此文档收集于网络,如有侵权,请联系网站删除.m值测量中的不确定度的估算Uncertainties in molar linear absorption coefficient of Fe3不确定度分量ComponentA类%A Type%B类%B Type%浓度Concentration杯长pathlength温度Temperature光吸收Measurement of optical absorbance波长(0.1nm)wavelength线性(比尔定律)Fit for Bill law制备程序Preparation of solution试剂纯度Pureness of reagent指数非线性Fit for standard curve0.10.020.10.20.020.10.10.10.10.70.010.060.060.02-A类B类分量方根和Both components combined in quadrature at one standard deviation0.32扩展不确定度UExpanded uncertaninty U0.69 (k=2)Frick剂量计测量水井贮源式辐照装置吸收剂量值的不确定度Uncertainties in absorbed dose values in water for a pool type facility by Fricke dosimetry Table 1 Uncertainties in absored dose measuremed by Fricke dosimetry ComponentType A %Type B%G(Fe3+)=1.61(molJ-1)(F3+) 25C to Radiation spectrum(辐射能谱)Variation in spectrophotometer Abs(吸光度测量)Other(其他)-0.27-0.33-0.650.210.200.200.250.30Type A and Type B combined inquadrature separately(A类B类分量方根和)0.430.84Both components combined in quadrature at one standard deviation(合成标准不确定度)0.94Expanded uncertaninty U(扩展不确定度)1.88(k=2)水井贮源式辐照装置中用Frick国家标准校准传递标准剂量计的不确定度Uncertainties in calibration of transfer standard dosimeters in a pool type facility by Fricke dosimetryTable 3 Uncertainties in calirration of dosimeter in the pool type facility by Fricke ComponentType A %Type B%Response of Fricke dosimeterFricke剂量计响应)Source position repeatability(源到位重复性)Irradiation time(辐照时间)Decay corrections(半衰期修正)The beam uniformity over dosimeter(射线束在剂量计体积内的均匀性)non-uniforties in standard radiation(标准辐射的不均匀性)-0.500.100.010.500.250.94-0.03-Type A and Type B combined inquadrature separately(A类B类分量方根和)0.760.94Both components combined in quadrature at one standard deviation(合成标准不确定度)1.21Expanded uncertaninty U(扩展不确定度)2.42(k=2)工业辐照装置中用两个为一组的Fricke剂量计 测量吸收剂量值的不确定度评定 Table 4. Uncertainties in absorbed dose values measured in a production irradiator using sets of two Fricke dosimeters不确定度分量component of uncertatintyA类(%)Type AB类(%)type BFricke剂量计的响应Response of Fricke dosimeters 1.00Fricke剂量计响应(2个一组)Response of Fricke dosimeters(set of two dosimeters)0.30温度修正Temperature correction0.50射线能谱差别的影响Effects due to differences in photon energy spectra of sources0.50A类与B类分量分别用方和根的方法合成Type A and Type B combined in quadrature separately0.301.22合成标准不确定度Both components combined in quadrature at one standard deviation1.26扩展不确定度Expanded uncertaninty U 2.5%(k=2)备注:重铬酸盐剂量计测量系统校准的不确定度评定Table 1. Uncertainties in calibration of dichromate transfer standard dosimetry system ComponentType A %Type B%1.The values of G and Calibration(使用Fricke校准G值和的校准)2. Component of dosimetry system(剂量计组成) 3. Temperature of dosimetry system(剂量计温度修正)4. Irradiation time (辐照时间)5. Dosimeter response (mean of five dosimeters)(剂量计重复性)6. Polynomiial fit for calibration curve (校准曲线的拟合)7. Non-uniforties in standard radiation(标准辐射的不均匀)8. Dose rate and effects due to differences in phonton energy spectra of source(剂量率响应)9. Measurement of specific absorbance (吸光度测量)-0.10.311.00.25-0.301.00.500.50-0.750.20Type A and Type B combined inquadrature separately(A类B类分量方根和)1.121.45Both components combined in quadrature at one standard deviation(合成标准不确定度)1.84Expanded uncertaninty U(扩展不确定度)3.7(k=2) 工业辐照装置中用两个为一组的重铬酸盐剂量计 测量吸收剂量值的不确定度评定 Table 2. Uncertainties in absorbed dose values measured in a production irradiator using sets of two dichromate dosimeters不确定度分量component of uncertatintyA类(%)Type AB类(%)type B重铬酸盐剂量计系统Dichromate dosimetry system 1.121.45重铬酸盐剂量计响应(2个一组)Response of dichromate dosimeters(set of two dosimeters)0.30温度修正Temperature correction0.50射线能谱差别的影响Effects due to differences in photon energy spectra of sources0.50A类与B类分量分别用方和根的方法合成Type A and Type B combined in quadrature separately1.161.61合成标准不确定度Both components combined in quadrature at one standard deviation1.99扩展不确定度Expanded uncertaninty U 4.0 %(k=2)备注:电子束装置水中吸收剂量的不确定度评定 Table 1. The uncertainty in absorbed dose in water measured for EB irradiator for radiation processing不确定度分量component of uncertatintyA类(%)Type AB类(%)type B重铬酸盐剂量计系统Dichromate dosimetry system -1.84辐照稳定度Stability after irradiation0.50辐照条件的影响(不均匀性与减弱)Influence of irradiation condition (Non-uniformity and attenuatiion)0.501.0A类与B类分量分别用方和根的方法合成Type A and Type B combined in quadrature separately0.712.1合成标准不确定度Both components combined in quadrature at one standard deviation2.21扩展不确定度Expanded uncertaninty U 4.5%(k=2)备注:在电子束装置水中用重铬酸盐传递标准剂量计校准FWT-60剂量计的不确定度评定 Table 2. The uncertainty in calibration of FWT-60 dosimeters in EB irradiator using the dichromaters transfer standard 不确定度分量component of uncertatintyA类(%)Type AB类(%)type B重铬酸盐剂量计系统Dichromate dosimetry system -1.84辐照稳定度Stability after irradiation0.50辐照条件的影响(不均匀性与减弱)Influence of irradiation condition (Non-uniformity and attenuatiion)0.501.0FWT-60剂量计的响应Film dosimeter response (set of three dosimeters)0.6-校准曲线的多项拟合polynomial fit for calibration cure 1.0-A类与B类分量分别用方和根的方法合成Type A and Type B combined in quadrature separately1.362.1合成标准不确定度Both components combined in quadrature at one standard deviation2.5扩展不确定度Expanded uncertaninty U 5.0 %(k=2)备注:用FWT-60薄膜剂量计校准EB辐射加工装置吸收剂量的不确定度评定 Table 3. The uncertainty in absorbed dose values in water for EB irradiator for radiation processing calibrated by FWT-60 radio-chromic film dosimetry不确定度分量component of uncertatintyA类(%)Type AB类(%)type B重铬酸盐剂量计系统Dichromate dosimetry system -1.84比吸光度的测量Measurement specific absorbance 0.501.0剂量计响应的测量重复性Measured repeatability for response of dosimeter0.501.0辐照期间的温度修正Temperature correction during irradiation

温馨提示

  • 1. 本站所有资源如无特殊说明,都需要本地电脑安装OFFICE2007和PDF阅读器。图纸软件为CAD,CAXA,PROE,UG,SolidWorks等.压缩文件请下载最新的WinRAR软件解压。
  • 2. 本站的文档不包含任何第三方提供的附件图纸等,如果需要附件,请联系上传者。文件的所有权益归上传用户所有。
  • 3. 本站RAR压缩包中若带图纸,网页内容里面会有图纸预览,若没有图纸预览就没有图纸。
  • 4. 未经权益所有人同意不得将文件中的内容挪作商业或盈利用途。
  • 5. 人人文库网仅提供信息存储空间,仅对用户上传内容的表现方式做保护处理,对用户上传分享的文档内容本身不做任何修改或编辑,并不能对任何下载内容负责。
  • 6. 下载文件中如有侵权或不适当内容,请与我们联系,我们立即纠正。
  • 7. 本站不保证下载资源的准确性、安全性和完整性, 同时也不承担用户因使用这些下载资源对自己和他人造成任何形式的伤害或损失。

评论

0/150

提交评论