


全文预览已结束
下载本文档
版权说明:本文档由用户提供并上传,收益归属内容提供方,若内容存在侵权,请进行举报或认领
文档简介
循证医学实践教学案例分析 2014年2月18日修訂科別:口腔正畸科住院号:38871初诊日期:2013年1月报告者姓名:职务: 住院医师 基地医师 实习医师 完成时间:2014.4.12病例摘要黄某,男,21岁。初诊日期:2013年1月;结束时间:2014年4月。主 诉:夜间睡眠打鼾憋气5年。诊 断:骨性类,牙性类,轻度睡眠呼吸暂停综合征矫治设计:正畸治疗,IST矫治器初期:效果不佳,改用TAP矫治器效果:1. 睡眠呼吸暂停症状彻底解除。2. 上下颌牙齿排齐整平,前牙覆牙合、覆盖正常,中线对齐,磨牙、尖牙关系中性,侧貌有所改善。提出可回答的临床问題(Asking)P: 轻中度OSAHS患者I: TAP矫治器C: IST矫治器O:治疗效果提高检索最有用的证据(Acquire)关键词( Key word ):OSAHS,oral appliances数据库来源 ( Database ):PubMed Clinical Queries主要內容:A randomized prospective long-term study of two oral appliances for sleep apnoea treatmentSUMMARY Various types of mandibular protrusive appliances have revealed dierent treatment success in mild-to-moderate obstructive sleep apnoea (OSA). The present study compared the long-term eect of two dierent appliances in the treatment of OSA. A total of 103 patients with OSA were randomized and treated with an ISTor Thornton Anterior Positioner (TAP) appliance. They were followed-up after a short-term treatment period of 6 months and long-term treatment period of over 24 months. Sleep studies in the sleep laboratory were conducted with and without the appliances, and various questionnaires assessing subjective daytime sleepiness, sleep quality, quality of life and symptom scores were administered at each time interval. Quality of life, sleep quality, sleepiness, symptoms and sleep outcome showed signicant improvement in the short-term evaluation with both appliances, but the TAP appliance revealed a signicantly greater eect. After more than 2 years of treatment, sleep outcomes revealed an equal eect with both appliances. The subjective benets achieved initially lessened signicantly. This study illustrates that both the ISTand the TAP appliances are eective therapeutic devices for OSA after a period of over 24 months. Lack of compliance may be due to insucient improvement in anticipated subjective symptoms and or a recurrence of symptoms over time.证据评价 (Appraisal )证据等級:A级Worksheet:一、真实性随机分组,隐藏措施(计算机随机),基线一致,short-term时间短,失访率低,long-termT2随访时间长,失访率高,无具体指出而是引用其他文献方法,可推测ITT,采用盲法,测量指标客观,基础治疗一致二、强度与精度:1. short-term:P 0.05,P 0.001 compared without the appliance,P 0.05 IST appliance versus TAP appliance. IST appliance: n = 47; TAP appliances: n = 48.Values are means SD, medians (quartiles ranges).2. long-term:Signicant with the device compared without it,signicant comparison between T1 and T2,signicant comparison between IST appliance and TAP appliance, IST : n = 24, TAP: n = 21.Values are means SD, medians (quartiles ranges)三、实用性1研究对象: Patients were recruited between July 2001 and December 2003 through the sleep laboratory of the department of Respiratory Care at the University Hospital of Freiburg (Germany) (17 females and 86 males; age: 55.5 10.6 years, body mass index (BMI): 25.9 2.9 kg/ m2)存在社会人口学差异2. 可行性好3. 无危险性评估4. 结合病人期望,爱好,病人决定治疗证据解读及证据应用( Apply ) 随着社会经济的发展,阻塞性睡眠呼吸暂停低通气综合征(OSAHS)发病率有明显增长的趋势。OSAHS以睡眠期间上气道反复发生阻塞为特征,引起呼吸暂停,低通气及睡眠紊乱,一般表现为睡眠打鼾、低氧血症及白天嗜睡等。有三大主要治疗方法,一、持续正压通气治疗(呼吸机)。二、手术治疗:如扁桃体腺样体摘除、鼻腔手术,舌咽成形术及口腔正颌手术等。三、口腔矫治器治疗:口腔矫治器适用于单纯鼾症患者及轻、中度OSAHS患者。另外,对那些拒绝或无法耐受呼吸机治疗或经手术治疗后复发的患
温馨提示
- 1. 本站所有资源如无特殊说明,都需要本地电脑安装OFFICE2007和PDF阅读器。图纸软件为CAD,CAXA,PROE,UG,SolidWorks等.压缩文件请下载最新的WinRAR软件解压。
- 2. 本站的文档不包含任何第三方提供的附件图纸等,如果需要附件,请联系上传者。文件的所有权益归上传用户所有。
- 3. 本站RAR压缩包中若带图纸,网页内容里面会有图纸预览,若没有图纸预览就没有图纸。
- 4. 未经权益所有人同意不得将文件中的内容挪作商业或盈利用途。
- 5. 人人文库网仅提供信息存储空间,仅对用户上传内容的表现方式做保护处理,对用户上传分享的文档内容本身不做任何修改或编辑,并不能对任何下载内容负责。
- 6. 下载文件中如有侵权或不适当内容,请与我们联系,我们立即纠正。
- 7. 本站不保证下载资源的准确性、安全性和完整性, 同时也不承担用户因使用这些下载资源对自己和他人造成任何形式的伤害或损失。
最新文档
- 智慧社区:两人合伙智慧社区建设合作协议
- 商铺租赁合同中租赁物损坏赔偿及修复合同
- 借读生校园社会实践协议及实践成果转化合同
- 2025公务员求职面试题目及答案
- 激光冲击成形技术-洞察及研究
- 主管专业知识试题及答案
- 基于离线的智能配电网控制-洞察及研究
- 军史知识竞赛题及答案2025年
- 神经炎症基因调控-洞察及研究
- ICU脑梗死的护理查房
- 科学道德与学风建设讲座
- T-YNX 002-2025 葡萄组培脱毒快繁技术规程
- 衣服投标供货方案(3篇)
- 2025至2030年中国丁酮肟市场现状分析及前景预测报告
- 公司电脑补贴管理办法
- 中石化对供应商管理办法
- Unit 2 Home Sweet Home 语法与阅读专项练习 (含答案) 人教版(2024)八年级上册
- 2025年少先队应知应会知识竞赛考试题库及答案
- 【课件】第14章+全等三角形+数学活动++式+课件2025-2026学年人教版数学八年级上册
- 2025版安全生产法全文
- 高中英语高考词汇200句-教师版(简单句80)二
评论
0/150
提交评论