Socomec电压电流表联PROFIBUS-DP网使用说明.pdf_第1页
Socomec电压电流表联PROFIBUS-DP网使用说明.pdf_第2页
Socomec电压电流表联PROFIBUS-DP网使用说明.pdf_第3页
Socomec电压电流表联PROFIBUS-DP网使用说明.pdf_第4页
Socomec电压电流表联PROFIBUS-DP网使用说明.pdf_第5页
已阅读5页,还剩37页未读 继续免费阅读

下载本文档

版权说明:本文档由用户提供并上传,收益归属内容提供方,若内容存在侵权,请进行举报或认领

文档简介

FDINLGBEP DIRIS A40 A41 RS485 PROFIBUS DP Operating instructions ON 1 COM PROFIBUS Certifi cation 2SOCOMEC R f 876 786 A GB 3SOCOMEC R f 876 786 A GB PRELIMINARY OPERATIONS 4 GENERAL INFORMATION 4 INSTALLATION 5 PROGRAMMING 6 CONFIGURATION 10 USE OF PROFIBUS DP MODULES 15 MODULE 1 MAIN MEASUREMENTS 15 MODULE 2 ADDITIONAL MEASUREMENTS 20 MODULE 3 TROUGH POWER CUT MEAN POWER 22 MODULE 4 OVERVOLTAGE MEAN VOLTAGE AND FREQUENCIES MAXIMUM AND MEAN In 23 MODULE 5 CURRENT HARMONICS 24 MODULE 6 PHASE TO PHASE VOLTAGE 25 MODULE 7 PHASE TO NEUTRAL VOLTAGE 26 MODULE 8 INSTANTANEOUS MIN MAX 27 MODULE 9 SPECIAL FRAME 28 MODULE 11 LIMITED SPECIAL FRAME 35 DIAGNOSTICS 37 TECHNICAL CHARACTERISTICS 39 PROFIBUS CERTIFICATION 40 Contents GB 4SOCOMEC R f 876 786 A GB DIRIS A40 A41 RS485 PROFIBUS DP PRELIMINARY OPERATIONS N 1N 2N n 1500 M Programmable controllers Other systems N 1 RS485 0 0 N n 1500 M 1500 M Programmable controllers Other systems repetor DIRIS 699 A GBDIRIS 700 A GB Recommendations You should use a garantieed cable PROFIBUS NB It is essential to attach an active termination to the 2 link up ends This termination can be found on the model RS 485 Remember to put the 2 switches to ON when attaching For personnel and product safety please read the contents of these operating instructions carefully before connecting Check the following points as soon as you receive the Diris A40 A41package the packing is in good condition the product has not been damaged during transit the product reference number conforms to your order the package contains 2 option modules the fi rst of which is equipped with a disconnectable terminal block a CD Rom GENERAL INFORMATION Functions This optional module must be connected to the DIRISA40 A41 ref 4825 0A40 4825 0A41 4825 1A40 4825 1A41 It provides an RS485 serial link 2 or 3 wires with PROFIBUS DP protocol for the use of DIRIS A40 A41from a PC or PLC General points In a standard confi guration an RS485 link allows 1 to 32 DIRIS A40 A41to be linked to 1 to 32 pieces of equip ment using the PROFIBUS DP protocol The maximum communication speed is 1 5 Mbauds over 200 m This distance can be increased if the speed is reduced Standards EN50170 5SOCOMEC R f 876 786 A GB GB CONNECTION The option modules are installed on the rear panel of the DIRIS A40 A41in one of the four positions provided DIRIS 342 A DIRIS 343 A ON1 ON 1 0V COM DIRIS 469 B Fix the option modules next to each other Follow indications when connecting the terminal Switch on voltage supply TheDIRIS A40 A41must be switched off DIRIS A40 A41 RS485 PROFIBUS DP INSTALLATION Note Correspondence with a HAN BRID connector B red A green 6SOCOMEC R f 876 786 A GB DIRIS A40 A41 RS485 PROFIBUS DP PROGRAMMATION Previous menu Following menu p 7 p 8 p 9 7SOCOMEC R f 876 786 A GB GB DIRIS A40 A41 RS485 PROFIBUS DP PROGRAMMATION COMMUNICATION ADDRESS Example COM ADR 7 x 3 x 2 x 1 confi rm 8SOCOMEC R f 876 786 A GB DIRIS A40 A41 RS485 PROFIBUS DP PROGRAMMATION DIAGNOSTIQUE Example COM DIAG NO x 1 x 1 NO x 2 YES x 1 confi rm NB This function allows switching the diagnosis function or off see p 37 9SOCOMEC R f 876 786 A GB GB DIRIS A40 A41 RS485 PROFIBUS DP PROGRAMMATION ACTIVATION OF THE PROGRAMME VIA THE PROFIBUS MASTER Example COM PARA YES x 1 x 1 YES x 2 NO x 1 confi rm Nb This function allows activating or deactivation of the DIRIS programming by the PROFIBUS DP master If this function is deactivated please note that in case of loss of the slave DIRIS the master will not send the GSD file parameters and thus won t re programme the DIRIS Awith the factory parameters 10SOCOMEC R f 876 786 A GB DIRIS A40 A41 RS485 PROFIBUS DP CONFIGURATION The table below gives the confi guration of the DIRIS A40 A41used when starting a PROFIBUS DP cycle NameSize bytes Manufacturer parameter1 Always equal to zero Network type1 0 1 BL 1 2 BL 2 3 BL 3 3 NBL 4 4 BL 5 4 NBL CT secondary A 1 1 1 A 5 5 A CT primary A 2 Voltage input on PT1 0 No 1 Yes PT primary V 4 PT secondary V 1 60 60 V 100 100 V 110 110 V 115 115 V 120 120 V 173 173 V 190 190 V Synchronisation of I AVG MAX1 5 5 mn 8 8 mn 10 10 mn 15 15 mn 20 20 mn 30 30 mn 60 60 mn Synchronisation of P Q S AVG MAX1 5 5 mn 8 8 mn 10 10 mn 15 15 mn 20 20 mn 30 30 mn 60 60 mn OUT 1 allocation1 0 kWh 1 kvarh 2 kVAh 3 kWh 4 kvarh OUT 1 impulse value kWh kvarh kVAh 1 0 0 1 1 1 2 10 11SOCOMEC R f 876 786 A GB GB DIRIS A40 A41 RS485 PROFIBUS DP CONFIGURATION 3 100 4 1000 5 10000 OUT 1 impulse duration ms 1 1 100 2 200 3 300 4 400 5 500 6 600 7 700 8 800 9 900 OUT 2 allocation1 0 kWh 1 kvarh 2 kVAh 3 kWh 4 kvarh OUT 2 impulse value kWh kvarh kVAh 1 0 0 1 1 1 2 10 3 100 4 1000 5 10000 OUT 2 impulse duration ms 1 1 100 2 200 3 300 4 400 5 500 6 600 7 700 8 800 9 900 Analog output type OUT 11 0 0 20 mA 1 4 20 mA 2 Alim Allocation of analog output OUT 11 0 I1 1 I2 2 I3 3 In 4 U12 5 U23 6 U31 7 P 8 Q 9 S NameSize bytes 12SOCOMEC R f 876 786 A GB DIRIS A40 A41 RS485 PROFIBUS DP CONFIGURATION NameSize bytes 10 PF 11 V1 12 V2 13 V3 14 F Value at 0 or 4 mA from analog output OUT 12 Unit at 0 or 4 mA from analog output OUT 11 0 1 k 2 M Value at 20 mA from analog output OUT 12 Unit at 20 mA from analog output OUT 11 0 1 k 2 M Analog output type OUT 21 0 0 20 mA 1 4 20 mA 2 Alim Allocation of analog output OUT 21 0 I1 1 I2 2 I3 3 In 4 U12 5 U23 6 U31 7 P 8 Q 9 S 10 PF 11 V1 12 V2 13 V3 14 F Value at 0 or 4 mA from analog output OUT 22 Unit at 0 or 4 mA from analog output OUT 21 0 1 k 2 M Value at 20 mA from analog output OUT 22 Unit at 20 mA from analog output OUT 21 0 1 k 2 M Analog output type OUT 31 0 0 20 mA 1 4 20 mA 2 Supply 13SOCOMEC R f 876 786 A GB GB DIRIS A40 A41 RS485 PROFIBUS DP CONFIGURATION NameSize bytes Allocation of analog output OUT 31 0 I1 1 I2 2 I3 3 In 4 U12 5 U23 6 U31 7 P 8 Q 9 S 10 PF 11 V1 12 V2 13 V3 14 F Value at 0 or 4 mA from analog output OUT 32 Unit at 0 or 4 mA from analog output OUT 31 0 1 k 2 M Value at 20 mA from analog output OUT 32 Unit at 20 mA from analog output OUT 31 0 1 k 2 M Analog output type OUT 41 0 0 20 mA 1 4 20 mA 2 Supply Allocation of analog output OUT 41 0 I1 1 I2 2 I3 3 In 4 U12 5 U23 6 U31 7 P 8 Q 9 S 10 PF 11 V1 12 V2 13 V3 14 F Value at 0 or 4 mA from analog output OUT 42 Unit at 0 or 4 mA from analog output OUT 41 0 1 k 2 M 14SOCOMEC R f 876 786 A GB DIRIS A40 A41 RS485 PROFIBUS DP CONFIGURATION NameSize bytes Value at 20 mA from analog output OUT 42 Unit at 20 mA from analog output OUT 41 0 1 k 2 M CT In secondary A 1 1 1 A 5 5 A CT In primary A 2 Length 54 bytes NB All this information is integrated in the GSD file User Prm Data Check that the parameterisation data are identical to the data programmed in the device When the PROFIBUS master loses a slave it re injects the parameters from the GSD fi le which will re set the factory confi guration There are two solutions to inhibit this function Deactivate the master s DIRIS A programming see also page 9 Confi gure the DIRIS Athrough the master then open and close the DIRIS A programming menu directly by the keypad code 100 15SOCOMEC R f 876 786 A GB GB DIRIS A40 A41 RS485 PROFIBUS DP USE OF THE PROFIBUS DP MODULES NameSize bytes Change of relay status if bit on 1 then taken into account otherwise bit on 01 bit 0 Relay 1 bit 1 Relay 2 bit 2 Relay 3 second option relay 1 bit 3 Relay 4 second option relay 2 bit 4 Change in relay confi guration bit 5 Resetting of one measurement bit 6 not used bit 7 not used Relay 1 on break1 0 open 1 closed Relay 2 on break1 0 open 1 closed Relay 3 on break1 0 open 1 closed Relay 4 on break1 0 open 1 closed Allocation OUT 11 0 Cde 1 I 2 U 3 P 4 Q 5 S 6 F 7 PFL 8 Thd 3I 9 Thd 3U 10 In 11 time 12 V 13 Thd In 14 Thd 3V 15 P 16 Q 17 PFC Lower threshold OUT 12 Lower threshold unit OUT 11 0 1 k 2 M Upper threshold OUT 12 MODULE 1 MAIN MEASUREMENTS This module contains the currents powers frequen cies power factor positive energies and hour meter Example Modifi cation of relay 1 set bit 4 relay confi guration change set bit 0 relay 1 to 1 modify the status byte on relay 1 break next byte The modules contain the inputs display and outputs confi guration Output frame 16SOCOMEC R f 876 786 A GB DIRIS A40 A41 RS485 PROFIBUS DP USE OF THE PROFIBUS DP MODULES NameSize bytes Upper threshold unit OUT 11 0 1 k 2 M Hysteresis 0 to 99 OUT 1 1 Time delay OUT 1 s 2 Allocation OUT 21 0 Cde 1 I 2 U 3 P 4 Q 5 S 6 F 7 PFL 8 Thd 3I 9 Thd 3U 10 In 11 time 12 V 13 Thd In 14 Thd 3V 15 P 16 Q 17 PFC Lower threshold OUT 22 Lower threshold unit OUT 21 0 1 k 2 M Upper threshold OUT 22 Upper threshold unit OUT 21 0 1 k 2 M Hysteresis 0 to 99 OUT 2 1 Time delay OUT 2 s 2 Zero reset2 bit 0 Max 3I bit 1 Max P bit 2 Max P bit 3 Max Q bit 4 Max Q bit 5 Max S bit 6 hour meter bit 7 kWh bit 8 kvarh bit 9 kVA bit 10 kWh bit 11 kvarh bit 12 all the parameters bit 13 Input 1 bit 14 Input2 bit 15 not used MODULE 1 MAIN MEASUREMENTS Output frame 17SOCOMEC R f 876 786 A GB GB DIRIS A40 A41 RS485 PROFIBUS DP USE OF THE PROFIBUS DP MODULES MODULE 1 MAIN MEASUREMENTS Output frame NameSize bytes Zero reset supplementary options2 bit 0 Input 1 bit 1 Input 2 bit 2 Input 3 bit 3 Input 4 bit 4 Not used bit 5 Not used bit 6 Min Max I bit 7 Min Max In bit 8 Min Max U bit 9 Min Max Frequency bit 10 Min Max PF bit 11 Min Max P bit 12 Min Max Q bit 13 Min Max Thd I bit 14 Min Max Thd In bit 15 Min Max Thd U Length 29 bytes 18SOCOMEC R f 876 786 A GB DIRIS A40 A41 RS485 PROFIBUS DP USE OF THE PROFIBUS DP MODULES MODULE 1 MAIN MEASUREMENTS Frame of inputs not allocated for current and voltage transformation ratios NameSize bytes Phase 1 current mA 2 Phase 2 current mA 2 Phase 3 current mA 2 Neutral current mA 2 Phase to phase voltage U12 V 10 2 Phase to phase voltage U23 V 10 2 Phase to phase voltage U31 V 10 2 Phase to neutral voltage phase 1 V 10 2 Phase to neutral voltage phase 2 V 10 2 Phase to neutral voltage phase 3 V 10 2 Frequency Hz 100 2 Active power kW 10 2 Reactive power kvar 10 2 Apparent power kVa 10 2 Power factor L C2 capacitive and inductive 0 001 I1 max mA 2 I2 max mA 2 I3 max mA 2 Maximum value active power W 2 Maximum value active power W 2 Maximum value reactive power var 2 Maximum value reactive power var 2 Maximum apparent power VA 2 Active energy 10000 kWh 2 Reactive energy 10000 kvarh 2 Apparent energy 10000 kVAh 2 System I mA 2 System U V 10 2 System V V 10 2 Hour meter 10000 H 100 2 Length 68 bytes 19SOCOMEC R f 876 786 A GB GB DIRIS A40 A41 RS485 PROFIBUS DP USE OF THE PROFIBUS DP MODULES Calculation of the values allocated The currents must be multiplied by the CT ratio the vol tages by the PT ratio in HV and the powers by the ratio CT x PT Example CT 100 20 VT 20000 200 5 100 CT x VT 20 x 200 4000 Powers will be multiplied by 4000 if there is no VT then VT 1 currents by 20 and voltages by 200 NB I system I1 I2 I3 3 U system U12 U21 U31 3 V system V1 V2 V3 3 Transformation of signed values into unsigned values If the currents voltages or energies are negative the following rule must be applied take the opposite bit by bit of the datum add 1 to this opposite Example negative datum 28864mv or in binary 0111 0000 1100 0000 opposite is equal to 1000 1111 0011 1111 opposite 1 is equal to 1000 1111 0100 0000 or in decimal 366 72 20SOCOMEC R f 876 786 A GB DIRIS A40 A41 RS485 PROFIBUS DP USE OF THE PROFIBUS DP MODULES MODULE 2 SUPPLEMENTARY MEASUREMENTS NameSize bytes Active power phase 1 kW 10 2 Active power phase 2 kW 10 2 Active power phase 3 kW 10 2 Reactive power phase 1 kvar 10 2 Reactive power phase 2 kvar 10 2 Reactive power phase 3 kvar 10 2 Apparent power phase 1 kVA 10 2 Apparent power phase 2 kVA 10 2 Apparent power phase 3 kVA 10 2 Power factor phase 1 0 001 2 capacitive and inductive Power factor phase 2 0 001 2 capacitive and inductive Power factor phase 3 0 001 2 capacitive and inductive Average value I1 mA 2 Average value I2 mA 2 Average value I3 mA 2 Average value active power W 2 Average value active power W 2 Average value reactive power var 2 Average value reactive power var 2 Average value apparent power VA 2 Active energy 10000 kWh 2 Reactive energy 10000 kvarh 2 Input pulse meter 1 100002 Input pulse meter 2 100002 Input pulse meter 3 100002 Input pulse meter 4 100002 Status inputs 1 2 3 4 2 This module contains the measurements by phase average values negative energies impulse meters on off inputs and statuses on off inputs The output frame is identical to module 1 Input frame Length 66 bytes 21SOCOMEC R f 876 786 A GB GB DIRIS A40 A41 RS485 PROFIBUS DP USE OF THE PROFIBUS DP MODULES Calculation of the values allocated The currents must be multiplied by the CT ratio the voltages by the PT ratio in HV and the powers by the CT x PT ratio Example CT 100 20 VT 20000 200 5100 CT x VT 20 x 200 4000 Powers will be multiplied by 4000 if there is no VT then VT 1 currents by 20 and voltages by 200 Status of the inputs input 1 bit 0 input 2 bit 1 input 3 bit 2 input 4 bit 4 If active the bit is on 1 If inactive the bit is on 0 Transformation of signed values into unsigned values If the currents voltages or energies are negative the following rule must be applied take the opposite bit by bit of the datum add 1 to this opposite Example negative datum 28864mv or in binary 0111 0000 1100 0000 opposite is equal to 1000 1111 0011 1111 opposite 1 is equal to 1000 1111 0100 0000 or in decimal 366 72 V 22SOCOMEC R f 876 786 A GB DIRIS A40 A41 RS485 PROFIBUS DP USE OF THE PROFIBUS DP MODULES MODULE 3 DIPS INTERRUPTION TREND POWERS AND FREQUENCY NameSize bytes Last voltage dips Residual phase to phase voltage involved 0 none 5 U12 6 U23 7 U311 Value V 100 4 Residual phase to neutral voltage involved 0 none 22 V1 23 V2 24 V31 Value V 100 4 Length ms 4 Month1 Day1 Year1 Hour1 Minute1 Second1 Last power interruption Month1 Day1 Year1 Hour1 Minute1 Second1 Last average power Last P value kW 10 2 Last P value kW 10 2 Last Q value kvar 10 2 Last Q value kvar 10 2 Last average frequency Last frequency value Hz 100 2 Length 36 bytes 23SOCOMEC R f 876 786 A GB GB DIRIS A40 A41 RS485 PROFIBUS DP USE OF THE PROFIBUS DP MODULES MODULE 4 SWELL TREND VOLTAGES IN MAXIMUM AND AVERAGE NameSize bytes Last swell Maximum phase to phase voltage involved 0 none 5 U12 6 U23 7 U311 Value V 100 4 Maximum phase to neutral voltage involved 0 none 22 V1 23 V2 24 V31 Value V 100 4 Length ms 4 Month1 Day1 Year1 Hour1 Minute1 Second1 Average voltage Last phase to phase voltage value U12 V 10 2 Last phase to phase voltage value U23 V 10 2 Last phase to phase voltage value U31 V 10 2 Last phase to neutral voltage value V1 V 10 2 Last phase to neutral voltage value V2 V 10 2 Last phase to neutral voltage value V3 V 10 2 Average and maximum neutral current Average In mA 2 Average maximum In mA 2 Length 36 bytes 24SOCOMEC R f 876 786 A GB DIRIS A40 A41 RS485 PROFIBUS DP USE OF THE PROFIBUS DP MODULES MODULE 5 CURRENT HARMONICS This module contains the thd Is the thd INs and the individual harmonics up to number 15 The output frame is identical to module 1 NameSize bytes Thd I1 0 1 2 Thd I2 0 1 2 Thd I3 0 1 2 Thd In 0 1 2 Harmonic I1 row 3 0 1 2 Harmonic I2 row 3 0 1 2 Harmonic I3 row 3 0 1 2 Harmonic In row 3 0 1 2 Harmonic I1 row 5 0 1 2 Harmonic I2 row 5 0 1 2 Harmonic I3 row 5 0 1 2 Harmonic In row 5 0 1 2 Harmonic I1 row 7 0 1 2 Harmonic I2 row 7 0 1 2 Harmonic I3 row 7 0 1 2 Harmonic In row 7 0 1 2 Harmonic I1 row 9 0 1 2 Harmonic I2 row 9 0 1 2 Harmonic I3 row 9 0 1 2 Harmonic In row 9 0 1 2 Harmonic I1 row 11 0 1 2 Harmonic I2 row 11 0 1 2 Harmonic I3 row 11 0 1 2 Harmonic In row 11 0 1 2 Harmonic I1 row 13 0 1 2 Harmonic I2 row 13 0 1 2 Harmonic I3 row 13 0 1 2 Harmonic In row 13 0 1 2 Harmonic I1 row 15 0 1 2 Harmonic I2 row 15 0 1 2 Harmonic I3 row 15 0 1 2 Harmonic In row 15 0 1 2 Input frame NB The individual harmonics are available if the harmonic module is connected Length 64 bytes 25SOCOMEC R f 876 786 A GB GB DIRIS A40 A41 RS485 PROFIBUS DP USE OF THE PROFIBUS DP MODULES MODULE 6 PHASE TO PHASE VOLTAGE HARMONICS This module contains the thd 3U and the individual har monics up to number 15 The output frame is identical to module 1 NameSize bytes Thd U12 0 1 2 Thd U23 0 1 2 Thd U31 0 1 2 Harmonic U12 row 3 0 1 2 Harmonic U23 row 3 0 1 2 Harmonic U31 row 3 0 1 2 Harmonic U12 row 5 0 1 2 Harmonic U23 row 5 0 1 2 Harmonic U31 row 5 0 1 2 Harmonic U12 row 7 0 1 2 Harmonic U23 row 7 0 1 2 Harmonic U31 row 7 0 1 2 Harmonic U12 row 9 0 1 2 Harmonic U23 row 9 0 1 2 Harmonic U31 row 9 0 1 2 Harmonic U12 row 11 0 1 2 Harmonic U23 row 11 0 1 2 Harmonic U31 row 11 0 1 2 Harmonic U12 row 13 0 1 2 Harmonic U23 row 13 0 1 2 Harmonic U31 row 13 0 1 2 Harmonic U12 row 15 0 1 2 Harmonic U23 row 15 0 1 2 Harmonic U31 row 15 0 1 2 Input frame NB The individual harmonics are available if the harmonic module is connected Length 48 bytes 26SOCOMEC R f 876 786 A GB DIRIS A40 A41 RS485 PROFIBUS DP USE OF THE PROFIBUS DP MODULES MODULE 7 PHASE TO NEUTRAL VOLTAGE HARMONICS This module contains the thd 3V and the individual har monics up to number 15 The output frame is identical to module 1 NameSize bytes Thd V1 0 1 2 Thd V2 0 1 2 Thd V3 0 1 2 Harmonic V1 row 3 0 1 2 Harmonic V2 row 3 0 1 2 Harmonic V3 row 3 0 1 2 Harmonic V1 row 5 0 1 2 Harmonic V2 row 5 0 1 2 Harmonic V3 row 5 0 1 2 Harmonic V1 row 7 0 1 2 Harmonic V2 row 7 0 1 2 Harmonic V3 row 7 0 1 2 Harmonic V1 row 9 0 1 2 Harmonic V2 row 9 0 1 2 Harmonic V3 row 9 0 1 2 Harmonic V1 row 11 0 1 2 Harmonic V2 row 11 0 1 2 Harmonic V3 row 11 0 1 2 Harmonic V1 row 13 0 1 2 Harmonic V2 row 13 0 1 2 Harmonic V3 row 13 0 1 2 Harmonic V1 row 15 0 1 2 Harmonic V2 row 15 0 1 2 Harmonic V3 row 15 0 1 2 Input frame NB The individual harmonics are available if the harmonic module is connected Length 48 bytes 27SOCOMEC R f 876 786 A GB GB DIRIS A40 A41 RS485 PROFIBUS DP USE OF THE PROFIBUS DP MODULES MODULE 8 MIN MAX INSTANTS This module contains the storage of the minimum and maximum values if the 2 input 2 output module is installed The output frame is identical to module 1 NameSize by

温馨提示

  • 1. 本站所有资源如无特殊说明,都需要本地电脑安装OFFICE2007和PDF阅读器。图纸软件为CAD,CAXA,PROE,UG,SolidWorks等.压缩文件请下载最新的WinRAR软件解压。
  • 2. 本站的文档不包含任何第三方提供的附件图纸等,如果需要附件,请联系上传者。文件的所有权益归上传用户所有。
  • 3. 本站RAR压缩包中若带图纸,网页内容里面会有图纸预览,若没有图纸预览就没有图纸。
  • 4. 未经权益所有人同意不得将文件中的内容挪作商业或盈利用途。
  • 5. 人人文库网仅提供信息存储空间,仅对用户上传内容的表现方式做保护处理,对用户上传分享的文档内容本身不做任何修改或编辑,并不能对任何下载内容负责。
  • 6. 下载文件中如有侵权或不适当内容,请与我们联系,我们立即纠正。
  • 7. 本站不保证下载资源的准确性、安全性和完整性, 同时也不承担用户因使用这些下载资源对自己和他人造成任何形式的伤害或损失。

评论

0/150

提交评论