




已阅读5页,还剩24页未读, 继续免费阅读
版权说明:本文档由用户提供并上传,收益归属内容提供方,若内容存在侵权,请进行举报或认领
文档简介
GE-FANUC SERIES 90-70 (v7.04) Page 1Auxiliary Boiler - Boiler Control - A Processor ConfigurationGGGG EEEEE FFFFF AAA N N U U CCCC G E F A A NN N U U C G GGG EEEE FFF AAAAA N N N U U C G G E F A A N NN U U C GGG EEEEE F A A N N UUU CCCC AAA U U TTTTT OOO M M AAA TTTTT IIIII OOO N N A A U U T O O MM MM A A T I O O NN N AAAAA U U T O O M M M AAAAA T I O O N N N A A U U T O O M M A A T I O O N NN A A UUU T OOO M M A A T IIIII OOO N N (*)( )( CENTRAL PLC CONFIGURATION )( )( )( TOTAL DISCRETE I/O (%I + %Q): 128 )( )( HIGHEST CONFIGURED REFERENCES )( - )( DISCRETE INPUT (%I) : 1104 )( DISCRETE OUTPUT (%Q) : 16 )( )( ANALOG INPUT (%AI) : 24 )( ANALOG OUTPUT (%AQ) : 4 )( )( REGISTER MEMORY (%R) : 0 )( )(*)Folder: C:LM90BCS_A GE-FANUC SERIES 90-70 (v7.04) Page 2Auxiliary Boiler - Boiler Control - A Processor Configuration RACK 0 PS 1 2 3 4 5 6 7 8 9 = P R O G R A M M E D C O N F I G U R A T I O N = PWR711CGR 772BEM 713RCM 711BEM 731CMM 742 100W FLOAT XMTR RCM GBC1 ETHNET 512 KB DevicesRef Adr BUS: 2%I01025 Folder: C:LM90BCS_A RackGE-FANUC SERIES 90-70 (v7.04) Page 3Auxiliary Boiler - Boiler Control - A Processor ConfigurationSERIES 90-70 MODULE IN RACK 0 SLOT 0 SOFTWARE CONFIGURATION SLOT Catalog #: IC697PWR711 POWER SUPPLY 120/240 VAC 100W 0 PWR711 100W SERIES 90-70 MODULE IN RACK 0 SLOT 1 SOFTWARE CONFIGURATION SLOT Catalog #: IC697CGR772 772 CGR REDUNDANT CPU 512K FXD 1 CGR 772 IOScan-Stop: NO Baud Rate : 19200 FLOAT Passwords : ENABLED Parity : ODD Redund Type: PRIMARY Stop Bits : 1 SFC Faults : DISABLED Data Bits : 8 Modem TT : 0 1/100 Second / Count 512 KB Idle Time : 10 Seconds Mode : SNP Watchdg Tmr: 200 msec Folder: C:LM90BCS_A SlotGE-FANUC SERIES 90-70 (v7.04) Page 4Auxiliary Boiler - Boiler Control - A Processor ConfigurationSERIES 90-70 MODULE IN RACK 0 SLOT 1 SOFTWARE CONFIGURATION SLOT Catalog #: IC697CGR772 772 CGR REDUNDANT CPU 512K FXD 1 CGR 772 Sweep Mode : NORMAL Bkgnd Tmr : 5 msec FLOAT Prg Window : COMPLETE Prg Wnd Tmr: 255 msec Syscomm Mde: COMPLETE SysComm Tmr: 255 msec Chksum Wrds: 16 512 KB SERIES 90-70 MODULE IN RACK 0 SLOT 1 SOFTWARE CONFIGURATION SLOT Catalog #: IC697CGR772 772 CGR REDUNDANT CPU 512K FXD 1 CGR 772 Ctrl Strgy : GHS FLOAT Fail Wait : 60 msec - SHARED I/O - Ref Adr : %I00001 LENGTH : 1024 512 KB Ref Adr : %Q00001 LENGTH : 1024 Ref Adr : %M00001 LENGTH : 2048 Ref Adr : %R00001 LENGTH : 1024 Ref Adr : %AI0001 LENGTH : 64 Ref Adr : %AQ0001 LENGTH : 64 Folder: C:LM90BCS_A SlotGE-FANUC SERIES 90-70 (v7.04) Page 5Auxiliary Boiler - Boiler Control - A Processor ConfigurationSERIES 90-70 MODULE IN RACK 0 SLOT 1 SOFTWARE CONFIGURATION SLOT Catalog #: IC697CGR772 772 CGR REDUNDANT CPU 512K FXD 1 CGR 772 Port 1 Mode: SNP Port 2 Mode: SNP FLOAT SNP Mode : SLAVE SNP Mode : SLAVE Baud Rate : 19200 Baud Rate : 19200 Flow Contrl: N/A Flow Contrl: N/A Parity : ODD Parity : ODD 512 KB Stop Bits : 1 Stop Bits : 1 Timeout : LONG Timeout : LONG TurnA Delay: 0 TurnA Delay: 0 SNP ID : SNP ID : SERIES 90-70 MODULE IN RACK 0 SLOT 2 SOFTWARE CONFIGURATION SLOT Catalog #: IC697BEM713 BUS TRANSMITTER 2 BEM 713 Remote RCM : YES XMTR Rev A Bus Transmitter Module (IC697BEM713A) must be placed to the right of all modules that can generate interrupts in the main rack. Folder: C:LM90BCS_A SlotGE-FANUC SERIES 90-70 (v7.04) Page 6Auxiliary Boiler - Boiler Control - A Processor ConfigurationSERIES 90-70 MODULE IN RACK 0 SLOT 3 SOFTWARE CONFIGURATION SLOT Catalog #: IC697RCM711 REDUNDANT COMM MODULE 3 RCM 711 RCM SERIES 90-70 MODULE IN RACK 0 SLOT 5 SOFTWARE CONFIGURATION SLOT Catalog #: IC697CMM742 ETHERNET I/F FOR 90-70 HI PERF 5 %I, %Q lengths are bits; %AI, %AQ, %R are words CMM 742 Config Mode : TCP/IP ETHNET Status Address : %I01025 Status Length : 80 IP Address : 192.168.101.93 Subnet Mask : 255.255.255.0 Gateway IP Address : 0.0.0.0 Name Server IP Address : 0.0.0.0 Network Time Sync : NONE Folder: C:LM90BCS_A SlotGE-FANUC SERIES 90-70 (v7.04) Page 7Auxiliary Boiler - Boiler Control - A Processor ConfigurationSERIES 90-70 MODULE IN RACK 0 SLOT 5 SOFTWARE CONFIGURATION SLOT Catalog #: IC697CMM742 ETHERNET I/F FOR 90-70 HI PERF 5 CMM 742 - PORT CONFIGURATION - ETHNET - Station Mgr Port - - S/W Load Port - Data Rate : 19200 Data Rate : 19200 Parity : NONE Parity : ODD Stop Bits : 1 Stop Bits : 1 Flow Contrl: NONE Flow Contrl: NONE TurnA Delay: NONE TurnA Delay: NONE Timeout : LONG Timeout : LONG Folder: C:LM90BCS_A SlotGE-FANUC SERIES 90-70 (v7.04) Page 8Auxiliary Boiler - Boiler Control - A Processor ConfigurationThere are no GENIUS blocks configured in the Bus Address range 0. 7There are no GENIUS blocks configured in the Bus Address range 8. 15There are no GENIUS blocks configured in the Bus Address range 16. 23Rack 0 Slot 4 Bus 1 BUS ADR BUS ADR BUS ADR BUS ADR BUS ADR BUS ADR BUS ADR BUS ADR 24 25 26 27 28 29 30 31 BEM 733 BEM 731 BEM 731 REMSCAN GBC1 GBC1 DROP016 I/O MAP Devices %I00001 BUS: 2 %Q00001 %AI0001 %AQ0001 Folder: C:LM90BCS_A BusGE-FANUC SERIES 90-70 (v7.04) Page 9Auxiliary Boiler - Boiler C
温馨提示
- 1. 本站所有资源如无特殊说明,都需要本地电脑安装OFFICE2007和PDF阅读器。图纸软件为CAD,CAXA,PROE,UG,SolidWorks等.压缩文件请下载最新的WinRAR软件解压。
- 2. 本站的文档不包含任何第三方提供的附件图纸等,如果需要附件,请联系上传者。文件的所有权益归上传用户所有。
- 3. 本站RAR压缩包中若带图纸,网页内容里面会有图纸预览,若没有图纸预览就没有图纸。
- 4. 未经权益所有人同意不得将文件中的内容挪作商业或盈利用途。
- 5. 人人文库网仅提供信息存储空间,仅对用户上传内容的表现方式做保护处理,对用户上传分享的文档内容本身不做任何修改或编辑,并不能对任何下载内容负责。
- 6. 下载文件中如有侵权或不适当内容,请与我们联系,我们立即纠正。
- 7. 本站不保证下载资源的准确性、安全性和完整性, 同时也不承担用户因使用这些下载资源对自己和他人造成任何形式的伤害或损失。
最新文档
- 代理合同服务质量保证书范本
- 物业管理合同范本及法律风险提示
- 2025年国内旅游投资合作合同协议
- 2025年房地产咨询服务合同协议
- 2025年仓储货物运输合同
- 2025年建筑工程施工许可证备案合同协议
- 零售餐饮服务业预付卡发行合同协议
- 2025河南省卫生健康人才中心招聘4人考前自测高频考点模拟试题及答案详解(夺冠)
- 2025年福建省晋江市建设投资控股集团有限公司及其权属子公司招聘31人考前自测高频考点模拟试题及答案详解(典优)
- 2025年4月广东深圳市福田区区属公办高中面向全国遴选校长1人考前自测高频考点模拟试题有完整答案详解
- 2025国企竞聘上岗与干部竞聘上岗笔试题及答案
- 人工智能与建筑产业体系智能化升级研究报告
- 武科大大学生手册考试内容及答案
- 集装箱吊装专项施工方案
- 2025年中国家用WiFi路由器行业市场全景分析及前景机遇研判报告
- 2025年领导干部任前廉政法规知识考试题库(含答案)
- 2025年山东省济宁市邹城市第十一中学中考二模数学试题
- 信息技术基础教程(WPS版)课件 第3章 Windows 10 操作系统的使用
- 小鹿斑比题目及答案
- 2024超声法检测混凝土缺陷技术规程
- 2025-2030中国建筑行业供应链金融发展现状与前景分析
评论
0/150
提交评论