Risk Management for Medical Devices - ASQ Raleigh:医疗器械的风险管理——ASQ罗利.ppt_第1页
Risk Management for Medical Devices - ASQ Raleigh:医疗器械的风险管理——ASQ罗利.ppt_第2页
Risk Management for Medical Devices - ASQ Raleigh:医疗器械的风险管理——ASQ罗利.ppt_第3页
Risk Management for Medical Devices - ASQ Raleigh:医疗器械的风险管理——ASQ罗利.ppt_第4页
Risk Management for Medical Devices - ASQ Raleigh:医疗器械的风险管理——ASQ罗利.ppt_第5页
已阅读5页,还剩25页未读 继续免费阅读

下载本文档

版权说明:本文档由用户提供并上传,收益归属内容提供方,若内容存在侵权,请进行举报或认领

文档简介

Risk Management for Medical Devices,Safe and Effective Products Paul McDaniel ASQ CQM/OE Executive VP Operations and QA Sicel Technologies,Overview,Product Life Cycle Model Role Process Hints In-depth discussion of a Risk Management Analytical Tool: FMEA,Risk Management Defined (a practitioners definition),Risk: probability of harm occurring AND the severity of harm Risk Management: Use of relevant information to identify possible harmful events, to assess the events acceptability in the eyes of the at risk population (probability*severity), and exert effective controls of the risk,Risk Analysis -Intended use and Id of Char related to safety of the device -Id hazards -Est risk for each hazardous situation,Risk evaluation,Risk Control -Option analysis -Implement controls -Residual risk evaluation -Risk/benefit analysis -Risks arising from control measures -Completeness of risk control,Risk Assessment,Evaluation of overall residual risk acceptability,Risk Management Report,Production and post-production information,Risk Management,Adapted from ISO 14971:2007 Figure 1,Product Life Cycle Model Role,Understand the Regulatory Model A product life cycle has many phases Information/Products/Design at the start of a phase is input; possibly input requirements Information/Products/Design at the end of each phase is output Outputs must be verified against inputs The model assumes verification at each phase end,Product Life Cycle Model Role,The Current State of the Risk Management Standard Assumes the Regulatory model You may follow the described process and be confused unless you recognize the phase boundaries How can I determine the answer to “is risk acceptable” if Im just defining design inputs The planned mitigation is acceptable, detail design may introduce new information, stay alert in the next phase!,Risk Management by Phase,Design Input (Hazard Analysis/Fault Tree) Focus on generating product “shall not do” or “shall comply with standard.” type of specification requirements Detailed Design (Fault Tree/FMEA) Look to your product architecture and add architecture interface risks to your analyses Further on, examine higher risk areas and product failure risks in detail,Risk Management by Phase,Design Verification/Validation Watch for occurrence of anticipated but “intended to be” mitigated risks Risk Control failure Assess impact of V&V findings for new risks needing analyses We didnt imagine that would happen: Risk? Listen to any customer feedback for risk acceptability “Those safety lock outs are too confusing to work with, can we disable them?”,Risk Management by Phase,Commercial Distribution/Disposal Vigilance Reporting is a Risk Analysis Update Opportunity NEW for 2007! Production feedback into the Risk Analysis Am I seeing higher rates of occurrence? Are new failure modes presenting themselves that we havent analyzed? Are we having control failures or excessive cause failures,Risk Analysis in Production,Non-conforming material and Material Review Board Processes? Can they effectively consider risks on each occurrence? Control charts, acceptance data Are risk controls part of acceptance testing? Frequency of occurrence suggesting anything “Risk of failure was ranked as remote yet weve had three catastrophic hot-pot test failures this month!”,Risk Analysis in Production,Comment period,Process Considerations,Define the scope of your analysis What systems, what interfaces, who as user. The records produced will be subject to second guessing if harm occurs: dont allow hindsight to change the rules Document your information sources! When you made your risk acceptability decision, what information was available and used? We can only be diligent, not psychic,Analysis Scope,Intended Use: Use for which the product, process or service is intended according to the specifications, instructions, and information supplied by the manufacturer Essential Performance: Performance necessary to achieve freedom from unacceptable risk Note: is most easily understood by considering whether its absence or degradation would result in an unacceptable risk You must have these two clearly in front of the analysis team.,Process Considerations,Use a Risk Source List as a Reminder ISO 14971 has such lists Add your Industrys Experience If a harmful event has been reported, it has higher mitigation priority than hypothetical risks flag real occurrences in your analyses Rely on accepted standards If there is a “test” standard, understand the underlying reason for the tests,Process Considerations,Sources of harm should suggest action electricity is not harmful, electrocution is A hazard exists A sequence of events leads to a hazardous situation (normal or fault conditions) The hazardous situation has a probability (P1) Harm occurs from the situation A probability of harm exists (P2) A severity of outcome can be assigned (S) Risk = S, P1 x P2,Process Considerations,While defining the system inputs, what harmful things can occur: Very early on, a “Preliminary Hazard Analysis” can screen out higher risk approaches What are the harmful things that the system can do considering: user, patient, environment or property (a subject),Process Considerations,Typically, the Device Design Requirements Are Broken Down Into Smaller Pieces During Detailed Design focus on interfaces, signal and data path integrity trace system requirements to sub-system Use Fault Tree Analysis (top down) Consider Using Failure Modes and Effects Analysis (bottoms up),Process Considerations,Observe Verification/Validation findings for unanticipated device behavior the best design analysts miss things Initiate a process for V&V findings classification did harm occur?, or if the behavior re-occurs, could harm occur? if I cant recreate the behavior, I still may have to mitigate it,Risk Management Process Tools,System Hazard Analysis (design input),Draw boundaries between the system and the at risk subject and define harmful events Energy sent across a boundary Look for potential to kinetic energy transition did you control the transition Changes in state may be potentially harmful Your seed list may leave you with many “deferred answers”,Probability and Severity Estimates,Risk management relies on expert judgment so dont let novices work alone! Focus on one device, one device lifetime Set Quantitative or Qualitative criteria high probability is.several times in a device lifetime?, 1 per million uses moderate injury ismedical attention to return to pre-risk exposure state,Probability and Severity (use graphical techniques),Increasing Severity,Increasing probability,unacceptable,okay,Increasing Severity,Increasing probability,no risk or too great a risk is easy, what about moderate risks?,Split up the quadrants to refine the estimates in stages of analysis,Detailed Risk Analyses,One of the more popular design evaluation tools is the Failure Modes and Effects Analysis (FMEA) IEC 60812, Analysis techniques for system reliability - Procedure for failure modes and effects analysis FMEA is used more for design evaluation than for design development Works for manufacturing processes too!,Detailed Risk Analyses,Definitions: FMEA: a structured analytical technique which determines relationships between basic element failure characteristics and the system failures Failure mode is how a failure manifests itself (system shuts down) Failure mechanism is why a failure occurs (defect in the transistor silicon),Process Needs for a FMEA,Prior risk analysis work to build on if available System level harmful events will be analyzed to see how component/assemblies may contribute to the harm cause System failure and degraded modes definitions functional block diagrams may be needed for each operating/failure mode,FMEA Process Needs,a design solution, down to the component level

温馨提示

  • 1. 本站所有资源如无特殊说明,都需要本地电脑安装OFFICE2007和PDF阅读器。图纸软件为CAD,CAXA,PROE,UG,SolidWorks等.压缩文件请下载最新的WinRAR软件解压。
  • 2. 本站的文档不包含任何第三方提供的附件图纸等,如果需要附件,请联系上传者。文件的所有权益归上传用户所有。
  • 3. 本站RAR压缩包中若带图纸,网页内容里面会有图纸预览,若没有图纸预览就没有图纸。
  • 4. 未经权益所有人同意不得将文件中的内容挪作商业或盈利用途。
  • 5. 人人文库网仅提供信息存储空间,仅对用户上传内容的表现方式做保护处理,对用户上传分享的文档内容本身不做任何修改或编辑,并不能对任何下载内容负责。
  • 6. 下载文件中如有侵权或不适当内容,请与我们联系,我们立即纠正。
  • 7. 本站不保证下载资源的准确性、安全性和完整性, 同时也不承担用户因使用这些下载资源对自己和他人造成任何形式的伤害或损失。

评论

0/150

提交评论