全文预览已结束
下载本文档
版权说明:本文档由用户提供并上传,收益归属内容提供方,若内容存在侵权,请进行举报或认领
文档简介
How Does Altitude Affect AC-DC Power Supplies?Most AC-DC power supplies that meet the safety standards per UL/EN 60950-1 for ITE (Information Technology Equipment) applications are designed to operate at typical office and factory altitudes, which can vary from slightly above sea level to as high as 2,000 meters (6,562 feet). And, many power supply manufacturers provide units that are designed and rated for operation at higher altitudes, up to 3,000 meters (9,843 feet) so their supplies can be used in major cities located at higher elevations (e.g., Denver, Santa Fe, Mexico City, Bogota). Many broadcasting/communications stations/towers are located at altitudes up to 3,000 meters or higher in order to maximize their range.Altitude affects the design of power supplies since air is used as an electric insulating medium (aka, dielectric) in the construction of power supplies, as well as most electronic devices. The density and dielectric strength (insulating property) of air is very good at sea level, but at higher altitudes, the thinner air loses some of its dielectric strength, which needs to be compensated for. Switchmode power supplies operate off of high voltages (inputs of 90 to 265Vac) and internally generate even higher voltages (400Vdc or more), which need to be insulated and contained to prevent high voltage arcing or breakdown within the supply, and to protect the end-equipment and operating personnel.The drawing below shows a cross section of a typical printed circuit board (PCB), which is comprised of copper electric conduction paths that our chemically etched on an insulated (dielectric) fiber board material (e.g., FR4, woven fiberglass cloth with epoxy resin), plus electronic components that are not shown in this drawing. As can be seen, the fiber board and air, combined with the distances between the etched conductive traces are the primary insulation mediums for the circuit board.Drawing Credits: Mammano B, Safety Considerations in Power Supply Design, Underwriters Laboratory / TI The term Clearance refers to shortage path between the two conductive parts (circuit traces, components, etc.), measured through air. The term Creepage refers to the shortage path between two conductive parts measured along the surface of the insulation (PCB, insulating materials/barriers, etc.).What does this have to do with altitude? Since air gets thinner (reduced barometric pressure) at higher altitudes and becomes less of an insulator, the PCB and component layouts have to be designed with sufficient safety spacing distances to prevent high voltage arcs or breakdowns between conductors and/or electronic components.For example, typical power supply design practice may allow 8 mm spacing distance between primary and secondary circuits and 4 mm spacing distance between primary and ground. These spacing distances will vary depending upon the voltage levels between conductors and components and the expected humidity, temperatures, pollution levels, and attitudes.For those power products that must be approved per the Chinese CCC organization (required to export supplies into China), the new Chinese Safety Standard GB 4943.1-2011, which is similar to UL/EN 60950, requires strict specs for creepage and clearance distances. As of December 1, 2012, the primary-to-secondary clearances must increase by a factor of 1.48 to qualify the supply for operation up to 5,000 meters, since many regions in China are located at high altitudes. The alternative for CCC certified power supplies is that they must clearly marked with a warning label that states that the power supply must be used below 2,000 meters (see table below).The base design altitude for ITE power supplies is 2,000 meters. However, as mentioned before, as the altitude increases, the air becomes a poorer insulator and the spacing distances have to be increased per the following table (assuming an 8 mm clearance at 2000m).Altitude (meters)Barometric Pressure (kPa)Multiplication Factor for ClearanceResulting Clearance (mm)200080.01.008.00300070.01,149.12400062.01.2910.32500054.01.4811.84As can be seen from this table, if a power supply is to be operated at 5,000 meters, its conductor/components clearances must be increased by 48% compared to a supply designed for 2,000 meters.The other major effect of high altitudes on power supplies is that the less dense air does not conduct heat as well. To compensate for higher altitudes, power supplies need to be derated, or employ larger heat sinks, or have increased forced air flow, or a combination of these to insure proper cooling. In addition, the power supply must be designed with the proper conductor and component clearances as discussed above.In summary, whenever
温馨提示
- 1. 本站所有资源如无特殊说明,都需要本地电脑安装OFFICE2007和PDF阅读器。图纸软件为CAD,CAXA,PROE,UG,SolidWorks等.压缩文件请下载最新的WinRAR软件解压。
- 2. 本站的文档不包含任何第三方提供的附件图纸等,如果需要附件,请联系上传者。文件的所有权益归上传用户所有。
- 3. 本站RAR压缩包中若带图纸,网页内容里面会有图纸预览,若没有图纸预览就没有图纸。
- 4. 未经权益所有人同意不得将文件中的内容挪作商业或盈利用途。
- 5. 人人文库网仅提供信息存储空间,仅对用户上传内容的表现方式做保护处理,对用户上传分享的文档内容本身不做任何修改或编辑,并不能对任何下载内容负责。
- 6. 下载文件中如有侵权或不适当内容,请与我们联系,我们立即纠正。
- 7. 本站不保证下载资源的准确性、安全性和完整性, 同时也不承担用户因使用这些下载资源对自己和他人造成任何形式的伤害或损失。
最新文档
- 模具机加工协议合同
- 粮油会计考试题库及答案
- 基于栗酒裂殖酵母表达体系的小分子抗癌肽Aurein1.2高效表达策略探究
- 标识标牌策划合同范本
- 基于极值区域检测的血管内超声图像分割算法的创新与实践
- 医院护理应聘题库及答案
- 天津市部分区2025-2026学年高二上学期11月期中考试化学试题(含答案)
- 2026-2031年中国手写板市场深度调查与投资策略报告
- 2026年书法名家作品数字博物馆行业发展现状及未来趋势研究分析报告
- 2025年事业单位招聘考试教育类专业知识试卷(特殊教育理论)试题及答案
- GB/T 5210-2006色漆和清漆拉开法附着力试验
- 预备团员考试题库
- 第2 课《回延安》 课件(41张PPT) 部编版语文八年级下册
- 趣味数学知识课件
- 中国特色社会主义理论与实践研究知识点整理及思考题答案
- 受污染耕地安全利用培训课件讲义
- 干挂大理石施工合同
- 黑龙江省鸡西市各县区乡镇行政村村庄村名居民村民委员会明细及行政区划代码
- 不锈钢管道安装施工方案及对策及对策
- (印刷服务项目投标)印刷服务进度控制计划、印刷服务供货运输方案
- 信用管理概论课件整书电子教案完整版教学课件全套ppt教学教程最全课件最新
评论
0/150
提交评论