

3.2

3.4

2000<H≤3000

3.4

3.6

Note:Thevaluesinthetabledonotincludethespaceoccupiedbythehumanbody,whichshallnotbelessthan0.5mandshallbeconsideredatwork.

5.2.2TheminimumeffectiveinsulationlengthofinsulatingtoolsshallmeettheprovisionsinTable2.

Table2Minimumeffectiveinsulationlengthofinsulatingtools(unit:m)

AltitudeH/m

Insulatinghandsticks

Insulatingload-bearingtoolsandinsulatingropes

Phase-to-groundmaximumswitchingovervoltagetimes(perunitvalue)

1.80andbelow

Above1.80

1.80andbelow

Above1.80

H≤1000

3.5

3.7

3.2

3.4

1000<H≤2000

3.7

3.9

3.4

3.6

2000<H≤3000

3.9

4.1

3.6

3.8

5.3Barehandworking

5.3.1Whentheworkerentersorleavesequipotentialviainsulatingtools,theminimumcombinedgapshallnotbelessthantheprovisionsinTable3.

Table3Minimumcombinedgapofenteringorleavingequipotential(unit:m)

AltitudeH/m

Phase-to-groundmaximumswitchingovervoltagetimes(perunitvalue)

1.80andbelow

Above1.80

H≤1000

3.2

4.0

1000<H≤2000

3.4

4.2

2000<H≤3000

3.6

4.4

Note:Thevaluesinthetabledonotincludethespaceoccupiedbythehumanbody,whichshallnotbelessthan0.5mandshallbeconsideredatwork.

5.3.2Whentheequipotentialworkerentersorleavesequipotentialalongatensioninsulatorstring,theinsulatorstringshallbetestedfirst.ThenumberofgoodinsulatorsshallnotbelessthantheprovisionsofTable4afterthenumberofinsulatorsshort-circuitedbythehumanbodyandbadinsulatorsisdeductedfromthetensioninsulatorstring.

Table4Theminimumnumberofgoodinsulators

Minimumtotallengthofgoodinsulators/m

AltitudeH/m

Structureheightofeachinsulator/mm

Theminimumnumberofgoodinsulators

3.6

H≤1000

170

22

195

19

205

18

3.8

1000<H≤2000

170

23

195

20

205

19

4.0

2000<H≤3000

170

24

195

21

205

20

5.3.3TheminimumworkingdistancebetweentheequipotentialworkerandtheearthingconductorsshallmeettheprovisionsofTable1.TheminimumeffectiveinsulationlengthofinsulatingtoolsshallmeettheprovisionsofTable2.

5.3.4TheminimumworkingdistancebetweentheequipotentialworkerandtheadjacentliveconductorsshallmeettheprovisionsofTable5.

Table5Minimumworkingdistancebetweentheequipotentialworkerandtheadjacentliveconductors(unit:m)

AltitudeH/m

Phase-to-phasemaximumswitchingovervoltagetimes(perunitvalue)

2.80andbelow

Above2.80

H≤1000

4.6

4.8

1000<H≤2000

4.8

5.0

2000<H≤3000

5.0

5.2

Note:Thevaluesinthetabledonotincludethespaceoccupiedbythehumanbody,whichshallnotbelessthan0.5mandshallbeconsideredatwork.

5.4Workcarriedoutononepower-offcircuitofadouble-circuitlineonthesametowerwiththeothercircuitlive

5.4.1Theworkersarenotallowedtoenterthecrossarmonthelivesideorplaceanythingonthiscrossarmwhenworkingonthetower.

5.4.2Whenthepower-offcircuitpermittedbythedispatcherhasbeenchangedtothemaintenancestate(i.e.,thesubstationgroundingswitchhasbeenclosed),buttheheadendandthetailendofthecircuitarenotgroundedoronlyoneendisgrounded,thispower-offmaintenancecircuitshallstillberegardedasalivecircuit,andtheliveworkingmodeshallbeadoptedforworking.

5.4.3Whenbothendsofthecircuitaregrounded,itcanbeoverhauledbymeansofpower-offmaintenance.Theworkerontheconductorwearsafullsetofconductiveclothing(includingahat,anuppergarment,apairoftrousers,apairofgloves,apairofsocksandapairofshoes,thesamebelow),andthendirectlyentersorleavestheinsulatorstringorconductorofthemaintainedcircuit.Theworkeronthetowerbodymustwearafullsetofconductiveclothingorelectrostaticprotectiveclothingandconductiveshoes.

5.4.4Whenlayingout,withdrawingortighteningaconductoronthepower-offcircuit,measuresshallbetakentopreventtheconductorfromapproachingtheadjacentliveconductorswithinadangerousdistanceduetoswinging(jumping)orotherreasons.

5.4.5Whenoverhaulingandreplacinginsulatorstringsonthepower-offcircuitbymeansofpower-offmaintenance,theworkersshallhangandsetuppersonalsecuritycablesfirstbeforeinstallingthetools(doublehooksandleverhoists)forliftingtheinsulatorstrings.Thehanginganddismantlingmethodsofthepersonalsecuritycablearethesameasthoseofthemaintenanceearthingcable.

5.4.6Therequirementsandsafetyprecautionsforworkingonthegroundwireabovethepower-offcircuitarethesameasthosewhenbothcircuitsarelive.

5.5Workcarriedoutwithprotectivegaps

5.5.1Whentheworkingdistanceorcombinedgapofliveworkingdoesnotmeettherequirements,theworkmodeofinstallingprotectivegapsshallbeadopted.

5.5.2Theearthingcableconnectedtotheprotectivegapsshalladoptthemulti-strandsoftcopperwire,anditscrosssectionshallmeettherequirementsofgroundshortcircuitcapacity,butshallnotbelessthan25mm2.

5.5.3Whentheworkiscarriedoutwithprotectivegaps,theinsulationcoordinationbetweenthevaluesoftheworkingdistance,thecombinedgap,theminimumeffectivelengthofinsulatingtoolsandtheminimumnumberofgoodinsulatorsandthesetvaluesoftheprotectivegapsshallmeettherequirementsofDL/T876.

5.5.4Theworkerwhoinstallsordisassemblestheprotectivegapsshallwearafullsetofconductiveclothing.

5.5.5Beforetheprotectivegapsareinstalled,contactingthedispatchertostopreclosingshallbedone.

5.5.6Theprotectivegapsshallbeinstalledontheadjacenttowerstotheworklocation.Theearthingcableofeachprotectivegapshallbereliablyconnectedwiththemetalcomponentsofthetowerfirst,andthentheotherendshallbehungontheconductorofthemaintainedphase,andthecontactshallbegood.Thedismantlingprocedureisreversed.

5.5.7SeeTable6forthereferencesetvaluesoftheprotectivegaps.Beforetheprotectivegapsareused,thevaluesoftheprotectivegapsmaybecheckedandcorrectedaccordingtotheactualsizeofthetowerhead.

Table6Setvaluesoftheprotectivegaps

AltitudeH/m

Setvaluesoftheprotectivegaps/m

H≤1000

1.2

1000<H≤2000

1.4

2000<H≤3000

1.6

5.5.8Duringinstallation,thedistanceoftheprotectivegapshallbeadjustedtothemaximumvaluefirst,andthenthedistanceshallbeadjustedtothesetvalueoftheprotectivegapwithinsulatingtoolsaftertheprotectivegapisinstalledinplace.Beforetheprotectivegapisdismantled,itsdistanceshallbesetbacktothemaximumvalue,andthenitshallbedismantledaccordingtothedismantlingprocedure.

5.5.9Forthetwoupperphaseconductorsofthethreephaseconductorsarrangedinaninvertedtriangle,theprotectivegapmaybeverticallyinstalledbetweentheconductorandtheframewhichisbetweenthetwohangingpointsoftheV-shapedinsulatorstring,ormaybehorizontallyinstalledbetweenthetowerframeandtheconductor.Intermsofthelowerphaseconductor,theprotectivegapmaybehorizontallyinstalledbetweenthetowerframeandtheconductor.

5.6Safetyprotection

5.6.1Theliveworkingsafetyprotectionequipmentof500kVconventionallinesmaybeusedforliveworkingof500kVcompactlines.

5.6.2TheperformanceoftheconductiveclothingshallcomplywithGB/T6568.

5.6.3Boththeequipotentialworkerandthemid-potentialworkershallwearafullsetofqualifiedconductiveclothing,andflameresistantunderwearshallalsobewornundertheconductiveclothing.

5.6.4Thegroundpotentialworkeronthetowermustwearafullsetofconductiveclothingorelectrostaticprotectiveclothingandconductiveshoesbeforeclimbingthetower.Itisstrictlyprohibitedtowearotherclothesoverconductiveclothingorelectrostaticprotectiveclothing.

5.6.5Theoverheadgroundwireshallberegardedasaliveconductor,andtheworkersshallkeepadistanceofover0.4mfromit.Ifitisnecessarytoworkontheoverheadgroundwire,itshallbegroundedwellthroughdedicatedearthingcables.Themethodsandstepsforinstallingordismantlingthededicatedearthingcablesontheoverheadgroundwirearethesameasthoseforinstallingordismantlingtheearthingcablesonapower-offline.

5.6.6Ifitisnecessarytoentertheoverheadgroundwireformaintenance,theworkingdistanceandmechanicalstrengthoftheworklocationafterbearingconcentratedloadshallbechecked.

5.6.7Whenusinginsulatingropestotransferlargemetalobjects(includingtoolsandmaterials),theworkersonthetoweroronthegroundshallgroundthemetalobjectsbeforetouchingthem.

5.6.8Withregardtolargemetalobjects(e.g.automobiles,etc.)insulatedfromthegroundandplacednearstrongelectricfields,attentionshallbepaidtoprotectingpeoplefrominducedelectricalinjury.Thesemetalobjectsmustbegroundedbeforetheycanbetouched.

5.6Potentialtransfer

5.7.1Theequipotentialworkershallobtainpermissionfromthepersoninchargeoftheworkbeforepotentialtransfer.

5.7.2Whentheequipotentialworkertransferspotential,thedistancebetweenthehumanbodyandtheliveconductorsshallnotbelessthan0.4mItisstrictlyprohibitedtotouchtheliveconductorswithbarehandsorwithbareparts.

5.7.3Duringpotentialtransfer,theactionshallbesmooth,accurateandfast.

Enterorleaveequipotential

6.1Enterorleaveequipotentialonasuspensiontower

6.1.1Theworkershallnotenterorleaveequipotentialfromcrossarmsverticallyoralonginsulatorstrings.

6.1.2Thehangingbasket(hangingchairandhangingladder)method,theinsulatingflexibleladdermethodandothermethodsmaybeusedtoenterorleaveequipotential.

6.1.3Thehangingbaskets(hangingchairsandhangingladders)shallbestablysuspendedbyslings.Thelengthoftheslingsforfixingshallbeaccuratelycalculatedoractuallymeasuredtoensurethattheequipotentialworker’sheadshallnotexceedthegradingringontheconductorside.

6.1.4Themovingspeedofthehangingbaskets(hangingchairsandhangingladders)shallbestrictlycontrolledtoachieveauniformandsteadyspeed.

6.1.5Whenenteringorleavinghighelectricfields,theequipotentialworkershallavoidexcessivebodymovements.Alltheelectricalgapdistances(includingtheworkingdistancesandthecombinedgaps)betweentheequipotentialworkerandtheearthingconductorsandtheliveconductorsshallmeettherequirementsofChapter5.

6.2Enterorleaveequipotentialonatensiontower

6.2.1Theworkermayenterorleaveequipotentialalongtensioninsulatorstringsorviaothermethods.

6.2.2Whentheequipotentialworkermovesalongthetensioninsulatorstrings,thecross-two-short-threemethodshallbegenerallyadopted.Thepositionsoftheworker’shandsandfeetmustbekeptconsistent,andthenumberofinsulatorsshort-circuitedbythehumanbodyandtoolsshallmeettherequirementsofChapter5.

6.2.3Theequipotentialworker’ssafetybeltshallbetiedtotheinsulatorstringheldbytheworker’shandsandshallmovesynchronouslywiththeworker.

6.2.4Whenenteringorleavinghighelectricfields,theequipotentialworkershallavoidexcessivebodymovements.Alltheelectricalgapdistances(includingtheworkingdistancesandthecombinedgaps)betweentheequipotentialworkerandtheearthingconductorsandtheliveconductors,andthenumberofgoodinsulatorsshort-circuitedbythehumanbodyortoolsshallmeettherequirementsofChapter5.

Mattersneedingattentionatwork

7.1Whenliveworkingiscarriedoutonthetowerof500kVACcompacttransmissionlines,aguardianwithspecificresponsibilitymustbearrangedtostayonthetower.Dedicatedcommunicationtoolsshallbeprovidedattheworksitetoensuresmoothcommunicationbetweenworkersonandunderthetower.

7.2Whenthephase-to-groundovervoltageofthelineisgreaterthan1.80(perunitvalue),theequipotentialworkermustadopttheworkmodeofinstallingprotectivegapswhenenteringorleavingequipotentialfromthewindowofthesuspensiontower.

7.3Insulatingtoolsshallbeusedtotransferarticlesbetweentheequipotentialworkerandtheworkeronthetowerframe,andtheeffectivelengthoftheinsulatingtoolsshallmeettherequirementsofTable2.

7.4Theconductiveclothingshallbefreefromdamageandholes,andallpartsofitshallbeconnectedwellandreliably.Incaseofdamageandburrs,itshallbesenttoaqualifiedtestingunittomeasuretheresistance,fusingcurrentandscreeningefficiencyofthewholesetofconductiveclothing,anditcanbeusedonlyafterthemeasurementresultsmeettherequirementsofGB/T6568.

7.5Beforetheinsulatingtoolsareused,aninsulationresistancetester(2500V~5000V)shallbeusedtoconductsegmentedinsulationtests.Theinsulationresistancebetweenevery2cmofmeasuringelectrodesshallnotbelessthan700MΩ.

7.6Theinsulatingtoolsshallbeprotectedfrommoisture,surfacedamageandsurfacedirtwhenused.Theinsulatingtoolsnotinuseshallbeplacedoncleananddrypads.

7.7Whenfounddampened,surface-damagedorsurface-dirty,theinsulatingtoolsshallbehandledintimeandcanbeusedonlyafterpassingthetest.

7.8Beforetheworkstarts,metalscrewrods,holdersandconnectingtoolsusedforliveworkingshallbeassembledontrialandconfirmedtobeflexibleinoperationandreliableinperformance,andshallbeusedcorrectlyaccordingtoon-siteoperationproceduresorworkinstructions.

7.9Themiddlejointofinsulatinghandsticksshallnotbeseparatedandloosenedwhenbearingvariousloadssuchasimpact,push-pullandtorsion,andtheinsulatinghandsticksshallnotbeusedasload-bearingtools.

7.10Inuse,insulatingsupportsticksandinsulatingtensionsticksmustbefixedonthetowerwithdedicatedfixers,anditisstrictlyprohibitedtousethesestickstomoveconductorsdependingonthehumanbody.

7.11Whentheworkissuspendedonthetower,theinsulatinghandsticksshallbehungverticallyorlaidflatonthehorizontaltowermaterials,andshallnotbedraggedonthetowermaterials,soasnottodamagethem.

7.12Whenaninsulatinghandstickisusedonthesuspensiontower,itmaybesuspendedbyaninsulatingropeataproperpositionofthefrontpartofthesticktopreventitfrombeingexcessivelybentandreducethelaborintensityoftheworker.

7.13Thediameterofthemouthofaconductorclampshallbecompatiblewiththeouterdiameteroftheconductor,andsubstitutionisstrictlyprohibitedtopreventtheconductorfrombeingcrushedorslipping.Theradiansofthetwosemicirclesofaclosedinsulatorholdershallbeconsistentwiththeshapeofthesteelcapoftheinsulator,soastoavoidlargestressconcentrationinthestressprocess.Alldouble-wingholdersshallconformtothespecificationsofcorrespondinglinkfittings,andshallbeequippedwithbackupprotectiondevices(suchasclosingbolts)topreventthemfromfallingoff.Crossarmholdersmustadapttothespecificationsofthetowermaterials,andtheassemblyofthemshallbefirm.Thespecificationsoftensionpullersshallbedeterminedaccordingtotheloadandthetensionmode.

7.14Intheworkofreplacingsuspensioninsulatorstringsormovingconductors,whenthesinglesuspensionwiredeviceisused,thereshallbebackupprotectionmeasurestopreventtheconductorsfromfallingoff.

7.15Whenexchangingandtransferringheavytoolsupanddown,thecontrolropeshallbefastenedtopreventthetransferredobjectsfromcollidingwitheachotherandaccidentallycollidingwiththebearingtoolsintheworkingstate.

7.16Insulatingropesshallbekeptcleananddry,andshallbepreventedfromrubbingagainstthetowermaterials.Dampenedinsulatingropesarestrictlyprohibitedtobeusedinliveworking.

7.17Ifzeroandlowresistanceinsulatorsarefoundduringlivetestingofinsulators,theyshallberetested2~3times.

7.18Beforethereplacedinsulatorstringisseparatedfromtheconductor,whenthefirstinsulatornearthecrossarmisdisassembledorinstalled,adedicatedshort-circuitingwiremustbeusedbeforedirectoperation.

7.19Theequipotentialworkermusthavebackupprotectionwhenenteringorleavingequipotentialandworkingatequipotential,andthemid-potentialworkermustalsohavebackupprotectionduringwork.

Testoftools

8.1ThedesignofliveworkingtoolsshallconformtotherequirementsofGB/T18037.Conductiveclothing,insulatingropes,insulatingrods,insulatorholders,etc.,shallpasstypetestsandleavingfactorytestsinaccordancewiththerequirementsofGB/T6568,GB/T13035,GB13398,DL/T463,DL/T878.

8.2ThetoolsshallbesubjectedtoelectricaltestsandmechanicaltestsonaregularbasisaccordingtothetestmethodsofDL/T976.Thetestcyclesareasfollows:

a)electricaltests:preventivetestsshallbeconductedonceayear,andinspectiontestsshallbeconductedonceayear,andtheintervalbetweentwotestsshallbehalfayear.

b)mechanicaltests:preventivetestsshallbeconductedonceayearforinsulatingtoolsandonceeverytwoyearsformetaltools.

8.3Contentsandrequirementsofpreventivetests

a)Powerfrequencywithstandvoltagetest:thetestsampleshallbetestedentirely;theinsulationlengthofthetestsamplebetweenthetestelectrodesshallbe3.7m;thewithstandvoltageshallbe580kV;thetimeshallbe3min.Itisqualifiedifnobreakdown,flashoveroroverheatingoccur.

b)Switchingimpulsewithstandvoltagetest:theinsulationlengthofthetestsamplebetweenthetestelectrodesshallbe3.7m;thestandardswitchingimpulsewave(+250μs/2500μs)shallbeapplied;thevoltageamplitudeshallbe1050kV;thetestsampleshallwithstand15times.Itisqualifiedifnobreakdownorflashoveroccur.

c)Staticloadtest:aloadof1.2timestheweightoftheratedworkingloadshallbeappliedfor1min.Itisqualifiedifnopermanentdeformationordamageoccur.

d)Dynamicloadtest:3timesofac

温馨提示

  • 1. 本站所有资源如无特殊说明,都需要本地电脑安装OFFICE2007和PDF阅读器。图纸软件为CAD,CAXA,PROE,UG,SolidWorks等.压缩文件请下载最新的WinRAR软件解压。
  • 2. 本站的文档不包含任何第三方提供的附件图纸等,如果需要附件,请联系上传者。文件的所有权益归上传用户所有。
  • 3. 本站RAR压缩包中若带图纸,网页内容里面会有图纸预览,若没有图纸预览就没有图纸。
  • 4. 未经权益所有人同意不得将文件中的内容挪作商业或盈利用途。
  • 5. 人人文库网仅提供信息存储空间,仅对用户上传内容的表现方式做保护处理,对用户上传分享的文档内容本身不做任何修改或编辑,并不能对任何下载内容负责。
  • 6. 下载文件中如有侵权或不适当内容,请与我们联系,我们立即纠正。
  • 7. 本站不保证下载资源的准确性、安全性和完整性, 同时也不承担用户因使用这些下载资源对自己和他人造成任何形式的伤害或损失。

评论

0/150

提交评论