翻译原文_to.pdf_第1页
翻译原文_to.pdf_第2页
翻译原文_to.pdf_第3页
翻译原文_to.pdf_第4页
翻译原文_to.pdf_第5页
已阅读5页,还剩6页未读 继续免费阅读

翻译原文_to.pdf.pdf 免费下载

版权说明:本文档由用户提供并上传,收益归属内容提供方,若内容存在侵权,请进行举报或认领

文档简介

Evaluating Fire Resistance of Steel Girders in Bridges Venkatesh Kodur F ASCE1 Esam Aziz2 and Mahmud Dwaikat3 Abstract In current practice no special measures are applied for enhancing structural fi re safety of steel bridge girders Further there is very limited information and research data in the literature on the fi re resistance of structural members in bridges In this paper the fi re response of a steel bridge girder under different conditions is evaluated using the FEM computer program ANSYS In the analysis the critical factors that infl uence fi re resistance namely fi re scenario fi re insulation and composite action arising from steel concrete interaction are accounted for Results from numerical studies show that the composite action arising from steel girder concrete slab interaction signifi cantly enhances the structuralperformance andfi reresistance ofasteelbridgegirderunderfi reconditions Othersignifi cantfactorsthatinfl uencefi reresistanceof steel bridge girders are fi re insulation and type of fi re scenario DOI 10 1061 ASCE BE 1943 5592 0000412 2013 American Society of Civil Engineers CE Database subject headings Fires Fire resistance Girder bridges Steel bridges Author keywords Bridge fi res Fire resistance Steel girders FEM analysis Introduction Fire is one of the most severe environmental hazards to which the built infrastructure may be subjected during its lifetime In recent decades due to rapid development of urban ground transportation systems as well as increasing transportation of hazardous ma terials e g fl ammableliquids spontaneouslycombustiblematerials poisonous substances etc bridge fi res have become a growing concern Kodur et al 2010 Whereas the perception may be that it is very unlikely that a bridge will collapse under fi re a recent U S widesurveybytheNewYorkStateDepartmentofTransportation NYDoT has shown that nearly three times more bridges have collapsedinthe1990 2005periodduetofi rethanduetoearthquakes M Garlock personal communication 2008 In some cases bridge fi resmightleadtothecollapseofstructuralmembers leadingtomajor traffi cdelays detours andcostlyrepairs Thefollowingfi reincidents illustrate the magnitude of fi re problem in bridges On July 15 2009 a tanker truck carrying 13 000 gal of fl am mable liquid was involved in an accident with another truck under the 9 mi road overpass over the I 75 expressway near Hazel Park Michigan This bridge consisted of 10 hot rolled steel girders in a 24 m span that supported a RC slab The intense heat from the fi re reached about 1 100 C and this heat led to weakening of the steel girders and resulted in collapse of the overpass as illustrated in Fig 1 This collapse occurred in about 20 min after the start of the fi re It took about 105 min for the fi refi ghters to extinguish the fi re This accident caused millions of dollars of damage Preliminary recommendationscalledforrebuildingtheentire9 mibridgeoverI 75 and the freeway below also needed some level of repair It took severalweeksofdetoursonI 75andseveralmonthsforrepairofthe bridge National Steel Bridge Alliance 2010 Another example of fi re induced bridge collapse is the one that occurred on the MacArthur Maze I 80 880 interchange in Oakland California on April 29 2007 A tanker truck carrying 8 600 gal of gasoline overturned underneath the I 580 expressway which con sisted of six plate girders supporting a RC roadway The fi refi ghters responded to the spot within 14 min but the intense fi re from the accident resulted in temperatures reaching 1 100 C This intense heat lead to loss of strength in the steel girders and ultimately the connections at the supports gave way leading to collapse of two I 580 spans The failure occurred at 22 min into the fi re Preliminary analysis revealed that the failure was due to overstressing of con nections under high temperature effects This incident cost 9 milliontorepairthebridge andtheretrofi ttingtookmonthstofi nish Astaneh Asl et al 2009 The response of bridge structural members under fi re can be different from that of buildings for the following reasons 1 Fire source The common source of ignition in bridges is thecrashingofgasolinetankertrucksandburningofgasoline in the vicinity of the bridge However the common source of ignition in buildings is the burning of combustion ma terials mostly wood and plastic based products in the compartment 2 Fire ventilation Most building fi res are enclosed compart ment fi res and are limited by the amount of ventilation However bridge fi res are generally under open air conditions and have unlimited access to ventilation oxygen 3 Fire severity Bridge fi res can be much more intense than building fi res and are representative of hydrocarbon fi res because the fi re source is generally gasoline 4 Fire protection In contrast to buildings which are provided with active fi re protection systems such as sprinklers and passive fi re protection such as fi re insulation no special fi re protection measures are provided in bridges 5 Failure limit state Bridge girders aremuch deeper thanbeams in buildings and may have quite slender webs As a result 1Professor Dept of Civil and Environmental Engineering Michigan State Univ East Lansing MI 48864 corresponding author E mail kodur egr msu edu 2Ph D Candidate Dept of Civil and Environmental Engineering MichiganStateUniv EastLansing MI48864 E mail azizesam msu edu 3Researcher DelftUniversity 2600AADelft Netherlands formerly Post Doctoral Fellow Dept of Civil and Environmental Engineering Michigan State Univ East Lansing MI 48864 E mail dwaikat1 egr msu edu Note This manuscript was submitted on September 30 2011 approved on April 23 2012 published online on April 26 2012 Discussion period open until December 1 2013 separate discussions must be submitted for individual papers This paper is part of the Journal of Bridge Engineering Vol 18 No 7 July 1 2013 ASCE ISSN 1084 0702 2013 7 633 643 25 00 JOURNAL OF BRIDGE ENGINEERING ASCE JULY 2013 633 J Bridge Eng 2013 18 633 643 Downloaded from ascelibrary org by CENTRAL SOUTH UNIVERSITY on 03 24 14 Copyright ASCE For personal use only all rights reserved shear failure due to web buckling is likely to dominate in bridge girders whereas fl exural failure is the dominant failure mechanism in beams 6 Connections Bridge girders are typically supported through bearing of the bottom fl ange In contrast the connections in buildings are made through the web and or the fl ange These variationsinsupportconditionshaveaneffectontheresulting fi re resistance Paya Zaforteza and Garlock 2010 A review of literature indicates that there is a lack of information on the fi re performance of bridge girders and this is mainly due to the fact that little attention has been paid to structural fi re safety in bridges Thelimitedstudiesonthefi reresistanceofbridgesarethose reported by Dotreppe et al 2006 Kodur et al 2010 and Paya Zaforteza and Garlock 2010 These studies clearly indicate that bridge fi res are a signifi cant problem and typically result from the crashingofvehiclesinthevicinityofthebridge Thetimetofailureis typically less than 30 min and thus very little time is available for fi refi ghters to respond Further there is lack of data on the fi re behavior of bridge girders as well as on the main factors that in fl uence fi re resistance To overcome some of these drawbacks a research project on the fi re performance of steel bridges is currently under way at Michigan State University This paper presents results from a numerical study on the fi re performance of steel bridge girders FEM Model Toillustratetheresponseofasteelgirderexposedtofi re anumerical study was carried out using the FEM computer program ANSYS ANSYS multiphysics 11 0 SP1 This program is capable of han dling coupled and uncoupled thermomechanical problems For the analysis a simply supported steel bridge girder was selected This bridge girder is generally comprised of different structural com ponents namely girder RC slab and intermediate diaphragms Two sets of discretization models were developed for undertaking thermal and mechanical analyses The thermal analysis results are applied as a thermal body load on the structural model uniformly along the girder span High temperature thermal and mechanical properties of steel concrete and insulation were incorporated in the analysis Strengthlimitstatewasadoptedfordefi ningfailure andthe failure is said to occur when the girder is unable to resist the applied load effects Discretization for Thermal Analysis The heat transfer analysis of the selected composite steel concrete girder was carried out for two cases namely with and without stiffeners For the discretization of the girder slab and stiffeners SOLID70elementswereused SOLID70isathree dimensional 3D element with 3D thermal conduction capability and has eight nodes with a single degree of freedom namely temperature at each node This element is applicable to 3D steady state or transient thermal analysis The external surface areas of the SOLID70 elements that are exposed to fi re except the top surface of the slab were used to simulate the surface effects of convection and radiation that occur fromtheambientairtothesteelgirder Thediscretizationadoptedfor the thermal model is shown in Fig 2 The girder slab assembly segment AB shown in Fig 2 b was meshed with SOLID70 elements Both heat convection and radia tion loads were applied at the exposed surface areas of the solid element Convection coeffi cients of ac550W m2 C and ac5 35W m2 C were used in the thermal analysis under hydrocarbon and external fi re respectively and this is based on Eurocode 1 European Committee for Standardization CEN 2002 recom mendations Depending on the exposure boundaries different values of effective emissivity factor were used CEN 2002 An effective emissivity factor of 0 7 was used for the bottom and side surfacesofthebottomfl angeofthegirder Forthesidesurfacesofthe web anemissivityfactorof0 5wasused whereasafactorof0 3was used for the top fl ange and bottom of the slab This variation in emissivityfactoristorefl ectthefactthattheweb topfl ange andslab will experience slightly less radiation due to the effect of the larger girder depth of the girder section A Stefan Boltzmann radiation con stant of 5 6731028W m2 C was applied in the thermal analysis The thermal properties of steel and concrete namely thermal conductivity specifi c heat and thermal expansion vary with Fig 1 Fire inducedgirdercollapseinHazelParkoverpassinMichigan photograph from Zapletal 2009 Fig 2 Three dimensional discretization of girder cross section for thermalanalysis a typicalgirderinabridge b 3DmeshofsegmentAB 634 JOURNAL OF BRIDGE ENGINEERING ASCE JULY 2013 J Bridge Eng 2013 18 633 643 Downloaded from ascelibrary org by CENTRAL SOUTH UNIVERSITY on 03 24 14 Copyright ASCE For personal use only all rights reserved temperature In the analysis the high temperature properties are assumed to follow according to Eurocode 2 CEN 2004 and Eurocode 3 CEN 2005 provisions The temperatures T obtained via FEM analysis were averaged at every time step of fi re exposure by taking the arithmetic mean of the temperatures at several points for each component i e fl ange web or slab portion of the steel girder concrete slab composite section as shown in Fig 3 Discretization for Structural Analysis For structural analysis the bridge girder was modeled with two elements namely element SHELL181 for the bottom fl ange web topfl ange andstiffenersandelementSOLID65fortheconcreteslab SHELL181 has four nodes with six degrees of freedom per node threetranslationsinx y andz directions andthreerotationsabout thex y andz axes Thiselementcancapturebucklingoffl angeand webaswellaslateraltorsionalbucklingofthememberandtherefore iswellsuitedforlarge rotation large strain andnonlinearproblems SOLID65 has eight nodes with three degrees of freedom namely three translations in the x y and z directions This element can be used for 3D modeling of solids with or without reinforcement andis capable of accounting for cracking of concrete in tension crushing ofconcreteincompression creep andlargestrains Theoutputfrom the thermal analysis temperatures was applied as a thermal body load on the structural model to evaluate the mechanical response of a steel concrete composite girder The 3D structural model and the meshing adopted in the analysis are shown in Fig 4 a To account for composite action between the concrete slab and the top fl ange of the steel girder node to node interaction was dis cretizedinthestructuralmodelasshowninFig 4 b The same nodes are shared between the solid elements of the concrete slab and the shell elements of the top fl ange of the steel girder To discretize the boundary condition in the structural FEM model the support con ditions of the bridge girder were applied on multiline nodes at the lower face ofthe bottomfl ange as showninFig 4 c Thisboundary conditionrefl ectsapracticalscenario reducesthestressconcentration attheboundary conditionnodes andimprovestheconvergenceofthe FEM solution Also to consider the continuity effect of the concrete slab the slab was restrained from lateral movement see Fig 4 c Material Properties The progression of temperatures in the steel section under fi re ex posure depends on the fi re scenario and the thermal properties of constituent materials namely thermal conductivity specifi c heat andthermalexpansion whichvaryasafunctionoftemperature The mechanical properties of steel and concrete that are critical for Fig 3 Averaging the temperature in the girder cross section Fig 4 Three dimensional discretization of bridge girder for structural analysis a 3D mesh b composite action simulation c support and boundary condition JOURNAL OF BRIDGE ENGINEERING ASCE JULY 2013 635 J Bridge Eng 2013 18 633 643 Downloaded from ascelibrary org by CENTRAL SOUTH UNIVERSITY on 03 24 14 Copyright ASCE For personal use only all rights reserved fi re resistanceevaluationarestress strainrelationshipsandmodulus of elasticity which also vary with temperature The temperature dependent thermal and mechanical properties of steel and concrete are assumed to follow the Eurocode 2 CEN 2004 and Eurocode 3 CEN 2005 provisions The thermal conductivity specifi c heat thermal expansion and stress strain curves of structural steel and concreteusedintheanalysisaregiveninFigs 5 8 Thefi reinsulation applied on the steel girder is CAFCO 300 and this insulation has a specifi ed thermal conductivity of 0 078 W m C and a density of 240kg m3atroomtemperature IsolatekInternational2008 CAFCO 300 is typically used for interior applications but the thermal properties i e thermalconductivityandspecifi cheat of this type of insulation used in exterior applications are quite similar to those of the insulation used in interior applications The high temperature thermal properties of the insulation both thermal conductivity and specifi c heat were assumed to follow the recommendations of Bentz and Prasad 2007 The temperature dependent thermal conductivity andspecifi c heatvalueoftheinsulationusedintheanalysisisplotted in Fig 9 as a function of temperature Model Validation There is lack of fi re test data on the responses of bridge girders under fi re conditions Therefore validation of the ANSYS model we developed was carried out by selecting a steel beam concrete slab assembly tested by British Steel Corporation British Steel Technical and Swinden Laboratories 1989 This beam slab assembly typical of that in buildings was tested under ISO 834 ISO 1975 fi re exposure The validation process included com parison of both thermal and structural response predictions from the analysis with that reported in the fi re test The steel beam was not insulated The beam slab assembly together with thermocouple layout usedinthetestformeasuringtemperaturesisshowninFig 10 The analysis was carried out with the mesh discretization and high temperature properties discussed earlier The assembly was exposed to ISO 834 fi re exposure as in the fi re test Fig 11showsacomparisonofpredictedsteeltemperaturesbythe FEM model with those measured in the fi re test It can be seen that the top fl ange of the beam experienced much lower temperatures compared with the bottom fl ange and this is due to the effect of the concrete slab which dissipates the temperature in the top fl ange because of the lower thermal conductivity and higher thermal ca pacity of concrete compared with steel The web temperatures are slightly higher than those in the bottom fl ange and this is due to the factthatthethicknessofthewebismuchlessthanthatofthefl anges Overall the predicted temperatures from the analysis compare well with the measured data from the test The slight difference can be attributed to variation in the heat transfer parameters such as emissivity and convection coeffi cients used in the analysis compared with the actual values in the test furnace A comparison of midspan defl ections predicted by the ANSYS model and those measured in the test is shown in Fig 12 It can be seenthat the midspandefl ectiongraduallyincreaseswith timeinthe early stage of the fi re up to 10 min These initial defl ections are Fig 5 Variation in thermal properties as a function of temperature for carbon steel a thermal conductivity b specifi c heat c thermal expansion 636 JOURNAL OF BRIDGE ENGINEERING ASCE JULY 2013 J Bridge Eng 2013 18 633 643 Downloaded from ascelibrary org by CENTRAL SOUTH UNIVERSITY on 03 24 14 Copyright ASCE For personal use only all rights reserved mainly due to high temperature gradients that develop between the topandbottomfl angesofthesteelsectionandtheslightreductionin elastic modulusofsteel resultingfrom increased temperatures in the girder After 10 min the rate of defl ection increases slightly due to spread of plasticity which results in faster strength and stiffness degradation of steel at high temperatures At about 21 min when the bottom fl ange and web temp

温馨提示

  • 1. 本站所有资源如无特殊说明,都需要本地电脑安装OFFICE2007和PDF阅读器。图纸软件为CAD,CAXA,PROE,UG,SolidWorks等.压缩文件请下载最新的WinRAR软件解压。
  • 2. 本站的文档不包含任何第三方提供的附件图纸等,如果需要附件,请联系上传者。文件的所有权益归上传用户所有。
  • 3. 本站RAR压缩包中若带图纸,网页内容里面会有图纸预览,若没有图纸预览就没有图纸。
  • 4. 未经权益所有人同意不得将文件中的内容挪作商业或盈利用途。
  • 5. 人人文库网仅提供信息存储空间,仅对用户上传内容的表现方式做保护处理,对用户上传分享的文档内容本身不做任何修改或编辑,并不能对任何下载内容负责。
  • 6. 下载文件中如有侵权或不适当内容,请与我们联系,我们立即纠正。
  • 7. 本站不保证下载资源的准确性、安全性和完整性, 同时也不承担用户因使用这些下载资源对自己和他人造成任何形式的伤害或损失。

评论

0/150

提交评论