[电信]EWSDtestreportofLiaoNingMiniSCPV13A.doc_第1页
[电信]EWSDtestreportofLiaoNingMiniSCPV13A.doc_第2页
[电信]EWSDtestreportofLiaoNingMiniSCPV13A.doc_第3页
[电信]EWSDtestreportofLiaoNingMiniSCPV13A.doc_第4页
[电信]EWSDtestreportofLiaoNingMiniSCPV13A.doc_第5页
已阅读5页,还剩2页未读 继续免费阅读

下载本文档

版权说明:本文档由用户提供并上传,收益归属内容提供方,若内容存在侵权,请进行举报或认领

文档简介

Online Test Report of Liaoning Originating Oriented Remote Access in GW1. OBJECTIVEThe aim of this document is to describe the on-line tests to be executed for Liaoning GW Remote Access CHNV13a.1.1 IntroductionCustomers from Liaoning Province are requesting GW Remote Access feature. GW remote access feature is kind of digit translation which is add the prefix from translated result as the called party number and it will be transferred to GW switch in the PSTN network. For example: PSTN subscriber A:makes a phone call to Mobile subscriber B: The original GW switch should be able to analyze the B party number. And if the analyzed result shows the B number indicating another GW switch (for instance: CPT=0531), the original GW will add the 0531 as prefix into B party number (that is to say 053113905310000 will be the final B party number). Then the B number should be transferred to another GW, which is 0531. That is so called: GW remote access. For mobile party number analyzing, combinations of 106 should able to be discriminated in China. According DBSIZE of CPT, the maximum value is 65535, which means only105 CPT can be analyzed in EWSD.Furthermore, customers also request that subscribers in different network operating companies can be distinguished when GW remote access is used. That is kind of authentication, subscribers of one network operating company are allowed to use GW remote access, subscribers of others are prohibited to use it. In general, this feature is called “Originating Oriented Remote Access in GW.1.2 Valid customer and versionValid for Liaoning Province customer and CHNv13a.1.3 Test responsibilityMs. Wang Meihua is responsible for the whole system test. Tel:2. SOFTWAREThe following feature patches are needed: Patch nameLoadtypeFunctionAV983L4D.A0A030,04,52CT, special service key=999AV984L4D.A0A030,04,52CT, function set for skey=999 includes Hot-line and speed dialingAV985L4D.A0A030,04,52CT, OP:FCI is not to be sentAV986L4D.A0A030,04,52CT, called party number is treated as ACIAV989L4D.A0A030,04,52CT, return result handlingAV992L4D.A0A030,04,52CT, Second search result treatment will be same as first onAV993L4D.A0A030,04,52CT, Directly send IN_DB_REQUESTAV994L4D.A0A030,04,52CT, First digit of Hot line from IN_DB_RESULT is stored in DUMZAV995L4D.A0A030,04,52CT, Action of OP: CI is allowed and PRD is allowed (for authentication)AV996L4D.A0A030,04,52CT, omit release indicator in second accessing resultAV997L4D.A0A030,04,52CA, First database access indicator is set (switch patch for two little feature)AV998L4D.A1A030,04,52CA, Calling party number should be authenticatedAV999L4D.A0A030,04,52CA, Copy fixed 8 digits of calling party number into the field of ACICT standing for Code Translation purpose.CA standing for Calling party number AuthenticationNote: 1. The called party DN translation function can be implemented by patch: AV983, AV984, AV985, AV986, AV989, AV992, AV993, AV994, AV995, and AV996.2. To also implement the authentication function, three more patches are necessary: AV997, AV998, and AV999. Among them, theres a switch patch AV997. Attention that the three patches should work together with the above 10 patches (AV983,AV996) to realize the authentication function.3. The corresponding FR is CJ4362.4. CT stands for Code Translation purpose, while CA stands for Calling party number Authentication.3. TEST CONCEPT3.1 Simulative configurationFigure 1. Simulation configuration for online test*:to test completely, this trunk should be ISUP, as well as MFC and TUP.*:to test the SCP capability, large traffic should be used.In this simulative configuration, Local Switch A is simulated as two switches, one is PSTN CX, the other is PSTN TX. So, when a subscriber in PSTN CX dial a toll mobile phone number, PSTN CX selects the route to GW. After analyze, the GW decides the route whether to the PSTN TX, or to the MSC directly.3.2 Database/*IN data for SCCP layer in GW B:CR SCUSER: SSID=IN5, NETIND=NAT0, SSN=240, TCAPUS=Y;CR SCSS: SSID=IN5, SPC=0-0-1, NETIND=NAT0; /*/*CR SCCGPA: SSID=IN5, NETIND=NAT0, RTGP=PROG,# TTID=UNKNOWN, NP=ISDNTNP, NA=NATNO, GTDIG=00-0-630;ENTR SCDATA: SPC=0-0-1, NETIND=NAT0, MXMSGLEN=255,# USEXUDT=NO, SCCLSR=WB;/*IN trigger: CR INTRIG: PRID=CHNBNI, SKEY=999, SSID=IN5, ACNSEL=5, PROT=CS1, CHGINF=NOINTV,# RTGP=SPC, DPC=0-0-1, NETIND=NAT0, DACTINC=SNA4; ACT INTRIG: PRID=CHNBNI;CR INSCM: SCMID=CHNBNI, TYPE=TDP3, PRID=CHNBNI, PROP=PROP2, COLDIG=6;CR INSCMREF: SCMID=CHNBNI, CODE=013;ACT INSCMREF: TYPE=TDP3, CODE=013;/*CR DEST: DEST=NEW021, NEWCODE=021;CR CPT: DEST=MSC013, CODE=013; CRZOPT: CODE=013, ZONO=1, BILLING=METERING, TKZOINF=YES, SUCHCNTR=CNTR1; /*Simulative subscriber DN:ENTRAREACODE: LAC=021; CR DN: DN=A1300&A1399, LAC=021;CR CPT: CODE=A13, LAC=021, TRATYP=CPTDN;CRZOPT: CODE=A13, ZONO=1, BILLING=METERING, TKZOINF=YES, SUCHCNTR=CNTR1;CR SUB: LAC=021, DN=A1310, CAT=TXS, COSDAT=HOTLIMM- 0101; CR SUB: LAC=021, DN=A1311, CAT=TXS, COSDAT=HOTLIMM- D1; CR SUB: LAC=021, DN=A1312, CAT=TXS, COSDAT=HOTLIMM- D2; CR SUB: LAC=021, DN=A1313, CAT=TXS, COSDAT=HOTLIMM- C; CR SUB: LAC=021, DN=A1314, CAT=TXS, COSDAT=HOTLIMM- A; 3.3 Test case descriptionsTest Case No.1.1PurposeTo test the situation while the calling party is authorized and the called party DN will be translatedDescriptionThe call is just routed from the GW directly to MSC.CR INAUTH:ACI=02313220,TXSPROF=021-A1314;CR INAUTH:ACI=02132100,TXSPROF=021-A1314;CR INAUTH:ACI=013812,TXSPROF=021-A1310;In Local Exchange A, 0231 3220040 dial 013812345;In GW B, 021 3210040 dial 013812345;Test ResultPass!NoteIn the signaling trace, IN Database is visited twiceTest Case No.1.2PurposeTo test the situation while the calling party is authorized and the called party DN will be translatedDescription(one more digit required)CR INAUTH:ACI=02313220,TXSPROF=021-A1314;CR INAUTH:ACI=02132100,TXSPROF=021-A1314;CR INAUTH:ACI=013812,TXSPROF=021-A1311;CR INAUTH:ACI=0138123,TXSPROF=021-A1310; In Local Exchange A, 0231 3220040 dial 013812345;In GW B, 021 3210040 dial 013812345;Test ResultPass!NoteIn the signaling trace, IN Database is visited twiceTest Case No.1.3PurposeTo test the situation while the calling party is authorized and the called party DN will be translatedDescription(two more digit required)CR INAUTH:ACI=02313220,TXSPROF=021-A1314;CR INAUTH:ACI=02132100,TXSPROF=021-A1314;CR INAUTH:ACI=013812,TXSPROF=021-A1312;CR INAUTH:ACI=01381234,TXSPROF=021-A1310; In Local Exchange A, 0231 3220040 dial 013812345;In GW B, 021 3210040 dial 013812345;Test ResultPass!NoteIn the signaling trace, IN Database is visited twiceTest Case No.2.1PurposeThe calling party is authorized, but while checking the called party DN in the database, get the result -HOTLIMM-CDescriptionCR INAUTH:ACI=02313220,TXSPROF=021-A1314;CR INAUTH:ACI=02132100,TXSPROF=021-A1314;CR INAUTH:ACI=013821,TXSPROF=021-A1313;In Local Exchange A, 0231 3220040 dial 013821234;(short cut)In GW B, 021 3210040 dial 013821234;Test ResultPass!NoteIn the signaling trace, IN Database is visited twiceTest Case No.3.1PurposeWhile checking the calling party DN, get the result - HOTLIMM- CDescriptionNo matter the called party is or not authorized, the call is routed from GW directly to MSC.CR INAUTH:ACI=02313220,TXSPROF=021-A1313;CR INAUTH:ACI=02132100,TXSPROF=021-A1313;CR INAUTH:ACI=013812,TXSPROF=021-A1310;CR INAUTH:ACI=013821,TXSPROF=021-A1313;In Switch A, 0231 3220050 dial 013812345; (busy tone)In Switch A, 0231 3220050 dial 013821234; (short cut)In GW B, 021 3210050 dial 013812345;In GW B, 021 3210050 dial 013821234; (ring)Test ResultPass!NoteTest Case No.4.1PurposeThe calling party is not authorized (not in the database).DescriptionThe database:CR INAUTH:ACI=0231322004,TXSPROF=021-A1314; (authorized)CR INAUTH:ACI=0231322005,TXSPROF=021-A1313; (unauthorized)CR INAUTH:ACI=021321004,TXSPROF=021-A1314; (authorized)CR INAUTH:ACI=021321005,TXSPROF=021-A1313; (unauthorized)CR INAUTH:ACI=013812,TXSPROF=021-A1310;CR INAUTH:ACI=013821,TXSPROF=021-A1313;In Switch A, 02313220030 dial 013812345 and 013821234; (if the two called party both ring, the calling party is set authorized as default; if only 13821234 ring, the calling party is set unauthorized as default)In GW B, 0213210030 dial 013812345 and 013821234; (just the same)Test ResultPass!NoteAs to the analyze of the test result, the IN database is searched only once, so we can tell that the calling party is set unauthorized as default when its DN is not in the database, which is reasonable!Test Case No.4.2PurposeThe calling party DN is set in the wrong database,DescriptionCR INAUTH:ACI=02132100,TXSPROF=021-A1311(or A1312); (8 digits)OptionalCR INAUTH:ACI=021321005,TXSPROF=021-A1314; (9 digits)In GW B, 021 3210050 dial a call, no tone(either busy or idle or disconnected tone) can be heard in the handset for a long time.Test ResultPass?NoteIs this situation reasonable? -Lets suppose such prerequisite will fortunately never happen.Test Case No.5.1PurposeThe called party DN is not in the database, so will not be translated.DescriptionCR INAUTH:ACI=013812,TXSPROF=021-A1310;CR INAUTH:ACI=021321004,TXSPROF=021-A1314;CR INAUTH:ACI=021321005,TXSPROF=021-A1313;013821234 is the called party,if the calling party is authorized, in the second IN database search, the correct result cant be found, so the call is released after the first 6 digits are dialed.if the calling party is not authorized, the call can be set up via MSC.Test ResultERROR! -Pass!NoteThis situation is Unreasonable! -Mr. Wang Tao modified the patch AV989.Test Case No.5.2PurposeThe called party DN is not in the database, or an incomplete database.DescriptionCR INAUTH:ACI=013821,TXSPROF=021-A1312;CR INAUTH:ACI=01382111,TXSPROF=021-A1313;CR INAUTH:ACI=02132100,TXSPROF=021-A1314; ( ensure the second IN DB request)In GW B, 021 3210050 dial 013821234, it rings, via MSC,not compatible with that in Case 5.1Test ResultPass!NoteIn fact, this situation is reasonable.Test Case No.6.1PurposeTo test the situation when the trunk from A to B is a MFC trunk, calling party DN(including LAC) is requested.DescriptionMODIFY the attributes of the trunk:In GW B, ENTR AREACODE:CODE=0231; MOD TGRP: TGNO=tgno,NLAC=0231;ENTR TGDAT:TGNO=tgno,GCOD=AMAREQD;( to ensure the calling party DN+LAC will be transmitted)The call is just routed from the GW directly to MSC.CR INAUTH:ACI=02313220,TXSPROF=021-A1314;CR INAUTH:ACI=013812,TXSPROF=021-A1310;In Local Exchange A, 0231 3220040 dial 013812345;Test ResultPass! NoteTest Case No.7.1PurposeTo test the situation when the trunk from A to B is a TUP trunk, calling party DN(including LAC) is requested.DescriptionIn Local Exchange A, CR TRATCPT:CODE=013,TRAT=TRAT13;( to ensure the calling party DN+LAC will be transmitted)The call is just routed from the GW directly to MSC.CR INAUTH:ACI=02313220,TXSPROF=021-A1314;CR INAUTH:ACI=013812,TXSPROF=021-A1310;In Local Exchange A, 0231 3220040 dial 013812345;Test ResultPass! NoteTest Case No.8.1PurposeTo test the situation when the traffic is very highDescriptionTo really test the SCP process capability, avoid the problems caused by others, the simulative test configuration has been changed a little as following:The calling party and the called party are in the same Exchange:The calling party: 021 32101013210116 & 021 32102013210216The called party: 0 1381000113810016 & 1382000113820016Sub A1310 has changed to: COSDAT=HOTLIMM-1; (no trunks)CR INAUTH:ACI=02132101, PRID=CHNBNI, SCMID=CHNBNI, TXSPROF=021-A1314;CR INAUTH:ACI=02132102, PRID=CHNBNI, SCMID=CHNBNI, TXSPROF=021-A1314;CR INAUTH: ACI=013810, PRID=CHNBNI, SCMID=CHNBNI, TXSPROF=021-A1310;CR INAUTH: ACI=013820, PRID=CHNBNI, SCMID=CHNBNI, TXSPROF=021-A1310;Test ResultPass!NotePay attention to this test case, in which we just ignored some unknown problems caused by the test equipment or other reasons other than the SCP capability. In fact we just make a comparison of the results when using IN or not, in the sam

温馨提示

  • 1. 本站所有资源如无特殊说明,都需要本地电脑安装OFFICE2007和PDF阅读器。图纸软件为CAD,CAXA,PROE,UG,SolidWorks等.压缩文件请下载最新的WinRAR软件解压。
  • 2. 本站的文档不包含任何第三方提供的附件图纸等,如果需要附件,请联系上传者。文件的所有权益归上传用户所有。
  • 3. 本站RAR压缩包中若带图纸,网页内容里面会有图纸预览,若没有图纸预览就没有图纸。
  • 4. 未经权益所有人同意不得将文件中的内容挪作商业或盈利用途。
  • 5. 人人文库网仅提供信息存储空间,仅对用户上传内容的表现方式做保护处理,对用户上传分享的文档内容本身不做任何修改或编辑,并不能对任何下载内容负责。
  • 6. 下载文件中如有侵权或不适当内容,请与我们联系,我们立即纠正。
  • 7. 本站不保证下载资源的准确性、安全性和完整性, 同时也不承担用户因使用这些下载资源对自己和他人造成任何形式的伤害或损失。

评论

0/150

提交评论