已阅读5页,还剩27页未读, 继续免费阅读
版权说明:本文档由用户提供并上传,收益归属内容提供方,若内容存在侵权,请进行举报或认领
文档简介
ELECTROCARDIOGRAPHY & CENTRAL VENOUS CATHETERIZATION,钟静,ELECTROCARDIOGRAPHY,lead II the largest P wave voltages of any surface lead approximately 60 from the right arm to the left leg, which is parallel to the electrical axis of the atria enhances the diagnosis of arrhythmias and the detection of inferior wall ischemia,ELECTROCARDIOGRAPHY,Lead V5 lies over the fifth intercostal space at the anterior axillary line a good compromise for detecting anterior and lateral wall ischemia a true V5 lead is possible only on operating room ECGs with at least five lead wires a modified V5 can be monitored by rearranging the standard three-limb lead placement,ELECTROCARDIOGRAPHY,Leads II and V5 should be monitored simultaneously The preferred lead for monitoring depends on the location of any prior infarction or ischemia Esophageal leads are even better than lead II for arrhythmia diagnosis but have not yet gained general acceptance in the operating room,1 心房上部 2 心房中部 3 心房下部 4 心室上部,Esophageal leads,ELECTROCARDIOGRAPHY,How to lower the skins electrical resistance? conductive gel cleansing the site with alcohol a degreasing agent mechanically exfoliating the superficial skin layer,Clinical Application,arrhythmias myocardial ischemia conduction abnormalities pacemaker malfunction,Clinical Consideration,Simulate arrhythmias patient or lead-wire movement use of electrocautery 60-cycle interference also called electrical interference, AC interference, is caused by electrical power leakage and faulty electrodes,Clinical Consideration,Digital readout of heart rate may be misleading because of monitor misinterpretation of artifacts or large T wavesoften seen in pediatric patientsas QRS complexes Monitoring filters incorporated into the amplifier may lessen artifacts,How to diagnose myocardial ischemia?,Lead to distortion of the ST segment and impede the diagnosis of ischemia To interpret ST-segment changes properly, the ECG must be standardized so that a 1-mV signal results in a deflection of 10 mm on a standard strip monitor Automated ST-segment analysis increases the sensitivity of ischemia detection Unfortunately, the efficacy has not been documented,How to diagnose myocardial ischemia?,A flat or downsloping ST-segment depression exceeding 1 mm, 60 or 80 ms after the J point (the end of the QRS complex) Particularly in conjunction with T wave inversion ST-segment elevation with peaked T waves WolffParkinsonWhite syndrome, bundle branch blocks, extrinsic pacemaker capture, and digoxin therapy may preclude the use of ST-segment information,Attention,The audible beep associated with each QRS complex should be loud enough to detect rate and rhythm changes when the anesthesiologists visual attention is directed elsewhere,CENTRAL VENOUS CATHETERIZATION,Indications,monitoring central venous pressure (CVP) administration of fluid to treat hypovolemia and shock infusion of caustic drugs and total parenteral nutrition aspiration of air emboli insertion of transcutaneous pacing leads gaining venous access in patients with poor peripheral veins,Contraindications,Renal cell tumor extension into the right atrium or fungating tricuspid valve vegetations Internal jugular vein cannulation is relatively contraindicated in patients who are receiving anticoagulants or who have had an ipsilateral carotid endarterectomy because of the possibility of unintentional carotid artery puncture,Techniques & Complications,The catheters tip lies just above or at the junction of the superior vena cava and the right atrium Inspiration will increase or decrease CVP because this location exposes the catheter tip to intrathoracic pressure depending on whether ventilation is controlled or spontaneous CVP should be measured during end expiration,Techniques & Complications,Catheterization of the subclavian vein is associated with a significant risk of pneumothorax during insertion line-related infection the longer the catheter stays in place The right internal jugular vein provides a combination of accessibility and safety Left-sided catheterization increases the risk of vascular erosion, pleural effusion, and chylothorax,Cannulation techniques,a catheter over a needle (similar to peripheral catheterization) a catheter through a needle (requiring a large-bore needle stick) a catheter over a guidewire (Seldingers technique),Right internal jugular cannulation,Patient position: trendelenburg position to decrease the risk of air embolism and to distend the internal jugular vein Full aseptic technique including sterile gloves, mask, bactericidal skin preparation, and sterile drapes,Right internal jugular cannulation,The two heads of the sternocleidomastoid muscle and the clavicle form the three sides of a triangle A 25-gauge needle is used to infiltrate the apex of the triangle with local anesthetic The internal jugular vein is found along the medial border of the lateral head of the sternocleidomastoid Toward the ipsilateral breast nipple at an angle of 30 to the skin Aspiration of venous blood confirms the veins location,Right internal jugular cannulation with seldingers technique,Right internal jugular cannulation,The possibility into the carotid artery can be decreased by transducing the vessels pressure waveform comparing the bloods color or PaO2 with an arterial sample An 18-gauge thin-wall needle is advanced along the same path as the locator needle When free blood flow is achieved, a J-wire with a 3-mm-radius curvature is introduced The needle is removed, and a pliable silastic catheter is advanced over the wire,Right internal jugular cannulation,The guidewire is removed, with a thumb placed over the catheter hub to prevent aspiration of air until the intravenous catheter tubing is connected to it The catheter is then secured and a sterile dressing is applied Correct location is confirmed with a chest radiograph The catheters tip should not be allowed to migrate into the heart chambers Fluid-administration sets should be changed every 72 h,Complications,Infection Air or thrombus embolism Arrhythmias (indicating that the catheter tip is in the right atrium or ventricle) Hematoma Pneumothorax, hemothorax, hydrothorax, chylothorax Cardiac perforation, cardiac tamponade Trauma to nearby nerves and arteries Thrombosis Some of these complications can be attributed to poor technique,CVP,CVP approximates right atrial pressure, which is a
温馨提示
- 1. 本站所有资源如无特殊说明,都需要本地电脑安装OFFICE2007和PDF阅读器。图纸软件为CAD,CAXA,PROE,UG,SolidWorks等.压缩文件请下载最新的WinRAR软件解压。
- 2. 本站的文档不包含任何第三方提供的附件图纸等,如果需要附件,请联系上传者。文件的所有权益归上传用户所有。
- 3. 本站RAR压缩包中若带图纸,网页内容里面会有图纸预览,若没有图纸预览就没有图纸。
- 4. 未经权益所有人同意不得将文件中的内容挪作商业或盈利用途。
- 5. 人人文库网仅提供信息存储空间,仅对用户上传内容的表现方式做保护处理,对用户上传分享的文档内容本身不做任何修改或编辑,并不能对任何下载内容负责。
- 6. 下载文件中如有侵权或不适当内容,请与我们联系,我们立即纠正。
- 7. 本站不保证下载资源的准确性、安全性和完整性, 同时也不承担用户因使用这些下载资源对自己和他人造成任何形式的伤害或损失。
最新文档
- 单片机原理及应用(第二版) 课件 第4章 中断、定时与串行通信
- 2024年危险化学品经营单位企业主要负责人安全生产模拟考试题库
- 用户组限流方案
- 《无线数据传输收发信机通 用规范GBT+16611-2017》详细解读
- 幼儿园小班语言课件:《最好听的歌》
- 2022年度辽宁省安全员之C证(专职安全员)测试卷(含答案)
- 2022年度辽宁省安全员之C1证(机械安全员)通关提分题库(考点梳理)
- 工程劳务合同范本(35篇)
- 幼儿教育体育活动方案6篇
- 2024年涡流泵项目合作计划书
- GB/T 20833-2007旋转电机定子线棒及绕组局部放电的测量方法及评定导则
- GB 19079.2-2005体育场所开放条件与技术要求第2部分:卡丁车场所
- 汉语阅读教程第一册 第22课
- 基于单片机的交流数字电压检测系统仿真设计-数字显示模块设计毕业设计(论文)说明书
- ABB开关分合闸故障排查及测试课件
- 病原微生物实验室生物安全标识
- 2021年吉林通用航空职业技术学院辅导员招聘试题及答案解析
- 委托修缮房屋协议书
- DB11-T 2000-2022 建筑工程消防施工质量验收规范
- 缺勤学生追踪记录表
- 结构加固检验批质量验收表格
评论
0/150
提交评论