Flexi设备知识培训_第1页
Flexi设备知识培训_第2页
Flexi设备知识培训_第3页
Flexi设备知识培训_第4页
Flexi设备知识培训_第5页
已阅读5页,还剩64页未读 继续免费阅读

下载本文档

版权说明:本文档由用户提供并上传,收益归属内容提供方,若内容存在侵权,请进行举报或认领

文档简介

Flexi BSC结构与功能 1 TCSM 功能和结构 2 Flexi EDGE BTS介绍 3 1 2nd BSC generation Large Capacity SW up to 256 TRX (S6) with 2 racks 660 TRXs with 1-cabinet BSC3i 660 configuration (S10.5) 1000 TRX with 1-cabinet and up to 2000 TRXs with 2 cabinets by BSC3i 1000/2000 (S12 & S13) 3000 TRX with 1-cabinet by Flexi BSC (BSC3i Flexi) (S14) Complete solution for future CS and PS traffic handling capacity requirements with IP connectivity High Capacity BSC along with smooth upgrade path (S8) Capacity increase up to 512 TRX with 2 racks 1991 1995 1999 2002 BSC3i BSC2i BSCE First BSC generation Up to 128 TRX with 2 high racks BSC2 2007 2009 第一代产品 第二代产品 第三代产品 2 连接能力 / TRXs 电路域 / 话音 分组域 / 数据 传输能力 - E1/T1 - STM-1/OC-3 - IP Transcoding / channels 660 TRXs 4 000 Erl 6 140 x 16 kbit/s CHs 256 E1 / T1 lines - 4 GE links for Gb, O&M, Lb, Sigtran, DFCA 960 channels with TCSM2 参数 BSC3i 660 3 000 TRXs 18 000 Erl 30 720 x 16 kbit/s CHs 800 E1 / T1 lines 16 STM-1/OC-3 12 GE links including also Abis and A i/f 34 000 channels with TCSM3is Flexi BSC (BSC3i3000) 2 000 TRXs 12 000 Erl 25 600 x 16 kbit/s CHs 800 E1 / T1 lines 16 STM-1/OC-3 8 GE links for Gb, O&M, Lb, Sigtran, DFCA 11 520 channels with TCSM3i BSC3i 1000/2000 Flexi BSC 家族 3 Flexi BSC eBSC BSC3i2000 机架尺寸 (高 *宽 *深) 2000mm*900mm*600mm 2000mm*600mm*450mm 2*(2000mm*900mm*600mm) 最多载频数 TRX 3000 2000 2000 最多小区数 3000 1000 2000 最多基站数 Sites 3000 500 2000 PCM Lines 800 E1 288 E1 800 E1 SDH/Sonet Connectivity 16 + 16* STM-1/OC-3 8 + 8* STM-1/OC-3 16 + 16* STM-1/OC-3 IP connectivity 12 + 12* Giga-Ethernet 4 + 4* Giga-Ethernet (RG20) 12 + 12* Giga-Ethernet (改造后) Erlang 18000 10000 12000 E-GPRS Channels (16 Kb/s) 30720 8500 25600 每载频功耗(瓦) 0.7 W (正常情况) 1.3 W (正常情况) 30720 Abis channels / Flexi PCU2-E PIU BTS Objects TRX Objects Abis Channels Up to 30 x 384 Up to 30 x 1,024 Up to 30 x 1,024 PCU2-E Capacity 21 OMU( Operation and Maintenance Unit)是 BSC与高一级网络管理系统和用户之间的一个接口,它可以进行 BSC本地操作和维护。 OMU从 BSC接收故障指示后,向用户提供本地告警打印输出或向网管系统发送故障指示。系统故障时, OMU在 BSC内自动激活适当的恢复和诊断流程。 提供用于本地操作的 I/O接口 OMU主要执行下述功能 : 测量报告管理 BSC维护管理 BSC系统配置和状态管理 BSS系统管理 LAN 拓扑结构管理 OMU OMU Plug-in units CP816-AC AS7-D HWAT-B SERO-B PSC6-AB Mass memory adapter: DCAR1-A 22 提供 USB接口 USB存储设备提供可靠的软件和数据库备份 可支持 4GB的移动设备 包含 2个硬盘( HSD07 ): 互为镜像保持高的安全性。 可以不中断业务进行升级和改变 每个硬盘的容量是 73 GB 指示灯 : 绿色 正常 红色 故障 Hard disk AMC front panel (HDSAM-A) Red - out of Service green Power good Blue Hot Swap amber hard disk drve activity 23 Flexi BSC cabinet LANU GSW2KB GTIC CLOC ETC ETC ETC LANU LANU GTIC GSWB CLOC ETC ETC GTIC GSWB CLOC 24 通过 BSC传送业务; 需要连接信令单元和内部数据传输单元 背板上通过 ET1提供 8Mbit/s连接; 前板通过 ETS2/ETIP提供 2 HotLinks/SW256连接; 负责 BSC的子复用功能。 GSW2KB的特性包括: 2048条 real PCM 16384条 virtual PCM 基于 8kbit/s的水平交换 一个 GSW256B最多 65536个 8kbit/s信道 8个 SW256B Configuration includes 8 x SW256B plug-in units 25 时钟单元 CLS在 BSC中的功能是接受上一级传过来的外接时钟参考,也向 BSC中的各个单元提供时钟信号; 自身也能产生标准时钟信号 收集各个单元的告警上传至 OMU中。 ( CL3TG-UA)插板单元位于SGC1C-A插框中,通过交换能产生基本的时钟信号,从接收到的ET或外部 FS中同步帧对齐信号。 具体的同步信号输入包含连接面板上的 4个 ET和 2个外部输入 FS。 CLS面板上共 3个灯: 1灯亮, 2M1; 2灯亮: 2M2 3: 2M4; 1&2: 2M3; 1&3: FS1; 2&3: FS2 2 x CL3TG units (2N redundancy) 26 LANU- 0 & 1 ETC 0-4 and GTIC 0-1 LANU单元包含 3个 ESB24插板,有两个功能 : 第二槽道上的 ESB板连接各个计算机单元的 CPU板,提供以太网接口,并同时可以连接到网管端( CE交换机上),实现网管对 BSC的监管和操作; 它的三四槽道上的 ESB板,连接 BCSU上的 PCU板,并连接到SGSN端,实现 Gb over IP。 ESB24 单板共提供 24个端口 : - Port 1, 2, 23 和 24 在前面板 . - Port 3 到 22 在备板上 . 27 IP backbone BSC units 28 提供 BSC的外部连接线,包括 2M电路、 SDH和以太网,根据不同的插板实现。 每个 ETS2单板可容纳 2根光纤。 FlexiBSC最大可包含 2*8个 ETS2并提供 16个外部接(光)口。 12个 EET口? ETS2和 ET16可以交替在GTIC框中使用。 ETIP和 ET16可以交替在GTIC框中使用。 0 - 16 x ETS2 units 0 - 16 x ETIP1-A units 0 - 16 x ET16 units 29 ETC 0-4 GTIC 0-1 ETC 0-4 and GTIC 0-1 提供 BSC的外部 PCM线连接。 每个 ET16 可提供 16条 PCMs (E1/T1) Flexi BSC 最大可容纳 50个 ET16 提供 800个外部 PCMs (E1/T1)接口。 30 新的插板 : ETIP1-A for EET interface PCU2-E for Packet data PSC6-D for power supply in each ESB24-A for ethernet switch SWPRO-C for controlling GSWB 公用部分 : FTRB-A enhanced fan units CP816-A CPU for all computer units Bit based group switch for 2048 PCMs (GSW2KB) ET16 for E1/T1 interface ETS2 for STM-1 or OC-3 interface DCAR-A for mass memory LANU Ethernet Message Bus (EMB) MCMU 1 OMU Flexi BSC cabinet MCMU 0 BCSU 0 BCSU 1 BCSU 3 BCSU 5 LANU 0 BCSU 2 BCSU 4 BCSU 6 LANU 1 GTIC 1 GSWB 1 ETC 1 ETC 3 CLS 1 GTIC 0 GSWB 0 ETC 0 ETC 2 CLS 0 31 #TRX per BSC 1500 5011,000 1,0011,500 1,5012,000 2,0012,500 2,5013,000 #active BCSU 1 2 3 4 5 6 Max. #BTS / #BCF 500 1,000 1,500 2,000 2,500 3,000 Max. #logical PCU2-E 5 10 15 20 25 30 Max. #PS Abis chan16 5,120 10,240 15,360 20,480 25,600 30,720 Max. #RTSL 4,000 8,000 12,000 16,000 20,000 24,000 Max. #SS7 links 64 kbps 128 kbps 256 kbps 512 kbps 1024 kbps HSL (2M) Additionally Sigtran (SS7 over IP) 8 4 2 2 1 2 16 8 4 4 2 4 16 12 6 6 3 6 16 16 8 8 4 8 16 16 10 10 5 10 16 16 12 12 6 12 Max. #LAPD 992 1,984 2,976 3,968 4,960 5,952 #Transmission PCM (ET16) STM-1/OC-3 (ETS2) IP/PWE (ETIP1) 50 16 8 50 16 8 50 16 8 50 16 8 50 16 8 50 16 8 PDFU 0 PDFU-B PDFU 1 PDFU-B BCSU 3 BCSU 1 BCSU 5 BCSU 4 BCSU 2 BCSU 6 FTRB 1 FTRB 0 CLS 1 GSW2KB 1 OMU BCSU 0 MCMU 0 MCMU 1 GSW2KB 0 GTIC 1 GTIC 0 CLS 0 ETC 0 ETC 1 ETC 2 ETC 3 LANU 0 LANU 1 2000 x 900 x 600 cabinet FTRB 3 FTRB 2 1 3 5 4 6 2 32 Flexi BSC结构与功能 1 TCSM 功能和结构 2 Flexi EDGE BTS介绍 3 33 Up to 960 ETSI / 768 ANSI Ch Extension Step 120 ETSI / 95 ANSI Added unique features for superior voice quality such as Acoustic Echo Canceller and Noise Supression Third generation from 1995 from 2006 Second generation TCSM3i TCSM2E/A First generation Up to 450 ETSI Ch Extension Step 15 ETSI from 1992 BB20382EA1SMHWLK2MLK2MLK2MDB2MDX2MTRC15TRC15DB2MDX2MTRC15TRC15DB2MDX2MTRC15TRC15SM2M(or TRCU) TRCU TRCU TRCUBB20382EA1SMHWLK2MLK2MLK2MDB2MDX2MTRC15TRC15DB2MDX2MTRC15TRC15DB2MDX2MTRC15TRC15SM2M(or TRCU) TRCU TRCU TRCUBB20382EA1SMHWLK2MLK2MLK2MDB2MDX2MTRC15TRC15DB2MDX2MTRC15TRC15DB2MDX2MTRC15TRC15SM2M(or TRCU) TRCU TRCU TRCUBB20382EA1SMHWLK2MLK2MLK2MDB2MDX2MTRC15TRC15DB2MDX2MTRC15TRC15DB2MDX2MTRC15TRC15SM2M(or TRCU) TRCU TRCU TRCUBB20382EA1SMHWLK2MLK2MLK2MDB2MDX2MTRC15TRC15DB2MDX2MTRC15TRC15DB2MDX2MTRC15TRC15SM2M(or TRCU) TRCU TRCU TRCUTCSME Up to 11520 ETSI / 9120 ANSI Ch Extension Step 960 ETSI / 760 ANSI All TCSM2 features available Added enhanced pool options 34 容量大,结构紧凑,单机柜支持超过11 000 个业务信道 ( 384 A接口) 机柜数少,耗电量低,运维成本低 支持新的和 BSC3i 1000/2000的组合安装方式,具有如下优势 : 提供到 A接口和远端 BSC的SDH/Sonet的光纤传输方式 几个 BSC(包括本地和远端的 BSC)可共享 TCSM3i 的容量 统一的电路池( All-in-one pool)简化了对电路池配置的工作 35 T C S M 3 i s o f t w a r eS u p p o r t e d c o d e c s a n d f e a t u r e sS u p p o r t e d A - i n t e r f a c e p o o l s T y p e i n T C S M 3 i1 ( F R )3 ( D R )5 ( E F R & F R )7 ( E F R & D R )2 0 ( E F R & D R & D 1 4 4 )2 3 ( A M R )2 8 ( E F R & D R & A M R & D 1 4 4 )1 0 ( H S 2 )2 1 ( H S 2 & D 1 4 4 )1 3 ( H S 4 ) 2 2 ( H S 4 & D 1 4 4 )3 2 ( E F R & D R & A M R & H S 4 & D 1 4 4 )T 5 5 _ P X M X F R , H R , E F R , A M R , A E C , T F O , N S , 1 4 . 4 D , H S C S D , T T YGHINEW All-in-one Circuit Pools pool 28 and 32 TCSM3i does not support pool2 (8Kbit/s submultiplexing) T C S M 2 s o f t w a r eS u p p o r t e d c o d e c s a n d f e a t u r e sS u p p o r t e d A -i n t e r f a c e p o o l sT y p e i n T C S M 23 ( D R )7 ( E F R & D R )2 0 ( E F R & D R & D 1 4 4 )1 0 ( H S 2 )2 1 ( H S 2 & D 1 4 4 )1 3 ( H S 4 ) 2 2 ( H S 4 & D 1 4 4 )1 ( F R ) A5 ( E F R & F R ) AT D 2 _ P X M X H R , A E C , T F O , N S 2 ( H R ) BT D 3 _ P X M X A M R , A E C , N S 2 3 ( A M R ) F3 ( D R )7 ( E F R & D R )2 0 ( E F R & D R & D 1 4 4 )1 0 ( H S 2 )2 1 ( H S 2 & D 1 4 4 )1 3 ( H S 4 ) 2 2 ( H S 4 & D 1 4 4 )1 ( F R ) A5 ( E F R & F R ) AT D 6 _ P X M X A M R , A E C , T T Y 2 3 ( A M R ) FT D L _ P X M X F R , H R , E F R , A E C , N S , 1 4 . 4 D , H S C S DCDET D 1 _ P X M X F R , E F R , A E C , T F O , N S , 1 4 . 4 DT D 4 _ P X M X F R , H R , E F R , A E C , 1 4 . 4 D , H S C S D , T T YCDET D 5 _ P X M X F R , E F R , A E C , T F O , T T Y , 1 4 . 4 D36 Combi TCSM3i Stand-alone TCSM3i Fan tray Fan tray PDFU PDFU Fan tray Fan tray TCSM TCSM TCSM TCSM TCSM TCSM ET ET ET CLS Air Guide Fan tray Fan tray PDFU PDFU Fan tray Fan tray TCSM TCSM TCSM TCSM TCSM TCSM SET SET CLAB Air Guide FlexiBSC TCSM3i 37 Combi TCSM3i Stand-alone TCSM3i 相同点 同样的机架 (M98 Mechanics, IC-209-B cabinet) 同样的 TR3E完成编码和子复用功能 每机柜最大的TCSMs单元数都为96. 同一机柜都可以服务于多个 BSC。 Fan tray Fan tray PDFU PDFU Fan tray Fan tray TCSM TCSM TCSM TCSM TCSM TCSM ET ET ET CLS Air Guide Fan tray Fan tray PDFU Fan tray Fan tray TCSM TCSM TCSM TCSM TCSM TCSM SET SET CLAB Air Guide 38 Combi TCSM3i Stand-alone TCSM3i Fan tray Fan tray PDFU PDFU Fan tray Fan tray TCSM TCSM TCSM TCSM TCSM TCSM ET ET ET CLS Air Guide Fan tray Fan tray PDFU Fan tray Fan tray TCSM TCSM TCSM TCSM TCSM TCSM SET SET CLAB Air Guide 不同点 Combi TCSM3i 不需要配线框 . combi TCSM3i 使用CLAB而 Stand-alone使用 CL3TG. combi TCSM3i配置SBMUX和 ETS2, Stand-alone使用 ET16. TCSM框 Combi TCSM3i 不需要 ET16. 处理话务能力不同。 39 1 2 3 4 5 ETC0 ETC1 ETC2 6 7 8 9 10 11 12 13 14 15 16 1_2_3_4_5_6_7_8 17 18 19 20 21 22 23 24 1_2_3_4_5_6_7_8 1_2_3_4_5_6_7_8 Subrack Level 1 40 1 1 2 3 4 1,2,3,4,5,6,7,8,9,10,11,12,13,14,15,16 2 3 4 1,2,3,4,5,6,7,8 9,10,11,12,13,14,15,16 Only 1 BSC can be connected because of 1 Ater ET piu 2 BSCs can be connected because there are 2 ATER pius 5 6 7 8 5 ETC0 ETC1 ETC2 TC2C-0 TC2C-1 1_2_3_4_5_6_7_8 Indexes 6 0_1_2_3 4_5_6_7 8_9_10_11 12_13_14_15 0_1_2_3 7 4_5_6_7 8_9_10_11 12_13_14_15 8 1_2_3_4_5_6_7_8 1_2_3_4_5_6_7_8 Subrack Level 1 Subrack Level 2 41 9 10 11 12 1,2,3,4,5,6,7,8,9,10,11,12,13,14,15,16 1,2,3,4,5,6,7,8 9,10,11,12,13,14,15,16 Only 1 BSC can be connected because of 1 Ater ET piu 2 BSCs can be connected because there are 2 ATER pius 13 14 15 16 ETC0 ETC1 ETC2 TC2C-2 TC2C-3 Indexes 0_1_2_3 4_5_6_7 8_9_10_11 12_13_14_15 0_1_2_3 4_5_6_7 8_9_10_11 12_13_14_15 9 10 11 12 13 14 15 16 1_2_3_4_5_6_7_8 1_2_3_4_5_6_7_8 1_2_3_4_5_6_7_8 Subrack Level 1 Subrack Level 4 42 17 18 19 20 1,2,3,4,5,6,7,8,9,10,11,12,13,14,15,16 1,2,3,4,5,6,7,8 9,10,11,12,13,14,15,16 Only 1 BSC can be connected because of 1 Ater ET piu 2 BSCs can be connected because there are 2 ATER pius 21 22 23 24 ETC0 ETC1 ETC2 TC2C-4 TC2C-5 Indexes 0_1_2_3 4_5_6_7 8_9_10_11 12_13_14_15 0_1_2_3 4_5_6_7 8_9_10_11 12_13_14_15 1_2_3_4_5_6_7_8 17 18 19 20 21 22 23 24 1_2_3_4_5_6_7_8 1_2_3_4_5_6_7_8 Subrack Level 1 Subrack Level 5 43 Cabinet Head master TR3E/A Cabinet clock supervision ( O&M for CL3TG) Located at track 1 TR3E/A ( first TR3E/A is track 0 ) Cartridge master TR3E/A Ater interface ET16E/A supervision ( O&M) Located at track 0 TR3E/A in Cartridge and track 8 if 2nd Ater ET16 is used Master TR3E/A A interface ET16E/A supervision ( O&M) Located at track 0,4,8,12 TR3E/A in Cartridge Track 0 TR3E/A handles O&M for the A & Ater interface s ET16 (cartridge master) Normal TR3E/A TR3E/A in other locations 44 ETC2 1_2_3_4_5_6_7_8 ETC1 1_2_3_4_5_6_7_8 ETC0 1_2_3_4_5_6_7_8 TC2C-0 1_2_3_4_5_6_7_8_9_10_11_12_13_14_15_16_17 TC2C-1 1_2_3_4_5_6_7_8_9_10_11_12_13_14_15_16_17_18 CLS Only in track 1 of the TC2C-0 Cartridge Clock LAPD for O&M for clock supervision 45 ETC2 1_2_3_4_5_6_7_8 ETC1 1_2_3_4_5_6_7_8 ETC0 1_2_3_4_5_6_7_8 1,2,3,4,5,6,7,8,9,10,11,12,13,14,15,16 TC2C-0 1_2_3_4_5_6_7_8_9_10_11_12_13_14_15_16_17 9,10,11,12,13,14,15,16 1,2,3,4,5,6,7,8 TC2C-1 1_2_3_4_5_6_7_8_9_10_11_12_13_14_15_16_17_18 Ater-IF In track 0 of every TC2C Cartridge and track 8 if 2nd Ater ET16 is used ETLAPD of Ater-IF for ET supervision (O&M) 46 3 ETC2 7 1_2_3_4_5_6_7_8 2 ETC1 4 6 8 1_2_3_4_5_6_7_8 1 ETC0 5 1_2_3_4_5_6_7_8 1 2 3 4 1,2,3,4,5,6,7,8,9,10,11,12,13,14,15,16 TC2C-0 1_2_3_4_5_6_7_8_9_10_11_12_13_14_15_16_17 9,10,11,12,13,14,15,16 5 6 7 8 1,2,3,4,5,6,7,8 TC2C-1 1_2_3_4_5_6_7_8_9_10_11_12_13_14_15_16_17_18 A-IF Track 0 TR3E/A handles O&M for the A&Ater IF ET16 (cartridge master) In track 0,4,8,12 of every TC2C Cartridge ETLAPD of A-IF for ET supervision (O&M) . .47 FlexiBSC对 TCSM3i的 ETS2的控制 PCM是 1714, 1715和 1722, 1723,这四条 PCM与 BCSU中 PCU的内部 PCM重复,必须删除 BCSU-6数据,并将背板后的连线 拆除 使用 FlexiBSC与 TCSM3i Combine安装后, FlexiBSC的实际容量为 2500TRX 现场到货的 TC均为 Standalone配置,需现场将 TC升级至 Combine配置 Equipping CABLE FROM CABLE TO No FU Position FU Position Type Use Note BSCC_123 LANU 0 4.0B 13.1L BCSU 6 5.0B 16.1N CHG018 LAN remove BSCC_271 GSW2KB-A 0 1.0B 07.3L BCSU 6 5.0B 11.1Z CHF023 PCM remove BSCC_272 GSW2KB-A 0 1.0B 07.3C BCSU 6 5.0B 11.1R CHQ023 PCM remove BSCC_273 GSW2KB-A 0 1.0B 07.2U BCSU 6 5.0B 11.1J CHQ024 PCM remove BSCC_274 GSW2KB-A 0 1.0B 07.2M BCSU 6 5.0B 11.1A CHQ024 PCM remove BSCC_153 LANU 1 5.0B 13.1L BCSU 6 5.0B 17.1N CHG007 LAN remove BSCC_371 GSW2KB-A 1 2.0B 07.3L BCSU 6 5.0B 36.3Z CHF022 PCM remove BSCC_372 GSW2

温馨提示

  • 1. 本站所有资源如无特殊说明,都需要本地电脑安装OFFICE2007和PDF阅读器。图纸软件为CAD,CAXA,PROE,UG,SolidWorks等.压缩文件请下载最新的WinRAR软件解压。
  • 2. 本站的文档不包含任何第三方提供的附件图纸等,如果需要附件,请联系上传者。文件的所有权益归上传用户所有。
  • 3. 本站RAR压缩包中若带图纸,网页内容里面会有图纸预览,若没有图纸预览就没有图纸。
  • 4. 未经权益所有人同意不得将文件中的内容挪作商业或盈利用途。
  • 5. 人人文库网仅提供信息存储空间,仅对用户上传内容的表现方式做保护处理,对用户上传分享的文档内容本身不做任何修改或编辑,并不能对任何下载内容负责。
  • 6. 下载文件中如有侵权或不适当内容,请与我们联系,我们立即纠正。
  • 7. 本站不保证下载资源的准确性、安全性和完整性, 同时也不承担用户因使用这些下载资源对自己和他人造成任何形式的伤害或损失。

评论

0/150

提交评论