给排水设计说明书(北京院英文).doc_第1页
给排水设计说明书(北京院英文).doc_第2页
给排水设计说明书(北京院英文).doc_第3页
给排水设计说明书(北京院英文).doc_第4页
给排水设计说明书(北京院英文).doc_第5页
已阅读5页,还剩1页未读 继续免费阅读

下载本文档

版权说明:本文档由用户提供并上传,收益归属内容提供方,若内容存在侵权,请进行举报或认领

文档简介

PROJECT NO CD06121201PROJECT NAME General Engineering of CYC Project UNIT General EngineeringCLIENT Degussa TITLE DOCUMETNT NO SHEET REV Design Description for Fire fighting SystemCD06121201 00 PF TS 0021 of 60 0Issue for BEPZ T GuoJ H HanX M Tan07 03 31 REVDESCRIPTIONPRE DCHK DAPPRPMDATE Design Description for Firefighting System PROJECT NO CD06121201PROJECT NAME General Engineering of CYC Project UNIT General EngineeringCLIENT Degussa TITLE DOCUMETNT NO SHEET REV Design Description for Fire fighting SystemCD06121201 00 PF TS 0022 of 60 CONTENTS 1 0 GENERAL 3 2 0 DESIGN BASIS 3 3 0 FIREFIGHTING WATER SUPPLY SYSTEM 3 4 0 FIRE HYDRANT SYSTEM 4 5 0 FIRE EXTINGUISHERS 5 6 0 LOCAL FIRE FIGHTING POWER 5 PROJECT NO CD06121201PROJECT NAME General Engineering of CYC Project UNIT General EngineeringCLIENT Degussa TITLE DOCUMETNT NO SHEET REV Design Description for Fire fighting SystemCD06121201 00 PF TS 0023 of 60 1 0 GENERAL Firefighting system includes Firefighting hydrant system Fire extinguisher Mobile low expansion foam extinguishing system 2 0 DESIGN BASIS 2 1 Codes and standards Code for Fire Protection Design of Buildings GB50016 2006 Fire Prevention Code of Petrol Chemical Enterprise Design GB 50160 92 1999 edition Code of Design for Low Expansion Foam Extinguishing System GB 50151 92 2000 edition Code of Design of Extinguisher Distribution in Buildings GB50140 2005 Code for Acceptance of Construction Quality of Water Supply Drainage and Heating Works GB50242 2002 Code for Construction and Acceptance of Industrial Metalic Piping GB50235 97 Standard Drawings for Water Supply and Sewerage S1 S3 edition 2004 2 2 Others The latest documents E mail Meeting minutes Memo Fax Drawings Notice etc Documents provided by client Design input from other discipline 自定义的上网导航 我的上网 1 把自己常用的网站或链接放上去 不用每次都通过 baidu 搜 再进入网站 2 替代 收藏夹 而且换电脑一样可以看到 3 可以自己定义 不像常用的 网址导航 网站太多 很多用 不上 常用的又没有 PROJECT NO CD06121201PROJECT NAME General Engineering of CYC Project UNIT General EngineeringCLIENT Degussa TITLE DOCUMETNT NO SHEET REV Design Description for Fire fighting SystemCD06121201 00 PF TS 0024 of 60 3 0 FIREFIGHTING WATER SUPPLY SYSTEM One independent firefighting water supply system will be set to ensure the firewater supply for the plant Only one place will be taken into consideration where a fire occurs in the plant it should be the place whose fire fighting water consumption is maximum The max outdoor fire water hydrant system water demand is 25l s and the max indoor fire water hydrant hose reel system is 10l s of the general plant according to Code for Fire Protection Design of Buildings GB50016 2006 The maximum fire water demand of all the plant is 35l s and the fire duration in 3hours Based on the point of maximum fire water demand in the plant the design quantity of fire water is 35l s and 3 hours duration so the firewater demand for one fire case is 378 m3 A firewater basin will be constructed in the plant and effective volume is about 525 m3 There are two firewater pumps in firewater pump house one in motor driven is operated another in diesel engine is spare The two pumps are set with the capacity of 40l s and head of 60m Besides that there are two fire jockey pumps and two pressurizer water tanks in the pump house one jocky pump runs and the other standby which are set with the capacity of 2 5l s and head of 80m they can meet the requirement of fire fighting and independent suction pipe is set for each fire water pump The pressure of the network is maintained by jockey pump and pressurizer water tanks The firewater pump is interlocked with the pressure of network In case of fire the pressure of network drop down the pressure switch can start the firewater pump automatically When the motor driven pump gets out of order during power failure the diesel engine driven pump will be started immediately to ensure fire water supply One fire water pipe network is underground and routes in loop in the plant There are two outlet pipes connected with loop fire water network which come from fire water pumps An isolated valve is installed between these two pipes to ensure that if one outlet is in maintenance the other one can supply the total water quantity Fire fighting water will be supplied to all units in the whole plant which includes CYC unit tank farm NaCN unit administration building social building and maintenance shop etc For outside underground pipe network the fire hydrant pipe runs in loop to supply fire water to the whole plant Aboveground fire hydrants and block valves are installed as per the local code approved The size of main pipeline is 8 the smallest pipe size is 4 Fire fighting water system is independent and can not be used for other purpose 4 0 FIRE HYDRANT SYSTEM This system is designed as per local code PROJECT NO CD06121201PROJECT NAME General Engineering of CYC Project UNIT General EngineeringCLIENT Degussa TITLE DOCUMETNT NO SHEET REV Design Description for Fire fighting SystemCD06121201 00 PF TS 0025 of 60 Fire hydrant water is supplied to the outdoor fire water hydrant system and the indoor fire water hydrant hose reel system in the plant Outdoor hydrants of aboveground type are arranged all over the plant Distance between two adjacent outdoor hydrants doesn t exceed 60m Isolated valves are set in the proper location of the loop firewater network to guarantee the hydrants number not more than five Outdoor hydrants of SS100 1 6 are used in this project Each hydrant has a cabinet equipped with two 30m length of 65mm fire hoses two 19mm water current spray two use type nozzles two 80 65 connections Indoor fire water hydrant hose reel system will set in CYC auxiliary material warehouse NaCN unit maintenance and spare parts room administration building and social building etc Relief pressure type fire hose station is necessary where pressure at outlet of fire hose is more than 0 5Mpa in those building The distance between two indoor hose stations shall be no more than 30m The type of indoor fire water hydrant nozzle shoud be as below Water current type should be used in administration building social building and maintenance area Water current spray two use type nozzle should be used in NaCN units and CYC auxiliary material warehouse The fire hydrant system is designed as followings Flow rate of outdoor fire hydrant 25L s Flow rate of indoor fire hose 10L s Firefighting duration 3h 5 0 FIRE EXTINGUISHERS Fire extinguishers shall be allocated according to the Code of Design of Extinguisher Distribution in Buildings GB50140 2005 and according to the different hazard classes in this project the corresponding type and quantity extinguishers are to be allocated to extinguish initial small fire Powder extinguisher will be used for A B C fires CO2 extinguishers will be used for electrical fires In the NaCN unit utility building and CYC auxiliary material warehouse there are 5kg portable powder extinguishers distributed Besides that 5kg portable CO2 extinguishers are allocated in MCC Control MV Switchgear room to extinguish initial electrical fires In the CYC pro

温馨提示

  • 1. 本站所有资源如无特殊说明,都需要本地电脑安装OFFICE2007和PDF阅读器。图纸软件为CAD,CAXA,PROE,UG,SolidWorks等.压缩文件请下载最新的WinRAR软件解压。
  • 2. 本站的文档不包含任何第三方提供的附件图纸等,如果需要附件,请联系上传者。文件的所有权益归上传用户所有。
  • 3. 本站RAR压缩包中若带图纸,网页内容里面会有图纸预览,若没有图纸预览就没有图纸。
  • 4. 未经权益所有人同意不得将文件中的内容挪作商业或盈利用途。
  • 5. 人人文库网仅提供信息存储空间,仅对用户上传内容的表现方式做保护处理,对用户上传分享的文档内容本身不做任何修改或编辑,并不能对任何下载内容负责。
  • 6. 下载文件中如有侵权或不适当内容,请与我们联系,我们立即纠正。
  • 7. 本站不保证下载资源的准确性、安全性和完整性, 同时也不承担用户因使用这些下载资源对自己和他人造成任何形式的伤害或损失。

评论

0/150

提交评论