




已阅读5页,还剩39页未读, 继续免费阅读
版权说明:本文档由用户提供并上传,收益归属内容提供方,若内容存在侵权,请进行举报或认领
文档简介
佟楼汉庭快捷酒店配电系统设计 40摘 要配电系统是现代生活的重要组成部分,在现代建筑中占有着非常重要的作用,合理进行配电系统的设计凸显出越发重要的作用。论文将着重介绍佟酒店的配电系统,详细阐述不同用电负荷的供电要求,从供电安全、可靠的角度重点介绍了供电系统、照明系统、动力系统、干线系统、配电室及配电箱的设置、导线选择等,了解酒店建筑相适应的配电系统,满足更安全、可靠的配电设计要求。在该设计中,依据给定的设计范围和基础资料,建立起适合自身需要的供电系统。关键词:照明系统,配电系统,防雷,干线,负荷ABSTRACTThe distribution system is an important part of modern life, in a modern building occupies a very important role, in rational distribution system designed to highlight the increasingly important role. The paper focus on hotel distribution system, and elaborated on the power requirements of the different electricity load from the power supply safe, reliable point of view focuses on the power supply systems, lighting systems, power systems, trunking systems, distribution room and the distribution box set, wire selection, understand the hotel building to adapt to the distribution system to meet the more secure, and reliable power distribution design requirements. In this design, according to the given range of design and basic data to establish a supply system for their own needs.Key words: lighting system, power distribution system, lightning protection , trunk line, load目 录1 绪论.11.1课题背景.11.2工程概述.12 供配电系统设计.32.1相关内容及要求.32.2负荷计算.42.3低压配电系统接线形式.122.4配电设备布置.132.5变电所低压侧电气主接线图.153 照明系统设计.163.1酒店照明系统设计特点.163.2设计原则.173.3配电箱系统图.204 动力及消防系统设计.254.1动力及消防系统介绍.254.2设计原则.264.3系统形式及设备布置.264.4动力及消防相关图纸.275 防雷及接地设计.305.1有关下引线的要求.305.2接地电阻要求.315.3防雷相关计算公式.316 结论.32参考文献 .33 致谢 .34附录 .351 绪论供配电技术是建筑电气的重要组成部分,是连接电力系统与人们生产、生活的纽带,它包括研究照明、通讯、安防等功能,管理水泵、空调通风等建筑设备工作,火灾等紧急状态组织人员疏散和火灾扑救,归根到底,供配电技术,就是研究电力的供应及分配的问题12-13。建筑电气设计主要是依据建设单位提出的设计委托要求和国家设计规范,分析建筑布局与功能,以功能与安全为原则,同时兼顾工程造价、施工难易、管理与维护等因素,合理组织楼内供配电系统及各通讯等弱电系统,是建筑功能与安全设计的核心组成部分1-7。随着社会的快速发展,供配电的相关技术也在不断发展进步。因此,研究这个课题是非常有意义的。1.1 课题背景电力,是现代工业生产、民用住宅、及企事业单位的主要能源和动力,是现代文明的物质技术基础。没有电力,就没有国民经济的现代化。现代社会的信息化和网络化,都是建立在电气化的基础之上的。因此,电力供应如果突然中断,则将对这些用电部门造成严重的和深远的影响。随着社会经济的快速发展与城市化进程的加快,酒店业迎来了全面的发展机遇。人们的众多生活方式,如商务、旅游、休闲、度假等,更令酒店业如同雨后春笋般得到了迅猛发展。越来越多的不同品牌与级别的酒店建筑应运而生。如何进行酒店建筑的电气设计,特别是供配电系统设计,使其与酒店的品牌、级别、规模等相适应,正逐步成为一个重要的研究课题。经济的快速发展,促使酒店建筑层数越来越高,建筑面积越来越大,人们对酒店建筑的功能要求更丰富,建筑内部设备越来越丰富,这无疑对建筑电气提出了更高的要求,特别是供配电方面。如供电半径大,用电功率高,对公共通道照明、电梯、消防水泵、排烟风机等重要负荷要求不间断供电。要求酒店建筑具有电话、电视、广播、计算机网络等通讯系统满足生活和工作的需求,要求配备门禁监视、安全防范、自动消防灭火及消防联动等系统满足安全的要求,酒店建筑物防雷随着建筑高度的增加更显得重要。以上的这些都对酒店供配电系统方面提出了严峻的考验。因此,如何合理的设计酒店供配电系统显得尤为重要。论文将结合佟楼汉庭快捷酒店配电系统设计工程实例,分析现代酒店配电系统的设计思路与方法。1.2 工程概述本课题中的佟楼汉庭快捷酒店,该酒店建筑高四层,占地面积约5000平方米,共有132套客房,内设两部电梯,地下部分设有消防水池、设备用房及库房;一层设有餐厅、消防通道以及消防控制室;二层设有消毒布草间、无障碍客房;三至四层设有消毒布草间、无障碍客房等,楼顶设有排水装置。本次设计的主要任务是有关酒店的供配电系统、电气照明系统、消防系统及防雷接地系统的设计。2 供配电系统设计2.1 供配电系统的相关内容及基本要求 2.1.1 变配电所作为供电中枢,其设计的主要内容包括(1)根据变配电所供电的负荷性质以及其对供电可靠性的要求,进行负荷分级,从而确定所需的独立供电电源个数与供电电压等级。(2)为了确定无功补偿容量,将进行变配电所负荷计算与无功功率补偿计算。(3)简介变压器型号、容量、台数及开关设备选择。(4)变配电所所址选择:为了最大限度的节约电能与减少有色金属消耗量,通常应尽可能使高压深入负荷中心。但在建筑高度甚高或者是大容量负荷相当分散的情况下,也可分散布置多处变配电所,其布置方案应经过技术经济比较确定。在本设计中根据实际情况,将变配电所安排在地下室内。(5) 防雷保护以及接地装置设计。(6) 相关变配电所电气照明设计。(7)关于变电所的选址应严格符合10kV及以下变电所设计规范。 2.1.2 低压供配电系统的设计内容输电线路设计也就是电气外线设计。它包括供电电源线路设计和建筑物之间的配电线路设计。其设计内容应包括:线路路径及线路结构型式(架空线路还是电缆线路)的确定,导线截面的选择,架空线路杆位确定及标准电杆与绝缘子、金具的选择,弧垂的确定与荷载的效验,电缆敷设方式的确定,线路的导线或电缆及配电设备和保护设备选择,架空线路的防雷保护及接地装置的设计等。高压配电系统设计:多采用放射式系统,以增强其供电可靠性与控制的灵活性。对于有多处变压器分散设置的高层建筑,高压配电网络也可以采用环网结构。主要设计任务是:确定配电电压与配电网络结构;进行配电干线负荷计算;选择开关设备并进行短路效验;拟定二次回路方案并进行继电保护整定计算;选择高压电缆截面、型式、确定配电干线路径与敷设方式。低压配电系统设计:低压配电系统是民用建筑供配电系统的基本组成部分,无论就其重要性或工程量而言,都有举足轻重的地位。主要任务是:确定低压配电方式与配电网络的结构,其主要内容是竖直配电干线与水平配电干线的个数,位置与走向。进行分干线与干线的负荷计算,选择开关设备及导线、电缆、封闭式母线的截面与形式。选择保护装置,进行保护整定计算并保证其级间的选择性配合,以防止穿越性跳闸。确定线路敷设方式,进行电气竖井与配电小间的设计14-21。低压无功补偿容量计算,补偿方式与调节方式的选择。按需配置电气测量与电能计量装置。保护接地、重复接地系统的设计。电力设计通常指动力负荷的供电设计。在大型民用建筑中,特别是高层建筑中,动力负荷种类复杂,台数甚多,其容量自数千瓦至数百千瓦以上,此外,在民用建筑中的放火卷帘门、自动门、空调器以及各种生活服务机械的负荷也各不相同,必须通过合理的设计满足其供电要求。主要设计内容:确定负荷的位置、容量;按各动力负荷的性质及其对供电可靠性的要求,进行负荷分级,并采取相应的供电保证措施(如双电源互投的供电方式);确定动力负荷的配电网络型式,通常多采用放射式供电。确定配电装置的位置、选择开关设备与保护方式。按设备容量及其分组情况进行配电干线的负荷计算并选择干线保护的开关设备、导线截面与形式;确定线路敷设方式;进行接地系统与防电击技术措施的设计。本论文主要涉及低压配电系统。 2.1.3 设计基本要求供配电工作要很好的为用电部门及整个国民经济服务,必须达到以下的基本要求: (1) 安全在电力的供应、分配及使用中,不发生人身事故和设备事故。 (2) 可靠应满足电力用户对供电可靠性和连续性的要求。 (3) 优质应满足电力用户对电压质量和频率质量的要求。 (4) 经济应使供配电系统投资少,运行费用低,并尽可能的节约电能和减少有色金属消耗量。 另外,在供配电工作中,还应合理的处理局部和全局,当前与长远的关系,即要照顾局部和当前利益,又要有全局观点,能照顾大局,适应发展。2.2 负荷计算分类计算负荷又称需要负荷或最大负荷。计算负荷是一个假想的持续性负荷,其热效应与同一时间内实际变动负荷所产生的最大热效应相等。2.2.1 负荷的等级电力负荷应根据对供电可靠性的要求及中断供电在政治、经济上所造成损失或影响的程度进行分级,共分为一级、二级、三级负荷。并应符合以下所述的相关规定: (1) 一级负荷为中断供电将造成人身伤亡者;或将在政治上,经济上造成重大损失者;或中断将影响有重大政治经济意义的用电单位的正常工作者。(2) 二级负荷为中断供电将造成设备损坏,影响公共秩序,或在政治上,经济上造成较大损失。(3) 不属于一级及二级负荷的负荷是三级负荷本次设计的对象佟楼汉庭快捷酒店属于一般负荷,消防与通道照明属于一级负荷,房间照明属于三级。市电由区域变电站引来两路电源,供电变压器有两台。正常工作时,两路电源同时供电,互为备用,各负担一半左右负荷,一路电源故障时,另一路电源提供全部负荷。为了减少动力设备用电对照明线路电压波动的影响,照明用电与动力用电线路尽量分开供给。2.2.2 负荷计算的方法(1) 需要系数法:用设备功率乘以需要系数和同时系数,直接求出计算负荷。这种方法比较简单,应用广泛,尤其配电所的负荷计算。(2) 利用系数法:采用利用系数法求出平均负荷,再考虑设备台数和功率差异的影响,乘以与有效台数有关的最大系数得出计算负荷。这种方法的理论依据是概率论和数理统计,因而计算结果比较接近实际,但因利用系数实测与统计较难,在民用建筑电气中一般不用。(3) 二项式法:在设备组容量之和的基础上,考虑若干容量最大设备的影响,采用经验系数进行加权求和法计算负荷。(4) 单位面积功率法:单位指标法。 2.2.3负荷计算方法选取原则 (1) 在方案设计阶段可采用单位指标法;在初步设计及施工图设计阶段,宜采用需要系数法;对于住宅,在设计的各个阶段均可采用单位指标法;(2) 用电设备台数较多,各台设备容量相差不悬殊时,宜采用需用系数法,一般用于干线、配变电所的负荷计算;(3) 用电设备台数少,各台设备容量相差悬殊时,宜采用二项式法,一般用于之干线和配电(屏)箱的负荷计算。 2.2.4有关负荷计算的几点说明(1)用电设备进行分组计算时,按下列条件考虑:组成用电设备的设备功率,指不包括备用设备在内的所有单个用电设备的设备功率之和;三台及以下,计算负荷等于其设备功率的总和;三台以上时,其计算负荷通过计算确定;类型相同的用电设备,其总容量可以用算术加法求得。(2)当消防用电的计算有功功率大于火灾时可能同时切除的一般电力、照明负荷的计算有功功率时,应按未切除的一般电力,照明负荷,加上消防负荷计算低压总的设备功率,计算负荷。否则计算低压总负荷时,不应考虑消防负荷。(3)当采用需要系数法计算负荷时,应将配电干线范围内的用电设备按类型统一划组。配电干线的计算负荷为各用电设备组的计算负荷之和在乘以同时系数。2.2.5本论文负荷计算及负荷表(1)具体负荷计算过程中所需公式设:Pe为设备功率,为需要系数,为功率因数,有功计算负荷,无功计算负荷,视在计算负荷,计算电流。以下是本次计算中常用到的相关公式(需要系数法): (2-1) (2-2) (2-3) (2-4) (2-5) (2-6)其中:和是有功功率、无功功率同时系数,分别取0.75和0.8。整个酒店总的计算负荷时:=592.8KW,=380.88Kvar,=704.61KVA。在上述公式中前四个主要是用来计算用电设备组,后两个主要是用来计算配电干线和变电所。另外:对于任意标准客房按下列方法(单位指标法)计算:对于本课题而言,房间内单位面积功率取50W/m2,单个房间面积取30m2,则可得房间容量1.5KW。相关负荷计算如下:照明负荷表的计算(需要系数取0.7,功率因数取0.85):地下室照明:设备功率为10KW,将数据代入公式2-1得有功负荷=10*0.7=7KW;根据公式2-2得无功负荷=4.34kvar;根据公式2-3得视在负荷=8.24kvA;根据公式2-4得计算电流=12.52A。一楼餐厅照明:设备功率为100KW,将数据代入公式2-1得有功负荷=70KW;根据公式2-2得无功负荷=43.4kvar;根据公式2-3得视在负荷=82.35kvA;根据公式2-4得计算电流=125.12A。二、三、四楼房间照明:房间的功率为66KW,将数据代入公式2-1得有功负荷=46.2KW;根据公式2-2得无功负荷=28.64kvar;根据公式2-3得视在负荷=54.35kvA;根据公式2-4得计算电流=82.58A。一至四层通道照明:设备功率为12KW,数据代入公式2-1得有功负荷=8.4KW;根据公式2-2得无功负荷=5.21kvar;根据公式2-3得视在负荷=9.88kvA;根据公式2-4得计算电流=15.01A。电力及消防负荷表的计算:酒店空调机组(需要系数取0.7,功率因数取0.85):其设备功率为352KW,将数据代入公式2-1得有功负荷=246.4KW;根据公式2-2得无功负荷=152.77kvar;根据公式2-3可以得到视在负荷=308kvA;根据公式2-4得计算电流=467.97A。酒店乘客电梯(需要系数取0.7,功率因数取0.85):其设备功率为12KW,将数据代入公式2-1得有功负荷=8.4KW;根据公式2-2得无功负荷=5.21kvar;根据公式2-3得到视在负荷=10.5kvA;根据公式2-4得计算电流=15.96A。生活泵(需要系数取1,功率因数取0.85):其设备功率为33KW,将数据代入公式2-1得有功负荷=1.5KW;根据公式2-2得无功负荷=0.93kvar;根据公式2-3得到视在负荷=1.88kvA;根据公式2-4得计算电流=2.86A。地下应急照明(需要系数取1,功率因数取0.9):其设备功率为2KW,将数据代入公式2-1得有功负荷=1.8KW;根据公式2-2得无功负荷=0.86kvar;根据公式2-3得到视在负荷=2kvA;根据公式2-4得计算电流=3.34A。一至四层应急照明(需要系数取1,功率因数取0.9):其设备功率为6KW,将数据代入公式2-1得有功负荷=6KW;根据公式2-2得无功负荷=2.88kvar;根据公式2-3得到视在负荷=6.67kvA;根据公式2-4得计算电流=10.13A。消火栓泵(需要系数取1,功率因数取0.9):其设备功率为40KW,将数据代入公式2-1得有功负荷=40KW;根据公式2-2得无功负荷=19.2kvar;根据公式2-3得到视在负荷=44.44kvA;根据公式2-4得计算电流=67.52A。(2)照明负荷0.38KV配电干线及支干线负荷计算:计算如表2-1所示,主要针对酒店房间、餐厅、通道、地下室等部分进行相关负荷计算,具体计算参照附录。表2-1照明负荷0.38KV配电干线负荷表用电设备名称计算回路编号负荷等级设备功率/kw需要系数功率因数有功负荷/kw无功负荷/kvar视在负荷/kvA计算电流/A配电干线支干线夹层及24层照明WL1WL1-2-2三级10.70.850.70.430.821.25WL1-2-1三级660.70.8546.228.6454.3582.58WL1-r三级100.70.8574.348.2312.05WL1-3-2三级10.70.850.70.430.821.25WL1-3-1三级660.70.8546.228.6454.3582.58WL1-4-2三级10.70.850.70.430.821.25WL1-4-1三级660.70.8546.228.6454.3582.58三级2110.70.85147.791.55173.74263.541-4层通道照明WL2M一级4*30.70.858.45.219.8815.01一层餐厅照明WL3M一级1000.70.857043.482.35125.12地下室照明WL4M二级2*50.70.8574.348.2412.52合计3330.70.85380.8144.5274.21416.19其中一级负荷1120.70.8578.448.6192.24140.15其中二级负荷100.70.8574.348.2412.52照明负荷0.38KV配电干线负荷计算(3)电力负荷和消防负荷0.38KV配电干线及支干线负荷计算:计算如表2-2所示,主要针对酒店动力及消防部分进行负荷计算,包括各类水泵、空调、电梯、应急照明等相关部分,具体计算参照附录。表2-2电力(动力)及消防负荷0.38KV配电干线负荷表用电设备名称计算回路编号负荷等级设备功率需要系数功率因数有功负荷/kw无功负荷/kvar视在负荷/KVA计算电流/A配电干线支干线宾馆空调机组WP1三级3520.70.85246.4152.77308467.97宾馆空调水泵WP2三级300.70.852113.0226.2539.88宾馆乘客电梯WP3M一级120.70.858.45.2110.515.96地下排污泵WP4M一级2*0.7510.851.50.931.882.86生活泵WP5M一级3*1110.853320.4641.2562.67夹层及1-4层应急照明WLE1MWLE1M-1一级610.962.886.6710.13WLE1M-R一级310.931.443.335.06一级910.994.321015.2地下室应急照明WLE2M一级2*110.91.80.8623.34变电所用电WLE3M一级510.952.45.568.45消防控制室WPE1M一级1010.9104.811.1116.88消防电梯WPE2M一级1210.9125.7613.3320.25夹层排烟风机WPE3M一级7.510.97.53.68.3312.66地下室排烟风机WPE4M一级510.952.45.568.45消火栓泵WPE5M一级4010.94019.244.4467.52合计491.50.830.82409.6240.05498.21757.27电力负荷及消防负荷0.38KV配电干线负荷计算(4)变电所负荷计算:计算如表2-2所示,在照明、电力及消防负荷计算的基础上得出总负荷,从而确定变压器台数及容量。本工程使用两台500Kvar的变压器。表2-3变电所负荷表负荷名称设备功率/kw需要系数功率因数有功负荷/kw无功计算负荷/K var视在负荷/KVA计算电流/A无功补偿前低压母线的计算负荷合计照明、电力及消防负荷合计1013.50.780.86790.4476.1922.71401.9其中一级负荷2580.860.87220.8122.87252.68383.92其中二级负荷100.70.8574.348.2412.52一、二级负荷合计2680.830.87221.5127.21255.43388.1计入同时系数总负荷=0.75、=0.81013.50.580.84592.8380.88704.611070.6一、二级负荷=0.8、=0.852680.660.85177.2108.83207.95315.96无功补偿装置容量(并联电容器)容量Q=592.8kw*tan(arccos0.84)-tan(arccos0.92)=161.3kvar(取200kvar)-200无功补偿后低压母线的计算负荷总负荷1013.50.580.92592.8180.88619.78941.69其中一、二级负荷2680.660.9277.246.0989.91136.6变压器功率损耗Pt0.01Sc;Qt0.05Sc6.230.99变压器高压侧计算负荷1013.50.580.9599211.87873.21326.73变电所负荷计算2.2.6 无功功率补偿供电部门一般要求新建企业的月平均功率因数达到0.9以上。当达不到这个指标的时候就需要依靠无功功率设备进行补偿,从而提高企业的功率因数8-11。无功功率在系统的传输中所造成的影响如下: (1)无功功率在通过电网时,会引起线路及设备的有功损耗。(2)电网的电压损失将会随着无功功率的增加而增加。(3)在电网输送有功不变下,无功增加而使总电流增加,会使供电系统中的如变压器、断路器、导线以及测量仪器、仪器等等的一次、二次设备的容量、规格尺寸增大,从而使投资费用增加。基本要求如下:(1)设计中应正确选择电动机、变压器的容量,减少线路感抗。(2)当采用提高自然功率因数措施后,仍打不到下列要求时,应采用并联电力电容器作为无功补偿装置。其中,高压供电的用电单位功率因数基本要求为0.95;低压供电的用电单位功率因数基本要求为0.9。(3)高压供电的用电单位采用低压补偿时,高压侧的功率因数应满足供电部门的要求。(4)采用电力电容器作为无功补偿装置时,宜采用就地平衡原则。低压部分的无功负荷由低压电容器补偿,高压部分的无功负荷由高压电容器补偿。容量较大、负荷平稳且经常使用的用电设备的无功负荷宜单独就地补偿。补偿基本无功负荷的电容器组,宜在配变电所内集中补偿。居住区的无功负荷宜在小区变电所低压侧集中补偿。补偿装置的开关及导线的长期允许电流,高压不应小于电容器额定电流的1.35倍,低压不应小于电容器额定电流的1.5倍。在一、二类建筑中的电容器应采用干式电容器。电容器组应设有放电装置。在本次设计中,功率因数补偿到0.9,计算无功补偿装置容量所用公式如下: (2-7)其中:Pc=592.8KW,前后功率因数分别为0.84、0.92。经计算得无功补偿装置容量为161.3Kvar,本次设计取200Kvar。并联电容器补偿方式:本次设计中电容补偿的接线方式采用下图(图2-1)的接线方式:特点是初投资较少,运行和维护方便。图2-1 电容补偿的接线方式 2.3 低压配电系统接线方式低压配电系统有多种接线方式,其中包括放射式、树干式、链式、环式及其组合形式。应满足用电设备对供电可靠性及电能质量的要求,同时应注意接线简单、操作方便安全,具有一定灵活性。以下着重将对放射式以及树干式进行介绍。(1) 放射式:如图2-2所示,此种接线方式特点是配电线路相互独立,因而可靠性很高,某一线路出现故障时不会影响到其他线路。但放射式配电接线中,从低压配电柜引出的干线较多,使用的开关等材料较多,因此常用于可靠性较高的场所,如空调机组,消防水泵等。(2) 树干式:如图2-3所示,此种接线方式与放射式刚好相反,其从低压配电柜引出线路少,发生故障时波及范围广,因此可靠性较低。(3) 混合式:既有放射式,又有树干式。这种接线方式集合了以上两种方式的优点,如高层建筑中,当每层照明负荷都较小时,可以从低压配电柜放射式引出多条干线,将楼层照明配电箱分组接入干线,局部为树干式。 图2-2 放射式 图2-3 树干式2.4 配电设备的布置2.4.1 低压配电室的配电设备布置要求(1) 配电室的位置应靠近用电负荷中心,设置在尘埃少、腐蚀介质少、干燥和震动轻微的地方,并宜适当留有发展余地。(2) 配电设备的布置必须遵循安全、可靠、适用和经济等原则,并应便于安装、操作、搬运、检修、试验和监测。(3) 配电室内除本室需用的管道外,不应有其它的管道通过。室内管道上不应设置阀门和中间接头;水汽管道与散热器的连接应采用焊接。另外,配电屏的上方不应敷设管道。(4) 落地式配电箱的底部宜抬高,室内宜高出地面50mm以上,室外应高出地面200mm以上。底座周围应采取封闭措施,并应能防止鼠、蛇类等小动物进入箱内。(5) 同一配电室内并列的两段母线,当任一段母线有一级负荷时,母线分段处应设防火隔断措施。(6) 当高压及低压配电设备设在同一室内时,且二者有一侧柜顶有裸露的母线,二者之间的净距不应小于2m。2.4.2 对建筑的要求(1)配电室屋顶承重构件的耐火等级不应低于二级,其它部分不应低于三级。 配电室长度超过7m时,应设两个出口,并宜布置在配电室的两端。当配电室为楼上楼下两部分布置时,楼上部分的出口应至少有一个通向该层走廊或室外的安全出口。配电室的门均应向外开启,但通向高压配电室的门应为双向开启门。(2) 配电室的顶棚、墙面及地面的建筑装修应少积灰和不起灰;顶棚不应抹灰。(3) 配电室内的电缆沟应采取防水和排水措施。(4) 当严寒地区冬季室温影响设备的正常工作时,配电室应采暖。炎热地区的配电室应采取隔热、通风或空调等措施。(5) 有人值班的配电室,宜采用自然采光。在值班人休息间内宜设给水、排水设施。附近无厕所时宜设厕所。(6) 位于地下室和楼层内的配电室,应设设备运输的通道,并应设良好的通风和可靠的照明系统。2.4.3设备选择现代建筑开始要求电气设备防火、防潮、防爆、防污染、节能以及小型化。电气设备的选择是涉及多种因素,首先要考虑并坚持的是产品性能质量。电气产品的选用必须符合国家有关规范。其次才是经济性,要根据业主功能要求、经济情况做出选择。随着人们环境保护意识的日益增加,选择环保产品、节能产品也是新的时尚,这就不仅仅是钱的问题了。所要选择的产品包含在每个设计子项之中,主要有电源设备、高低压开关柜、电力变压器、电缆电线、母线槽、开关电器、照明灯具、电讯产品、消防安防产品、楼宇自控产品等等。 导线和电缆的选择方法:(1) 是按允许载流量选择导线和电缆的截面选取;(2) 是按机械强度选择导线的最小允许截面选取;(3) 是按电压损失校验导线和电缆的截面选取;(4) 是按经济电流密度选择导线截面选取。在本次设计中选择导线截面的方法采用的是:经济电流密度法。按经济电流密度选择导线截面计算公式(2-8): (2-8) 式中:S表示经济截面,单位:mm2; 表示导线负荷计算电流,单位:A; 表示经济电流密度,单位:A/mm2对于导线和电缆类型的选择:导体材料导在下列场合中宜采用铜芯导线和电缆:(1) 重要的操作回路及二次回路;(2) 移动设备的配电线路及剧烈震动场合的线路;(3) 爆炸危险场所有特殊要求者;(4) 重要的高级酒店、饭店;对于绝缘及护套选择:(1) 塑料绝缘线:其绝缘性能良好,价格较低,无设或穿管敷设均可替代橡皮绝缘线。缺点是对气候适应性较差,由于不能耐高温,绝缘容易老化,所以塑料绝缘线不宜在室外敷设。(2) 氯丁橡皮绝缘线:其特点是耐油性能好,不宜霉,不延燃,光老化过程缓慢,因此可以在室外敷设。35平方毫米及以下的普通橡皮绝缘线有被氯丁橡皮绝缘取代趋势。(3) 油浸纸绝缘电力电缆:其耐热能力强,允许运行温度较高寿命长。由于绝缘层内油的淌流,电缆两端水平高差不宜过大。(4) 聚氯丁乙烯绝缘及护套电力电缆:其主要优点是重量轻,弯曲性能好,接头制作简便,没有敷设高差的限制。适宜于高层建筑使用。(5) 橡皮绝缘电力电缆:其弯曲性能好,能够在严寒气候敷设,特别适用于水平高差大和垂直敷设的场合。不仅适用于固定敷设的线路,也可用于定期移动的线路。因此应用较为广泛22-25。(6) 射交联电线电缆:其材料具有特殊的耐热性、耐化学性、高阻燃性以及高强度性。(7) 联聚乙烯绝缘聚氯乙烯护套电力电缆:其性能优良,结构简单,制造方便,外径小,重量轻,载流量大敷设方便。2.5 变电所低压侧电气主接线图变电所低压侧电气接线图如附录中的图表所示3 照明系统设计 3.1 酒店照明设计的特点(1)色温与照度的相关注意事项首先,要普遍采用暖白色的光源,色温为3000K左右无论什么类型的酒店,营造亲切、温馨和友好的氛围,应该是它们共同的目标。而色温3000K的光源所提供的照明环境,能够强化酒店的这一特点。这种特点,在心理层次的深度唤起上,它是同亲切、温馨、友好这样一些心理评价和情感活动紧密联系在一起的。对于人的视觉对色彩的温度知觉和空间知觉的研究,色相偏于橙黄的色彩同色相偏于蓝紫色的色彩,在同时对比时,橙黄让人感觉温暖。基于工程实践,每当一个酒店照明工程,能够在没有各方面干扰的情况下,彻底落实这一原则,其效果就非常好,所以这一原则比较重要。其次,照明设计要有针对性地选择光源类别,在色温相同的条件下,要综合权衡它们在光通量、平均寿命上的是否节能等是否便于维护与光色之间的取舍,不要因为“绿色照明”而不采用白炽灯。对酒店而言,节能和便于维护固然重要,比如,目前一支好的紧凑型荧光灯的平均寿命能达10000小时(而白炽灯只有它的十分之一),虽然酒店免去了更换灯泡的成本,但牺牲了“纯净的光色”。至于节能和延长灯泡寿命的问题,可以结合天然采光和客人活动对亮度的要求,通过智能控制系统适时地进行调光,来加以解决。例如:由美国路创提供的智能照明控制系统进行自动化控制,对中庭照明,系统软件利用时钟触发的开关,按照一天不同时段的天然采光进行调光,不仅节省能源,而且延长了光源寿命利用照度和色温的匹配关系,细致的营造适宜的空间气氛。一般地讲,色温和照度应成正比例的搭配,即高色温、高照度,反之亦然。国内酒店照明设计的习惯经常是,色温很高,但照度又普遍偏低,经常是陷入下图所表示的“阴沉”的气氛中去。这在今后的设计实践中,要给予足够的重视。(2)能用直接照明的,就不采用间接照明方式光槽目前已经在各类商业空间照明中被广泛的使用,甚至有些泛滥。随着电光源、照明灯具制造技术的发展,用直接照明的方式已经能够避免不舒适眩光对视觉的危害,所以,除非装饰性的要求,否则,就不要采用光通浪费严重并且不方便维护的各种类型的发光槽。使用同样色温的光源,避免光色的杂乱无章同一个功能区域、表面和物体,采用色温一致的光源,令光环境的色调统一。就酒店的照明设计而言,由于强调的不是冲突和戏剧性,所以,统一的色调才符合酒店的特点。选择合适的配光针对酒店不同功能区域的室空比,对配光曲线的光强分布、中心光强和半光强等配光参数加以甄别,以避免两个方面的光通损失。店前厅通常位于建筑的裙楼,天花板通常都很高,挑高6m以上是很常见的,选用光束角窄、投光距离长的照明器,才不致于上部很亮,而地面及离地面1m处人的活动区域却亮度不足。 反之,若在客房等天花板较矮的区域使用这样的配光,则会出现地面很亮,而垂直面照度不足等问题。(3)光源的显色指数就要高光源的显色性一般用CIE的显色指数来评价,它是对包括人的肤色在内的10几个色样,用待评价的光源和标准光源(全阴天空光)进行色彩显示的差异性评价。笼统地讲,一个光源的Ra越高,表明它显色性就越好。但需要指出的是,因为Ra取的是色样的平均值,所以,虽然有的光源的显色指数很高,但对某一特定颜色的显现可能会不好。这一点要引起酒店照明设计的重视。在国内的照明标准和设计实践中,一直对照明的显色性不太重视,通常强调在有辨色要求的场所才需要高显色指数的光源。实则不然,一般人与人有较多接触的场所,尤其是酒店,客人能够显现出健康的肤色是非常重要的。另外,显色性好的光源给人的感觉要清晰一些。3.2照明配电系统设计应遵循的基本原则(1) 正常照明电源宜与电力负荷合用变压器,但不宜与较大冲击性电力负荷合用。对于照明容量较大而又集中的场所,如果电压波动或偏差过大,严重影响照明质量或灯泡寿命,可装设照明专用变压器或调压装置。 (2)民用建筑照明负荷计算宜采用需用系数法。需要系数值可参考下表,在计算照明分支回路和应急照明的所有回路时需要系数均应取1。三相照明线路各相负荷分配,宜保持平衡,在每个分配电盘中的最大与最小相的负荷电流差不宜超过30%。 特别重要的照明负荷,宜在负荷末级配电盘采用自动切换电源的方式,也可采用由两个专用回路各带约50%的照明灯具的配电方式。 备用照明(供继续和暂时继续工作的照明)应由两路电源或两回路供电,其具体方案如下:当有两路高压电源供电时,备用照明的供电干线接自两段高压母线上的不同变压器;当采用两路低压电源供电时,备用照明的供电应从两段低压配电干线分别接引;当供电条件不具备两路电源或两回路时,备用电源宜采用蓄电池组,或设置带有蓄电池的应急照明等。(3) 疏散照明最好由另一台变压器供电。当只有一台变压器时,可在母线处或建筑物进线处与正常照明处分开,还可以采用镉镍电池(荧光灯还需要带有直流逆变器)的应急照明灯。(4) 当备用照明作为正常照明的一部分并经常使用时,其配电线路及控制开关应分开装设。当备用照明仅在事故情况下使用时,则当正常照明因故停电时,备用照明应自动投入工作。在有专人值班时,可采用手动投入。(5) 在照明分支回路中,避免采用三相低压断路器对三个单相分支回路进行控制和保护。(6) 照明系统中的每一单相回路的电流不宜超过16A,灯具数量不宜超过25个。大型建筑组合灯具每一单相回路电流不宜超过25A,光源数量不宜超过60个。建筑物轮廓灯每一单相回路不宜超过100个。当灯具和插座混用同一回路时,总数不宜超过25个,其中插座数量不宜超过5个(组)。当插座为单独回路时,数量不宜超过10个(组)。插座宜由单独的回路配电,并且一个房间内的插座宜由同一回路配电。备用照明、疏散照明的回路上不应设置插座。(7) 一般情况下,可将其同一或不同灯具的相邻等管分接在不同相序的线路上,这是为了减轻气体放电光源的频闪效应,。(8) 注意不应将线路敷设在高温灯具的上部,接入高温灯具的线路应采用耐热导线配线或采取其他隔热措施。(9) 在潮湿的房间(洗手间、厨房等)内,不允许装设一般插座,必须装防水防潮型插座,或者设置有安全隔离变压器的插座。(10) 另外,当需要采用直流应急照明电源时,其电压可根据容量大小,使用要求来确定,照明网络的电压选择一般采用220/380V三相四线制中性点直接接地系统,灯用电压一般为220V。(11) 在特别潮湿、高温、有导电灰尘或导电地面的场所,当灯具安装高度距地面为2.4m及以下时,容易触及的固定式或移动式照明器的电压可选用24V,或采取其它防电击措施。3.2.1 房间插座布置插座的用途不言而喻,它在酒店电气设计中也是关键的一环,我们通常布置插座是参照建筑专业提供的布置平面图,但是,将来的业主并不一定按照建筑师给他安排的方案来布置,因此,有些插座设计时是合理的,而使用时却很不方便。故此,我们不要单纯的以建筑专业提供的图纸来安排插座,而是尽量的多安排一些插座,由于现在插座的价格相对来说比较便宜,总的造价增加不了太多,却带来了很大的方
温馨提示
- 1. 本站所有资源如无特殊说明,都需要本地电脑安装OFFICE2007和PDF阅读器。图纸软件为CAD,CAXA,PROE,UG,SolidWorks等.压缩文件请下载最新的WinRAR软件解压。
- 2. 本站的文档不包含任何第三方提供的附件图纸等,如果需要附件,请联系上传者。文件的所有权益归上传用户所有。
- 3. 本站RAR压缩包中若带图纸,网页内容里面会有图纸预览,若没有图纸预览就没有图纸。
- 4. 未经权益所有人同意不得将文件中的内容挪作商业或盈利用途。
- 5. 人人文库网仅提供信息存储空间,仅对用户上传内容的表现方式做保护处理,对用户上传分享的文档内容本身不做任何修改或编辑,并不能对任何下载内容负责。
- 6. 下载文件中如有侵权或不适当内容,请与我们联系,我们立即纠正。
- 7. 本站不保证下载资源的准确性、安全性和完整性, 同时也不承担用户因使用这些下载资源对自己和他人造成任何形式的伤害或损失。
最新文档
- 2025年林业碳汇行业当前发展现状及增长策略研究报告
- 收纳与劳动课件
- 操作工安全知识培训课件
- 2025年药物临床试验GCP专项测试题附答案
- 2025年消防人员岗位职业救援安全基础知识考试题与答案
- 2025消防安全知识考试题附答案
- 2024年事业单位招聘考试公共基础知识试题及答案1
- 2024年二建《市政实务》考试真题及答案
- 2025年注册安全工程师法规、管理、技术、实务真题及答案
- 2025国家公务员考试行测题库(附答案)
- 2025年0-3岁儿童发展指南
- 个人与公司合作合同协议
- 2025数字量化混凝土配合比设计标准
- 中职校长外出培训汇报
- 软件系统运维操作手册
- 江苏省低空空域协同管理办法(试行)
- 三升四数学综合练习(60天)暑假每日一练
- 直肠癌个案护理
- 西门塔尔牛养殖技术课件
- 油库培训大纲及课件
- (正式版)JBT 3300-2024 平衡重式叉车 整机试验方法
评论
0/150
提交评论