更换SSA RAID阵列中硬盘的步骤.doc_第1页
更换SSA RAID阵列中硬盘的步骤.doc_第2页
更换SSA RAID阵列中硬盘的步骤.doc_第3页
更换SSA RAID阵列中硬盘的步骤.doc_第4页
全文预览已结束

下载本文档

版权说明:本文档由用户提供并上传,收益归属内容提供方,若内容存在侵权,请进行举报或认领

文档简介

建了RAID的磁盘阵列在使用过程中可能会发生硬盘出现故障需要更换的情况,本文介绍了安全更换硬盘而不破坏数据的详细步骤。1. 首先需要从RAID定义中逻辑上删除故障硬盘。执行下面的命令:# smit ssaraid- Change Member Disks in an SSA RAID Array- Remove a Disk from an SSA RAID Array2. 屏幕显示出如下的阵列列表:Change Member Disks in an SSA RAID ArrayMove cursor to desired item and press Enter.Remove a Disk From an SSA RAID ArrayAdd a Disk to an SSA RAID ArraySwap Members of an SSA RAID Array-SSA RAID Array Move cursor to desired item and press Enter. Use arrow keys to scroll. hdisk6 -6010337B163E30K good -2.3GB -RAID-5 array hdisk5 -09523173A02137K good -2.3GB -RAID-5 array F1=Help -F2=Refresh -F3=Cancel F8=Image -F10=Exit -Enter=Do /=Find - n=Find Next -选择要删除的硬盘所在的阵列的名称,在本例中选择 hdisk6。3. 屏幕显示如下的信息:Remove a Disk From an SSA RAID ArrayType or select values in entry fields.Press Enter AFTER making all desired changes.-Entry FieldsSSA RAID Manager -ssa1SSA RAID Array -hdisk6Connection Address / Array Name -6010337B163E30K* Disk to Remove -+F1=Help -F2=Refresh -F3=Cancel -F4=ListF5=Reset -F6=Command -F7=Edit -F8=Image F9=Shell -F10=Exit -Enter=Do 按下F4键,列出属于该RAID阵列中的硬盘。 4. 硬盘列表显示如下:Remove a Disk From an SSA RAID ArrayType or select values in entry fields.Press Enter AFTER making all desired changes.-Entry FieldsSSA RAID Manager -ssa1SSA RAID Array -hdisk6Connection Address / Array Name -6010337B163E30K* Disk to Remove -+-Disk to Remove Move cursor to desired item and press Enter. Use arrow keys to scroll. pdisk4 -0004AC50374D00D member -present -1.1GB -Physical pdisk5 -0004AC510D9100D member -present -1.1GB -Physical pdisk7 -0004AC510D9900D member -present -1.1GB- Physical F1=Help -F2=Refresh -F3=Cancel F8=Image -F10=Exit - Enter=Do /=Find - n=Find Next -从上面显示的列表中选择需要删除的硬盘。5. 使用“Set service Mode”服务帮助将需要删除的硬盘设置为维护模式。命令如下:# diag- Task Selection (Service Aids )- SSA Service Aids - Set Service Mode - (选择硬盘)- Set or Reset Service Mode This will set the drive to service so the drive canbe replaced. You will see a prompt displayed nextto the drive listing when service is set.例:-pdisk0 -AC503429 -00-03-P -1GB SSA C Physical Disk Drive-pdisk1 -AC510D98 -00-03-P -1GB SSA C Physical Disk Drive-pdisk2 -AC510D91 -00-03-P -1GB SSA C Physical Disk Drive-pdisk3 -AC510D96 -00-03-P -1GB SSA C Physical Disk Drive-pdisk4 -AC50374D -00-03-P -1GB SSA C Physical Disk Drive pdisk5 -AC510D91 -00-03-P -1GB SSA C Physical Disk Drive-pdisk6 -AC510DBB -00-03-P -1GB SSA C Physical Disk Drive-pdisk7 -AC510D99 -00-03-P -1GB SSA C Physical Disk Drive6. 物理上拿掉故障硬盘。若不确定是那一块,可以看到故障硬盘的电源灯旁的黄色检查灯是亮的。7. 物理上安装好替换的硬盘。8. 按照步骤5的方法将硬盘从维护模式设置回普通模式。 9. 逻辑上从系统中删除旧的硬盘信息,再将新更换的硬盘配置起来:# rmdev -dl pdisk* (其中,pdisk* 为具体的硬盘号,本例中为pdisk5。) # cfgmgr10. 下面需要将新更换的硬盘设置为阵列的候选盘:# smitty ssaraid- Change/Show Use of an SSA Physical Disk- - 选择正确的 SSA Raid卡。从列表中选择正确的硬盘 (屏幕显示如下)-SSA Physical Disk Move cursor to desired item and press Enter. Use arrow keys to scroll. # SSA physical disks that are members of arrays. pdisk4 -0004AC50374D00D member -n/a -1.1GB -Physical pdisk7 -0004AC510D9900D member -n/a -1.1GB -Physical # # SSA physical disks that are AIX system disks. pdisk5 -0004AC510D9300D system n/a -1.1GB Physical F1=Help - F2=Refresh -F3=Cancel F8=Image -F10=Exit -Enter=Do /=Find -n=Find Next -Make sure the Current Use Parameter is set to Array Candidate Disk onthe next screen (listed below). Press Tab on Current Use to changeand then Enter to execute.Change/Show Use of an SSA Physical DiskType or select values in entry fields.Press Enter AFTER making all desired changes.-Entry FieldsSSA RAID Manager -ssa1SSA Physical Disk- pdisk5 CONNECTION address -0004AC510D9300D Current Use -Array Candidate Disk11. 将新更换的硬盘添加回RAID阵列中:# smit ssaraid- Change Member Disks in an SSA RAID Array - Add a Disk to an SSA RAID Array-选择正确的RAID名称,-按F4选择硬盘按回车后,选择的硬盘被加入到RAID阵列中,系统在该硬盘上自动重建信息。12. 查看信息重建的状态:# smit ssaraid- List Status Of All Defined SSA RAID Arrays屏幕显示如下:COMMAND STATUSCommand: OK -stdout: yes -stderr: noBefore command

温馨提示

  • 1. 本站所有资源如无特殊说明,都需要本地电脑安装OFFICE2007和PDF阅读器。图纸软件为CAD,CAXA,PROE,UG,SolidWorks等.压缩文件请下载最新的WinRAR软件解压。
  • 2. 本站的文档不包含任何第三方提供的附件图纸等,如果需要附件,请联系上传者。文件的所有权益归上传用户所有。
  • 3. 本站RAR压缩包中若带图纸,网页内容里面会有图纸预览,若没有图纸预览就没有图纸。
  • 4. 未经权益所有人同意不得将文件中的内容挪作商业或盈利用途。
  • 5. 人人文库网仅提供信息存储空间,仅对用户上传内容的表现方式做保护处理,对用户上传分享的文档内容本身不做任何修改或编辑,并不能对任何下载内容负责。
  • 6. 下载文件中如有侵权或不适当内容,请与我们联系,我们立即纠正。
  • 7. 本站不保证下载资源的准确性、安全性和完整性, 同时也不承担用户因使用这些下载资源对自己和他人造成任何形式的伤害或损失。

最新文档

评论

0/150

提交评论