




免费预览已结束,剩余50页可下载查看
下载本文档
版权说明:本文档由用户提供并上传,收益归属内容提供方,若内容存在侵权,请进行举报或认领
文档简介
2020 3 7 BrukerConfidential 1 MALDITOF质谱培训周春喜博士布鲁克公司应用工程师 欢迎参加 2020 3 7 BrukerConfidential 2 MALDITOF质谱仪的基本原理多肽和蛋白质样品的制备仪器操作和数据采集 FlexControl 数据分析 FlexAnalysis BioTools etc 培训内容 2020 3 7 BrukerConfidential 3 质谱法 MASSSPECTROMETRY Analyticalmethoddeterminingthemolecularmassofions 质谱仪 MASSSPECTROMETER Analyticalinstrumentforthedeterminationofthemolecularmassofions 2020 3 7 BrukerConfidential 4 常见的离子源 FastAtomBombardment FABIonBombardment SIMSFieldDesorption FDLaserIonizationElectroSprayIonization ESIMatrixAssistedLaserDesorption Ionization MALDI基质辅助激光解析电离 2020 3 7 BrukerConfidential 5 常见的质量分析器 QuadrupolMagneticSectorIonTrapICRFTMSTime of Flight TOF飞行时间 2020 3 7 BrukerConfidential 6 Laser SampleTarget Detector Clock Time of Flight MolecularMass MALDI TOF的基本原理 2020 3 7 BrukerConfidential 7 EnablingLifeScienceToolsBasedonMassSpectrometryTM Ek zqUEk 1 2mV2 V2 2qUz m 2qU m z 2020 3 7 BrukerConfidential 8 MALDITOFMS的构成 2020 3 7 BrukerConfidential 9 反射模式下TOF的分辨率高于线性模式 LinearTOF MS ReflectionTOF MS 2020 3 7 BrukerConfidential 10 线性模式适合大分子 蛋白质 核酸 多聚物等 分辨率和质量准确度低于反射模式 通常测得的为平均分子量反射模式适合分子量 5000Da的物质 如多肽 寡糖等 分辨率高 可准确测得单同位素分子量 2020 3 7 BrukerConfidential 11 灵敏度分辨率准确度 EnablingLifeScienceToolsBasedonMassSpectrometryTM 质谱仪的主要性能指标 2020 3 7 BrukerConfidential 12 质量分辨率Itisameasureofamassspectrometer sabilitytodistinguishtwocompoundsofnearlyequalmass 600 800 1000 1200 1400 1600 1800 2000 2200 2400 m z 100 200 300 400 500 600 700 800 900 1000 1100 a i 1618 1623 1628 m z easy notsoeasy m 1620Dm 0 2R 8100 EnablingLifeScienceToolsBasedonMassSpectrometryTM Resolution m z Dm Dm FullWidthatHalfMaximum FWHM 2020 3 7 BrukerConfidential 13 质量准确度 Massaccuracycanbeexpressedasapercentageorppm e g massaccuracy Verysmallpercentageerrors 0 01 areexpressedaspartspermillionorppm 0 01 100ppm Measuredmass 1296 970Truemass 1296 6850 02 error ppm 0 001perthousand EnablingLifeScienceToolsBasedonMassSpectrometryTM 2020 3 7 BrukerConfidential 14 ACTH 18 39 C112H166N27O36 R 40002465 2m z R 20002466 21m z R 10002466 36m z R 5002466 58m z 分辨率影响准确度 EnablingLifeScienceToolsBasedonMassSpectrometryTM 2020 3 7 BrukerConfidential 15 如何提高准确度 分辨率和灵敏度 仪器调节 仪器校准 延时提取 激光功率 基质抑制 数据采集频率样品制备 基质选择 点靶方法 样品纯化 2020 3 7 BrukerConfidential 16 仪器校准 校正方程 m z At2 Bt C内标法 样品与标准品点在同一靶点外标法 样品与标准品点在不同靶点 2020 3 7 BrukerConfidential 17 ReasonsforPeakbroadeningorpoorResolution PreparationInitialEnergySpreadCoulombrepulsionandFragmentationofionsduetohighlaserpowerChargingupofcontaminationintheionoptics 2020 3 7 BrukerConfidential 18 初始能量不均 2020 3 7 BrukerConfidential 19 初始能量不均导致谱峰变宽 分辨率降低 2020 3 7 BrukerConfidential 20 如何补偿初始能量的不均 Uacc L Ionsource Field freedriftregion M1 Detector m z Int MH 2020 3 7 BrukerConfidential 21 延时提取产生聚焦效果 IS1 L Ionsource Field freedriftregion M1 Detector Epot t tdelay 2020 3 7 BrukerConfidential 22 延时提取产生聚焦效果 IS1 L Ionsource Field freedriftregion M1 Detector Epot t tdelay 2020 3 7 BrukerConfidential 23 延时提取产生聚焦效果 IS1 L Ionsource Field freedriftregion Detector Epot t tdelay IS2 dEpot t tdelay Tuningparameter IS2tdelay 2020 3 7 BrukerConfidential 24 Reflectron IS1 Ionsource M LinearDetector R2 Urefl ReflectorDetector 1 1 1 2 2 2 IS2 1 2 IncreasingofResolutionandSignal toNoisebyfocusingtheionsinTimeandSpace gridlessdesign 2020 3 7 BrukerConfidential 25 数据采集速率DigitizationRate EnablingLifeScienceToolsBasedonMassSpectrometryTM 2020 3 7 BrukerConfidential 26 低质量端的大量背景信号 K Matrix Matrixdimer Analyte 2020 3 7 BrukerConfidential 27 抑制基质峰的方法 偏转法Deflection Withthedeflectoron ionsaredeflectedofftheionopticalaxisandcannotreachthedetector 降压法Detectorgating Withdetectorgatingon thevoltageonthedetectorisreducedduringtheearlypartofeverytimeperiod Onlythelineardetectorisequippedwiththegatingoption EnablingLifeScienceToolsBasedonMassSpectrometryTM 2020 3 7 BrukerConfidential 28 偏转法 EnablingLifeScienceToolsBasedonMassSpectrometryTM 2020 3 7 BrukerConfidential 29 降压法 Preventsaturationofthedetectorbydeflectionoflowmassionsorrampingthedetectorvoltage detectorgating Onlyionsofinterestreachthedetector 2020 3 7 BrukerConfidential 30 Matrix HCCA H 基质吸收激光的能量 并将部分能量传递给样品 帮助样品离子化 Matrix 样品分子 TimeofFlight 基质的作用 2020 3 7 BrukerConfidential 31 常用的基质 EnablingLifeScienceToolsBasedonMassSpectrometryTM 2020 3 7 BrukerConfidential 32 MatrixAnalyteSinapinicacidproteins glycos polarpolymersDHBproteins glycos sugars polarpolymerssuper DHBproteins glycos sugars polarpolymersalpha cyanopeptidesHABApeptides proteinsTHAP1oligonucleotidesHPA1oligonucleotidesDithranol2nonpolarpolymersIAA2nonpolarpolymersAdditives 1 ammoniumcitrate2 Ag TFA 基质的选择 2020 3 7 BrukerConfidential 33 点样方法 DriedDroplet matrix analyte samplesolution sampledeposition Analytedispersedthroughoutmatrixcrystals EnablingLifeScienceToolsBasedonMassSpectrometryTM 2020 3 7 BrukerConfidential 34 样品厚度不均匀的后果 Uacc A B UB UA A B UB UA E 1 2kV mm Example Dx 50mm Dtof 3 4nsorDm 0 27Daat2465Da A B B A 2020 3 7 BrukerConfidential 35 AnchorChip 普通靶 疏水涂层靶 2020 3 7 BrukerConfidential 36 疏水涂层靶 普通靶AnchorChip 2mm 600um 2020 3 7 BrukerConfidential 37 杂质对样品信号的抑制 Caseindigestwith200mMKCland0 1 Tween20 Caseindigestaftercleanup EnablingLifeScienceToolsBasedonMassSpectrometryTM 2020 3 7 BrukerConfidential 38 样品之间的信号抑制 1300 1800 2300 m z 500 1000 1500 2000 2500 3000 3500 4000 4500 5000 5500 6000 6500 a i Equimolarmixturesmayproduceunequalpeakintensities Competitionforchargeaffectsionabundances morebasicanalytesfavored EnablingLifeScienceToolsBasedonMassSpectrometryTM 2020 3 7 BrukerConfidential 39 MALDI TOF TOF质谱仪 2020 3 7 BrukerConfidential 40 EnablingLifeScienceToolsBasedonMassSpectrometryTM LID 激光诱导解离 Laser puts somuchenergyintoamoleculethatthemolecule fragments CID 碰撞诱导解离 MoleculesflythroughacollisioncellandfragmentasaresultofcollisionswithcollisiongasesLIDandCIDareusedintheAutoFlexastwoalternativeandcomplementarydissociationmethods 诱导解离的方式 2020 3 7 BrukerConfidential 41 LinearTOF Source1 Detector 源后裂解 post sourcedecay PSD 2020 3 7 BrukerConfidential 42 PSD碎片被反射镜分离 但不能一次全部被检测 2020 3 7 BrukerConfidential 43 triggerdiode N2laser PostSourceDecay PSD highreflectorvoltage 2020 3 7 BrukerConfidential 44 triggerdiode N2laser PostSourceDecay PSD mediumreflectorvoltage 2020 3 7 BrukerConfidential 45 triggerdiode N2laser PostSourceDecay PSD lowreflectorvoltage 2020 3 7 BrukerConfidential 46 MALDITOF TOF的原理 LIFT LIFTanalysis ClassicalPSD Ekin 1 2mv2 Source 2020 3 7 BrukerConfidential 47 Target LIFT Selector MALDITOF TOFScheme PotentialProfileduringLIFT LIFT EnablingLifeScienceToolsBasedonMassSpectrometryTM 2020 3 7 BrukerConfidential 48 MALDITOF TOF的原理 LIFT 质谱图 离子检测器 离子反射器 母离子选择器 MALDI离子源 LIFT子离子加速器 2020 3 7 BrukerConfidential 49 TOF TOF二级质谱图 AngiotensinIIat1046 931 513 1046 555 354 201 400 216 110 064 517 260 647 358 756 390 263 147 0 1000 2000 3000 4000 5000 6000 Intens a u 100 200 300 400 500 600 700 800 900 1000 m z 2020 3 7 BrukerConfidential 50 Terminology LIFT LaserInducedFragmentationTechniquePatentedverysensitivemethodtoacquireTOF TOFspectrawithhigh energydetectionofproductionsviaBrukerinnovativepotential lift inultraflexFragmentionsare lifted post accelerated ontohigherenergy EnablingLifeScienceToolsBas
温馨提示
- 1. 本站所有资源如无特殊说明,都需要本地电脑安装OFFICE2007和PDF阅读器。图纸软件为CAD,CAXA,PROE,UG,SolidWorks等.压缩文件请下载最新的WinRAR软件解压。
- 2. 本站的文档不包含任何第三方提供的附件图纸等,如果需要附件,请联系上传者。文件的所有权益归上传用户所有。
- 3. 本站RAR压缩包中若带图纸,网页内容里面会有图纸预览,若没有图纸预览就没有图纸。
- 4. 未经权益所有人同意不得将文件中的内容挪作商业或盈利用途。
- 5. 人人文库网仅提供信息存储空间,仅对用户上传内容的表现方式做保护处理,对用户上传分享的文档内容本身不做任何修改或编辑,并不能对任何下载内容负责。
- 6. 下载文件中如有侵权或不适当内容,请与我们联系,我们立即纠正。
- 7. 本站不保证下载资源的准确性、安全性和完整性, 同时也不承担用户因使用这些下载资源对自己和他人造成任何形式的伤害或损失。
最新文档
- 生药学试题及答案填空题
- 数字安全环境下国家安全威胁的多维度评估方法-洞察及研究
- 高频接地施工合同范本(3篇)
- 高空作业施工拆卸合同(3篇)
- 宠物领养与送养双方权益保障协议书
- 时尚街区品牌店面转租合作协议范本
- 自动驾驶汽车与移动应用的深度协同-洞察及研究
- 城市轨道交通材料运输及进度控制合同
- 高效个人购房贷款及专业担保服务合同
- 国际工程项目承包与咨询服务合同
- 2025年芜湖市鸠江区医疗卫生事业单位公开招聘工作人员22名考试参考题库及答案解析
- 2025年康复医学老年康复护理常规操作规范考核试卷答案及解析
- 青春不越界+法制伴我行主题班会课件-2025-2026学年上学期
- 2025年高二上语文(统编版选择性必修上)第二单元检测(后附答案)
- 村干部笔试试题及答案
- 2025年中国兵器工业集团校园招聘考试题库及备考指南
- 南昌教师考试题目及答案
- 2个商铺租赁合同范本
- 项目管理业务知识培训课件
- 2025年秋期新教科版6年级上册小学科学教学计划+进度表
- 1.1《土壤里面有什么》课件 2025-2026学年苏教版科学三年级上册
评论
0/150
提交评论