




已阅读5页,还剩15页未读, 继续免费阅读
版权说明:本文档由用户提供并上传,收益归属内容提供方,若内容存在侵权,请进行举报或认领
文档简介
EI-2000GEI-2000G 型火灾报警控制器型火灾报警控制器( (联动型联动型) ) EI-2000G fire alarm control units(linkage type) 用户使用手册用户使用手册 user manual 蚌埠依爱消防电子有限责任公司蚌埠依爱消防电子有限责任公司 EI FIRE ELECTRONICS CO., LTD EI-2000G fire alarm control units(linkage type) user manual 1 在使用本控制器前,在使用本控制器前,请认请认真真阅读阅读以下全部内容,特以下全部内容,特别别是接是接线说线说明和有关注意事明和有关注意事项项, , 若有不明确的地方,可直接与本公司若有不明确的地方,可直接与本公司联联系。系。 Before using this control units, please read the following texts carefully. Pay special attention to the connection instructions and related notices. Seek additional help by contacting our company. 重要声明:重要声明: 火灾火灾报报警系警系统统能否能否长长期期稳稳定地运行,取决于定地运行,取决于产品可靠的质量、规范的安装、全面 的调试、定期的测试以及适时的维护,缺一不可!,缺一不可! Important Declaration: The long term stable running of the fire alarm system depends on its reliable quality, standard installation, overall debugging, regular testing and timely maintenance. They combine to contribute to the ideal effects. 第一章第一章 概述概述 Chapter 1 Introduction EI-2000G 型火灾报警控制器(联动型)集火灾报警、联动控制、防盗报警和可燃气报警等多 种功能于一体,并分别满足 GB4717-2005、GB16806-2006 等国标的要求,是面向二十一世纪的 综合型安防报警设备,可适用于各类大、中型工程。该产品广泛采用可编程逻辑器件、多任务并 行处理、CMOS 电路和网络技术,并采用模块化结构, 使整个系统功耗低,抗干扰、抗振动能力 强,工作可靠、性能稳定、误报率最低, 且扩展灵活、维护方便;采用大屏幕液晶显示技术, 方 便用户操作、使用。 EI-2000G Fire Alarm Control units (Linkage Type) integrates multiple functions such as the fire/theft/combustion gas alarm and linkage control. Complying with such national standards as GB4717-2005, GB16806-2006, it is a 21 century oriented integrative safety/alarm instrument and can be applied in large-scale and medium fire prevention projects. It adopts the program- able logic elements, multiple parallel processing CPUs, CMOS circuits and networks. It also features a modular structure, which guarantees low power consumption, powerful anti- interference/anti-vibration capability and a low fault report rate. It is stable, reliable, expandable and easy to maintain. EI-2000G fire alarm control units(linkage type) user manual 2 第二章第二章 主要技术指标主要技术指标 Chapter 2 Main Technical specifications 1. 交流电源(交流电源(AC power supply) 交流输入电压(AC Input Voltage):220V10, 50Hz1 交流输入功率(AC Input Power):240W 2备用电源(备用电源(Standby Power) DC24V 17Ah, 全密封免维护蓄电池(Sealing Storage Battery,free from maintenance) 3. 使用环境(使用环境(Operating Environment) 温度(Temperature):040; 相对湿度(Relative Humidity):95 ( 40) 4. 编址容量(编址容量(Addressing capacity) 回路容量(Loop Capacity):242 总容量(Total Capacity):4840 5. 总线长度(总线长度(Bus length):1500m 6外形尺寸(外形尺寸(Dimensions):5401800490 mm EI-2000G fire alarm control units(linkage type) user manual 3 第三章第三章主要功能和技术特点主要功能和技术特点 Chapter 3 Main function and Technical characteristic 1火灾报警功能火灾报警功能,能通过两总线挂接本公司生产的各类探测器、输入模块、手动报警按钮等火 灾触发部件和火灾显示盘、隔离器等,能以声、光信号发出火警警报, 并通过液晶显示火灾发生 时间、火警总数以及报警部件的地址、安装位置和部件类型等信息。 Fire Alarm: the two buses are available for fire alarm parts including the varieties of detectors, input modules, manual alarm buttons, as well as the fire display panel and isolators (produced by our company). The control units can produce sound and light alarms, and display the place otherwise the system make work improperly. 2.7 控制器的左侧面和后面分别留有穿线孔,可根据需要选择使用,交流电源输入端子位于控制 器右下侧,L、N、E 分别为火线、零线和地线。 There are threading holes at the left and rear side of the control units. The input terminals for the AC power are located at the down right side of the control units. L, N and E are live, null and earth wires. EI-2000G fire alarm control units(linkage type) user manual 6 第五章第五章 键盘、显示说明键盘、显示说明 Chapter 5 Keyboard and display 一一 、按键及开关说明、按键及开关说明(Keys instructions) 自动自动:用于切换联动控制状态,控制器上电启动或复位后,默认为手动手动状态,当按下自动键, 控制器处于自动控制状态,同时指示灯亮;再按一下时,控制器切换回到手动控制状态,同时指 示灯灭。 Auto: it is used to switch between the linkage control states. When the control units is power on or reset, the default state is manual. Press the auto button, the control units will shift to the auto-control state and the indicator lamp will be on simultaneously. Press the button a second time, the control units will return to manual control state and the indicator lamp dies out simultaneously. 自检自检:按下此键,对控制器面板上所有指示灯、液晶、直接输出按键、扬声器等进行自检。 有火警、盗警或可燃气报警时,自检键被屏蔽。 Self: pressing the button will activate the self-test of all indicator lamps on the control units panel, the digital tubes, LCD, direct output buttons and the loudspeaker. When there is a fire, theft or combustible gas alarm, the self-test button will be shielded automatically. 消音消音:当控制器有报警时,扬声器发出声响,按下消音键,则清除声响。 Silence: when the control units receives an alarm, the loudspeaker will let out sirens,Pressing this button can remove the alarm sound. 复位复位:对控制器进行复位。 Reset: reset the control units. 返回返回、确认确认:用于编程、设置、菜单操作等。 Return、Enter: it is used in programming, configuration and menu operation. F1F5:在不同菜单操作时,代表不同功能,在液晶最下方显示。 F1F5: These key have defferent function on defferetn menu state. And their function is display on LCD screen lastly row. 菜单:菜单:在正常显示状态下,按下该键进入菜单操作。 menu: Pressing this key in the normal display state leads to menu operation. 09:输入数据时为 09。 09: refers to the number 09 when you are inputting data. /: 对输出模块进行编程时,输入逻辑表达式时用。 /: employed in logic expressions during the programming of the output module. +:对输出模块进行编程时,输入逻辑表达式时用,表示逻辑“或” 。 +: employed in logic expressions during the programming of the output module. It means logic OR. ,:对输出模块进行编程时,输入逻辑表达式时用。 ,:employed in logic expressions during the programming of the output module. -/*:“-”号用于对楼层编辑时,输入负楼层, “*”号用于对输出模块进行编程时,输入逻辑 表达式用,表示逻辑“与” 。 EI-2000G fire alarm control units(linkage type) user manual 7 -/* : “-” is used to express a underground floor.“*”is employed in logic expressions during the programming of the output module. It means logic AND. 键盘锁:键盘锁:当置于“开”时,允许进行所有键操作;当置于“OFF”时,只能进行消音操作。 Keyboard Lock: When it is switched to ON, all key operations are allowed. When it is switched to off, only the silent operation can be carried out. 二、指示灯说明(二、指示灯说明(Indication lights instruction) 火警火警:当控制器发现有火警时,该指示灯亮。 Fire alarm: when the control units receives a fire alarm, it is power on. 预警预警:当控制器发现有预警时,该指示灯亮。 Pre-alarm: when the control units receives a warning alarm, it is power on. 监管监管:当控制器发现有盗警、可燃气报警、监管报警时,该指示灯亮。 Supervise alarm: when the control units receives a theft alarm, a combustible gas alarm and a supervise alarm , the light is on. 启动启动:当控制器启动输出模块时,该指示灯亮。 Start: when the control units startup the output module, the light is on. 反馈反馈:当控制器通过输出模块或输入模块接收到设备的动作反馈信号时,该指示灯亮。 Feedback: when the control units receives action feedback signals from the equipment through the output module or input module, the light is on. 屏蔽屏蔽:当控制器所挂接的部件被屏蔽时,该指示灯亮。 Disable: when the component connected with the control units is isolated, the light is on. 延时指示延时指示:当控制模块处于延时动作期间时,该指示灯亮。 Delay: when the output module is in the delay action state, the light is on. 气体喷洒气体喷洒:当控制器通过输出模块接受到喷洒装置的启动信号时,该指示灯亮。 Gas Insufflation: when the control units receives start spray set signals via the output module, the light is on. 防盗指示防盗指示:当控制器通过防盗设置,使所挂接的防盗探测器起作用时,该指示灯亮。 Intrusion: when the control units activates the anti-theft detectors through settings, the light is on. 主电工作主电工作:指示主电工作状态,当主电(交流电)正常工作时,该指示灯亮。 AC Power: it indicates the operating status of the main power. When the main power (AC) is normal, the light is on. 主电故障主电故障:当主电短路、断路或欠压以至不能正常工作时,该指示灯亮。 AC Power Fault: when the short/open circuit or undervoltage happens to the main power and results in abnormal states, the light is on. 备电工作备电工作:指示备电工作状态,当备电(蓄电池)工作时,该指示灯亮。 Battery: it indicates the operating status of the standby power. When the standby power (storage battery) is operating, the light is on. 备电故障备电故障:当备电断路时,该指示灯亮。 Battery fault: when the open circuit happens to the standby power, the light is on. 故障故障:当控制器发现有故障时,该指示灯亮。 Fault: when the control units discovers faults, the light is on. 通讯故障通讯故障:当控制器的网络有故障时,该指示灯亮。 Communication fault: when faults happen to the communication between the network of EI-2000G fire alarm control units(linkage type) user manual 8 the control units, the light is on. 自动自动:表示控制器的联动控制方式,当指示灯亮表示控制器自动控制方式,指示灯灭表示处 于手动控制方式。 Auto: it refers to the linkage control mode of the control units. When the light is on, the control units is in the automatic control state. When it is off, the control units is in the manual control state. 自检自检:当控制器正在自检时,该指示灯亮。 Self: when the control units is performing self test, the light is on. 消音消音:当通过消音键使扬声器停止发声时,该指示灯亮。 Silence: when the silence button is pressed and the loudspeaker stops sending sirens, the light is on. 三、数码管说明(三、数码管说明(Segment led instruction) 首报警地址首报警地址:显示首火警的回路、地址信息。 First Alarm Address: display first fire alarm modules loop and address. 时、分时、分:显示系统的时、分信息。 Hour, Minute: display system hour and minute. 后续报警地址后续报警地址:显示后续火警,或预警、监管、故障的回路、地址信息,信息最多为 999 条。 Later Alarm Address: display nest fire, or warning, supervise, fault modules loop and address. The most display number is 999. 报警总数报警总数:显示当前的报警总数量。 Total Of Alarm: display current alarm total number. 启动地址启动地址:显示正在启动的输出模块的回路、地址信息,信息最多为 999 条。 Startup Address: display output modules loop, address which is starting. The most display number is 999. 启动总数启动总数:显示系统中所有启动的总数量。 Total Of Start: display the startup total number. 四、液晶显示信息说明四、液晶显示信息说明(LCD displaying information) 液晶显示的信息包括:火警、系统故障、部件故障、联动信息、菜单及各种提示信息。 LCD displays the following information: fire/theft/combustible gas alarms, precautions, system/component faults, linkage, menus and all kinds of tips. 系统在运行过程中,当在 1 分钟内无按键操作,且系统正常运行,或 5 钟内无新的报警及联 动信息时,液晶屏将关闭背光。当用户按任意键或有新的报警或联动信息显示时,液晶屏背光重 新打开。 In the operating process, the LCD will shut down automatically when there is no button pressing or new alarm/linkage information within five minutes. If this happens in the menu operation state, the system will exit from this state automatically. When the user presses any button or there is new alarm/linkage information, the LCD will be activated again. 1.当系统运行正常时,液晶显示如图 3 所示界面。 When the system is operating well, the LCD has an interface displayed in figure 3。 EI-2000G fire alarm control units(linkage type) user manual 9 Figure 3 LCD display when the system is normal 2.当无菜单操作时,液晶分为报警和联动两个窗口,窗口间由横线分割。可通过“F1”键切换 活动窗口。 When there is no menu operation, the LCD is divided into two windows. Their boundary is marked by a horizontal line. You can select an active window via the F1 key. 3报警窗口说明(alarm window information): 1/1 1B1L1001R SMOKE DETECTOR 13:04 FIRE 1/2 1B1L1002R SMOKE DETECTOR 13:04 FIRE 1/3 1B1L1003R SMOKE DETECTOR 13:04 FIRE 1/9 1B1L1009R OUTPUT MODULE 13:04 FEEDBACK 1/10 1B1L1010R OUTPUT MODULE 13:04 FEEDBACK 1/11 1B1L1011R OUTPUT MODULE 13:04 FEEDBACK Figure 4 LCD information when no menu operation 窗口一位于屏幕上方,显示“报警故障信息” ,主要显示火警、盗警、故障及可燃气报警信 息。当有报警信息时,屏幕不显示当前故障信息,但可通过菜单查询。窗口显示信息可通过翻页 键进行浏览。窗口一显示的最大信息数为 255 条。 Window one is on the top of the screen, displaying alarms/faults including fire/theft/combustible gas alarms and faults. When alarms come, the screen will not display faults, but you can search for them through the menu. You can turn to the next page and browse the information by pressing the Page Down button. Window one can hold 255 (maximum) items of information. 窗口二位于屏幕下方,显示“联动动作信息” ,主要显示设备当前的动作信息。当启动信号 已发到控制模块,则显示该模块“正在启动” ,当该模块有反馈信号时,则显示该模块“有反馈” 。 当有模块正在延时时,则显示“正在延时” 。窗口二显示的最大信息数为 255 条。 normal! Jun.10,2011 15:30:28 EI-2000G fire alarm control units(linkage type) user manual 10 Window two is on the bottom of the screen, displaying linkage action information, which mainly includes the current action actions of devices. When the start signal arrives at the control module, the window will display that the module is starting. When it receives feedback signals, the window will display that module Feedback. If the module is in the delay state, the window will display is delaying. Window two can hold 255 items of information at most. 3.当进行菜单操作时,液晶分为三个窗口,窗口间由横线分割,由上往下依次为窗口一、窗口 二和窗口三,可通过“F1”键切换活动窗口。 When used for menu operation, the LCD is divided into three windows and their boundaries are marked by horizontal lines. From the top to the bottom, there is window one, two, three. You can switch active window via the F1 key. EI-2000G fire alarm control units(linkage type) user manual 11 第六章第六章 系统正常运行状态系统正常运行状态 Chapter 6 Normal states 系统开始运行后,先进行自检。此时,面板上除自检灯点亮外,其余各状态灯均熄灭。自检 过程按:液晶、声音、RAM、FLASH、主键盘、状态灯顺序自检。 Before the system starts operating, it performs self-test. All status indicator lamps are off except for the self-test lamp. The self-test order is: LCD, sound, RAM, FLASH, main keyboard, state lights. 自检开始后,液晶先全亮,再全灭。然后,液晶显示软件版本、配置信息。 When the self-test begins, the LCD is lit first and then blackens. After that the LCD displays information about software versions and settings. 系统自检结束后,自检灯灭,系统进入正常运行状态,此时液晶显示如图 3 示。 When the self-test is done, the self-test light goes out and the system enters the normal running state. The LCD displaying information is as shown in figure 3. EI-2000G fire alarm control units(linkage type) user manual 12 第七章第七章 菜单结构菜单结构 Chapter 7 Menu structure 系统菜单由:系统设置、系统查询、联动控制、打印四个子菜单组成。各子菜单的基本功能 如下: The system menu has four sub-menus: the system setting, system query, linkage control and print. Their principal functions are as follows: 1.1.系统设置子菜单系统设置子菜单( (System setting sub-menu) 完成系统各种配置和状态的设置及修改工作。 Implementing system configurations and status setting/modification. Level oneLevel twoLevel three SET TIME AUTO PRINT BY ADDRESS ALL FAULT BY TYPE SET FIRE BY ADDRESS CANCEL ALL ISOLATION CANCEL BY TYPE SET PASSWORDUSER PASSWORD 2系统查询子菜单系统查询子菜单( (System query sub-menu) 完成系统当前报警信息及编址部件编程信息的查询工作。 Searching for existing alarm information and programs for addressable Components. Level oneLevel twoLevel three FIRE FEEDBACK FAULT ISOLATE SUPERVISE CURRENT INFO WARNING LOOP TOTAL SYSTEM INFO SYSTEM TOTAL BY ADDRESS PART BY LAYER SMOKE DETECTOR DETECTOR HEAT DETECTOR MANUAL BUTTON ALARM BUTTON HYDRANT BUTTON INPUT MODULE MODULE IN-OUT MODULE IN-OUT MODULE LINKAGE KEY 3.联动控制子菜单联动控制子菜单(Linkage control sub-menu) EI-2000G fire alarm control units(linkage type) user manual 13 完成系统中各种联动控制设备的启动和停止操作。 Used to start/stop the linkage control equipment in the system. Level oneLevel two BY ZONE STARTUP BY ADDRESS BY ZONE STOP BY ADDRESS 3.打印控制子菜单打印控制子菜单(Print sub-menu) 完成当前报警信息的打印操作。 Used to print current alarm infomation in the system. Level oneLevel two FIRE SUPERVISE FEEDBACK FAULT WARNING CURRENT INFO ISOLATE STOP PRINT EI-2000G fire alarm control units(linkage type) user manual 14 第八章第八章菜单操作菜单操作 Chapter 8 Menu operation 系统正常运行后,当按下菜单键时,液晶弹出菜单操作窗口,进入菜单操作必须先键入操作 口令,其界面如图 5 所示(省略了窗口 1 和窗口 2,下同) 。 When the system is ready to receive commands, press the menu button and the menu operation window will pop out on the LCD. You must enter the operation password before operating in the menu window. The password interface is shown in figure 5.(inactive window one and two are not shown; same with the following figures). Figure 5 input the password 在口令输入过程中按退出键时,系统将退出菜单操作。口令输入完成按确认键后,系统将对 输入的口令进行校验,当输入的操作口令错误时,则退出菜单操作;口令正确,系统弹出主菜单, 如图 6 所示。 When you input the password, pressing esc will enable the system to exit from the menu operation. Once you have input the password and clicked enter, the system will check the password. If it is wrong, the system will exit from the menu operation. If right, the system will pop out the main menu, as shown in figure 6. Figure 6 main menu 键:为光标条上移; 键:为光标条下移。 key:Cursor up ; . key: Cursor down. 返回和确认键与键盘上的返回和确认键功能相同,返回键为返回上一级操作,确认键为选中 当前菜单。 Back and Enter have the same functions with those on the main keyboard. Back means return to the upper level and Enter is selecting the existing menu. 一、系统设置子菜单操作一、系统设置子菜单操作(System setting sub-menu) INPUT PASSWORD: A B C D E F WIN3 SEL INPUT DEL ENTER MAIN MENU CONFIG CONTROL QUERY PRINT WIN3 BACK ENTER EI-2000G fire alarm control units(linkage type) user manual 15 1.1 设置时钟设置时钟(Clock setting) 当进入设置时钟菜单时,屏幕显示系统当前的月份-日期-年份和小时:分钟:秒钟,光标停留 在月份的位置。按、键,可移动当前光标的位置;TAB 键可以快速移动光标,按键盘 19 键,可修改当前光标所在位置的时间或日期;当按返回键或输入的时间或日期错误时,当前修改 无效;当按确认键时,系统完成时钟设置,并返回到上级菜单。 In the clock setting menu, the screen displays the date (Month/Day/Year) and time (Hour/Minute/Second) in the system. The cursor is at the place of month. Press . and . to move the cursor; you can move the cursor faster via the TAB key. Number 19 can used to modify the time or date at the cursor. When Back is pressed or the input time/date is erroneous, the modification fails. Press Enter and complete the clock setting, then the screen retreat to the upper menu. 1.2 自动打印自动打印(Auto Print) 屏幕显示自动打印选项,各选项可同时选择(选择打印时,用【F4】键将“关”修改为“开” ) 。 When Auto Print menu is selected, the screen display auto print option, every option can be selected at the same time(switch ON-OFF by F4 key) 。 1.3 屏蔽设置屏蔽设置(Isolate Set) 当选中屏蔽设置的屏蔽当前故障屏蔽当前故障菜单时,系统将当前有故障的所有部件全部屏蔽。 When the isolate all fault command in the component isolation menu is selected, the system will isolate all faulty components. 当选中屏蔽设置的屏蔽当前火警屏蔽当前火警菜单时,系统将当前有火警的所有部件全部屏蔽。 When the isolate fire command in the component isolation menu is selected, the system will isolate all fire components. 当选中屏蔽设置的按类型屏蔽按类型屏蔽菜单时,系统将当前有火警的所有部件全部屏蔽。 When the isolate by type command in the component isolation menu is selected, the system will isolate the selected type components. 当选中屏蔽设置的按回路地址按回路地址菜单时,输入 XX 回路,XXX 地址到 XXX 地址,则把此范围 内的所有部件全部屏蔽。当需屏蔽某一个部件时,需将前后地址设置相同或只输入前一个地址。 When the isolate by adderss command in the component isolation menu is selected, need input XX loop, XX address - XX address, and the system will isolate all components in this range. If want isolate one component , require the two adderss is same or input first adderss only. 当选中屏蔽取消屏蔽取消菜单时,系统将按照回路/地址、按类型和全部取消三种方式进行屏蔽取消, 操作方式同部件屏蔽设置。 When the cancel isolation command in the component isolation menu is selected, the system will cancel isolation by loop/address ,by type or by all. The operations are the same as those in component isolation. 1.4 口令设置口令设置(Password setting) 进行口令设置时,设置新口令。新口令键入后,还需确认一次,两次键入口令相同后设置有 效。 To set a password, you need to reenter
温馨提示
- 1. 本站所有资源如无特殊说明,都需要本地电脑安装OFFICE2007和PDF阅读器。图纸软件为CAD,CAXA,PROE,UG,SolidWorks等.压缩文件请下载最新的WinRAR软件解压。
- 2. 本站的文档不包含任何第三方提供的附件图纸等,如果需要附件,请联系上传者。文件的所有权益归上传用户所有。
- 3. 本站RAR压缩包中若带图纸,网页内容里面会有图纸预览,若没有图纸预览就没有图纸。
- 4. 未经权益所有人同意不得将文件中的内容挪作商业或盈利用途。
- 5. 人人文库网仅提供信息存储空间,仅对用户上传内容的表现方式做保护处理,对用户上传分享的文档内容本身不做任何修改或编辑,并不能对任何下载内容负责。
- 6. 下载文件中如有侵权或不适当内容,请与我们联系,我们立即纠正。
- 7. 本站不保证下载资源的准确性、安全性和完整性, 同时也不承担用户因使用这些下载资源对自己和他人造成任何形式的伤害或损失。
最新文档
- 公司物流竞赛活动方案
- 2025年文化产业管理专业研究生入学考试试卷及答案
- 2025年健康促进师职业资格考试试卷及答案
- 2025年家庭教育与青少年发展考试卷及答案
- 2025年教师资格考试试卷及答案学习要点明确
- 与健康同行与心灵相约户外活动
- 训战培训总结
- 护理人员心理支持
- 两个小时的培训
- 造口病人并发症的护理
- 急性髓系白血病诊断治疗规范经典实用课件
- 学院财务处查阅档案申请表
- 铸铁闸门及启闭机安装说明及操作手册
- 过敏性休克的急救及处理流程教材课件(28张)
- 物理发泡绝缘的生产与应用课件
- 北交所评测20题及答案
- 《消防安全技术实务》课本完整版
- CLSI EP25-A 稳定性考察研究
- SJG 44-2018 深圳市公共建筑节能设计规范-高清现行
- 职工子女暑期工会爱心托管班的方案通知
- (5年高职)客户服务实务(第二版)教学课件全套电子教案汇总整本书课件最全教学教程完整版教案(最新)
评论
0/150
提交评论